OneDSE: A Unified Microprocessor Metric Prediction and Design Space Exploration Framework
Authors:
Ritik Raj,
Akshat Ramachandran,
Jeff Nye,
Shashank Nemawarkar,
Tushar Krishna
Abstract:
With the diminishing returns of Moore Law scaling and as power constraints become more impactful, processor designs rely on architectural innovation to achieve differentiating performance. Innovation complexity has increased the design space of modern high-performance processors. This work offers an efficient and novel design space exploration (DSE) solution to these challenges of modern CPU desig…
▽ More
With the diminishing returns of Moore Law scaling and as power constraints become more impactful, processor designs rely on architectural innovation to achieve differentiating performance. Innovation complexity has increased the design space of modern high-performance processors. This work offers an efficient and novel design space exploration (DSE) solution to these challenges of modern CPU design. We identify three key challenges in past DSE approaches: (a) Metric prediction is slow and inaccurate for unseen workloads, microarchitectures, (b) Search is slow and inaccurate in CPU parameter space, and (c) A Single model is unable to learn the huge design space. We present OneDSE, a unified metric predictor and CPU parameter explorer to mitigate these challenges with three key techniques: (a) Transformer-based workload-Aware CPU DSE (TrACE) predictor that outperforms state-of-the-art ANN-based prediction methods by 2.75x and 6.12x with and without fine-tuning, respectively, on several benchmarks; (b) a novel metric space search approach that outperforms optimized metaheuristics by 1.19x while reducing search time by an order of magnitude; (c) MARL-based multi-agent framework that achieves a 10.6% reduction in prediction error compared to its non-MARL counterpart, enabling more accurate and efficient exploration of the CPU design space.
△ Less
Submitted 29 April, 2025;
originally announced May 2025.
Full-dose Whole-body PET Synthesis from Low-dose PET Using High-efficiency Denoising Diffusion Probabilistic Model: PET Consistency Model
Authors:
Shaoyan Pan,
Elham Abouei,
Junbo Peng,
Joshua Qian,
Jacob F Wynne,
Tonghe Wang,
Chih-Wei Chang,
Justin Roper,
Jonathon A Nye,
Hui Mao,
Xiaofeng Yang
Abstract:
Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes with high radiation exposure. Improving image quality is desirable for all clinical applications while minimizing radiation exposure is needed to reduce risk t…
▽ More
Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes with high radiation exposure. Improving image quality is desirable for all clinical applications while minimizing radiation exposure is needed to reduce risk to patients. Approach: We introduce PET Consistency Model (PET-CM), an efficient diffusion-based method for generating high-quality full-dose PET images from low-dose PET images. It employs a two-step process, adding Gaussian noise to full-dose PET images in the forward diffusion, and then denoising them using a PET Shifted-window Vision Transformer (PET-VIT) network in the reverse diffusion. The PET-VIT network learns a consistency function that enables direct denoising of Gaussian noise into clean full-dose PET images. PET-CM achieves state-of-the-art image quality while requiring significantly less computation time than other methods. Results: In experiments comparing eighth-dose to full-dose images, PET-CM demonstrated impressive performance with NMAE of 1.278+/-0.122%, PSNR of 33.783+/-0.824dB, SSIM of 0.964+/-0.009, NCC of 0.968+/-0.011, HRS of 4.543, and SUV Error of 0.255+/-0.318%, with an average generation time of 62 seconds per patient. This is a significant improvement compared to the state-of-the-art diffusion-based model with PET-CM reaching this result 12x faster. Similarly, in the quarter-dose to full-dose image experiments, PET-CM delivered competitive outcomes, achieving an NMAE of 0.973+/-0.066%, PSNR of 36.172+/-0.801dB, SSIM of 0.984+/-0.004, NCC of 0.990+/-0.005, HRS of 4.428, and SUV Error of 0.151+/-0.192% using the same generation process, which underlining its high quantitative and clinical precision in both denoising scenario.
△ Less
Submitted 16 April, 2024; v1 submitted 24 August, 2023;
originally announced August 2023.