-
Enhanced Denoising of Optical Coherence Tomography Images Using Residual U-Net
Authors:
Akkidas Noel Prakash,
Jahnvi Sai Ganta,
Ramaswami Krishnadas,
Tin A. Tunc,
Satish K Panda
Abstract:
Optical Coherence Tomography (OCT) imaging is pivotal in diagnosing ophthalmic conditions by providing detailed cross-sectional images of the anterior and posterior segments of the eye. Nonetheless, speckle noise and other imaging artifacts inherent to OCT impede the accuracy of diagnosis significantly. In this study, we proposed an enhanced denoising model using a Residual U-Net architecture that…
▽ More
Optical Coherence Tomography (OCT) imaging is pivotal in diagnosing ophthalmic conditions by providing detailed cross-sectional images of the anterior and posterior segments of the eye. Nonetheless, speckle noise and other imaging artifacts inherent to OCT impede the accuracy of diagnosis significantly. In this study, we proposed an enhanced denoising model using a Residual U-Net architecture that effectively diminishes noise and improves image clarity across both Anterior Segment OCT (ASOCT) and polarization-sensitive OCT (PSOCT) images. Our approach demonstrated substantial improvements in image quality metrics: the Peak Signal Noise Ratio (PSNR) was 34.343 $\pm$ 1.113 for PSOCT images, and Structural Similarity Index Measure (SSIM) values were 0.885 $\pm$ 0.030, indicating enhanced preservation of tissue integrity and textural details. For ASOCT images, we observed the PSNR to be 23.525 $\pm$ 0.872 dB and SSIM 0.407 $\pm$ 0.044, reflecting significant enhancements in visual quality and structural accuracy. These metrics substantiate the models efficacy in not only reducing noise but also in maintaining crucial anatomical features, thereby enabling more precise and efficient clinical evaluations. The dual functionality across both ASOCT and PSOCT modalities underscores the versatility and potential for broad application in clinical settings, optimizing diagnostic processes and reducing the necessity for prolonged imaging sessions.
△ Less
Submitted 24 September, 2024; v1 submitted 17 July, 2024;
originally announced July 2024.
-
Adaptive Bayesian Optimization for High-Precision Motion Systems
Authors:
Christopher König,
Raamadaas Krishnadas,
Efe C. Balta,
Alisa Rupenyan
Abstract:
Controller tuning and parameter optimization are crucial in system design to improve closed-loop system performance. Bayesian optimization has been established as an efficient model-free controller tuning and adaptation method. However, Bayesian optimization methods are computationally expensive and therefore difficult to use in real-time critical scenarios. In this work, we propose a real-time pu…
▽ More
Controller tuning and parameter optimization are crucial in system design to improve closed-loop system performance. Bayesian optimization has been established as an efficient model-free controller tuning and adaptation method. However, Bayesian optimization methods are computationally expensive and therefore difficult to use in real-time critical scenarios. In this work, we propose a real-time purely data-driven, model-free approach for adaptive control, by online tuning low-level controller parameters. We base our algorithm on GoOSE, an algorithm for safe and sample-efficient Bayesian optimization, for handling performance and stability criteria. We introduce multiple computational and algorithmic modifications for computational efficiency and parallelization of optimization steps. We further evaluate the algorithm's performance on a real precision-motion system utilized in semiconductor industry applications by modifying the payload and reference stepsize and comparing it to an interpolated constrained optimization-based baseline approach.
△ Less
Submitted 22 April, 2024;
originally announced April 2024.
-
The Three-Dimensional Structural Configuration of the Central Retinal Vessel Trunk and Branches as a Glaucoma Biomarker
Authors:
Satish K. Panda,
Haris Cheong,
Tin A. Tun,
Thanadet Chuangsuwanich,
Aiste Kadziauskiene,
Vijayalakshmi Senthil,
Ramaswami Krishnadas,
Martin L. Buist,
Shamira Perera,
Ching-Yu Cheng,
Tin Aung,
Alexandre H. Thiery,
Michael J. A. Girard
Abstract:
Purpose: To assess whether the three-dimensional (3D) structural configuration of the central retinal vessel trunk and its branches (CRVT&B) could be used as a diagnostic marker for glaucoma. Method: We trained a deep learning network to automatically segment the CRVT&B from the B-scans of the optical coherence tomography (OCT) volume of the optic nerve head (ONH). Subsequently, two different appr…
▽ More
Purpose: To assess whether the three-dimensional (3D) structural configuration of the central retinal vessel trunk and its branches (CRVT&B) could be used as a diagnostic marker for glaucoma. Method: We trained a deep learning network to automatically segment the CRVT&B from the B-scans of the optical coherence tomography (OCT) volume of the optic nerve head (ONH). Subsequently, two different approaches were used for glaucoma diagnosis using the structural configuration of the CRVT&B as extracted from the OCT volumes. In the first approach, we aimed to provide a diagnosis using only 3D CNN and the 3D structure of the CRVT&B. For the second approach, we projected the 3D structure of the CRVT&B orthographically onto three planes to obtain 2D images, and then a 2D CNN was used for diagnosis. The segmentation accuracy was evaluated using the Dice coefficient, whereas the diagnostic accuracy was assessed using the area under the receiver operating characteristic curves (AUC). The diagnostic performance of the CRVT&B was also compared with that of retinal nerve fiber layer (RNFL) thickness. Results: Our segmentation network was able to efficiently segment retinal blood vessels from OCT scans. On a test set, we achieved a Dice coefficient of 0.81\pm0.07. The 3D and 2D diagnostic networks were able to differentiate glaucoma from non-glaucoma subjects with accuracies of 82.7% and 83.3%, respectively. The corresponding AUCs for CRVT&B were 0.89 and 0.90, higher than those obtained with RNFL thickness alone. Conclusions: Our work demonstrated that the diagnostic power of the CRVT&B is superior to that of a gold-standard glaucoma parameter, i.e., RNFL thickness. Our work also suggested that the major retinal blood vessels form a skeleton -- the configuration of which may be representative of major ONH structural changes as typically observed with the development and progression of glaucoma.
△ Less
Submitted 8 November, 2021; v1 submitted 7 November, 2021;
originally announced November 2021.
-
Describing the Structural Phenotype of the Glaucomatous Optic Nerve Head Using Artificial Intelligence
Authors:
Satish K. Panda,
Haris Cheong,
Tin A. Tun,
Sripad K. Devella,
Ramaswami Krishnadas,
Martin L. Buist,
Shamira Perera,
Ching-Yu Cheng,
Tin Aung,
Alexandre H. Thiéry,
Michaël J. A. Girard
Abstract:
The optic nerve head (ONH) typically experiences complex neural- and connective-tissue structural changes with the development and progression of glaucoma, and monitoring these changes could be critical for improved diagnosis and prognosis in the glaucoma clinic. The gold-standard technique to assess structural changes of the ONH clinically is optical coherence tomography (OCT). However, OCT is li…
▽ More
The optic nerve head (ONH) typically experiences complex neural- and connective-tissue structural changes with the development and progression of glaucoma, and monitoring these changes could be critical for improved diagnosis and prognosis in the glaucoma clinic. The gold-standard technique to assess structural changes of the ONH clinically is optical coherence tomography (OCT). However, OCT is limited to the measurement of a few hand-engineered parameters, such as the thickness of the retinal nerve fiber layer (RNFL), and has not yet been qualified as a stand-alone device for glaucoma diagnosis and prognosis applications. We argue this is because the vast amount of information available in a 3D OCT scan of the ONH has not been fully exploited. In this study we propose a deep learning approach that can: \textbf{(1)} fully exploit information from an OCT scan of the ONH; \textbf{(2)} describe the structural phenotype of the glaucomatous ONH; and that can \textbf{(3)} be used as a robust glaucoma diagnosis tool. Specifically, the structural features identified by our algorithm were found to be related to clinical observations of glaucoma. The diagnostic accuracy from these structural features was $92.0 \pm 2.3 \%$ with a sensitivity of $90.0 \pm 2.4 \% $ (at $95 \%$ specificity). By changing their magnitudes in steps, we were able to reveal how the morphology of the ONH changes as one transitions from a `non-glaucoma' to a `glaucoma' condition. We believe our work may have strong clinical implication for our understanding of glaucoma pathogenesis, and could be improved in the future to also predict future loss of vision.
△ Less
Submitted 17 December, 2020;
originally announced December 2020.
-
Towards Label-Free 3D Segmentation of Optical Coherence Tomography Images of the Optic Nerve Head Using Deep Learning
Authors:
Sripad Krishna Devalla,
Tan Hung Pham,
Satish Kumar Panda,
Liang Zhang,
Giridhar Subramanian,
Anirudh Swaminathan,
Chin Zhi Yun,
Mohan Rajan,
Sujatha Mohan,
Ramaswami Krishnadas,
Vijayalakshmi Senthil,
John Mark S. de Leon,
Tin A. Tun,
Ching-Yu Cheng,
Leopold Schmetterer,
Shamira Perera,
Tin Aung,
Alexandre H. Thiery,
Michael J. A. Girard
Abstract:
Since the introduction of optical coherence tomography (OCT), it has been possible to study the complex 3D morphological changes of the optic nerve head (ONH) tissues that occur along with the progression of glaucoma. Although several deep learning (DL) techniques have been recently proposed for the automated extraction (segmentation) and quantification of these morphological changes, the device s…
▽ More
Since the introduction of optical coherence tomography (OCT), it has been possible to study the complex 3D morphological changes of the optic nerve head (ONH) tissues that occur along with the progression of glaucoma. Although several deep learning (DL) techniques have been recently proposed for the automated extraction (segmentation) and quantification of these morphological changes, the device specific nature and the difficulty in preparing manual segmentations (training data) limit their clinical adoption. With several new manufacturers and next-generation OCT devices entering the market, the complexity in deploying DL algorithms clinically is only increasing. To address this, we propose a DL based 3D segmentation framework that is easily translatable across OCT devices in a label-free manner (i.e. without the need to manually re-segment data for each device). Specifically, we developed 2 sets of DL networks. The first (referred to as the enhancer) was able to enhance OCT image quality from 3 OCT devices, and harmonized image-characteristics across these devices. The second performed 3D segmentation of 6 important ONH tissue layers. We found that the use of the enhancer was critical for our segmentation network to achieve device independency. In other words, our 3D segmentation network trained on any of 3 devices successfully segmented ONH tissue layers from the other two devices with high performance (Dice coefficients > 0.92). With such an approach, we could automatically segment images from new OCT devices without ever needing manual segmentation data from such devices.
△ Less
Submitted 22 February, 2020;
originally announced February 2020.