A detection-task-specific deep-learning method to improve the quality of sparse-view myocardial perfusion SPECT images
Authors:
Zezhang Yang,
Zitong Yu,
Nuri Choi,
Abhinav K. Jha
Abstract:
Myocardial perfusion imaging (MPI) with single-photon emission computed tomography (SPECT) is a widely used and cost-effective diagnostic tool for coronary artery disease. However, the lengthy scanning time in this imaging procedure can cause patient discomfort, motion artifacts, and potentially inaccurate diagnoses due to misalignment between the SPECT scans and the CT-scans which are acquired fo…
▽ More
Myocardial perfusion imaging (MPI) with single-photon emission computed tomography (SPECT) is a widely used and cost-effective diagnostic tool for coronary artery disease. However, the lengthy scanning time in this imaging procedure can cause patient discomfort, motion artifacts, and potentially inaccurate diagnoses due to misalignment between the SPECT scans and the CT-scans which are acquired for attenuation compensation. Reducing projection angles is a potential way to shorten scanning time, but this can adversely impact the quality of the reconstructed images. To address this issue, we propose a detection-task-specific deep-learning method for sparse-view MPI SPECT images. This method integrates an observer loss term that penalizes the loss of anthropomorphic channel features with the goal of improving performance in perfusion defect-detection task. We observed that, on the task of detecting myocardial perfusion defects, the proposed method yielded an area under the receiver operating characteristic (ROC) curve (AUC) significantly larger than the sparse-view protocol. Further, the proposed method was observed to be able to restore the structure of the left ventricle wall, demonstrating ability to overcome sparse-sampling artifacts. Our preliminary results motivate further evaluations of the method.
△ Less
Submitted 22 April, 2025;
originally announced April 2025.
-
Using LLMs for Library Migration
Authors:
Md Mohayeminul Islam,
Ajay Kumar Jha,
May Mahmoud,
Ildar Akhmetov,
Sarah Nadi
Abstract:
Library migration is the process of replacing a used software library with another library that provides similar functionality. Manual library migration is time-consuming and error prone, as it requires developers to understand the APIs of both libraries, map them, and perform the necessary code transformations. Due to its difficulty, most of the existing automated techniques and tooling stop at t…
▽ More
Library migration is the process of replacing a used software library with another library that provides similar functionality. Manual library migration is time-consuming and error prone, as it requires developers to understand the APIs of both libraries, map them, and perform the necessary code transformations. Due to its difficulty, most of the existing automated techniques and tooling stop at the API mapping stage or support a limited set of code transformations. On the other hand, Large Language Models (LLMs) are good at generating and transforming code and finding similar code, which are necessary upstream tasks for library migration. Such capabilities suggest that LLMs may be suitable for library migration. Therefore, in this paper, we investigate the effectiveness of LLMs for migration between Python libraries. We evaluate three LLMs, LLama 3.1, GPT-4o mini, and GPT-4o on PyMigBench, where we migrate 321 real-world library migrations that include 2,989 migration-related code changes. We measure the correctness of the migration results in two ways. We first compare the LLM's migrated code with the developers' migrated code in the benchmark and then run the unit tests available in the client repositories. We find that LLama 3.1, GPT-4o mini, and GPT-4o correctly migrate 89%, 89%, and 94% of the migration-related code changes. respectively. We also find that 36%, 52% and 64% of the LLama 3.1, GPT-4o mini, and GPT-4o migrations pass the same tests that passed in the developer's migration. Overall, our results suggest that LLMs can be effective in migrating code between libraries, but we also identify cases that pose difficulties for the LLM.
△ Less
Submitted 17 April, 2025;
originally announced April 2025.
-
Nuclear Medicine Artificial Intelligence in Action: The Bethesda Report (AI Summit 2024)
Authors:
Arman Rahmim,
Tyler J. Bradshaw,
Guido Davidzon,
Joyita Dutta,
Georges El Fakhri,
Munir Ghesani,
Nicolas A. Karakatsanis,
Quanzheng Li,
Chi Liu,
Emilie Roncali,
Babak Saboury,
Tahir Yusufaly,
Abhinav K. Jha
Abstract:
The 2nd SNMMI Artificial Intelligence (AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD, on February 29 - March 1, 2024. Bringing together various community members and stakeholders, and following up on a prior successful 2022 AI Summit, the summit theme was: AI in Action. Six key topics included (i) an overview of prior and ongoing efforts by the AI task force, (ii) em…
▽ More
The 2nd SNMMI Artificial Intelligence (AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD, on February 29 - March 1, 2024. Bringing together various community members and stakeholders, and following up on a prior successful 2022 AI Summit, the summit theme was: AI in Action. Six key topics included (i) an overview of prior and ongoing efforts by the AI task force, (ii) emerging needs and tools for computational nuclear oncology, (iii) new frontiers in large language and generative models, (iv) defining the value proposition for the use of AI in nuclear medicine, (v) open science including efforts for data and model repositories, and (vi) issues of reimbursement and funding. The primary efforts, findings, challenges, and next steps are summarized in this manuscript.
△ Less
Submitted 3 June, 2024;
originally announced June 2024.
-
DEMIST: A deep-learning-based task-specific denoising approach for myocardial perfusion SPECT
Authors:
Md Ashequr Rahman,
Zitong Yu,
Richard Laforest,
Craig K. Abbey,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
There is an important need for methods to process myocardial perfusion imaging (MPI) SPECT images acquired at lower radiation dose and/or acquisition time such that the processed images improve observer performance on the clinical task of detecting perfusion defects. To address this need, we build upon concepts from model-observer theory and our understanding of the human visual system to propose…
▽ More
There is an important need for methods to process myocardial perfusion imaging (MPI) SPECT images acquired at lower radiation dose and/or acquisition time such that the processed images improve observer performance on the clinical task of detecting perfusion defects. To address this need, we build upon concepts from model-observer theory and our understanding of the human visual system to propose a Detection task-specific deep-learning-based approach for denoising MPI SPECT images (DEMIST). The approach, while performing denoising, is designed to preserve features that influence observer performance on detection tasks. We objectively evaluated DEMIST on the task of detecting perfusion defects using a retrospective study with anonymized clinical data in patients who underwent MPI studies across two scanners (N = 338). The evaluation was performed at low-dose levels of 6.25%, 12.5% and 25% and using an anthropomorphic channelized Hotelling observer. Performance was quantified using area under the receiver operating characteristics curve (AUC). Images denoised with DEMIST yielded significantly higher AUC compared to corresponding low-dose images and images denoised with a commonly used task-agnostic DL-based denoising method. Similar results were observed with stratified analysis based on patient sex and defect type. Additionally, DEMIST improved visual fidelity of the low-dose images as quantified using root mean squared error and structural similarity index metric. A mathematical analysis revealed that DEMIST preserved features that assist in detection tasks while improving the noise properties, resulting in improved observer performance. The results provide strong evidence for further clinical evaluation of DEMIST to denoise low-count images in MPI SPECT.
△ Less
Submitted 25 October, 2023; v1 submitted 7 June, 2023;
originally announced June 2023.
-
A quality assurance framework for real-time monitoring of deep learning segmentation models in radiotherapy
Authors:
Xiyao Jin,
Yao Hao,
Jessica Hilliard,
Zhehao Zhang,
Maria A. Thomas,
Hua Li,
Abhinav K. Jha,
Geoffrey D. Hugo
Abstract:
To safely deploy deep learning models in the clinic, a quality assurance framework is needed for routine or continuous monitoring of input-domain shift and the models' performance without ground truth contours. In this work, cardiac substructure segmentation was used as an example task to establish a QA framework. A benchmark dataset consisting of Computed Tomography (CT) images along with manual…
▽ More
To safely deploy deep learning models in the clinic, a quality assurance framework is needed for routine or continuous monitoring of input-domain shift and the models' performance without ground truth contours. In this work, cardiac substructure segmentation was used as an example task to establish a QA framework. A benchmark dataset consisting of Computed Tomography (CT) images along with manual cardiac delineations of 241 patients were collected, including one 'common' image domain and five 'uncommon' domains. Segmentation models were tested on the benchmark dataset for an initial evaluation of model capacity and limitations. An image domain shift detector was developed by utilizing a trained Denoising autoencoder (DAE) and two hand-engineered features. Another Variational Autoencoder (VAE) was also trained to estimate the shape quality of the auto-segmentation results. Using the extracted features from the image/segmentation pair as inputs, a regression model was trained to predict the per-patient segmentation accuracy, measured by Dice coefficient similarity (DSC). The framework was tested across 19 segmentation models to evaluate the generalizability of the entire framework.
As results, the predicted DSC of regression models achieved a mean absolute error (MAE) ranging from 0.036 to 0.046 with an averaged MAE of 0.041. When tested on the benchmark dataset, the performances of all segmentation models were not significantly affected by scanning parameters: FOV, slice thickness and reconstructions kernels. For input images with Poisson noise, CNN-based segmentation models demonstrated a decreased DSC ranging from 0.07 to 0.41, while the transformer-based model was not significantly affected.
△ Less
Submitted 19 May, 2023;
originally announced May 2023.
-
Need for Objective Task-based Evaluation of Deep Learning-Based Denoising Methods: A Study in the Context of Myocardial Perfusion SPECT
Authors:
Zitong Yu,
Md Ashequr Rahman,
Richard Laforest,
Thomas H. Schindler,
Robert J. Gropler,
Richard L. Wahl,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Artificial intelligence-based methods have generated substantial interest in nuclear medicine. An area of significant interest has been using deep-learning (DL)-based approaches for denoising images acquired with lower doses, shorter acquisition times, or both. Objective evaluation of these approaches is essential for clinical application. DL-based approaches for denoising nuclear-medicine images…
▽ More
Artificial intelligence-based methods have generated substantial interest in nuclear medicine. An area of significant interest has been using deep-learning (DL)-based approaches for denoising images acquired with lower doses, shorter acquisition times, or both. Objective evaluation of these approaches is essential for clinical application. DL-based approaches for denoising nuclear-medicine images have typically been evaluated using fidelity-based figures of merit (FoMs) such as RMSE and SSIM. However, these images are acquired for clinical tasks and thus should be evaluated based on their performance in these tasks. Our objectives were to (1) investigate whether evaluation with these FoMs is consistent with objective clinical-task-based evaluation; (2) provide a theoretical analysis for determining the impact of denoising on signal-detection tasks; (3) demonstrate the utility of virtual clinical trials (VCTs) to evaluate DL-based methods. A VCT to evaluate a DL-based method for denoising myocardial perfusion SPECT (MPS) images was conducted. The impact of DL-based denoising was evaluated using fidelity-based FoMs and AUC, which quantified performance on detecting perfusion defects in MPS images as obtained using a model observer with anthropomorphic channels. Based on fidelity-based FoMs, denoising using the considered DL-based method led to significantly superior performance. However, based on ROC analysis, denoising did not improve, and in fact, often degraded detection-task performance. The results motivate the need for objective task-based evaluation of DL-based denoising approaches. Further, this study shows how VCTs provide a mechanism to conduct such evaluations using VCTs. Finally, our theoretical treatment reveals insights into the reasons for the limited performance of the denoising approach.
△ Less
Submitted 1 April, 2023; v1 submitted 3 March, 2023;
originally announced March 2023.
-
A task-specific deep-learning-based denoising approach for myocardial perfusion SPECT
Authors:
Md Ashequr Rahman,
Zitong Yu,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Deep-learning (DL)-based methods have shown significant promise in denoising myocardial perfusion SPECT images acquired at low dose. For clinical application of these methods, evaluation on clinical tasks is crucial. Typically, these methods are designed to minimize some fidelity-based criterion between the predicted denoised image and some reference normal-dose image. However, while promising, st…
▽ More
Deep-learning (DL)-based methods have shown significant promise in denoising myocardial perfusion SPECT images acquired at low dose. For clinical application of these methods, evaluation on clinical tasks is crucial. Typically, these methods are designed to minimize some fidelity-based criterion between the predicted denoised image and some reference normal-dose image. However, while promising, studies have shown that these methods may have limited impact on the performance of clinical tasks in SPECT. To address this issue, we use concepts from the literature on model observers and our understanding of the human visual system to propose a DL-based denoising approach designed to preserve observer-related information for detection tasks. The proposed method was objectively evaluated on the task of detecting perfusion defect in myocardial perfusion SPECT images using a retrospective study with anonymized clinical data. Our results demonstrate that the proposed method yields improved performance on this detection task compared to using low-dose images. The results show that by preserving task-specific information, DL may provide a mechanism to improve observer performance in low-dose myocardial perfusion SPECT.
△ Less
Submitted 28 February, 2023;
originally announced March 2023.
-
Issues and Challenges in Applications of Artificial Intelligence to Nuclear Medicine -- The Bethesda Report (AI Summit 2022)
Authors:
Arman Rahmim,
Tyler J. Bradshaw,
Irène Buvat,
Joyita Dutta,
Abhinav K. Jha,
Paul E. Kinahan,
Quanzheng Li,
Chi Liu,
Melissa D. McCradden,
Babak Saboury,
Eliot Siegel,
John J. Sunderland,
Richard L. Wahl
Abstract:
The SNMMI Artificial Intelligence (SNMMI-AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD on March 21-22, 2022. It brought together various community members and stakeholders from academia, healthcare, industry, patient representatives, and government (NIH, FDA), and considered various key themes to envision and facilitate a bright future for routine, trustworthy use of…
▽ More
The SNMMI Artificial Intelligence (SNMMI-AI) Summit, organized by the SNMMI AI Task Force, took place in Bethesda, MD on March 21-22, 2022. It brought together various community members and stakeholders from academia, healthcare, industry, patient representatives, and government (NIH, FDA), and considered various key themes to envision and facilitate a bright future for routine, trustworthy use of AI in nuclear medicine. In what follows, essential issues, challenges, controversies and findings emphasized in the meeting are summarized.
△ Less
Submitted 7 November, 2022;
originally announced November 2022.
-
UAV-based Visual Remote Sensing for Automated Building Inspection
Authors:
Kushagra Srivastava,
Dhruv Patel,
Aditya Kumar Jha,
Mohhit Kumar Jha,
Jaskirat Singh,
Ravi Kiran Sarvadevabhatla,
Pradeep Kumar Ramancharla,
Harikumar Kandath,
K. Madhava Krishna
Abstract:
Unmanned Aerial Vehicle (UAV) based remote sensing system incorporated with computer vision has demonstrated potential for assisting building construction and in disaster management like damage assessment during earthquakes. The vulnerability of a building to earthquake can be assessed through inspection that takes into account the expected damage progression of the associated component and the co…
▽ More
Unmanned Aerial Vehicle (UAV) based remote sensing system incorporated with computer vision has demonstrated potential for assisting building construction and in disaster management like damage assessment during earthquakes. The vulnerability of a building to earthquake can be assessed through inspection that takes into account the expected damage progression of the associated component and the component's contribution to structural system performance. Most of these inspections are done manually, leading to high utilization of manpower, time, and cost. This paper proposes a methodology to automate these inspections through UAV-based image data collection and a software library for post-processing that helps in estimating the seismic structural parameters. The key parameters considered here are the distances between adjacent buildings, building plan-shape, building plan area, objects on the rooftop and rooftop layout. The accuracy of the proposed methodology in estimating the above-mentioned parameters is verified through field measurements taken using a distance measuring sensor and also from the data obtained through Google Earth. Additional details and code can be accessed from https://uvrsabi.github.io/ .
△ Less
Submitted 27 September, 2022;
originally announced September 2022.
-
Characterizing Python Library Migrations
Authors:
Mohayeminul Islam,
Ajay Kumar Jha,
Ildar Akhmetov,
Sarah Nadi
Abstract:
Developers heavily rely on Application Programming Interfaces (APIs) from libraries to build their software. As software evolves, developers may need to replace the used libraries with alternate libraries, a process known as library migration. Doing this manually can be tedious, time-consuming, and prone to errors. Automated migration techniques can help alleviate some of this burden. However, des…
▽ More
Developers heavily rely on Application Programming Interfaces (APIs) from libraries to build their software. As software evolves, developers may need to replace the used libraries with alternate libraries, a process known as library migration. Doing this manually can be tedious, time-consuming, and prone to errors. Automated migration techniques can help alleviate some of this burden. However, designing effective automated migration techniques requires understanding the types of code changes required to transform client code that used the old library to the new library. This paper contributes an empirical study that provides a holistic view of Python library migrations, both in terms of the code changes required in a migration and the typical development effort involved. We manually label 3,096 migration-related code changes in 335 Python library migrations from 311 client repositories spanning 141 library pairs from 35 domains. Based on our labeled data, we derive a taxonomy for describing migration-related code changes, PyMigTax. Leveraging PyMigTax and our labeled data, we investigate various characteristics of Python library migrations, such as the types of program elements and properties of API mappings, the combinations of types of migration-related code changes in a migration, and the typical development effort required for a migration. Our findings highlight various potential shortcomings of current library migration tools. For example, we find that 40% of library pairs have API mappings that involve non-function program elements, while most library migration techniques typically assume that function calls from the source library will map into (one or more) function calls from the target library. As an approximation for the development effort involved, we find that, on average, a developer needs to learn about 4 APIs and 2 API mappings to perform a migration, and ... (truncated)
△ Less
Submitted 29 January, 2024; v1 submitted 3 July, 2022;
originally announced July 2022.
-
Investigating the limited performance of a deep-learning-based SPECT denoising approach: An observer-study-based characterization
Authors:
Zitong Yu,
Md Ashequr Rahman,
Abhinav K. Jha
Abstract:
Multiple objective assessment of image-quality-based studies have reported that several deep-learning-based denoising methods show limited performance on signal-detection tasks. Our goal was to investigate the reasons for this limited performance. To achieve this goal, we conducted a task-based characterization of a DL-based denoising approach for individual signal properties. We conducted this st…
▽ More
Multiple objective assessment of image-quality-based studies have reported that several deep-learning-based denoising methods show limited performance on signal-detection tasks. Our goal was to investigate the reasons for this limited performance. To achieve this goal, we conducted a task-based characterization of a DL-based denoising approach for individual signal properties. We conducted this study in the context of evaluating a DL-based approach for denoising SPECT images. The training data consisted of signals of different sizes and shapes within a clustered-lumpy background, imaged with a 2D parallel-hole-collimator SPECT system. The projections were generated at normal and 20% low count level, both of which were reconstructed using an OSEM algorithm. A CNN-based denoiser was trained to process the low-count images. The performance of this CNN was characterized for five different signal sizes and four different SBR by designing each evaluation as an SKE/BKS signal-detection task. Performance on this task was evaluated using an anthropomorphic CHO. As in previous studies, we observed that the DL-based denoising method did not improve performance on signal-detection tasks. Evaluation using the idea of observer-study-based characterization demonstrated that the DL-based denoising approach did not improve performance on the signal-detection task for any of the signal types. Overall, these results provide new insights on the performance of the DL-based denoising approach as a function of signal size and contrast. More generally, the observer study-based characterization provides a mechanism to evaluate the sensitivity of the method to specific object properties and may be explored as analogous to characterizations such as modulation transfer function for linear systems. Finally, this work underscores the need for objective task-based evaluation of DL-based denoising approaches.
△ Less
Submitted 3 March, 2022;
originally announced March 2022.
-
A Bayesian approach to tissue-fraction estimation for oncological PET segmentation
Authors:
Ziping Liu,
Joyce C. Mhlanga,
Richard Laforest,
Paul-Robert Derenoncourt,
Barry A. Siegel,
Abhinav K. Jha
Abstract:
Tumor segmentation in oncological PET is challenging, a major reason being the partial-volume effects that arise due to low system resolution and finite voxel size. The latter results in tissue-fraction effects, i.e. voxels contain a mixture of tissue classes. Conventional segmentation methods are typically designed to assign each voxel in the image as belonging to a certain tissue class. Thus, th…
▽ More
Tumor segmentation in oncological PET is challenging, a major reason being the partial-volume effects that arise due to low system resolution and finite voxel size. The latter results in tissue-fraction effects, i.e. voxels contain a mixture of tissue classes. Conventional segmentation methods are typically designed to assign each voxel in the image as belonging to a certain tissue class. Thus, these methods are inherently limited in modeling tissue-fraction effects. To address the challenge of accounting for partial-volume effects, and in particular, tissue-fraction effects, we propose a Bayesian approach to tissue-fraction estimation for oncological PET segmentation. Specifically, this Bayesian approach estimates the posterior mean of fractional volume that the tumor occupies within each voxel of the image. The proposed method, implemented using a deep-learning-based technique, was first evaluated using clinically realistic 2-D simulation studies with known ground truth, in the context of segmenting the primary tumor in PET images of patients with lung cancer. The evaluation studies demonstrated that the method accurately estimated the tumor-fraction areas and significantly outperformed widely used conventional PET segmentation methods, including a U-net-based method, on the task of segmenting the tumor. In addition, the proposed method was relatively insensitive to partial-volume effects and yielded reliable tumor segmentation for different clinical-scanner configurations. The method was then evaluated using clinical images of patients with stage IIB/III non-small cell lung cancer from ACRIN 6668/RTOG 0235 multi-center clinical trial. Here, the results showed that the proposed method significantly outperformed all other considered methods and yielded accurate tumor segmentation on patient images with Dice similarity coefficient (DSC) of 0.82 (95 % CI: [0.78, 0.86]).
△ Less
Submitted 27 May, 2022; v1 submitted 29 February, 2020;
originally announced March 2020.