Social Virtual Reality (VR), where people meet in virtual spaces via 3D avatars, is used by children and adults alike. Children experience new forms of harassment in social VR where it is often inaccessible to parental oversight. To date, there is limited understanding of how parents and non-parent adults within the child social VR ecosystem perceive the appropriateness of social VR for different…
▽ More
Social Virtual Reality (VR), where people meet in virtual spaces via 3D avatars, is used by children and adults alike. Children experience new forms of harassment in social VR where it is often inaccessible to parental oversight. To date, there is limited understanding of how parents and non-parent adults within the child social VR ecosystem perceive the appropriateness of social VR for different age groups and the measures in place to safeguard children. We present results of a mixed-methods questionnaire (N=149 adults, including 79 parents) focusing on encounters with children in social VR and perspectives towards children's use of social VR. We draw novel insights on the frequency of social VR use by children under 13 and current use of, and future aspirations for, child protection interventions. Compared to non-parent adults, parents familiar with social VR propose lower minimum ages and are more likely to allow social VR without supervision. Adult users experience immaturity from children in social VR, while children face abuse, encounter age-inappropriate behaviours and self-disclose to adults. We present directions to enhance the safety of social VR through pre-planned controls, real-time oversight, post-event insight and the need for evidence-based guidelines to support parents and platforms around age-appropriate interventions.
△ Less
Submitted 19 March, 2025;
originally announced March 2025.
Lumen Shape Reconstruction using a Soft Robotic Balloon Catheter and Electrical Impedance Tomography
Authors:
James Avery,
Mark Runciman,
Cristina Fiani,
Elena Monfort Sanchez,
Saina Akhond,
Zhuang Liu,
Kirill Aristovich,
George Mylonas
Abstract:
Incorrectly sized balloon catheters can lead to increased post-surgical complications, yet even with preoperative imaging, correct selection remains a challenge. With limited feedback during surgery, it is difficult to verify correct deployment. We propose the use of integrated impedance measurements and Electrical Impedance Tomography (EIT) imaging to assess the deformation of the balloon and det…
▽ More
Incorrectly sized balloon catheters can lead to increased post-surgical complications, yet even with preoperative imaging, correct selection remains a challenge. With limited feedback during surgery, it is difficult to verify correct deployment. We propose the use of integrated impedance measurements and Electrical Impedance Tomography (EIT) imaging to assess the deformation of the balloon and determine the size and shape of the surrounding lumen. Previous work using single impedance measurements, or pressure data and analytical models, whilst demonstrating high sizing accuracy, have assumed a circular cross section. Here we extend these methods by adding a multitude of electrodes to detect elliptical and occluded lumen and obtain EIT images to localise deformations. Using a 14 Fr (5.3 mm) catheter as an example, numerical simulations were performed to find the optimal electrode configuration of two rings of 8 electrodes spaced 10 mm apart. The simulations predicted that the maximum detectable aspect ratio decreased from 0.9 for a 14mm balloon to 0.5 at 30mm. The sizing and ellipticity detection results were verified experimentally. A prototype robotic balloon catheter was constructed to automatically inflate a compliant balloon while simultaneously recording EIT and pressure data. Data were collected in experiments replicating stenotic vessels with an elliptical and asymmetrical profile, and the widening of a lumen during angioplasty. After calibration, the system was able to correctly localise the occlusion and detect aspect ratios of 0.75. EIT images further localised the occlusion and visualised the dilation of the lumen during balloon inflation.
△ Less
Submitted 23 August, 2022; v1 submitted 25 July, 2022;
originally announced July 2022.