-
Impact of Electrode Position on Forearm Orientation Invariant Hand Gesture Recognition
Authors:
Md. Johirul Islam,
Umme Rumman,
Arifa Ferdousi,
Md. Sarwar Pervez,
Iffat Ara,
Shamim Ahmad,
Fahmida Haque,
Sawal Hamid,
Md. Ali,
Kh Shahriya Zaman,
Mamun Bin Ibne Reaz,
Mustafa Habib Chowdhury,
Md. Rezaul Islam
Abstract:
Objective: Variation of forearm orientation is one of the crucial factors that drastically degrades the forearm orientation invariant hand gesture recognition performance or the degree of freedom and limits the successful commercialization of myoelectric prosthetic hand or electromyogram (EMG) signal-based human-computer interfacing devices. This study investigates the impact of surface EMG electr…
▽ More
Objective: Variation of forearm orientation is one of the crucial factors that drastically degrades the forearm orientation invariant hand gesture recognition performance or the degree of freedom and limits the successful commercialization of myoelectric prosthetic hand or electromyogram (EMG) signal-based human-computer interfacing devices. This study investigates the impact of surface EMG electrode positions (elbow and forearm) on forearm orientation invariant hand gesture recognition. Methods: The study has been performed over 19 intact limbed subjects, considering 12 daily living hand gestures. The quality of the EMG signal is confirmed in terms of three indices. Then, the recognition performance is evaluated and validated by considering three training strategies, six feature extraction methods, and three classifiers. Results: The forearm electrode position provides comparable to or better EMG signal quality considering three indices. In this research, the forearm electrode position achieves up to 5.35% improved forearm orientation invariant hand gesture recognition performance compared to the elbow electrode position. The obtained performance is validated by considering six feature extraction methods, three classifiers, and real-time experiments. In addition, the forearm electrode position shows its robustness with the existence of recent works, considering recognition performance, investigated gestures, the number of channels, the dimensionality of feature space, and the number of subjects. Conclusion: The forearm electrode position can be the best choice for getting improved forearm orientation invariant hand gesture recognition performance. Significance: The performance of myoelectric prosthesis and human-computer interfacing devices can be improved with this optimized electrode position.
△ Less
Submitted 16 September, 2024;
originally announced October 2024.
-
FORS-EMG: A Novel sEMG Dataset for Hand Gesture Recognition Across Multiple Forearm Orientations
Authors:
Umme Rumman,
Arifa Ferdousi,
Bipin Saha,
Md. Sazzad Hossain,
Md. Johirul Islam,
Shamim Ahmad,
Mamun Bin Ibne Reaz,
Md. Rezaul Islam
Abstract:
Surface electromyography (sEMG) signals hold significant potential for gesture recognition and robust prosthetic hand development. However, sEMG signals are affected by various physiological and dynamic factors, including forearm orientation, electrode displacement, and limb position. Most existing sEMG datasets lack these dynamic considerations. This study introduces a novel multichannel sEMG dat…
▽ More
Surface electromyography (sEMG) signals hold significant potential for gesture recognition and robust prosthetic hand development. However, sEMG signals are affected by various physiological and dynamic factors, including forearm orientation, electrode displacement, and limb position. Most existing sEMG datasets lack these dynamic considerations. This study introduces a novel multichannel sEMG dataset to evaluate commonly used hand gestures across three distinct forearm orientations. The dataset was collected from nineteen able-bodied subjects performing twelve hand gestures in three forearm orientations--supination, rest, and pronation. Eight MFI EMG electrodes were strategically placed at the elbow and mid-forearm to record high-quality EMG signals. Signal quality was validated through Signal-to-Noise Ratio (SNR) and Signal-to-Motion artifact ratio (SMR) metrics. Hand gesture classification performance across forearm orientations was evaluated using machine learning classifiers, including LDA, SVM, and KNN, alongside five feature extraction methods: TDD, TSD, FTDD, AR-RMS, and SNTDF. Furthermore, deep learning models such as 1D CNN, RNN, LSTM, and hybrid architectures were employed for a comprehensive analysis. Notably, the LDA classifier achieved the highest F1 score of 88.58\% with the SNTDF feature set when trained on hand gesture data of resting and tested across gesture data of all orientations. The promising results from extensive analyses underscore the proposed dataset's potential as a benchmark for advancing gesture recognition technologies, clinical sEMG research, and human-computer interaction applications. The dataset is publicly available in MATLAB format. Dataset: \url{https://www.kaggle.com/datasets/ummerummanchaity/fors-emg-a-novel-semg-dataset}
△ Less
Submitted 26 November, 2024; v1 submitted 3 September, 2024;
originally announced September 2024.
-
The performance evaluation of IEEE 802.16 physical layer in the basis of bit error rate considering reference channel models
Authors:
Arifa Ferdousi,
Farhana Enam,
Sadeque Reza Khan
Abstract:
Fixed Broadband Wireless Access is a promising technology which can offer high speed data rate from transmitting end to customer end which can offer high speed text, voice, and video data. IEEE 802.16 WirelessMAN is a standard that specifies medium access control layer and a set of PHY layer to fixed and mobile BWA in broad range of frequencies and it supports equipment manufacturers due to its ro…
▽ More
Fixed Broadband Wireless Access is a promising technology which can offer high speed data rate from transmitting end to customer end which can offer high speed text, voice, and video data. IEEE 802.16 WirelessMAN is a standard that specifies medium access control layer and a set of PHY layer to fixed and mobile BWA in broad range of frequencies and it supports equipment manufacturers due to its robust performance in multipath environment. Consequently WiMAX forum has adopted this version to develop the network world wide. In this paper the performance of IEEE 802.16 OFDM PHY Layer has been investigated by using the simulation model in Matlab. The Stanford University Interim (SUI) channel models are selected for the performance evaluation of this standard. The Ideal Channel estimation is considered in this work and the performance evaluation is observed in the basis of BER.
△ Less
Submitted 25 December, 2013;
originally announced December 2013.
-
Voltage Temperature Monitoring System (VTMS) for a BTS Room
Authors:
Sadeque Reza Khan,
Siddique Reza Khan,
Arifa Ferdousi
Abstract:
Although Cellular communication is getting more and more popular in our country present days, but its network improvement is hampered by the crysis of electricity. The recent decision of present Government is that they will not provide any electricity from the grid to any new BTS rooms of any Celluler operator companies like Grammen Phone, Robi, Airtel etc. These companies have to develop their ow…
▽ More
Although Cellular communication is getting more and more popular in our country present days, but its network improvement is hampered by the crysis of electricity. The recent decision of present Government is that they will not provide any electricity from the grid to any new BTS rooms of any Celluler operator companies like Grammen Phone, Robi, Airtel etc. These companies have to develop their own power stations either by using generators or by developing solar plants. Now a days most of the BTS rooms, that the cellular operators are installing with a generator and 48 volt battery backup. So for the synchronisation of the operation of PDB, Generator and battery, they require a device called Voltage Temperature Monitoring System or VTMS. It is a Microcontroller based controlling unit which controlls the operation of generator and battery when PDB in not available in the BTS room.
△ Less
Submitted 19 December, 2012;
originally announced December 2012.