An Extended Generalized Prandtl-Ishlinskii Hysteresis Model for I2RIS Robot
Authors:
Yiyao Yue,
Mojtaba Esfandiari,
Pengyuan Du,
Peter Gehlbach,
Makoto Jinno,
Adnan Munawar,
Peter Kazanzides,
Iulian Iordachita
Abstract:
Retinal surgery requires extreme precision due to constrained anatomical spaces in the human retina. To assist surgeons achieve this level of accuracy, the Improved Integrated Robotic Intraocular Snake (I2RIS) with dexterous capability has been developed. However, such flexible tendon-driven robots often suffer from hysteresis problems, which significantly challenges precise control and positionin…
▽ More
Retinal surgery requires extreme precision due to constrained anatomical spaces in the human retina. To assist surgeons achieve this level of accuracy, the Improved Integrated Robotic Intraocular Snake (I2RIS) with dexterous capability has been developed. However, such flexible tendon-driven robots often suffer from hysteresis problems, which significantly challenges precise control and positioning. In particular, we observed multi-stage hysteresis phenomena in the small-scale I2RIS. In this paper, we propose an Extended Generalized Prandtl-Ishlinskii (EGPI) model to increase the fitting accuracy of the hysteresis. The model incorporates a novel switching mechanism that enables it to describe multi-stage hysteresis in the regions of monotonic input. Experimental validation on I2RIS data demonstrate that the EGPI model outperforms the conventional Generalized Prandtl-Ishlinskii (GPI) model in terms of RMSE, NRMSE, and MAE across multiple motor input directions. The EGPI model in our study highlights the potential in modeling multi-stage hysteresis in minimally invasive flexible robots.
△ Less
Submitted 16 April, 2025;
originally announced April 2025.
-
Deep Learning-Enhanced Robotic Subretinal Injection with Real-Time Retinal Motion Compensation
Authors:
Tianle Wu,
Mojtaba Esfandiari,
Peiyao Zhang,
Russell H. Taylor,
Peter Gehlbach,
Iulian Iordachita
Abstract:
Subretinal injection is a critical procedure for delivering therapeutic agents to treat retinal diseases such as age-related macular degeneration (AMD). However, retinal motion caused by physiological factors such as respiration and heartbeat significantly impacts precise needle positioning, increasing the risk of retinal pigment epithelium (RPE) damage. This paper presents a fully autonomous robo…
▽ More
Subretinal injection is a critical procedure for delivering therapeutic agents to treat retinal diseases such as age-related macular degeneration (AMD). However, retinal motion caused by physiological factors such as respiration and heartbeat significantly impacts precise needle positioning, increasing the risk of retinal pigment epithelium (RPE) damage. This paper presents a fully autonomous robotic subretinal injection system that integrates intraoperative optical coherence tomography (iOCT) imaging and deep learning-based motion prediction to synchronize needle motion with retinal displacement. A Long Short-Term Memory (LSTM) neural network is used to predict internal limiting membrane (ILM) motion, outperforming a Fast Fourier Transform (FFT)-based baseline model. Additionally, a real-time registration framework aligns the needle tip position with the robot's coordinate frame. Then, a dynamic proportional speed control strategy ensures smooth and adaptive needle insertion. Experimental validation in both simulation and ex vivo open-sky porcine eyes demonstrates precise motion synchronization and successful subretinal injections. The experiment achieves a mean tracking error below 16.4 μm in pre-insertion phases. These results show the potential of AI-driven robotic assistance to improve the safety and accuracy of retinal microsurgery.
△ Less
Submitted 4 April, 2025;
originally announced April 2025.
-
Model Predictive Path Integral Control of I2RIS Robot Using RBF Identifier and Extended Kalman Filter
Authors:
Mojtaba Esfandiari,
Pengyuan Du,
Haochen Wei,
Peter Gehlbach,
Adnan Munawar,
Peter Kazanzides,
Iulian Iordachita
Abstract:
Modeling and controlling cable-driven snake robots is a challenging problem due to nonlinear mechanical properties such as hysteresis, variable stiffness, and unknown friction between the actuation cables and the robot body. This challenge is more significant for snake robots in ophthalmic surgery applications, such as the Improved Integrated Robotic Intraocular Snake (I$^2$RIS), given its small s…
▽ More
Modeling and controlling cable-driven snake robots is a challenging problem due to nonlinear mechanical properties such as hysteresis, variable stiffness, and unknown friction between the actuation cables and the robot body. This challenge is more significant for snake robots in ophthalmic surgery applications, such as the Improved Integrated Robotic Intraocular Snake (I$^2$RIS), given its small size and lack of embedded sensory feedback. Data-driven models take advantage of global function approximations, reducing complicated analytical models' challenge and computational costs. However, their performance might deteriorate in case of new data unseen in the training phase. Therefore, adding an adaptation mechanism might improve these models' performance during snake robots' interactions with unknown environments. In this work, we applied a model predictive path integral (MPPI) controller on a data-driven model of the I$^2$RIS based on the Gaussian mixture model (GMM) and Gaussian mixture regression (GMR). To analyze the performance of the MPPI in unseen robot-tissue interaction situations, unknown external disturbances and environmental loads are simulated and added to the GMM-GMR model. These uncertainties of the robot model are then identified online using a radial basis function (RBF) whose weights are updated using an extended Kalman filter (EKF). Simulation results demonstrated the robustness of the optimal control solutions of the MPPI algorithm and its computational superiority over a conventional model predictive control (MPC) algorithm.
△ Less
Submitted 18 March, 2025;
originally announced March 2025.
-
Towards Motion Compensation in Autonomous Robotic Subretinal Injections
Authors:
Demir Arikan,
Peiyao Zhang,
Michael Sommersperger,
Shervin Dehghani,
Mojtaba Esfandiari,
Russel H. Taylor,
M. Ali Nasseri,
Peter Gehlbach,
Nassir Navab,
Iulian Iordachita
Abstract:
Exudative (wet) age-related macular degeneration (AMD) is a leading cause of vision loss in older adults, typically treated with intravitreal injections. Emerging therapies, such as subretinal injections of stem cells, gene therapy, small molecules and RPE cells require precise delivery to avoid damaging delicate retinal structures. Robotic systems can potentially offer the necessary precision for…
▽ More
Exudative (wet) age-related macular degeneration (AMD) is a leading cause of vision loss in older adults, typically treated with intravitreal injections. Emerging therapies, such as subretinal injections of stem cells, gene therapy, small molecules and RPE cells require precise delivery to avoid damaging delicate retinal structures. Robotic systems can potentially offer the necessary precision for these procedures. This paper presents a novel approach for motion compensation in robotic subretinal injections, utilizing real time Optical Coherence Tomography (OCT). The proposed method leverages B$^5$-scans, a rapid acquisition of small-volume OCT data, for dynamic tracking of retinal motion along the Z-axis, compensating for physiological movements such as breathing and heartbeat. Validation experiments on ex vivo porcine eyes revealed challenges in maintaining a consistent tool-to-retina distance, with deviations of up to 200 $μm$ for 100 $μm$ amplitude motions and over 80 $μm$ for 25 $μm$ amplitude motions over one minute. Subretinal injections faced additional difficulties, with phase shifts causing the needle to move off-target and inject into the vitreous. These results highlight the need for improved motion prediction and horizontal stability to enhance the accuracy and safety of robotic subretinal procedures.
△ Less
Submitted 11 March, 2025; v1 submitted 27 November, 2024;
originally announced November 2024.
-
Real-time Deformation-aware Control for Autonomous Robotic Subretinal Injection under iOCT Guidance
Authors:
Demir Arikan,
Peiyao Zhang,
Michael Sommersperger,
Shervin Dehghani,
Mojtaba Esfandiari,
Russel H. Taylor,
M. Ali Nasseri,
Peter Gehlbach,
Nassir Navab,
Iulian Iordachita
Abstract:
Robotic platforms provide consistent and precise tool positioning that significantly enhances retinal microsurgery. Integrating such systems with intraoperative optical coherence tomography (iOCT) enables image-guided robotic interventions, allowing autonomous performance of advanced treatments, such as injecting therapeutic agents into the subretinal space. However, tissue deformations due to too…
▽ More
Robotic platforms provide consistent and precise tool positioning that significantly enhances retinal microsurgery. Integrating such systems with intraoperative optical coherence tomography (iOCT) enables image-guided robotic interventions, allowing autonomous performance of advanced treatments, such as injecting therapeutic agents into the subretinal space. However, tissue deformations due to tool-tissue interactions constitute a significant challenge in autonomous iOCT-guided robotic subretinal injections. Such interactions impact correct needle positioning and procedure outcomes. This paper presents a novel method for autonomous subretinal injection under iOCT guidance that considers tissue deformations during the insertion procedure. The technique is achieved through real-time segmentation and 3D reconstruction of the surgical scene from densely sampled iOCT B-scans, which we refer to as B${^5}$-scans. Using B${^5}$-scans we monitor the position of the instrument relative to a virtual target layer between the ILM and RPE. Our experiments on ex vivo porcine eyes demonstrate dynamic adjustment of the insertion depth and overall improved accuracy in needle positioning compared to prior autonomous insertion approaches. Compared to a 35% success rate in subretinal bleb generation with previous approaches, our method reliably created subretinal blebs in 90% our experiments.
△ Less
Submitted 11 March, 2025; v1 submitted 10 November, 2024;
originally announced November 2024.
-
AdaBoost-Based Efficient Channel Estimation and Data Detection in One-Bit Massive MIMO
Authors:
Majdoddin Esfandiari,
Sergiy A. Vorobyov,
Robert W. Heath Jr
Abstract:
The use of one-bit analog-to-digital converter (ADC) has been considered as a viable alternative to high resolution counterparts in realizing and commercializing massive multiple-input multiple-output (MIMO) systems. However, the issue of discarding the amplitude information by one-bit quantizers has to be compensated. Thus, carefully tailored methods need to be developed for one-bit channel estim…
▽ More
The use of one-bit analog-to-digital converter (ADC) has been considered as a viable alternative to high resolution counterparts in realizing and commercializing massive multiple-input multiple-output (MIMO) systems. However, the issue of discarding the amplitude information by one-bit quantizers has to be compensated. Thus, carefully tailored methods need to be developed for one-bit channel estimation and data detection as the conventional ones cannot be used. To address these issues, the problems of one-bit channel estimation and data detection for MIMO orthogonal frequency division multiplexing (OFDM) system that operates over uncorrelated frequency selective channels are investigated here. We first develop channel estimators that exploit Gaussian discriminant analysis (GDA) classifier and approximated versions of it as the so-called weak classifiers in an adaptive boosting (AdaBoost) approach. Particularly, the combination of the approximated GDA classifiers with AdaBoost offers the benefit of scalability with the linear order of computations, which is critical in massive MIMO-OFDM systems. We then take advantage of the same idea for proposing the data detectors. Numerical results validate the efficiency of the proposed channel estimators and data detectors compared to other methods. They show comparable/better performance to that of the state-of-the-art methods, but require dramatically lower computational complexities and run times.
△ Less
Submitted 1 March, 2024;
originally announced March 2024.
-
Bimanual Manipulation of Steady Hand Eye Robots with Adaptive Sclera Force Control: Cooperative vs. Teleoperation Strategies
Authors:
Mojtaba Esfandiari,
Peter Gehlbach,
Russell H. Taylor,
Iulian Iordachita
Abstract:
Performing retinal vein cannulation (RVC) as a potential treatment for retinal vein occlusion (RVO) without the assistance of a surgical robotic system is very challenging to do safely. The main limitation is the physiological hand tremor of surgeons. Robot-assisted eye surgery technology may resolve the problems of hand tremors and fatigue and improve the safety and precision of RVC. The Steady-H…
▽ More
Performing retinal vein cannulation (RVC) as a potential treatment for retinal vein occlusion (RVO) without the assistance of a surgical robotic system is very challenging to do safely. The main limitation is the physiological hand tremor of surgeons. Robot-assisted eye surgery technology may resolve the problems of hand tremors and fatigue and improve the safety and precision of RVC. The Steady-Hand Eye Robot (SHER) is an admittance-based robotic system that can filter out hand tremors and enables ophthalmologists to manipulate a surgical instrument inside the eye cooperatively. However, the admittance-based cooperative control mode does not safely minimize the contact force between the surgical instrument and the sclera to prevent tissue damage. Additionally, features like haptic feedback or hand motion scaling, which can improve the safety and precision of surgery, require a teleoperation control framework. This work presents a bimanual adaptive teleoperation (BMAT) control framework using SHER 2.0 and SHER 2.1 robotic systems. We integrate them with an adaptive force control (AFC) algorithm to automatically minimize the tool-sclera interaction force. The scleral forces are measured using two fiber Bragg grating (FBG)-based force-sensing tools. We compare the performance of the BMAT mode with a bimanual adaptive cooperative (BMAC) mode in a vessel-following experiment under a surgical microscope. Experimental results demonstrate the effectiveness of the proposed BMAT control framework in performing a safe bimanual telemanipulation of the eye without over-stretching it, even in the absence of registration between the two robots.
△ Less
Submitted 5 August, 2024; v1 submitted 28 February, 2024;
originally announced February 2024.
-
Cooperative vs. Teleoperation Control of the Steady Hand Eye Robot with Adaptive Sclera Force Control: A Comparative Study
Authors:
Mojtaba Esfandiari,
Ji Woong Kim,
Botao Zhao,
Golchehr Amirkhani,
Muhammad Hadi,
Peter Gehlbach,
Russell H. Taylor,
Iulian Iordachita
Abstract:
A surgeon's physiological hand tremor can significantly impact the outcome of delicate and precise retinal surgery, such as retinal vein cannulation (RVC) and epiretinal membrane peeling. Robot-assisted eye surgery technology provides ophthalmologists with advanced capabilities such as hand tremor cancellation, hand motion scaling, and safety constraints that enable them to perform these otherwise…
▽ More
A surgeon's physiological hand tremor can significantly impact the outcome of delicate and precise retinal surgery, such as retinal vein cannulation (RVC) and epiretinal membrane peeling. Robot-assisted eye surgery technology provides ophthalmologists with advanced capabilities such as hand tremor cancellation, hand motion scaling, and safety constraints that enable them to perform these otherwise challenging and high-risk surgeries with high precision and safety. Steady-Hand Eye Robot (SHER) with cooperative control mode can filter out surgeon's hand tremor, yet another important safety feature, that is, minimizing the contact force between the surgical instrument and sclera surface for avoiding tissue damage cannot be met in this control mode. Also, other capabilities, such as hand motion scaling and haptic feedback, require a teleoperation control framework. In this work, for the first time, we implemented a teleoperation control mode incorporated with an adaptive sclera force control algorithm using a PHANTOM Omni haptic device and a force-sensing surgical instrument equipped with Fiber Bragg Grating (FBG) sensors attached to the SHER 2.1 end-effector. This adaptive sclera force control algorithm allows the robot to dynamically minimize the tool-sclera contact force. Moreover, for the first time, we compared the performance of the proposed adaptive teleoperation mode with the cooperative mode by conducting a vessel-following experiment inside an eye phantom under a microscope.
△ Less
Submitted 4 December, 2023;
originally announced December 2023.
-
Human-Robot Interaction in Retinal Surgery: A Comparative Study of Serial and Parallel Cooperative Robots
Authors:
Botao Zhao,
Mojtaba Esfandiari,
David E. Usevitch,
Peter Gehlbach,
Iulian Iordachita
Abstract:
Cooperative robots for intraocular surgery allow surgeons to perform vitreoretinal surgery with high precision and stability. Several robot structural designs have shown capabilities to perform these surgeries. This research investigates the comparative performance of a serial and parallel cooperative-controlled robot in completing a retinal vessel-following task, with a focus on human-robot inter…
▽ More
Cooperative robots for intraocular surgery allow surgeons to perform vitreoretinal surgery with high precision and stability. Several robot structural designs have shown capabilities to perform these surgeries. This research investigates the comparative performance of a serial and parallel cooperative-controlled robot in completing a retinal vessel-following task, with a focus on human-robot interaction performance and user experience. Our results indicate that despite differences in robot structure and interaction forces and torques, the two robots exhibited similar levels of performance in terms of general robot-to-patient interaction and average operating time. These findings have implications for the development and implementation of surgical robotics, suggesting that both serial and parallel cooperative-controlled robots can be effective for vitreoretinal surgery tasks.
△ Less
Submitted 31 March, 2023;
originally announced April 2023.
-
Using an Improved Output Feedback MPC Approach for Developing a Haptic Virtual Training System
Authors:
Soroush Sadeghnejad,
Farshad Khadivar,
Mojtaba Esfandiari,
Golchehr Amirkhani,
Hamed Moradi,
Farzam Farahmand,
Gholamreza Vossoughi
Abstract:
Haptic training simulators generally consist of three major components, namely a human operator, a haptic interface, and a virtual environment. Appropriate dynamic modeling of each of these components can have far-reaching implications for the whole system's performance improvement in terms of transparency, the analogy to the real environment, and stability. In this paper, we developed a virtual-b…
▽ More
Haptic training simulators generally consist of three major components, namely a human operator, a haptic interface, and a virtual environment. Appropriate dynamic modeling of each of these components can have far-reaching implications for the whole system's performance improvement in terms of transparency, the analogy to the real environment, and stability. In this paper, we developed a virtual-based haptic training simulator for Endoscopic Sinus Surgery (ESS) by doing a dynamic characterization of the phenomenological sinus tissue fracture in the virtual environment, using an input-constrained linear parametric variable model. A parallel robot manipulator equipped with a calibrated force sensor is employed as a haptic interface. A lumped five-parameter single-degree-of-freedom mass-stiffness-damping impedance model is assigned to the operator's arm dynamic. A robust online output feedback quasi-min-max model predictive control (MPC) framework is proposed to stabilize the system during the switching between the piecewise linear dynamics of the virtual environment. The simulations and the experimental results demonstrate the effectiveness of the proposed control algorithm in terms of robustness and convergence to the desired impedance quantities.
△ Less
Submitted 12 March, 2023;
originally announced March 2023.
-
A Virtual-Based Haptic Endoscopic Sinus Surgery (ESS) Training System: from Development to Validation
Authors:
Soroush Sadeghnejad,
Mojtaba Esfandiari,
Farshad Khadivar
Abstract:
Simulated training platforms offer a suitable avenue for surgical students and professionals to build and improve upon their skills, without the hassle of traditional training methods. To enhance the degree of realistic interaction paradigms of training simulators, great work has been done to both model simulated anatomy in more realistic fashion, as well as providing appropriate haptic feedback t…
▽ More
Simulated training platforms offer a suitable avenue for surgical students and professionals to build and improve upon their skills, without the hassle of traditional training methods. To enhance the degree of realistic interaction paradigms of training simulators, great work has been done to both model simulated anatomy in more realistic fashion, as well as providing appropriate haptic feedback to the trainee. As such, this chapter seeks to discuss the ongoing research being conducted on haptic feedback-incorporated simulators specifically for Endoscopic Sinus Surgery (ESS). This chapter offers a brief comparative analysis of some EES simulators, in addition to a deeper quantitative and qualitative look into our approach to designing and prototyping a complete virtual-based haptic EES training platform.
△ Less
Submitted 11 March, 2023;
originally announced March 2023.
-
A Data-Driven Model with Hysteresis Compensation for I2RIS Robot
Authors:
Mojtaba Esfandiari,
Yanlin Zhou,
Shervin Dehghani,
Muhammad Hadi,
Adnan Munawar,
Henry Phalen,
Peter Gehlbach,
Russell H. Taylor,
Iulian Iordachita
Abstract:
Retinal microsurgery is a high-precision surgery performed on an exceedingly delicate tissue. It now requires extensively trained and highly skilled surgeons. Given the restricted range of instrument motion in the confined intraocular space, and also potentially restricting instrument contact with the sclera, snake-like robots may prove to be a promising technology to provide surgeons with greater…
▽ More
Retinal microsurgery is a high-precision surgery performed on an exceedingly delicate tissue. It now requires extensively trained and highly skilled surgeons. Given the restricted range of instrument motion in the confined intraocular space, and also potentially restricting instrument contact with the sclera, snake-like robots may prove to be a promising technology to provide surgeons with greater flexibility, dexterity, space access, and positioning accuracy during retinal procedures requiring high precision and advantageous tooltip approach angles, such as retinal vein cannulation and epiretinal membrane peeling. Kinematics modeling of these robots is an essential step toward accurate position control, however, as opposed to conventional manipulators, modeling of these robots does not follow a straightforward method due to their complex mechanical structure and actuation mechanisms. Especially, in wire-driven snake-like robots, the hysteresis problem due to the wire tension condition can have a significant impact on the positioning accuracy of these robots. In this paper, we proposed an experimental kinematics model with a hysteresis compensation algorithm using the probabilistic Gaussian mixture models (GMM) Gaussian mixture regression (GMR) approach. Experimental results on the two-degree-of-freedom (DOF) integrated robotic intraocular snake (I2RIS) show that the proposed model provides 0.4 deg accuracy, which is an overall 60% and 70% of improvement for yaw and pitch degrees of freedom, respectively, compared to a previous model of this robot.
△ Less
Submitted 10 March, 2023;
originally announced March 2023.
-
Design and Fabrication of a Fiber Bragg Grating Shape Sensor for Shape Reconstruction of a Continuum Manipulator
Authors:
Golchehr Amirkhani,
Anna Goodridge,
Mojtaba Esfandiari,
Henry Phalen,
Justin H. Ma,
Iulian Iordachita,
Mehran Armand
Abstract:
Continuum dexterous manipulators (CDMs) are suitable for performing tasks in a constrained environment due to their high dexterity and maneuverability. Despite the inherent advantages of CDMs in minimally invasive surgery, real-time control of CDMs' shape during non-constant curvature bending is still challenging. This study presents a novel approach for the design and fabrication of a large defle…
▽ More
Continuum dexterous manipulators (CDMs) are suitable for performing tasks in a constrained environment due to their high dexterity and maneuverability. Despite the inherent advantages of CDMs in minimally invasive surgery, real-time control of CDMs' shape during non-constant curvature bending is still challenging. This study presents a novel approach for the design and fabrication of a large deflection fiber Bragg grating (FBG) shape sensor embedded within the lumens inside the walls of a CDM with a large instrument channel. The shape sensor consisted of two fibers, each with three FBG nodes. A shape-sensing model was introduced to reconstruct the centerline of the CDM based on FBG wavelengths. Different experiments, including shape sensor tests and CDM shape reconstruction tests, were conducted to assess the overall accuracy of the shape sensing. The FBG sensor evaluation results revealed the linear curvature-wavelength relationship with the large curvature detection of 0.045 mm at a 90 degrees bending angle and a sensitivity of up to 5.50 nm/mm in each bending direction. The CDM's shape reconstruction experiments in a free environment demonstrated the shape tracking accuracy of 0.216+-0.126 mm for positive/negative deflections. Also, the CDM shape reconstruction error for three cases of bending with obstacles were observed to be 0.436+-0.370 mm for the proximal case, 0.485+-0.418 mm for the middle case, and 0.312+-0.261 mm for the distal case. This study indicates the adequate performance of the FBG sensor and the effectiveness of the model for tracking the shape of the large-deflection CDM with nonconstant-curvature bending for minimally-invasive orthopaedic applications.
△ Less
Submitted 6 March, 2023;
originally announced March 2023.
-
Non-Iterative Subspace-Based DOA Estimation in the Presence of Nonuniform Noise
Authors:
M. Esfandiari,
S. A. Vorobyov,
S. Aliban,
M. Karimi
Abstract:
The uniform white noise assumption is one of the basic assumptions in most of the existing directional-of-arrival (DOA) estimation methods. In many applications, however, the non-uniform white noise model is more adequate. Then the noise variances at different sensors have to be also estimated as nuisance parameters while estimating DOAs. In this letter, different from the existing iterative metho…
▽ More
The uniform white noise assumption is one of the basic assumptions in most of the existing directional-of-arrival (DOA) estimation methods. In many applications, however, the non-uniform white noise model is more adequate. Then the noise variances at different sensors have to be also estimated as nuisance parameters while estimating DOAs. In this letter, different from the existing iterative methods that address the problem of non-uniform noise, a non-iterative two-phase subspace-based DOA estimation method is proposed. The first phase of the method is based on estimating the noise subspace via eigendecomposition (ED) of some properly designed matrix and it avoids estimating the noise covariance matrix. In the second phase, the results achieved in the first phase are used to estimate the noise covariance matrix, followed by estimating the noise subspace via generalized ED. Since the proposed method estimates DOAs in a non-iterative manner, it is computationally more efficient and has no convergence issues as compared to the existing methods. Simulation results demonstrate better performance of the proposed method as compared to other existing state-of-the-art methods.
△ Less
Submitted 27 March, 2019;
originally announced March 2019.
-
Eliciting Worker Preference for Task Completion
Authors:
Mohammadreza Esfandiari,
Senjuti Basu Roy,
Sihem Amer-Yahia
Abstract:
Current crowdsourcing platforms provide little support for worker feedback. Workers are sometimes invited to post free text describing their experience and preferences in completing tasks. They can also use forums such as Turker Nation1 to exchange preferences on tasks and requesters. In fact, crowdsourcing platforms rely heavily on observing workers and inferring their preferences implicitly. In…
▽ More
Current crowdsourcing platforms provide little support for worker feedback. Workers are sometimes invited to post free text describing their experience and preferences in completing tasks. They can also use forums such as Turker Nation1 to exchange preferences on tasks and requesters. In fact, crowdsourcing platforms rely heavily on observing workers and inferring their preferences implicitly. In this work, we believe that asking workers to indicate their preferences explicitly improve their experience in task completion and hence, the quality of their contributions. Explicit elicitation can indeed help to build more accurate worker models for task completion that captures the evolving nature of worker preferences. We design a worker model whose accuracy is improved iteratively by requesting preferences for task factors such as required skills, task payment, and task relevance. We propose a generic framework, develop efficient solutions in realistic scenarios, and run extensive experiments that show the benefit of explicit preference elicitation over implicit ones with statistical significance.
△ Less
Submitted 9 January, 2018;
originally announced January 2018.