-
Using CamiTK for rapid prototyping of interactive Computer Assisted Medical Intervention applications
Authors:
Emmanuel Promayon,
Celine Fouard,
Mathieu Bailet,
Aurelien Deram,
Gaelle Fiard,
Nikolai Hungr,
Vincent Luboz,
Yohan Payan,
Johan Sarrazin,
Nicolas Saubat,
Sonia Yuki Selmi,
Sandrine Voros,
Philippe Cinquin,
Jocelyne Troccaz
Abstract:
Computer Assisted Medical Intervention (CAMI hereafter) is a complex multi-disciplinary field. CAMI research requires the collaboration of experts in several fields as diverse as medicine, computer science, mathematics, instrumentation, signal processing, mechanics, modeling, automatics, optics, etc.
Computer Assisted Medical Intervention (CAMI hereafter) is a complex multi-disciplinary field. CAMI research requires the collaboration of experts in several fields as diverse as medicine, computer science, mathematics, instrumentation, signal processing, mechanics, modeling, automatics, optics, etc.
△ Less
Submitted 21 October, 2013;
originally announced October 2013.
-
First Clinical Experience in Urologic Surgery with a Novel Robotic Lightweight Laparoscope Holder
Authors:
Jean-Alexandre Long,
Jacques Tostain,
Cecilia Lanchon,
Sandrine Voros,
Maud Medici,
Jean-Luc Descotes,
Jocelyne Troccaz,
Philippe Cinquin,
Jean-Jacques Rambeaud,
Alexandre Moreau-Gaudry
Abstract:
Purpose: To report the feasibility and the safety of a surgeon-controlled robotic endoscope holder in laparoscopic surgery. Materials and methods: From March 2010 to September 2010, 20 patients were enrolled prospectively to undergo a laparoscopic surgery using an innovative robotic endoscope holder. Two surgeons performed 6 adrenalectomies, 4 sacrocolpopexies, 5 pyeloplasties, 4 radical prostatec…
▽ More
Purpose: To report the feasibility and the safety of a surgeon-controlled robotic endoscope holder in laparoscopic surgery. Materials and methods: From March 2010 to September 2010, 20 patients were enrolled prospectively to undergo a laparoscopic surgery using an innovative robotic endoscope holder. Two surgeons performed 6 adrenalectomies, 4 sacrocolpopexies, 5 pyeloplasties, 4 radical prostatectomies and 1 radical nephrectomy. Demographic data, overall set-up time, operative time, number of assistants needed were reviewed. Surgeon's satisfaction regarding the ergonomics was assessed using a ten point scale. Postoperative clinical outcomes were reviewed at day 1 and 1 month postoperatively. Results: The per-protocol analysis was performed on 17 patients for whom the robot was effectively used for surgery. Median age was 63 years, 10 patients were female (59%). Median BMI was 26.8. Surgical procedures were completed with the robot in 12 cases (71 %). Median number of surgical assistant was 0. Overall set-up time with the robot was 19 min, operative time was 130 min) during which the robot was used 71% of the time. Mean hospital stay was 6.94 days $\pm$ 2.3. Median score regarding the easiness of use was 7. Median pain level was 1.5/10 at day 1 and 0 at 1 month postoperatively. Open conversion was needed in 1 case (6 %) and 4 minor complications occurred in 2 patients (12%). Conclusion: This use of this novel robotic laparoscope holder is safe, feasible and it provides a good comfort to the surgeon.
△ Less
Submitted 31 August, 2012;
originally announced August 2012.
-
TER: A Robot for Remote Ultrasonic Examination: Experimental Evaluations
Authors:
Jean-Jacques Banihachemi,
Eric Boidard,
Jean-Luc Bosson,
Luc Bressollette,
Ivan Bricault,
Philippe Cinquin,
Gilbert Ferretti,
Maud Marchal,
Thomas Martinelli,
Alexandre Moreau-Gaudry,
Franck Pelissier,
Christian Roux,
Dominique Saragaglia,
Pierre Thorel,
Jocelyne Troccaz,
Adriana Vilchis
Abstract:
This chapter:
o Motivates the clinical use of robotic tele-echography
o Introduces the TER system
o Describes technical and clinical evaluations performed with TER
This chapter:
o Motivates the clinical use of robotic tele-echography
o Introduces the TER system
o Describes technical and clinical evaluations performed with TER
△ Less
Submitted 28 January, 2008;
originally announced January 2008.
-
Medical image computing and computer-aided medical interventions applied to soft tissues. Work in progress in urology
Authors:
Jocelyne Troccaz,
Michael Baumann,
Peter Berkelman,
Philippe Cinquin,
Vincent Daanen,
Antoine Leroy,
Maud Marchal,
Yohan Payan,
Emmanuel Promayon,
Sandrine Voros,
Stéphane Bart,
Michel Bolla,
Emmanuel Chartier-Kastler,
Jean-Luc Descotes,
Andrée Dusserre,
Jean-Yves Giraud,
Jean-Alexandre Long,
Ronan Moalic,
Pierre Mozer
Abstract:
Until recently, Computer-Aided Medical Interventions (CAMI) and Medical Robotics have focused on rigid and non deformable anatomical structures. Nowadays, special attention is paid to soft tissues, raising complex issues due to their mobility and deformation. Mini-invasive digestive surgery was probably one of the first fields where soft tissues were handled through the development of simulators…
▽ More
Until recently, Computer-Aided Medical Interventions (CAMI) and Medical Robotics have focused on rigid and non deformable anatomical structures. Nowadays, special attention is paid to soft tissues, raising complex issues due to their mobility and deformation. Mini-invasive digestive surgery was probably one of the first fields where soft tissues were handled through the development of simulators, tracking of anatomical structures and specific assistance robots. However, other clinical domains, for instance urology, are concerned. Indeed, laparoscopic surgery, new tumour destruction techniques (e.g. HIFU, radiofrequency, or cryoablation), increasingly early detection of cancer, and use of interventional and diagnostic imaging modalities, recently opened new challenges to the urologist and scientists involved in CAMI. This resulted in the last five years in a very significant increase of research and developments of computer-aided urology systems. In this paper, we propose a description of the main problems related to computer-aided diagnostic and therapy of soft tissues and give a survey of the different types of assistance offered to the urologist: robotization, image fusion, surgical navigation. Both research projects and operational industrial systems are discussed.
△ Less
Submitted 13 December, 2007;
originally announced December 2007.
-
Development of miniaturized light endoscope-holder robot for laparoscopic surgery
Authors:
Jean-Alexandre Long,
Philippe Cinquin,
Jocelyne Troccaz,
Sandrine Voros,
Jean-Luc Descotes,
Peter Berkelman,
Christian Letoublon,
Jean-Jacques Rambeaud
Abstract:
PURPOSE: We have conducted experiments with an innovatively designed robot endoscope holder for laparoscopic surgery that is small and low cost. MATERIALS AND METHODS: A compact light endoscope robot (LER) that is placed on the patient's skin and can be used with the patient in the lateral or dorsal supine position was tested on cadavers and laboratory pigs in order to allow successive modificat…
▽ More
PURPOSE: We have conducted experiments with an innovatively designed robot endoscope holder for laparoscopic surgery that is small and low cost. MATERIALS AND METHODS: A compact light endoscope robot (LER) that is placed on the patient's skin and can be used with the patient in the lateral or dorsal supine position was tested on cadavers and laboratory pigs in order to allow successive modifications. The current control system is based on voice recognition. The range of vision is 360 degrees with an angle of 160 degrees . Twenty-three procedures were performed. RESULTS: The tests made it possible to advance the prototype on a variety of aspects, including reliability, steadiness, ergonomics, and dimensions. The ease of installation of the robot, which takes only 5 minutes, and the easy handling made it possible for 21 of the 23 procedures to be performed without an assistant. CONCLUSION: The LER is a camera holder guided by the surgeon's voice that can eliminate the need for an assistant during laparoscopic surgery. The ease of installation and manufacture should make it an effective and inexpensive system for use on patients in the lateral and dorsal supine positions. Randomized clinical trials will soon validate a new version of this robot prior to marketing.
△ Less
Submitted 30 November, 2007;
originally announced November 2007.
-
Robot-based tele-echography: clinical evaluation of the TER system in abdominal aortic exploration
Authors:
Thomas Martinelli,
Jean-Luc Bosson,
Luc Bressollette,
Franck Pelissier,
Eric Boidard,
Jocelyne Troccaz,
Philippe Cinquin
Abstract:
OBJECTIVE: The TER system is a robot-based tele-echography system allowing remote ultrasound examination. The specialist moves a mock-up of the ultrasound probe at the master site, and the robot reproduces the movements of the real probe, which sends back ultrasound images and force feedback. This tool could be used to perform ultrasound examinations in small health care centers or from isolated…
▽ More
OBJECTIVE: The TER system is a robot-based tele-echography system allowing remote ultrasound examination. The specialist moves a mock-up of the ultrasound probe at the master site, and the robot reproduces the movements of the real probe, which sends back ultrasound images and force feedback. This tool could be used to perform ultrasound examinations in small health care centers or from isolated sites. The objective of this study was to prove, under real conditions, the feasibility and reliability of the TER system in detecting abdominal aortic and iliac aneurysms. METHODS: Fifty-eight patients were included in 2 centers in Brest and Grenoble, France. The remote examination was compared with the reference standard, the bedside examination, for aorta and iliac artery diameter measurement, detection and description of aneurysms, detection of atheromatosis, the duration of the examination, and acceptability. RESULTS: All aneurysms (8) were detected by both techniques as intramural thrombosis and extension to the iliac arteries. The interobserver correlation coefficient was 0.982 (P < .0001) for aortic diameters. The rate of concordance between 2 operators in evaluating atheromatosis was 84% +/- 11% (95% confidence interval). CONCLUSIONS: Our study on 58 patients suggests that the TER system could be a reliable, acceptable, and effective robot-based system for performing remote abdominal aortic ultrasound examinations. Research is continuing to improve the equipment for general abdominal use.
△ Less
Submitted 28 November, 2007;
originally announced November 2007.