-
Impact of Electrode Position on Forearm Orientation Invariant Hand Gesture Recognition
Authors:
Md. Johirul Islam,
Umme Rumman,
Arifa Ferdousi,
Md. Sarwar Pervez,
Iffat Ara,
Shamim Ahmad,
Fahmida Haque,
Sawal Hamid,
Md. Ali,
Kh Shahriya Zaman,
Mamun Bin Ibne Reaz,
Mustafa Habib Chowdhury,
Md. Rezaul Islam
Abstract:
Objective: Variation of forearm orientation is one of the crucial factors that drastically degrades the forearm orientation invariant hand gesture recognition performance or the degree of freedom and limits the successful commercialization of myoelectric prosthetic hand or electromyogram (EMG) signal-based human-computer interfacing devices. This study investigates the impact of surface EMG electr…
▽ More
Objective: Variation of forearm orientation is one of the crucial factors that drastically degrades the forearm orientation invariant hand gesture recognition performance or the degree of freedom and limits the successful commercialization of myoelectric prosthetic hand or electromyogram (EMG) signal-based human-computer interfacing devices. This study investigates the impact of surface EMG electrode positions (elbow and forearm) on forearm orientation invariant hand gesture recognition. Methods: The study has been performed over 19 intact limbed subjects, considering 12 daily living hand gestures. The quality of the EMG signal is confirmed in terms of three indices. Then, the recognition performance is evaluated and validated by considering three training strategies, six feature extraction methods, and three classifiers. Results: The forearm electrode position provides comparable to or better EMG signal quality considering three indices. In this research, the forearm electrode position achieves up to 5.35% improved forearm orientation invariant hand gesture recognition performance compared to the elbow electrode position. The obtained performance is validated by considering six feature extraction methods, three classifiers, and real-time experiments. In addition, the forearm electrode position shows its robustness with the existence of recent works, considering recognition performance, investigated gestures, the number of channels, the dimensionality of feature space, and the number of subjects. Conclusion: The forearm electrode position can be the best choice for getting improved forearm orientation invariant hand gesture recognition performance. Significance: The performance of myoelectric prosthesis and human-computer interfacing devices can be improved with this optimized electrode position.
△ Less
Submitted 16 September, 2024;
originally announced October 2024.
-
Design of Novel 3T Ternary DRAM with Single Word-Line using CNTFET
Authors:
Zarin Tasnim Sandhie,
Farid Uddin Ahmed,
Masud H. Chowdhury
Abstract:
Ternary logic system is the most promising and pursued alternate to the prevailing binary logic systems due to the energy efficiency of circuits following reduced circuit complexity and chip area. In this paper, we have proposed a ternary 3-Transistor Dynamic Random-Access Memory (3T-DRAM) cell using a single word-line for both read and write operation. For simulation of the circuit, we have used…
▽ More
Ternary logic system is the most promising and pursued alternate to the prevailing binary logic systems due to the energy efficiency of circuits following reduced circuit complexity and chip area. In this paper, we have proposed a ternary 3-Transistor Dynamic Random-Access Memory (3T-DRAM) cell using a single word-line for both read and write operation. For simulation of the circuit, we have used Carbon-Nano-Tube Field Effect Transistor (CNTFET). Here, we have analyzed the operation of the circuit considering different process variations and showed the results for write delay, read sensing time, and consumed current. Along with the basic DRAM design, we have proposed a ternary sense circuitry for the proper read operation of the proposed DRAM. The simulation and analysis are executed using the H-SPICE tool with Stanford University CNTFET model.
△ Less
Submitted 20 August, 2021;
originally announced August 2021.
-
A Novel Non-Invasive Estimation of Respiration Rate from Photoplethysmograph Signal Using Machine Learning Model
Authors:
Md Nazmul Islam Shuzan,
Moajjem Hossain Chowdhury,
Muhammad E. H. Chowdhury,
M. Monir Uddin,
Amith Khandakar,
Zaid B. Mahbub,
Naveed Nawaz
Abstract:
Respiratory ailments such as asthma, chronic obstructive pulmonary disease (COPD), pneumonia, and lung cancer are life-threatening. Respiration rate (RR) is a vital indicator of the wellness of a patient. Continuous monitoring of RR can provide early indication and thereby save lives. However, a real-time continuous RR monitoring facility is only available at the intensive care unit (ICU) due to t…
▽ More
Respiratory ailments such as asthma, chronic obstructive pulmonary disease (COPD), pneumonia, and lung cancer are life-threatening. Respiration rate (RR) is a vital indicator of the wellness of a patient. Continuous monitoring of RR can provide early indication and thereby save lives. However, a real-time continuous RR monitoring facility is only available at the intensive care unit (ICU) due to the size and cost of the equipment. Recent researches have proposed Photoplethysmogram (PPG) and/ Electrocardiogram (ECG) signals for RR estimation however, the usage of ECG is limited due to the unavailability of it in wearable devices. Due to the advent of wearable smartwatches with built-in PPG sensors, it is now being considered for continuous monitoring of RR. This paper describes a novel approach to RR estimation using machine learning (ML) models with the PPG signal features. Feature selection algorithms were used to reduce computational complexity and the chance of overfitting. The best ML model and the best feature selection algorithm combination was fine-tuned to optimize its performance using hyperparameter optimization. Gaussian Process Regression (GPR) with fitrgp feature selection algorithm outperformed all other combinations and exhibits a root mean squared error (RMSE), mean absolute error (MAE), and two-standard deviation (2SD) of 2.57, 1.91, and 5.13 breaths per minute, respectively. This ML model based RR estimation can be embedded in wearable devices for real-time continuous monitoring of the patient.
△ Less
Submitted 18 February, 2021;
originally announced February 2021.
-
Estimating Blood Pressure from Photoplethysmogram Signal and Demographic Features using Machine Learning Techniques
Authors:
Moajjem Hossain Chowdhury,
Md Nazmul Islam Shuzan,
Muhammad E. H. Chowdhury,
Zaid B Mahbub,
M. Monir Uddin,
Amith Khandakar,
Mamun Bin Ibne Reaz
Abstract:
Hypertension is a potentially unsafe health ailment, which can be indicated directly from the Blood pressure (BP). Hypertension always leads to other health complications. Continuous monitoring of BP is very important; however, cuff-based BP measurements are discrete and uncomfortable to the user. To address this need, a cuff-less, continuous and a non-invasive BP measurement system is proposed us…
▽ More
Hypertension is a potentially unsafe health ailment, which can be indicated directly from the Blood pressure (BP). Hypertension always leads to other health complications. Continuous monitoring of BP is very important; however, cuff-based BP measurements are discrete and uncomfortable to the user. To address this need, a cuff-less, continuous and a non-invasive BP measurement system is proposed using Photoplethysmogram (PPG) signal and demographic features using machine learning (ML) algorithms. PPG signals were acquired from 219 subjects, which undergo pre-processing and feature extraction steps. Time, frequency and time-frequency domain features were extracted from the PPG and their derivative signals. Feature selection techniques were used to reduce the computational complexity and to decrease the chance of over-fitting the ML algorithms. The features were then used to train and evaluate ML algorithms. The best regression models were selected for Systolic BP (SBP) and Diastolic BP (DBP) estimation individually. Gaussian Process Regression (GPR) along with ReliefF feature selection algorithm outperforms other algorithms in estimating SBP and DBP with a root-mean-square error (RMSE) of 6.74 and 3.59 respectively. This ML model can be implemented in hardware systems to continuously monitor BP and avoid any critical health conditions due to sudden changes.
△ Less
Submitted 7 May, 2020;
originally announced May 2020.
-
Improved Model for Wire-Length Estimation in Stochastic Wiring Distribution
Authors:
Mohamed S. Hefeida,
Masud H. Chowdhury
Abstract:
This paper presents a pair of improved stochastic wiring distribution model for better estimation of on-chip wire lengths. The proposed models provide 28 - 50% reduction in error when estimating the average on-chip wire length compared to the estimation using the existing models. The impact of Rent's exponent on the average wire length estimation is also investigated to demonstrate limitations of…
▽ More
This paper presents a pair of improved stochastic wiring distribution model for better estimation of on-chip wire lengths. The proposed models provide 28 - 50% reduction in error when estimating the average on-chip wire length compared to the estimation using the existing models. The impact of Rent's exponent on the average wire length estimation is also investigated to demonstrate limitations of the approximations used in some of the current models. To improve the approximations of the model a new threshold for Rent's constant is recommended. Simulation results demonstrate that proposed models with the new threshold reduce the error of estimation by 38 to 75 percent compared to the previous works.
△ Less
Submitted 19 February, 2015;
originally announced February 2015.