-
Rheological design of thickened alcohol-based hand rubs
Authors:
Andreia F Silva,
Tiffany A Wood,
Daniel J M Hodgson,
John R Royer,
Job H J Thijssen,
Alex Lips,
Wilson C K Poon
Abstract:
The handleability and sensory perception of hand sanitisers by consumers affect the hygiene outcome. Spillage may result in under-dosing and poor sensory properties can lead to under-utilisation. We first propose four principles (low run off, spreadability, smoothness and non-stickiness) for designing the rheology of thickened alcohol-based hand rubs with acceptable handleability and hand feel. We…
▽ More
The handleability and sensory perception of hand sanitisers by consumers affect the hygiene outcome. Spillage may result in under-dosing and poor sensory properties can lead to under-utilisation. We first propose four principles (low run off, spreadability, smoothness and non-stickiness) for designing the rheology of thickened alcohol-based hand rubs with acceptable handleability and hand feel. We then evaluate a commercial hand gel and a variety of simplified formulations thickened with microgels (Carbopol 974P, Carbopol Ultrez 20 and Sepimax Zen), or linear polymers (Jaguar HP 120 COS), and evaluate them against these design criteria. All four additives provide acceptable spreadability by shear thinning to $η\approx 10^{-1} Pa \, s$ at $\dotγ\sim 10^3 s^{-1}$. Either the finite yield stress conferred by the microgels ($σ_y \gtrsim 10 Pa$) or the increase in low-shear viscosity provided by the linear polymer ($η\gtrsim 1 Pa \, s$ at $\dotγ\lesssim 0.1 s^{-1}$) give rise to acceptably low run-off. However, the formulation using the linear polymer shows a filament breakage time of $τ_{\rm b} \approx 1 s$ in capillary rheology, which may result in stickiness and therefore a less than optimal hand feel.
△ Less
Submitted 5 May, 2022; v1 submitted 24 January, 2022;
originally announced January 2022.
-
Dynamic Response of Glassy Dispersions in a Nematic Liquid Crystal
Authors:
Navneeta Katyan,
Tiffany Annette Wood
Abstract:
We present the first systematic measurements of the dynamic response of a glassy soft-solid formed on dispersing colloids in a thermotropic nematic liquid crystal. Through applying a simple theoretical model, we reveal that the nematic elasticity dominates at low frequencies (longest timescales) and prevents flow. The Ericksen number $E_R$, determines a critical frequency $ω_c$, above which the vi…
▽ More
We present the first systematic measurements of the dynamic response of a glassy soft-solid formed on dispersing colloids in a thermotropic nematic liquid crystal. Through applying a simple theoretical model, we reveal that the nematic elasticity dominates at low frequencies (longest timescales) and prevents flow. The Ericksen number $E_R$, determines a critical frequency $ω_c$, above which the viscous component $G'' \propto ω^{1/2}$. We find that the value of tan$δ$ is independent of the colloidal volume fraction ($φ$), and is determined by the ratio of lengthscales associated with the defect-line density and the size of colloid-free nematic regions trapped within the composite.
△ Less
Submitted 23 December, 2019;
originally announced December 2019.
-
Direct measurement of the effective charge in nonpolar suspensions by optical tracking of single particles
Authors:
G. Seth Roberts,
Tiffany A. Wood,
William J. Frith,
Paul Bartlett
Abstract:
We demonstrate a novel technique for the measurement of the charge carried by a colloidal particle. The technique uses the phenomenon of the resonance of a particle held in an optical tweezers trap and driven by a sinusoidal electric field. The trapped particle forms a strongly damped harmonic oscillator whose fluctuations are a function of $γ$, the ratio of the root-mean square average of the e…
▽ More
We demonstrate a novel technique for the measurement of the charge carried by a colloidal particle. The technique uses the phenomenon of the resonance of a particle held in an optical tweezers trap and driven by a sinusoidal electric field. The trapped particle forms a strongly damped harmonic oscillator whose fluctuations are a function of $γ$, the ratio of the root-mean square average of the electric and thermal forces on the particle. At low applied fields, where $γ\ll 1$, the particle is confined to the optical axis while at high fields ($γ\gg 1$) the probability distribution of the particle is double-peaked. The periodically-modulated thermal fluctuations are measured with nanometer sensitivity using an interferometric position detector. Charges, as low as a few elementary charges, can be measured with an uncertainty of about 0.25 $e$. This is significantly better than previous techniques and opens up new possibilities for the study of nonpolar suspensions.
△ Less
Submitted 26 January, 2007;
originally announced January 2007.
-
Computer Algebra calculation of XRMS polarisation dependence in the non spherical case
Authors:
Thomas A. Wood,
Alessandro Mirone
Abstract:
Simple analytical formulae, directly relating the experimental geometry and sample orientation to the measured R(M)XS scattered intensity are very useful to design experiments and analyse data. Such formulae can be obtained by the contraction of an expression containing the polarisations and crystal field tensors, and where the magnetisation vector acts as a rotation derivative\cite{mirone}. The…
▽ More
Simple analytical formulae, directly relating the experimental geometry and sample orientation to the measured R(M)XS scattered intensity are very useful to design experiments and analyse data. Such formulae can be obtained by the contraction of an expression containing the polarisations and crystal field tensors, and where the magnetisation vector acts as a rotation derivative\cite{mirone}. The result of a contraction contains a scalar product of (rotated) polarisation vectors and the crystal field axis. The contraction rules give rise to combinatorial algorithms which can be efficiently treated by computers. In this work we provide and discuss a concise Mathematica code along with a few example applications to non-centrosymmetric magnetic systems.
△ Less
Submitted 13 November, 2006;
originally announced November 2006.