Electroluminescence from a diamond device with ion-beam-micromachined buried graphitic electrodes
Authors:
J. Forneris,
A. Battiato,
D. Gatto Monticone,
F. Picollo,
G. Amato,
L. Boarino,
G. Brida,
I. P. Degiovanni,
E. Enrico,
M. Genovese,
E. Moreva,
P. Traina,
C. Verona,
G. Verona-Rinati,
P. Olivero
Abstract:
Focused MeV ion microbeams are suitable tools for the direct writing of conductive graphitic channels buried in an insulating diamond bulk, as demonstrated in previous works with the fabrication of multi-electrode ionizing radiation detectors and cellular biosensors. In this work we investigate the suitability of the fabrication method for the electrical excitation of colour centres in diamond. Di…
▽ More
Focused MeV ion microbeams are suitable tools for the direct writing of conductive graphitic channels buried in an insulating diamond bulk, as demonstrated in previous works with the fabrication of multi-electrode ionizing radiation detectors and cellular biosensors. In this work we investigate the suitability of the fabrication method for the electrical excitation of colour centres in diamond. Differently from photoluminescence, electroluminescence requires an electrical current flowing through the diamond sub-gap states for the excitation of the colour centres. With this purpose, buried graphitic electrodes with a spacing of 10 micrometers were fabricated in the bulk of a detector-grade CVD single-crystal diamond sample using a scanning 1.8 MeV He micro-beam. The current flowing in the gap region between the electrodes upon the application of a 250 V bias voltage was exploited as the excitation pump for the electroluminescence of different types of colour centres localized in the above-mentioned gap. The bright light emission was spatially mapped using a confocal optical microscopy setup. The spectral analysis of electroluminescence revealed the emission from neutrally-charged nitrogen-vacancy centres ($NV^0$, $λ_{ZPL}$ = 575 nm), as well as from cluster crystal dislocations (A-band, λ = 400-500 nm). Moreover, an electroluminescence signal with appealing spectral features (sharp emission at room temperature, low phonon sidebands) from He-related defects was detected ($λ_{ZPL}$ = 536.3 nm, $λ_{ZPL}$ = 560.5 nm); a low and broad peak around λ = 740 nm was also observed and tentatively ascribed to Si-V or GR1 centres. These results pose interesting future perspectives for the fabrication of electrically-stimulated single-photon emitters in diamond for applications in quantum optics and quantum cryptography.
△ Less
Submitted 29 July, 2014;
originally announced July 2014.
Measurement and modelling of anomalous polarity pulses in a multi-electrode diamond detector
Authors:
J. Forneris,
V. Grilj,
M. Jaksic,
P. Olivero,
F. Picollo,
N. Skukan,
C. Verona,
G. Verona-Rinati,
E. Vittone
Abstract:
In multi-electrode detectors, the motion of excess carriers generated by ionizing radiation induces charge pulses at the electrodes, whose intensities and polarities depend on the geometrical, electrostatic and carriers transport properties of the device. The resulting charge sharing effects may lead to bipolar currents, pulse height defects and anomalous polarity signals affecting the response of…
▽ More
In multi-electrode detectors, the motion of excess carriers generated by ionizing radiation induces charge pulses at the electrodes, whose intensities and polarities depend on the geometrical, electrostatic and carriers transport properties of the device. The resulting charge sharing effects may lead to bipolar currents, pulse height defects and anomalous polarity signals affecting the response of the device to ionizing radiation. This latter effect has recently attracted attention in commonly used detector materials, but different interpretations have been suggested, depending on the material, the geometry of the device and the nature of the ionizing radiation. In this letter, we report on the investigation in the formation of anomalous polarity pulses in a multi-electrode diamond detector with buried graphitic electrodes. In particular, we propose a purely electrostatic model based on the Shockley-Ramo-Gunn theory, providing a satisfactory description of anomalous pulses observed in charge collection efficiency maps measured by means of Ion Beam Induced Charge (IBIC) microscopy, and suitable for a general application in multi-electrode devices and detectors.
△ Less
Submitted 17 December, 2013;
originally announced December 2013.