-
Load impedance of immersed layers on the quartz crystal microbalance: a comparison with colloidal suspensions of spheres
Authors:
M. Meléndez,
A. Vázquez-Quesada,
R. Delgado-Buscalioni
Abstract:
The analytical theories derived here for the acoustic load impedance measured by a quartz crystal microbalance (QCM), due to the presence of layers of different types (rigid, elastic and viscous) immersed in a fluid, display generic properties, such as "vanishing mass" and positive frequency shifts, which have been observed in QCM experiments with soft-matter systems. These phenomena seem to contr…
▽ More
The analytical theories derived here for the acoustic load impedance measured by a quartz crystal microbalance (QCM), due to the presence of layers of different types (rigid, elastic and viscous) immersed in a fluid, display generic properties, such as "vanishing mass" and positive frequency shifts, which have been observed in QCM experiments with soft-matter systems. These phenomena seem to contradict the well-known Sauerbrey relation at the heart of many QCM measurements, but here we show that they arise as a natural consequence of hydrodynamics. We compare our one-dimensional immersed plate theory with three-dimensional simulations of rigid and flexible sub-micron-sized suspended spheres, and with experimental results for adsorbed micron-sized colloids which yield a "negative acoustic mass". The parallel behaviour unveiled indicates that the QCM response is highly sensitive to hydrodynamics, even for adsorbed colloids. Our conclusions call for a revision of existing theories based on adhesion forces and elastic stiffness at contact, which should in most cases include hydrodynamics.
△ Less
Submitted 7 May, 2020;
originally announced May 2020.
-
Hydrodynamics of quartz crystal microbalance experiments with liposome-DNA complexes
Authors:
Adolfo Vazquez-Quesada,
Marc Melendez Schofield,
Achilleas Tsortos,
Pablo Mateos-Gil,
Electra Gizeli,
Rafael Delgado Buscalioni
Abstract:
The quartz crystal microbalance (QCM) is widely used to study surface adsorbed molecules, often of biological significance. However, the relation between raw acoustic response (frequency shift $Δf$ and dissipation factor $ΔD$) and mechanical properties of the macromolecules still needs to be deciphered, particularly in the case of suspended discrete particles. We study the QCM response of suspende…
▽ More
The quartz crystal microbalance (QCM) is widely used to study surface adsorbed molecules, often of biological significance. However, the relation between raw acoustic response (frequency shift $Δf$ and dissipation factor $ΔD$) and mechanical properties of the macromolecules still needs to be deciphered, particularly in the case of suspended discrete particles. We study the QCM response of suspended liposomes tethered to the resonator wall by double stranded DNA, with the other end attached to surface-adsorbed neutravidin through a biotin linker. Liposome radius and dsDNA contour length are comparable to the wave penetration depth ($δ\sim 100\ \mathrm{nm}$). Simulations, based on the immersed boundary method and an elastic network model for the liposome-DNA complex, are in good agreement with experimental results for POPC liposomes. We find that the added stress at the resonator surface, i.e. the impedance Z sensed by QCM, is dominated by the flow-induced liposome surface-stress, which propagates towards the resonator by viscous forces. QCM signals are extremely sensitive to the liposome's height distribution P(y) which depends on the actual number and mechanical properties of the tethers, in addition to the usual local attractive/repulsive chemical forces. Our approach helps in deciphering the role of hydrodynamics in acoustic sensing and revealing the role of parameters hitherto largely unexplored. A practical consequence would be the design of improved biosensors and detection schemes.
△ Less
Submitted 21 February, 2020;
originally announced February 2020.
-
A multiblob approach to colloidal hydrodynamics with inherent lubrication
Authors:
Adolfo Vázquez-Quesada,
Florencio Balboa Usabiaga,
Rafael Delgado-Buscalioni
Abstract:
This work presents an intermediate resolution model of the hydrodynamics of colloidal particles based on a mixed Eulerian-Lagrangian formulation. The particle is constructed with a small set of overlapping Peskin's Immersed Boundary kernels (blobs) which are held together by springs to build up a particle impenetrable core. Here, we used 12 blobs placed in the vertexes of an icosahedron with an ex…
▽ More
This work presents an intermediate resolution model of the hydrodynamics of colloidal particles based on a mixed Eulerian-Lagrangian formulation. The particle is constructed with a small set of overlapping Peskin's Immersed Boundary kernels (blobs) which are held together by springs to build up a particle impenetrable core. Here, we used 12 blobs placed in the vertexes of an icosahedron with an extra one in its center. Although the particle surface is not explicitly resolved, we show that the short-distance hydrodynamic responses (flow profiles, translational and rotational mobilities, lubrication, etc) agree with spherical colloids and provide consistent effective radii. A remarkable property of the present multiblob model is that it naturally presents a "divergent" lubrication force at finite inter-particle distance. This permits to resolve the large viscosity increase at dense colloidal volume fractions. The intermediate resolution model is able to recover highly non-trivial (many-body) hydrodynamics using small particles whose radii are similar to the grid size $h$ (in the range $[1.6-3.2]\,h$). Considering that the cost of the embedding fluid phase scales like the cube of the particle radius, this result brings about a significant computational speed-up. Our code Fluam works in Graphics Processor Units (GPU's) and uses Fast Fourier Transform for the Poisson solver, which further improves its efficiency.
△ Less
Submitted 23 July, 2014; v1 submitted 21 July, 2014;
originally announced July 2014.