-
Scaling advantage in quantum simulation of geometrically frustrated magnets
Authors:
Andrew D. King,
Jack Raymond,
Trevor Lanting,
Sergei V. Isakov,
Masoud Mohseni,
Gabriel Poulin-Lamarre,
Sara Ejtemaee,
William Bernoudy,
Isil Ozfidan,
Anatoly Yu. Smirnov,
Mauricio Reis,
Fabio Altomare,
Michael Babcock,
Catia Baron,
Andrew J. Berkley,
Kelly Boothby,
Paul I. Bunyk,
Holly Christiani,
Colin Enderud,
Bram Evert,
Richard Harris,
Emile Hoskinson,
Shuiyuan Huang,
Kais Jooya,
Ali Khodabandelou
, et al. (29 additional authors not shown)
Abstract:
The promise of quantum computing lies in harnessing programmable quantum devices for practical applications such as efficient simulation of quantum materials and condensed matter systems. One important task is the simulation of geometrically frustrated magnets in which topological phenomena can emerge from competition between quantum and thermal fluctuations. Here we report on experimental observa…
▽ More
The promise of quantum computing lies in harnessing programmable quantum devices for practical applications such as efficient simulation of quantum materials and condensed matter systems. One important task is the simulation of geometrically frustrated magnets in which topological phenomena can emerge from competition between quantum and thermal fluctuations. Here we report on experimental observations of relaxation in such simulations, measured on up to 1440 qubits with microsecond resolution. By initializing the system in a state with topological obstruction, we observe quantum annealing (QA) relaxation timescales in excess of one microsecond. Measurements indicate a dynamical advantage in the quantum simulation over the classical approach of path-integral Monte Carlo (PIMC) fixed-Hamiltonian relaxation with multiqubit cluster updates. The advantage increases with both system size and inverse temperature, exceeding a million-fold speedup over a CPU. This is an important piece of experimental evidence that in general, PIMC does not mimic QA dynamics for stoquastic Hamiltonians. The observed scaling advantage, for simulation of frustrated magnetism in quantum condensed matter, demonstrates that near-term quantum devices can be used to accelerate computational tasks of practical relevance.
△ Less
Submitted 8 November, 2019;
originally announced November 2019.
-
A frequency and sensitivity tunable microresonator array for high-speed quantum processor readout
Authors:
J. D. Whittaker,
L. J. Swenson,
M. H. Volkmann,
P. Spear,
F. Altomare,
A. J. Berkley,
B. Bumble,
P. Bunyk,
P. K. Day,
B. H. Eom,
R. Harris,
J. P. Hilton,
E. Hoskinson,
M. W. Johnson,
A. Kleinsasser,
E. Ladizinsky,
T. Lanting,
T. Oh,
I. Perminov,
E. Tolkacheva,
J. Yao
Abstract:
Superconducting microresonators have been successfully utilized as detection elements for a wide variety of applications. With multiplexing factors exceeding 1,000 detectors per transmission line, they are the most scalable low-temperature detector technology demonstrated to date. For high-throughput applications, fewer detectors can be coupled to a single wire but utilize a larger per-detector ba…
▽ More
Superconducting microresonators have been successfully utilized as detection elements for a wide variety of applications. With multiplexing factors exceeding 1,000 detectors per transmission line, they are the most scalable low-temperature detector technology demonstrated to date. For high-throughput applications, fewer detectors can be coupled to a single wire but utilize a larger per-detector bandwidth. For all existing designs, fluctuations in fabrication tolerances result in a non-uniform shift in resonance frequency and sensitivity, which ultimately limits the efficiency of band-width utilization. Here we present the design, implementation, and initial characterization of a superconducting microresonator readout integrating two tunable inductances per detector. We demonstrate that these tuning elements provide independent control of both the detector frequency and sensitivity, allowing us to maximize the transmission line bandwidth utilization. Finally we discuss the integration of these detectors in a multilayer fabrication stack for high-speed readout of the D-Wave quantum processor, highlighting the use of control and routing circuitry composed of single flux-quantum loops to minimize the number of control wires at the lowest temperature stage.
△ Less
Submitted 22 April, 2016; v1 submitted 18 September, 2015;
originally announced September 2015.
-
Operation of a titanium nitride superconducting microresonator detector in the nonlinear regime
Authors:
L. J. Swenson,
P. K. Day,
B. H. Eom,
H. G. Leduc,
N. Llombart,
C. M. McKenney,
O. Noroozian,
J. Zmuidzinas
Abstract:
If driven sufficiently strongly, superconducting microresonators exhibit nonlinear behavior including response bifurcation. This behavior can arise from a variety of physical mechanisms including heating effects, grain boundaries or weak links, vortex penetration, or through the intrinsic nonlinearity of the kinetic inductance. Although microresonators used for photon detection are usually driven…
▽ More
If driven sufficiently strongly, superconducting microresonators exhibit nonlinear behavior including response bifurcation. This behavior can arise from a variety of physical mechanisms including heating effects, grain boundaries or weak links, vortex penetration, or through the intrinsic nonlinearity of the kinetic inductance. Although microresonators used for photon detection are usually driven fairly hard in order to optimize their sensitivity, most experiments to date have not explored detector performance beyond the onset of bifurcation. Here we present measurements of a lumped-element superconducting microresonator designed for use as a far-infrared detector and operated deep into the nonlinear regime. The 1 GHz resonator was fabricated from a 22 nm thick titanium nitride film with a critical temperature of 2 K and a normal-state resistivity of $100\, μΩ\,$cm. We measured the response of the device when illuminated with 6.4 pW optical loading using microwave readout powers that ranged from the low-power, linear regime to 18 dB beyond the onset of bifurcation. Over this entire range, the nonlinear behavior is well described by a nonlinear kinetic inductance. The best noise-equivalent power of $2 \times 10^{-16}$ W/Hz$^{1/2}$ at 10 Hz was measured at the highest readout power, and represents a $\sim$10 fold improvement compared with operating below the onset of bifurcation.
△ Less
Submitted 18 May, 2013;
originally announced May 2013.
-
High-speed phonon imaging using frequency-multiplexed kinetic inductance detectors
Authors:
L. J. Swenson,
A. Cruciani,
A. Benoit,
M. Roesch,
C. S. Yung,
A. Bideaud,
A. Monfardini
Abstract:
We present a measurement of phonon propagation in a silicon wafer utilizing an array of frequency-multiplexed superconducting resonators coupled to a single transmission line. The electronic readout permits fully synchronous array sampling with a per-resonator bandwidth of 1.2 MHz, allowing sub-$μ$s array imaging. This technological achievement is potentially vital in a variety of low-temperature…
▽ More
We present a measurement of phonon propagation in a silicon wafer utilizing an array of frequency-multiplexed superconducting resonators coupled to a single transmission line. The electronic readout permits fully synchronous array sampling with a per-resonator bandwidth of 1.2 MHz, allowing sub-$μ$s array imaging. This technological achievement is potentially vital in a variety of low-temperature applications, including single-photon counting, quantum-computing and dark-matter searches.
△ Less
Submitted 18 June, 2010; v1 submitted 28 April, 2010;
originally announced April 2010.
-
In-situ measurement of the permittivity of helium using microwave NbN resonators
Authors:
G. J. Grabovskij,
L. J. Swenson,
O. Buisson,
C. Hoffmann,
A. Monfardini,
J. -C. Villégier
Abstract:
By measuring the electrical transport properties of superconducting NbN quarter-wave resonators in direct contact with a helium bath, we have demonstrated a high-speed and spatially sensitive sensor for the permittivity of helium. In our implementation a $\sim10^{-3}$ mm$^3$ sensing volume is measured with a bandwidth of 300 kHz in the temperature range 1.8 to 8.8 K. The minimum detectable chang…
▽ More
By measuring the electrical transport properties of superconducting NbN quarter-wave resonators in direct contact with a helium bath, we have demonstrated a high-speed and spatially sensitive sensor for the permittivity of helium. In our implementation a $\sim10^{-3}$ mm$^3$ sensing volume is measured with a bandwidth of 300 kHz in the temperature range 1.8 to 8.8 K. The minimum detectable change of the permittivity of helium is calculated to be $\sim6\times$$10^{-11}$ $ε_0$/Hz$^{1/2}$ with a sensitivity of order $10^{-13}$ $ε_0$/Hz$^{1/2}$ easily achievable. Potential applications include operation as a fast, localized helium thermometer and as a transducer in superfluid hydrodynamic experiments.
△ Less
Submitted 29 September, 2008;
originally announced September 2008.
-
Mixing with the radiofrequency single-electron transistor
Authors:
L. J. Swenson,
D. R. Schmidt,
J. S. Aldridge,
D. K. Wood,
A. N. Cleland
Abstract:
By configuring a radio-frequency single-electron transistor as a mixer, we demonstrate a unique implementation of this device, that achieves good charge sensitivity with large bandwidth about a tunable center frequency. In our implementation we achieve a measurement bandwidth of 16 MHz, with a tunable center frequency from 0 to 1.2 GHz, demonstrated with the transistor operating at 300 mK. Ultim…
▽ More
By configuring a radio-frequency single-electron transistor as a mixer, we demonstrate a unique implementation of this device, that achieves good charge sensitivity with large bandwidth about a tunable center frequency. In our implementation we achieve a measurement bandwidth of 16 MHz, with a tunable center frequency from 0 to 1.2 GHz, demonstrated with the transistor operating at 300 mK. Ultimately this device is limited in center frequency by the RC time of the transistor's center island, which for our device is ~ 1.6 GHz, close to the measured value. The measurement bandwidth is determined by the quality factor of the readout tank circuit.
△ Less
Submitted 26 January, 2005;
originally announced January 2005.