-
Ferrimagnetic Oscillator Magnetometer
Authors:
John F. Barry,
Reed A. Irion,
Matthew H. Steinecker,
Daniel K. Freeman,
Jessica J. Kedziora,
Reginald G. Wilcox,
Danielle A. Braje
Abstract:
Quantum sensors offer unparalleled precision, accuracy, and sensitivity for a variety of measurement applications. We report a compact magnetometer based on a ferrimagnetic sensing element in an oscillator architecture that circumvents challenges common to other quantum sensing approaches such as limited dynamic range, limited bandwidth, and dependence on vacuum, cryogenic, or laser components. Th…
▽ More
Quantum sensors offer unparalleled precision, accuracy, and sensitivity for a variety of measurement applications. We report a compact magnetometer based on a ferrimagnetic sensing element in an oscillator architecture that circumvents challenges common to other quantum sensing approaches such as limited dynamic range, limited bandwidth, and dependence on vacuum, cryogenic, or laser components. The device exhibits a fixed, calibration-free response governed by the electron gyromagnetic ratio. Exchange narrowing in the ferrimagnetic material produces sub-MHz transition linewidths despite the high unpaired spin density ($\sim 10^{22}$ cm$^{-3}$). The magnetometer achieves a minimum sensitivity of 100 fT/$\sqrt{\text{Hz}}$ to AC magnetic fields of unknown phase and a sensitivity below 200 fT/$\sqrt{\text{Hz}}$ over a bandwidth $\gtrsim \! 1$ MHz. By encoding magnetic field in frequency rather than amplitude, the device provides a dynamic range in excess of 1 mT. The passive, thermal initialization of the sensor's quantum state requires only a magnetic bias field, greatly reducing power requirements compared to laser-initialized quantum sensors. With additional development, this device promises to be a leading candidate for high-performance magnetometry outside the laboratory, and the oscillator architecture is expected to provide advantages across a wide range of sensing platforms.
△ Less
Submitted 31 May, 2023;
originally announced May 2023.
-
Sensitive AC and DC Magnetometry with Nitrogen-Vacancy Center Ensembles in Diamond
Authors:
John F. Barry,
Matthew H. Steinecker,
Scott T. Alsid,
Jonah Majumder,
Linh M. Pham,
Michael F. O'Keefe,
Danielle A. Braje
Abstract:
Quantum sensing with solid-state spins offers the promise of high spatial resolution, bandwidth, and dynamic range at sensitivities comparable to more mature quantum sensing technologies, such as atomic vapor cells and superconducting devices. However, despite comparable theoretical sensitivity limits, the performance of bulk solid-state quantum sensors has so far lagged behind these more mature a…
▽ More
Quantum sensing with solid-state spins offers the promise of high spatial resolution, bandwidth, and dynamic range at sensitivities comparable to more mature quantum sensing technologies, such as atomic vapor cells and superconducting devices. However, despite comparable theoretical sensitivity limits, the performance of bulk solid-state quantum sensors has so far lagged behind these more mature alternatives. A recent review~\cite{barry2020sensitivity} suggests several paths to improve performance of magnetometers employing nitrogen-vacancy defects in diamond, the most-studied solid-state quantum sensing platform. Implementing several suggested techniques, we demonstrate the most sensitive nitrogen-vacancy-based bulk magnetometer reported to date. Our approach combines tailored diamond growth to achieve low strain and long intrinsic dephasing times, the use of double-quantum Ramsey and Hahn echo magnetometry sequences for broadband and narrowband magnetometry respectively, and P1 driving to further extend dephasing time. Notably, the device does not include a flux concentrator, preserving the fixed response of the NVs to magnetic field. The magnetometer realizes a broadband \textcolor{mhsnew}{near-}DC sensitivity $\sim 460$~fT$\cdot$s$^{1/2}$ and a narrowband AC sensitivity $\sim 210$~fT$\cdot$s$^{1/2}$. We describe the experimental setup in detail and highlight potential paths for future improvement.
△ Less
Submitted 10 May, 2023;
originally announced May 2023.
-
A Solid-State Microwave Magnetometer with Picotesla-Level Sensitivity
Authors:
Scott T. Alsid,
Jennifer M. Schloss,
Matthew H. Steinecker,
John F. Barry,
Andrew C. Maccabe,
Guoqing Wang,
Paola Cappellaro,
Danielle A. Braje
Abstract:
Quantum sensing of low-frequency magnetic fields using nitrogen-vacancy (NV) center ensembles has been demonstrated in multiple experiments with sensitivities as low as $\sim$1 pT/$\sqrt{\text{Hz}}$. To date, however, demonstrations of high-frequency magnetometry in the GHz regime with NV diamond are orders of magnitude less sensitive, above the nT/$\sqrt{\text{Hz}}$ level. Here we adapt for micro…
▽ More
Quantum sensing of low-frequency magnetic fields using nitrogen-vacancy (NV) center ensembles has been demonstrated in multiple experiments with sensitivities as low as $\sim$1 pT/$\sqrt{\text{Hz}}$. To date, however, demonstrations of high-frequency magnetometry in the GHz regime with NV diamond are orders of magnitude less sensitive, above the nT/$\sqrt{\text{Hz}}$ level. Here we adapt for microwave frequencies techniques that have enabled high-performance, low-frequency quantum sensors. Using a custom-grown NV-enriched diamond combined with a noise cancellation scheme designed for high-frequency sensing, we demonstrate a Rabi-sequence-based magnetometer able to detect microwave fields near 2.87 GHz with a record sensitivity of 3.4 pT/$\sqrt{\textrm{Hz}}$. We demonstrate both amplitude and phase sensing and project tunability over a 300 MHz frequency range. This result increases the viability of NV ensembles to serve as microwave circuitry imagers and near-field probes of antennas.
△ Less
Submitted 30 June, 2022;
originally announced June 2022.
-
Thermally-Polarized Solid-State Spin Sensor
Authors:
Reginald Wilcox,
Erik Eisenach,
John Barry,
Matthew Steinecker,
Michael O'Keeffe,
Dirk Englund,
Danielle Braje
Abstract:
Quantum sensors based on spin defect ensembles have seen rapid development in recent years, with a wide array of target applications. Historically, these sensors have used optical methods to prepare or read out quantum states. However, these methods are limited to optically-polarizable spin defects, and the spin ensemble size is typically limited by the available optical power or acceptable optica…
▽ More
Quantum sensors based on spin defect ensembles have seen rapid development in recent years, with a wide array of target applications. Historically, these sensors have used optical methods to prepare or read out quantum states. However, these methods are limited to optically-polarizable spin defects, and the spin ensemble size is typically limited by the available optical power or acceptable optical heat load. We demonstrate a solid-state sensor employing a non-optical state preparation technique, which harnesses thermal population imbalances induced by the defect's zero-field splitting. Readout is performed using the recently-demonstrated microwave cavity readout technique, resulting in a sensor architecture that is entirely non-optical and broadly applicable to all solid-state paramagnetic defects with a zero-field splitting. The implementation in this work uses Cr$^{3+}$ defects in a sapphire (Al$_2$O$_3$) crystal and a simple microwave architecture where the host crystal also serves as the high quality-factor resonator. This approach yields a near-unity filling factor and high single-spin-photon coupling, producing a magnetometer with a broadband sensitivity of 9.7 pT/$\sqrt{\text{Hz}}$.
△ Less
Submitted 3 September, 2021;
originally announced September 2021.
-
Cavity quantum electrodynamic readout of a solid-state spin sensor
Authors:
Erik R. Eisenach,
John F. Barry,
Michael F. O'Keeffe,
Jennifer M. Schloss,
Matthew H. Steinecker,
Dirk R. Englund,
Danielle A. Braje
Abstract:
Robust, high-fidelity readout is central to quantum device performance. Overcoming poor readout is an increasingly urgent challenge for devices based on solid-state spin defects, particularly given their rapid adoption in quantum sensing, quantum information, and tests of fundamental physics. Spin defects in solids combine the repeatability and precision available to atomic and cryogenic systems w…
▽ More
Robust, high-fidelity readout is central to quantum device performance. Overcoming poor readout is an increasingly urgent challenge for devices based on solid-state spin defects, particularly given their rapid adoption in quantum sensing, quantum information, and tests of fundamental physics. Spin defects in solids combine the repeatability and precision available to atomic and cryogenic systems with substantial advantages in compactness and range of operating conditions. However, in spite of experimental progress in specific systems, solid-state spin sensors still lack a universal, high-fidelity readout technique. Here we demonstrate high-fidelity, room-temperature readout of an ensemble of nitrogen-vacancy (NV) centers via strong coupling to a dielectric microwave cavity, building on similar techniques commonly applied in cryogenic circuit cavity quantum electrodynamics. This strong collective interaction allows the spin ensemble's microwave transition to be probed directly, thereby overcoming the optical photon shot noise limitations of conventional fluorescence readout. Applying this technique to magnetometry, we show magnetic sensitivity approaching the Johnson-Nyquist noise limit of the system. This readout technique is viable for the many paramagnetic spin systems that exhibit resonances in the microwave domain. Our results pave a clear path to achieve unity readout fidelity of solid-state spin sensors through increased ensemble size, reduced spin-resonance linewidth, or improved cavity quality factor.
△ Less
Submitted 2 March, 2020;
originally announced March 2020.
-
In-vacuum scattered light reduction with cupric oxide surfaces for sensitive fluorescence detection
Authors:
Eric B. Norrgard,
Nathan Sitaraman,
John F. Barry,
Daniel J. McCarron,
Matthew H. Steinecker,
David DeMille
Abstract:
We demonstrate a simple and easy method for producing low-reflectivity surfaces that are ultra-high vacuum compatible, may be baked to high temperatures, and are easily applied even on complex surface geometries. Black cupric oxide (CuO) surfaces are chemically grown in minutes on any copper surface, allowing for low-cost, rapid prototyping and production. The reflective properties are measured to…
▽ More
We demonstrate a simple and easy method for producing low-reflectivity surfaces that are ultra-high vacuum compatible, may be baked to high temperatures, and are easily applied even on complex surface geometries. Black cupric oxide (CuO) surfaces are chemically grown in minutes on any copper surface, allowing for low-cost, rapid prototyping and production. The reflective properties are measured to be comparable to commercially available products for creating optically black surfaces. We describe a vacuum apparatus which uses multiple blackened copper surfaces for sensitive, low-background detection of molecules using laser-induced fluorescence.
△ Less
Submitted 20 January, 2016;
originally announced January 2016.