-
Dynamic Lattice Distortions in Sr$_2$RuO$_4$: A microscopic study by perturbed angular correlation (TDPAC) spectroscopy
Authors:
S. N. Mishra,
M. Rots,
S. Cottenier
Abstract:
Applying time differential perturbed angular correlation (TDPAC) spectroscopy and \emph{ab initio} calculations, we have investigated possible lattice instabilities in Sr$_{2}$RuO$_{4}$ by studying the electric quadrupole interaction of a $^{111}$Cd probe at the Ru site. We find evidence for a dynamic lattice distortion, revealed from the observations of: (i) a rapidly fluctuating electric-field…
▽ More
Applying time differential perturbed angular correlation (TDPAC) spectroscopy and \emph{ab initio} calculations, we have investigated possible lattice instabilities in Sr$_{2}$RuO$_{4}$ by studying the electric quadrupole interaction of a $^{111}$Cd probe at the Ru site. We find evidence for a dynamic lattice distortion, revealed from the observations of: (i) a rapidly fluctuating electric-field gradient (EFG) tensor of which the main component decreases with decreasing temperature, and (ii) a monotonic increase of the EFG asymmetry ($η$) below 300 K. We argue that the observed dynamic lattice distortion is caused by strong spin fluctuations associated with the inherent magnetic instability of Sr$_{2}$RuO$_{4}$.
△ Less
Submitted 4 January, 2007;
originally announced January 2007.
-
Hyperfine interactions at lanthanide impurities in Fe
Authors:
Doru Torumba,
Stefaan Cottenier,
Veerle Vanhoof,
Michel Rots
Abstract:
The magnetic hyperfine field and electric-field gradient at isolated lanthanide impurities in an Fe host lattice are calculated from first principles, allowing for the first time a qualitative and quantitative understanding of an experimental data set collected over the past 40 years. It is demonstrated that the common Local Density Approximation leads to quantitatively and qualitatively wrong r…
▽ More
The magnetic hyperfine field and electric-field gradient at isolated lanthanide impurities in an Fe host lattice are calculated from first principles, allowing for the first time a qualitative and quantitative understanding of an experimental data set collected over the past 40 years. It is demonstrated that the common Local Density Approximation leads to quantitatively and qualitatively wrong results, while the LDA+U method performs much better. In order to avoid pitfalls inherent to the LDA+U method, a careful strategy had to be used, which will be described in detail. The lanthanide 4f spin moment is found to couple antiferromagnetically to the magnetization of the Fe lattice, in agreement with the model of Campbell and Brooks. There is strong evidence for a delocalization/localization transition that is shifted from Ce to at least Pr and maybe further up to Sm. This shift is interpreted in terms of the effective pressure felt by lanthanides in Fe. Implications for resolving ambiguities in the determination of delocalization in pure lanthanide metals under pressure are discussed. For the localized lanthanides, Yb is shown to be divalent in this host lattice, while all others are trivalent (including Eu, the case of Tm is undecided). The completely filled and well-bound 5p shell of the lanthanides is shown to have a major and unexpected influence on the dipolar hyperfine field and on the electric-field gradient, a feature that can be explained by their 1/r^3 dependence. An extrapolation to actinides suggests that the same is true for the actinide 6p shell. The case of free lanthanide atoms is discussed as well.
△ Less
Submitted 4 January, 2005;
originally announced January 2005.
-
The coordination dependence of electric-field gradients and hyperfine fields at 5sp impurities on fcc metal surfaces
Authors:
S. Cottenier,
V. Bellini,
M. Cakmak,
F. Manghi,
M. Rots
Abstract:
We present a comparison between accurate \textit{ab initio} calculations and a high-quality experimental data set (1986-2002) of electric-field gradients and magnetic hyperfine fields of Cd at different sites on Ni, Cu, Pd and Ag surfaces. Experiments found a systematic rule to assign surface sites on (100) and (111) surfaces based on the main component of the electric-field gradient, a rule tha…
▽ More
We present a comparison between accurate \textit{ab initio} calculations and a high-quality experimental data set (1986-2002) of electric-field gradients and magnetic hyperfine fields of Cd at different sites on Ni, Cu, Pd and Ag surfaces. Experiments found a systematic rule to assign surface sites on (100) and (111) surfaces based on the main component of the electric-field gradient, a rule that does not work for (110) surfaces. Our calculations show that this particular rule is a manifestation of a more general underlying systematic behavior. When looked upon from this point of view, (100), (111) \emph{and} (110) surfaces behave in precisely the same way. The experimentally observed parabolic coordination number dependence of the Cd magnetic hyperfine field at Ni surfaces is verified as a general trend, but we demonstrate that individual cases can significantly deviate from it. It is shown that the hyperfine fields of other 5sp impurities at Ni surfaces have their own, typical coordination number dependence. A microscopic explanation for the different dependencies is given in terms of the details of the s-DOS near the Fermi level.
△ Less
Submitted 12 December, 2003;
originally announced December 2003.
-
Valency of rare earths in RIn3 and RSn3: Ab initio analysis of electric-field gradients
Authors:
S. Jalali Asadabadi,
S. Cottenier,
H. Akbarzadeh,
R. Saki,
M. Rots
Abstract:
In RIn3 and RSn3 the rare earth (R) is trivalent, except for Eu and Yb, which are divalent. This was experimentally determined in 1977 by perturbed angular correlation measurements of the electric-field gradient on a 111Cd impurity. At that time, the data were interpreted using a point charge model, which is now known to be unphysical and unreliable. This makes the valency determination potentia…
▽ More
In RIn3 and RSn3 the rare earth (R) is trivalent, except for Eu and Yb, which are divalent. This was experimentally determined in 1977 by perturbed angular correlation measurements of the electric-field gradient on a 111Cd impurity. At that time, the data were interpreted using a point charge model, which is now known to be unphysical and unreliable. This makes the valency determination potentially questionable. We revisit these data, and analyze them using ab initio calculations of the electric-field gradient. From these calculations, the physical mechanism that is responsible for the influence of the valency on the electric-field gradient is derived. A generally applicable scheme to interpret electric-field gradients is used, which in a transparent way correlates the size of the field gradient with chemical properties of the system.
△ Less
Submitted 4 December, 2002; v1 submitted 1 December, 2002;
originally announced December 2002.