-
Endoscopic fiber-coupled diamond magnetometer for cancer surgery
Authors:
A. J. Newman,
S. M. Graham,
C. J. Stephen,
A. M. Edmonds,
M. L. Markham,
G. W. Morley
Abstract:
Interoperative measurements using magnetic sensors is a valuable technique in cancer surgery for finding magnetic tracers. Here we present a fiber-coupled nitrogen-vacancy (N-V) center magnetometer capable of detecting iron oxide suspension (MagTrace from Endomagnetics Ltd.) used in breast cancer surgeries. Detection of an iron mass as low as 0.56~mg has been demonstrated, 100 times less than that…
▽ More
Interoperative measurements using magnetic sensors is a valuable technique in cancer surgery for finding magnetic tracers. Here we present a fiber-coupled nitrogen-vacancy (N-V) center magnetometer capable of detecting iron oxide suspension (MagTrace from Endomagnetics Ltd.) used in breast cancer surgeries. Detection of an iron mass as low as 0.56~mg has been demonstrated, 100 times less than that of a recommended dose at a maximum distance of 5.8~mm. Detection of an iron concentration as low as 2.8 mg/ml has also been demonstrated, 20 times less than a recommended dose. The maximum working distance from the sensor can be as large as 14.6~mm for higher concentrations. The sensor head has a maximum diameter of 10~mm which would allow it to be used for endoscopy, laparoscopy and interoperative surgery.
△ Less
Submitted 8 April, 2025;
originally announced April 2025.
-
On the Road with a Diamond Magnetometer
Authors:
S. M. Graham,
A. J. Newman,
C. J. Stephen,
A. M. Edmonds,
D. J. Twitchen,
M. L. Markham,
G. W. Morley
Abstract:
Nitrogen vacancy centres in diamond can be used for vector magnetometry. In this work we present a portable vector diamond magnetometer. Its vector capability, combined with feedback control and robust structure enables operation on moving platforms. While placed on a trolley, magnetic mapping of a room is demonstrated and the magnetometer is also shown to be operational in a moving van with the m…
▽ More
Nitrogen vacancy centres in diamond can be used for vector magnetometry. In this work we present a portable vector diamond magnetometer. Its vector capability, combined with feedback control and robust structure enables operation on moving platforms. While placed on a trolley, magnetic mapping of a room is demonstrated and the magnetometer is also shown to be operational in a moving van with the measured magnetic field shifts for the x, y, and z axes being tagged with GPS coordinates. These magnetic field measurements are in agreement with measurements taken simultaneously with a fluxgate magnetometer.
△ Less
Submitted 31 January, 2024; v1 submitted 29 January, 2024;
originally announced January 2024.
-
Tensor gradiometry with a diamond magnetometer
Authors:
A. J. Newman,
S. M. Graham,
A. M. Edmonds,
D. J. Twitchen,
M. L. Markham,
G. W. Morley
Abstract:
Vector magnetometry provides more information than scalar measurements for magnetic surveys utilized in space, defense, medical, geological and industrial applications. These areas would benefit from a mobile vector magnetometer that can operate in extreme conditions. Here we present a scanning fiber-coupled nitrogen vacancy (NV) center vector magnetometer. Feedback control of the microwave excita…
▽ More
Vector magnetometry provides more information than scalar measurements for magnetic surveys utilized in space, defense, medical, geological and industrial applications. These areas would benefit from a mobile vector magnetometer that can operate in extreme conditions. Here we present a scanning fiber-coupled nitrogen vacancy (NV) center vector magnetometer. Feedback control of the microwave excitation frequency is employed to improve dynamic range and maintain sensitivity during movement of the sensor head. Tracking of the excitation frequency shifts for all four orientations of the NV center allow us to image the vector magnetic field of a damaged steel plate. We calculate the magnetic tensor gradiometry images in real time, and they allow us to detect smaller damage than is possible with vector or scalar imaging.
△ Less
Submitted 11 July, 2023;
originally announced July 2023.
-
Fiber-coupled Diamond Magnetometry with an Unshielded 30 pT/$\sqrt{\textrm{Hz}}$ Sensitivity
Authors:
S. M. Graham,
A. T. M. A. Rahman,
L. Munn,
R. L. Patel,
A. J. Newman,
C. J. Stephen,
G. Colston,
A. Nikitin,
A. M. Edmonds,
D. J. Twitchen,
M. L. Markham,
G. W. Morley
Abstract:
Ensembles of nitrogen vacancy centres (NVCs) in diamond can be employed for sensitive magnetometry. In this work we present a fiber-coupled NVC magnetometer with an unshielded sensitivity of (30 $\pm$ 10) pT/$\sqrt{\textrm{Hz}}$ in a (10 - 500)-Hz frequency range. This sensitivity is enabled by a relatively high green-to-red photon conversion efficiency, the use of a [100] bias field alignment, mi…
▽ More
Ensembles of nitrogen vacancy centres (NVCs) in diamond can be employed for sensitive magnetometry. In this work we present a fiber-coupled NVC magnetometer with an unshielded sensitivity of (30 $\pm$ 10) pT/$\sqrt{\textrm{Hz}}$ in a (10 - 500)-Hz frequency range. This sensitivity is enabled by a relatively high green-to-red photon conversion efficiency, the use of a [100] bias field alignment, microwave and lock-in amplifier (LIA) parameter optimisation, as well as a balanced hyperfine excitation scheme. Furthermore, a silicon carbide (SiC) heat spreader is used for microwave delivery, alongside low-strain $^{12}\textrm{C}$ diamonds, one of which is placed in a second magnetically insensitive fluorescence collecting sensor head for common-mode noise cancellation. The magnetometer is capable of detecting signals from sources such as a vacuum pump up to 2 m away, with some orientation dependence but no complete dead zones, demonstrating its potential for use in remote sensing applications.
△ Less
Submitted 23 March, 2023; v1 submitted 16 November, 2022;
originally announced November 2022.