-
The Casimir effect in graphene systems: Experiment and theory
Authors:
G. L. Klimchitskaya,
U. Mohideen,
V. M. Mostepanenko
Abstract:
The Casimir effect in graphene systems is reviewed with emphasis made on the large thermal correction to the Casimir force predicted at short separations between the test bodies. The computational results for the Casimir pressure and for the thermal correction are presented for both pristine graphene and real graphene sheets, which possess nonzero energy gap and chemical potential, obtained by mea…
▽ More
The Casimir effect in graphene systems is reviewed with emphasis made on the large thermal correction to the Casimir force predicted at short separations between the test bodies. The computational results for the Casimir pressure and for the thermal correction are presented for both pristine graphene and real graphene sheets, which possess nonzero energy gap and chemical potential, obtained by means of exact polarization tensor. Two experiments on measuring the gradient of the Casimir force between an Au-coated sphere and graphene- coated substrates performed by using a modified atomic force microscope cantilever-based technique are described. It is shown that the measurement data of both experiments are in agreement with theoretical predictions of the Lifshitz theory using the polarization tensor. Additionally, several important improvements made in the second experiment, allowed to demonstrate the predicted large thermal effect in the Casimir interaction at short separations. Possible implications of this result to resolution of long-term problems of Casimir physics are discussed.
△ Less
Submitted 28 April, 2022;
originally announced April 2022.
-
Experimental and theoretical investigation of the thermal effect in the Casimir interaction from graphene
Authors:
M. Liu,
Y. Zhang,
G. L. Klimchitskaya,
V. M. Mostepanenko,
U. Mohideen
Abstract:
We present the results of an experiment on measuring the gradient of the Casimir force between an Au-coated hollow glass microsphere and graphene-coated fused silica plate by means of a modified atomic force microscope cantilever based technique operated in the dynamic regime. These measurements were performed in high vacuum at room temperature. The energy gap and the concentration of impurities i…
▽ More
We present the results of an experiment on measuring the gradient of the Casimir force between an Au-coated hollow glass microsphere and graphene-coated fused silica plate by means of a modified atomic force microscope cantilever based technique operated in the dynamic regime. These measurements were performed in high vacuum at room temperature. The energy gap and the concentration of impurities in the graphene sample used have been measured utilizing scanning tunnelling spectroscopy and Raman spectroscopy, respectively. The measurement results for the gradients of the Casimir force are found to be in a very good agreement with theory using the polarization tensor of graphene at nonzero temperature depending on the energy gap and chemical potential with no fitting parameters. The theoretical predictions of the same theory at zero temperature are experimentally excluded over the measurement region from 250 to 517 nm. We have also investigated a dependence of the thermal correction to the Casimir force gradient on the values of the energy gap, chemical potential, and on the presence of a substrate supporting the graphene sheet. It is shown that the observed thermal effect is consistent in size with that arising for pristine graphene sheets if the impact of real conditions such as nonzero values of the energy gap, chemical potential, and the presence of a substrate is included. Implications of the obtained results to the resolution of the long-standing problems in Casimir physics are discussed. In addition to the paper published previously [M. Liu {\it et al}., Phys. Rev. Lett. {\bf 126}, 206802 (2021)], we present measurement results for the energy gap of the graphene sample, double the experimental data for the Casimir force, and perform a more complete theoretical analysis.
△ Less
Submitted 17 August, 2021;
originally announced August 2021.
-
Demonstration of an Unusual Thermal Effect in the Casimir Force from Graphene
Authors:
M. Liu,
Y. Zhang,
G. L. Klimchitskaya,
V. M. Mostepanenko,
U. Mohideen
Abstract:
We report precision measurements of the gradient of the Casimir force between an Au-coated sphere and graphene sheet deposited on a silica plate. The measurement data are compared with exact theory using the polarization tensor found in the framework of the Dirac model including effects of the nonzero chemical potential and energy gap of the graphene sample with no fitting parameters. The very goo…
▽ More
We report precision measurements of the gradient of the Casimir force between an Au-coated sphere and graphene sheet deposited on a silica plate. The measurement data are compared with exact theory using the polarization tensor found in the framework of the Dirac model including effects of the nonzero chemical potential and energy gap of the graphene sample with no fitting parameters. The very good agreement between experiment and theory demonstrates the unusually big thermal effect at separations below 1 mum which has never been observed for conventional 3D materials. Thus, it is confirmed experimentally that for graphene the effective temperature is determined by the Fermi velocity rather than by the speed of light.
△ Less
Submitted 11 May, 2021; v1 submitted 28 April, 2021;
originally announced April 2021.
-
Precision measurements of the gradient of the Casimir force between ultra clean metallic surfaces at larger separations
Authors:
Mingyue Liu,
Jun Xu,
G. L. Klimchitskaya,
V. M. Mostepanenko,
U. Mohideen
Abstract:
We report precision measurements of the Casimir interaction at larger separation distances between the Au-coated surfaces of a sphere and a plate in ultrahigh vacuum using a much softer cantilever of the dynamic atomic force microscope-based setup and two-step cleaning procedure of the vacuum chamber and test body surfaces by means of UV light and Ar-ion bombardment. Compared to the previously per…
▽ More
We report precision measurements of the Casimir interaction at larger separation distances between the Au-coated surfaces of a sphere and a plate in ultrahigh vacuum using a much softer cantilever of the dynamic atomic force microscope-based setup and two-step cleaning procedure of the vacuum chamber and test body surfaces by means of UV light and Ar-ion bombardment. Compared to the previously performed experiment, two more measurement sets for the gradient of the Casimir force are provided which confirmed and slightly improved the results. Next, additional measurements have been performed with a factor of two larger oscillation amplitude of the cantilever. This allowed obtaining meaningful results at much larger separation distances. The comparison of the measurement data with theoretical predictions of the Lifshitz theory using the dissipative Drude model to describe the response of Au to the low-frequency electromagnetic field fluctuations shows that this theoretical approach is experimentally excluded over the distances from 250 to 1100nm (i.e., a major step forward has been made as compared to the previous work where it was excluded up to only 820nm). The theoretical approach using the dissipationless plasma model at low frequencies is shown to be consistent with the data over the entire measurement range from 250 to 1300nm. The possibilities to explain these puzzling results are discussed.
△ Less
Submitted 21 November, 2019; v1 submitted 2 November, 2019;
originally announced November 2019.
-
Examining the Casimir puzzle with upgraded technique and advanced surface cleaning
Authors:
Mingyue Liu,
Jun Xu,
G. L. Klimchitskaya,
V. M. Mostepanenko,
U. Mohideen
Abstract:
We performed measurements of the gradient of the Casimir force between Au-coated surfaces of a sphere and a plate by means of significantly upgraded dynamic atomic force microscope (AFM) based technique. By introducing combined cleaning procedure of interior surfaces of the vacuum chamber and the test bodies by means of UV light and Ar ions, we reached higher vacuum and eliminated the role of elec…
▽ More
We performed measurements of the gradient of the Casimir force between Au-coated surfaces of a sphere and a plate by means of significantly upgraded dynamic atomic force microscope (AFM) based technique. By introducing combined cleaning procedure of interior surfaces of the vacuum chamber and the test bodies by means of UV light and Ar ions, we reached higher vacuum and eliminated the role of electrostatic patches. Furthermore, the use of much softer cantilever allowed a sixfold decrease of the systematic error in measuring the force gradient. The experimental data are compared with theoretical predictions of the Lifshitz theory taking into account corrections due to the inaccuracy of the proximity force approximation and that due to surface roughness. It is shown that the theoretical approach accounting for the relaxation properties of free electrons is excluded by the data up to a larger than previous sphere-plate separation of 820~nm, whereas an alternative approach is found in a very good agreement with the data. Importance of these results in connection with the foundations of quantum statistical physics is discussed.
△ Less
Submitted 2 August, 2019;
originally announced August 2019.
-
Theory of the Casimir interaction for graphene-coated substrates using the polarization tensor and comparison with experiment
Authors:
G. L. Klimchitskaya,
U. Mohideen,
V. M. Mostepanenko
Abstract:
We propose a theory of the thermal Casimir interaction for multilayered test bodies coated with a graphene sheet. The reflection coefficients on such structures are expressed in terms of the components of the polarization tensor and the dielectric permittivities of material layers. The developed theory is applied to calculate the gradient of the Casimir force between an Au-coated sphere and a grap…
▽ More
We propose a theory of the thermal Casimir interaction for multilayered test bodies coated with a graphene sheet. The reflection coefficients on such structures are expressed in terms of the components of the polarization tensor and the dielectric permittivities of material layers. The developed theory is applied to calculate the gradient of the Casimir force between an Au-coated sphere and a graphene sheet deposited on a SiO${}_2$ film covering a Si plate, which is the configuration of a recent experiment performed by means of a dynamic atomic force microscope. The theoretical results are found to be in very good agreement with the experimental data. We thus confirm that graphene influences the Casimir interaction and can be used for tailoring the force magnitude in nanostructures.
△ Less
Submitted 6 March, 2014;
originally announced March 2014.
-
Experimental and theoretical investigation of angular dependence of the Casimir force between sinusoidally corrugated surfaces
Authors:
A. A. Banishev,
J. Wagner,
T. Emig,
R. Zandi,
U. Mohideen
Abstract:
In the current work we present the complete results for the measurement of normal Casimir force between shallow and smooth sinusoidally corrugated gold coated sphere and a plate at various angles between the corrugations using an atomic force microscope. All measured data were compared with the theoretical approach using the proximity force approximation and theory based on derivative expansion. I…
▽ More
In the current work we present the complete results for the measurement of normal Casimir force between shallow and smooth sinusoidally corrugated gold coated sphere and a plate at various angles between the corrugations using an atomic force microscope. All measured data were compared with the theoretical approach using the proximity force approximation and theory based on derivative expansion. In both cases real material properties of the surfaces and non-zero temperature were taken into account. Special attention is paid to the description of electrostatic interactions between corrugated surfaces at different angels between corrugations and samples reparation and characterization. The measured forces are found to be in good agreement with the theory including correlation effects of geometry and material properties and deviate significantly from the predictions of the proximity force approximation approach. This provides the quantitative confirmation for the observation of diffraction-type effects that are disregarded within the PFA approach. The obtained results open new opportunities for control of the Casimir effect in micromechanical systems.
△ Less
Submitted 16 June, 2014; v1 submitted 11 February, 2014;
originally announced February 2014.
-
Investigation of the Casimir interaction between two magnetic metals in comparison with nonmagnetic test bodies
Authors:
A. A. Banishev,
G. L. Klimchitskaya,
V. M. Mostepanenko,
U. Mohideen
Abstract:
We present the complete results for the dynamic experiment on measuring the gradient of the Casimir force between magnetic (Ni-coated) surfaces of a plate and a sphere. Special attention is paid to the description of some details of the setup, its calibration, error analysis and background effects. Computations are performed in the framework of the Lifshitz theory at nonzero temperature with accou…
▽ More
We present the complete results for the dynamic experiment on measuring the gradient of the Casimir force between magnetic (Ni-coated) surfaces of a plate and a sphere. Special attention is paid to the description of some details of the setup, its calibration, error analysis and background effects. Computations are performed in the framework of the Lifshitz theory at nonzero temperature with account of analytic corrections to the proximity force approximation and of surface roughness using both the Drude and the plasma model approaches. The theory of magnetic interaction between a sphere and a plate due to domain structure of their surfaces is developed for both out-of-plane and in-plane magnetizations in the absence and in the presence of spontaneous magnetization. It is shown that in all cases the magnetic contribution to the measured force gradients is much smaller than the total experimental error. The comparison between experiment and theory is done using the rigorous statistical method. It is shown that the theoretical approach taking into account dissipation of free electrons is excluded by the data at a 95% confidence level. The approach neglecting dissipation is confirmed by the data at more than 90% confidence level. We prove that the results of experiments with Ni-Ni, Ni-Au and Au-Au surfaces taken together cannot be reconciled with the approach including free electrons dissipation by the introduction of any unaccounted background force, either attractive or repulsive.
△ Less
Submitted 23 March, 2014; v1 submitted 25 September, 2013;
originally announced September 2013.
-
Casimir interaction at liquid nitrogen temperature: Comparison between experiment and theory
Authors:
R. Castillo-Garza,
J. Xu,
G. L. Klimchitskaya,
V. M. Mostepanenko,
U. Mohideen
Abstract:
We have measured the normalized gradient of the Casimir force between Au-coated surfaces of the sphere and the plate and equivalent Casimir pressure between two parallel Au plates at T=77K. These measurements have been performed by means of dynamic force microscope adapted for operating at low temperatures in the frequency shift technique. It was shown that the measurement results at T=77K are in…
▽ More
We have measured the normalized gradient of the Casimir force between Au-coated surfaces of the sphere and the plate and equivalent Casimir pressure between two parallel Au plates at T=77K. These measurements have been performed by means of dynamic force microscope adapted for operating at low temperatures in the frequency shift technique. It was shown that the measurement results at T=77K are in a very good agreement with those at T=300K and with computations at T=77K using both theoretical approaches to the thermal Casimir force proposed in the literature. No thermal effect in the Casimir pressure was observed in the limit of experimental errors with the increase of temperature from T=77K to T=300K. Taking this into account, we have discussed the possible role of patch potentials in the comparison between measured and calculated Casimir pressures.
△ Less
Submitted 23 July, 2013;
originally announced July 2013.
-
Measuring the Casimir force gradient from graphene on a SiO_2 substrate
Authors:
A. A. Banishev,
H. Wen,
J. Xu,
R. K. Kawakami,
G. L. Klimchitskaya,
V. M. Mostepanenko,
U. Mohideen
Abstract:
The gradient of the Casimir force between a Si-SiO${}_2$-graphene substrate and an Au-coated sphere is measured by means of a dynamic atomic force microscope operated in the frequency shift technique. It is shown that the presence of graphene leads to up to 9% increase in the force gradient at the shortest separation considered. This is in qualitative agreement with the predictions of an additive…
▽ More
The gradient of the Casimir force between a Si-SiO${}_2$-graphene substrate and an Au-coated sphere is measured by means of a dynamic atomic force microscope operated in the frequency shift technique. It is shown that the presence of graphene leads to up to 9% increase in the force gradient at the shortest separation considered. This is in qualitative agreement with the predictions of an additive theory using the Dirac model of graphene.
△ Less
Submitted 27 May, 2013; v1 submitted 28 January, 2013;
originally announced January 2013.
-
Demonstration of Angle Dependent Casimir Force Between Corrugations
Authors:
A. A. Banishev,
J. Wagner,
T. Emig,
R. Zandi,
U. Mohideen
Abstract:
The normal Casimir force between a sinusoidally corrugated gold coated plate and a sphere was measured at various angles between the corrugations using an atomic force microscope. A strong dependence on the orientation angle of the corrugation is found. The measured forces were found to deviate from the proximity force approximation and are in agreement with the theory based on the gradient expans…
▽ More
The normal Casimir force between a sinusoidally corrugated gold coated plate and a sphere was measured at various angles between the corrugations using an atomic force microscope. A strong dependence on the orientation angle of the corrugation is found. The measured forces were found to deviate from the proximity force approximation and are in agreement with the theory based on the gradient expansion including correlation effects of geometry and material properties. We analyze the role of temperature. The obtained results open new opportunities for control of the Casimir effect in micromechanical systems.
△ Less
Submitted 3 May, 2013; v1 submitted 26 December, 2012;
originally announced December 2012.
-
Demonstration of the Casimir force between ferromagnetic surfaces of a Ni-coated sphere and a Ni-coated plate
Authors:
A. A. Banishev,
G. L. Klimchitskaya,
V. M. Mostepanenko,
U. Mohideen
Abstract:
We demonstrate the Casimir interaction between two ferromagnetic boundary surfaces using the dynamic atomic force microscope. The experimental data are found to be in excellent agreement with the predictions of the Lifshitz theory for magnetic boundary surfaces combined with the plasma model approach. It is shown that for magnetic materials the role of hypothetical patch potentials is opposite to…
▽ More
We demonstrate the Casimir interaction between two ferromagnetic boundary surfaces using the dynamic atomic force microscope. The experimental data are found to be in excellent agreement with the predictions of the Lifshitz theory for magnetic boundary surfaces combined with the plasma model approach. It is shown that for magnetic materials the role of hypothetical patch potentials is opposite to that required for reconciliation of the data with the Drude model.
△ Less
Submitted 29 March, 2013; v1 submitted 7 November, 2012;
originally announced November 2012.
-
How to modify the van der Waals and Casimir forces without change of dielectric permittivity
Authors:
G. L. Klimchitskaya,
U. Mohideen,
V. M. Mostepanenko
Abstract:
We propose a new experiment on measuring the Casimir force and its gradient between an Au-coated sphere and two different plates made of doped semiconductors. The concentrations of charge carriers in the plates are chosen slightly below and above the critical density at which the Mott-Anderson insulator-metal transition occurs. We calculate changes in the Casimir force and the Casimir pressure due…
▽ More
We propose a new experiment on measuring the Casimir force and its gradient between an Au-coated sphere and two different plates made of doped semiconductors. The concentrations of charge carriers in the plates are chosen slightly below and above the critical density at which the Mott-Anderson insulator-metal transition occurs. We calculate changes in the Casimir force and the Casimir pressure due to the insulator-metal transition using the standard Lifshitz theory and the phenomenological approach neglecting the contribution of free charge carriers in the dielectric permittivity of insulator materials (this approach was recently supported by the measurement data of several experiments). It is demonstrated that for the special selection of semiconductor materials (S- or Se-doped Si, B-doped diamond) calculation results using both theoretical approaches differ significantly and the predicted effects are easily detectable using the existing laboratory setups. In the case that the prediction of the phenomenological approach is confirmed, this would open opportunities to modify the van der Waals and Casimir forces with almost no change of room-temperature dielectric permittivity.
△ Less
Submitted 29 August, 2012;
originally announced August 2012.
-
Measurement of the gradient of the Casimir force between a nonmagnetic sphere and a magnetic plate
Authors:
A. A. Banishev,
C. -C. Chang,
G. L. Klimchitskaya,
V. M. Mostepanenko,
U. Mohideen
Abstract:
We measured the gradient of the Casimir force between an Au sphere and a plate made of ferromagnetic metal (Ni). It is demonstrated that the magnetic properties influence the force magnitude. This opens prospective opportunities for the control of the Casimir force in nanotechnology and for obtaining Casimir repulsion by using ferromagnetic dielectrics.
We measured the gradient of the Casimir force between an Au sphere and a plate made of ferromagnetic metal (Ni). It is demonstrated that the magnetic properties influence the force magnitude. This opens prospective opportunities for the control of the Casimir force in nanotechnology and for obtaining Casimir repulsion by using ferromagnetic dielectrics.
△ Less
Submitted 4 May, 2012;
originally announced May 2012.
-
A Discrete Two-Dimensional Model of a Loaded Cantilever Influenced by Time-Dependent Forces
Authors:
Gennady P. Berman,
Vyacheslav N. Gorshkov,
Vasily V. Kuzmenko,
Umar Mohideen
Abstract:
We developed a discrete two-dimensional model of a cantilever which incorporates the effects of inhomogeneity, the geometry of an attached particle, and the influence of external time-dependent forces. We provide a comparison between the solutions for our discrete model and its continuous limit. The rotational-vibrational mode is studied in detail. The results of numerical simulations demonstrate…
▽ More
We developed a discrete two-dimensional model of a cantilever which incorporates the effects of inhomogeneity, the geometry of an attached particle, and the influence of external time-dependent forces. We provide a comparison between the solutions for our discrete model and its continuous limit. The rotational-vibrational mode is studied in detail. The results of numerical simulations demonstrate usefulness of our model for many applications when a cantilever has a complicated geometry and is affected by time-depended and distributed external forces.
△ Less
Submitted 16 April, 2012;
originally announced April 2012.
-
Gradient of the Casimir force between Au surfaces of a sphere and a plate measured using atomic force microscope in a frequency shift technique
Authors:
C. -C. Chang,
A. A. Banishev,
R. Castillo-Garza,
G. L. Klimchitskaya,
V. M. Mostepanenko,
U. Mohideen
Abstract:
We present measurement results for the gradient of the Casimir force between an Au-coated sphere and an Au-coated plate obtained by means of an atomic force microscope operated in a frequency shift technique. This experiment was performed at a pressure of 3x10^{-8} Torr with hollow glass sphere of 41.3 mcm radius. Special attention is paid to electrostatic calibrations including the problem of ele…
▽ More
We present measurement results for the gradient of the Casimir force between an Au-coated sphere and an Au-coated plate obtained by means of an atomic force microscope operated in a frequency shift technique. This experiment was performed at a pressure of 3x10^{-8} Torr with hollow glass sphere of 41.3 mcm radius. Special attention is paid to electrostatic calibrations including the problem of electrostatic patches. All calibration parameters are shown to be separation-independent after the corrections for mechanical drift are included. The gradient of the Casimir force was measured in two ways with applied compensating voltage to the plate and with different applied voltages and subsequent subtraction of electric forces. The obtained mean gradients are shown to be in mutual agreement and in agreement with previous experiments performed using a micromachined oscillator. The obtained data are compared with theoretical predictions of the Lifshitz theory including corrections beyond the proximity force approximation. An independent comparison with no fitting parameters demonstrated that the Drude model approach is excluded by the data at a 67% confidence level over the separation region from 235 to 420 nm. The theoretical approach using the generalized plasma-like model is shown to be consistent with the data over the entire measurement range. Corrections due to the nonlinearity of oscillator are calculated and the application region of the linear regime is determined. A conclusion is made that the results of several performed experiments call for a thorough analysis of the basics of the theory of dispersion forces.
△ Less
Submitted 14 April, 2012;
originally announced April 2012.
-
Collective charge fluctuations and Casimir interactions for quasi one-dimensional metals
Authors:
Ehsan Noruzifar,
Thorsten Emig,
Umar Mohideen,
Roya Zandi
Abstract:
We investigate the Casimir interaction between two parallel metallic cylinders and between a metallic cylinder and plate. The material properties of the metallic objects are implemented by the plasma, Drude and perfect metal model dielectric functions. We calculate the Casimir interaction numerically at all separation distances and analytically at large separations. The large-distance asymptotic i…
▽ More
We investigate the Casimir interaction between two parallel metallic cylinders and between a metallic cylinder and plate. The material properties of the metallic objects are implemented by the plasma, Drude and perfect metal model dielectric functions. We calculate the Casimir interaction numerically at all separation distances and analytically at large separations. The large-distance asymptotic interaction between one plasma cylinder parallel to another plasma cylinder or plate does not depend on the material properties, but for a Drude cylinder it depends on the dc conductivity $σ$. At intermediate separations, for plasma cylinders the asymptotic interaction depends on the plasma wave length $λ_{\rm p}$ while for Drude cylinders the Casimir interaction can become independent of the material properties. We confirm the analytical results by the numerics and show that at short separations, the numerical results approach the proximity force approximation.
△ Less
Submitted 27 March, 2012;
originally announced March 2012.
-
Observation of reduction in Casimir force without change of dielectric permittivity
Authors:
A. A. Banishev,
C. -C. Chang,
R. Castillo-Garza,
G. L. Klimchitskaya,
V. M. Mostepanenko,
U. Mohideen
Abstract:
Additional information is provided on the effect of the significant (up to 35%) reduction in the magnitude of the Casimir force between an Au-coated sphere and an indium tin oxide film which was observed after UV treatment of the latter. A striking feature of this effect is that the reduction is not accompanied with a corresponding variation of the dielectric permittivity, as confirmed by direct e…
▽ More
Additional information is provided on the effect of the significant (up to 35%) reduction in the magnitude of the Casimir force between an Au-coated sphere and an indium tin oxide film which was observed after UV treatment of the latter. A striking feature of this effect is that the reduction is not accompanied with a corresponding variation of the dielectric permittivity, as confirmed by direct ellipsometry measurements. The measurement data are compared with computations using the Lifshitz theory. It is shown that the data for the untreated sample are in a very good agreement with theory taking into account the free charge carriers in the indium tin oxide. The data for the UV-treated sample exclude the theoretical results obtained with account of free charge carriers. These data are found to be in a very good agreement with theory disregarding the free charge carriers in an indium tin oxide film. A possible theoretical explanation of our observations as a result of phase transition of indium tin oxide from metallic to dielectric state is discussed in comparison with other related experiments.
△ Less
Submitted 2 February, 2012;
originally announced February 2012.
-
Reduction of the Casimir force from indium tin oxide film by UV treatment
Authors:
C. C. Chang,
A. A. Banishev,
G. L. Klimchitskaya,
V. M. Mostepanenko,
U. Mohideen
Abstract:
A significant decrease in the magnitude of the Casimir force (from 21% to 35%) was observed after an indium tin oxide (ITO) sample interacting with an Au sphere was subjected to the UV treatment. Measurements were performed by using an atomic force microscope (AFM) in high vacuum. The experimental results are compared with theory, and a hypothetical explanation for the observed phenomenon is propo…
▽ More
A significant decrease in the magnitude of the Casimir force (from 21% to 35%) was observed after an indium tin oxide (ITO) sample interacting with an Au sphere was subjected to the UV treatment. Measurements were performed by using an atomic force microscope (AFM) in high vacuum. The experimental results are compared with theory, and a hypothetical explanation for the observed phenomenon is proposed.
△ Less
Submitted 3 August, 2011;
originally announced August 2011.
-
Control of the Casimir Force Using Semiconductor Test Bodies
Authors:
G. L. Klimchitskaya,
U. Mohideen,
V. M. Mostepanenko
Abstract:
We describe experimental and related theoretical work on the measurement of the Casimir force using semiconductor test bodies. This field of research started in 2005 and several important and interesting results have already been obtained. Specifically, the Casimir force or its gradient were measured in the configuration of an Au-coated sphere and different semiconductor surfaces. It was found tha…
▽ More
We describe experimental and related theoretical work on the measurement of the Casimir force using semiconductor test bodies. This field of research started in 2005 and several important and interesting results have already been obtained. Specifically, the Casimir force or its gradient were measured in the configuration of an Au-coated sphere and different semiconductor surfaces. It was found that the force magnitude depends significantly on the replacement of the metal with a semiconductor and on the concentration of charge carriers in the semiconductor material. Special attention is paid to the experiment on the optical modulation of the Casimir force. In this experiment the difference Casimir force between an Au-coated sphere and Si plate in the presence and in the absence of laser light was measured. Possible applications of this experiment are discussed, specifically, for the realization of the pulsating Casimir force in three-layer systems. Theoretical problems arising from the comparison of the experimental data for the difference Casimir force with the Lifshitz theory are analyzed. We consider the possibility to control the magnitude of the Casimir force in phase transitions of semiconductor materials. Experiments on measuring the Casimir force gradient between an Au-coated sphere and Si plate covered with rectangular corrugations of different character are also described. Here, we discuss the interplay between the material properties and nontrivial geometry and the applicability of the proximity force approximation. The review contains comparison between different experiments and analysis of their advantages and disadvantages.
△ Less
Submitted 9 April, 2011;
originally announced April 2011.
-
Impact of surface imperfections on the Casimir force for lenses of centimeter-size curvature radii
Authors:
V. B. Bezerra,
G. L. Klimchitskaya,
U. Mohideen,
V. M. Mostepanenko,
C. Romero
Abstract:
The impact of imperfections, which are always present on surfaces of lenses with centimeter-size curvature radii, on the Casimir force in the lens-plate geometry is investigated. It is shown that the commonly used formulation of the proximity force approximation is inapplicable for spherical lenses with surface imperfections, such as bubbles and pits. More general expressions for the Casimir force…
▽ More
The impact of imperfections, which are always present on surfaces of lenses with centimeter-size curvature radii, on the Casimir force in the lens-plate geometry is investigated. It is shown that the commonly used formulation of the proximity force approximation is inapplicable for spherical lenses with surface imperfections, such as bubbles and pits. More general expressions for the Casimir force are derived that take surface imperfections into account. Using these expressions we show that surface imperfections can both increase and decrease the magnitude of the Casimir force up to a few tens of percent when compared with the case of a perfectly spherical lens. We demonstrate that the Casimir force between a perfectly spherical lens and a plate described by the Drude model can be made approximately equal to the force between a sphere with some surface imperfection and a plate described by the plasma model, and vice versa. In the case of a metallic sphere and semiconductor plate, approximately the same Casimir forces are obtained for four different descriptions of charge carriers in the semiconductor if appropriate surface imperfections on the lens surface are present. The conclusion is made that there is a fundamental problem in the interpretation of measurement data for the Casimir force, obtained by using spherical lenses of centimeter-size radii, and their comparison with theory.
△ Less
Submitted 10 January, 2011;
originally announced January 2011.
-
Fluctuation-induced forces between inclusions in a fluid membrane under tension
Authors:
Hsiang-Ku Lin,
Roya Zandi,
Umar Mohideen,
Leonid P. Pryadko
Abstract:
We discuss the fluctuation-induced force, a finite-temperature analog of the Casimir force, between two inclusions embedded in a fluid membrane under tension. We suggest a method to calculate this Casimir interaction in the most general case, where membrane fluctuations are governed by the combined action of surface tension, bending modulus, and the Gaussian rigidity. We find that the surface tens…
▽ More
We discuss the fluctuation-induced force, a finite-temperature analog of the Casimir force, between two inclusions embedded in a fluid membrane under tension. We suggest a method to calculate this Casimir interaction in the most general case, where membrane fluctuations are governed by the combined action of surface tension, bending modulus, and the Gaussian rigidity. We find that the surface tension strongly modifies the power law in the separation dependence of the Casimir interaction. This results in a strong suppression of the Casimir force at separations beyond a characteristic length, which could affect protein aggregation dynamics in cell membranes.
△ Less
Submitted 23 September, 2011; v1 submitted 3 September, 2010;
originally announced September 2010.
-
Quantum and thermal Casimir interaction between a sphere and a plate: Comparison of Drude and plasma models
Authors:
Roya Zandi,
Thorsten Emig,
Umar Mohideen
Abstract:
We calculate the Casimir interaction between a sphere and a plate, both described by the plasma model, the Drude model, or generalizations of the two models. We compare the results at both zero and finite temperatures. At asymptotically large separations we obtain analytical results for the interaction that reveal a non-universal, i.e., material dependent interaction for the plasma model. The la…
▽ More
We calculate the Casimir interaction between a sphere and a plate, both described by the plasma model, the Drude model, or generalizations of the two models. We compare the results at both zero and finite temperatures. At asymptotically large separations we obtain analytical results for the interaction that reveal a non-universal, i.e., material dependent interaction for the plasma model. The latter result contains the asymptotic interaction for Drude metals and perfect reflectors as different but universal limiting cases. This observation is related to the screening of a static magnetic field by a London superconductor. For small separations we find corrections to the proximity force approximation (PFA) that support correlations between geometry and material properties that are not captured by the Lifshitz theory. Our results at finite temperatures reveal for Drude metals a non-monotonic temperature dependence of the Casimir free energy and a negative entropy over a sizeable range of separations.
△ Less
Submitted 27 February, 2010;
originally announced March 2010.
-
Lateral Casimir force between sinusoidally corrugated surfaces: Asymmetric profiles, deviations from the proximity force approximation and comparison with exact theory
Authors:
H. -C. Chiu,
G. L. Klimchitskaya,
V. N. Marachevsky,
V. M. Mostepanenko,
U. Mohideen
Abstract:
The lateral Casimir force, which arises between aligned sinusoidally corrugated surfaces of a sphere and a plate, was measured for the case of a small corrugation period beyond the applicability region of the proximity force approximation. The increased amplitudes of the corrugations on both the sphere and the plate allowed observation of an asymmetry of the lateral Casimir force, i.e., deviatio…
▽ More
The lateral Casimir force, which arises between aligned sinusoidally corrugated surfaces of a sphere and a plate, was measured for the case of a small corrugation period beyond the applicability region of the proximity force approximation. The increased amplitudes of the corrugations on both the sphere and the plate allowed observation of an asymmetry of the lateral Casimir force, i.e., deviation of its profile from a perfect sine function. The dependences of the lateral force on the phase shift between the corrugations on both test bodies were measured at different separations in two sets of measurements with different amplitudes of corrugations on the sphere. The maximum magnitude of the lateral force as a function of separation was also measured in two successive experiments. All measurement data were compared with the theoretical approach using the proximity force approximation and with the exact theory based on Rayleigh expansions with no fitting parameters. In both cases real material properties of the test bodies and nonzero temperature were taken into account. The data were found to be in a good agreement with the exact theory but deviate significantly from the predictions of the proximity force approximation approach. This provides the quantitative confirmation for the observation of diffraction-type effects that are disregarded within the PFA approach. Possible applications of the phenomenon of the lateral Casimir force in nanotechnology for the operation of micromachines are discussed.
△ Less
Submitted 20 February, 2010;
originally announced February 2010.
-
An IR Photodetector Using an Optically Cooled Micromirror as a Light Pressure Sensor
Authors:
Gennady P. Berman,
Boris M. Chernobrod,
Alan R. Bishop,
Umar Mohideen
Abstract:
We consider mid-infrared (5 to 25 micrometers), optically cooled detectors based on a microcantilever sensor of the radiation pressure. A significant enhancement of sensitivity is achieved due the combination of low effective temperature (10 K), non-absorption detection, and a high quality optical microcavity. Applications to spectrometry are examined. It is shown that an optically cooled radiat…
▽ More
We consider mid-infrared (5 to 25 micrometers), optically cooled detectors based on a microcantilever sensor of the radiation pressure. A significant enhancement of sensitivity is achieved due the combination of low effective temperature (10 K), non-absorption detection, and a high quality optical microcavity. Applications to spectrometry are examined. It is shown that an optically cooled radiation pressure sensor potentially has a sensitivity an order of magnitude better than the best conventional uncooled detectors.
△ Less
Submitted 21 December, 2009;
originally announced December 2009.
-
Demonstration of the asymmetric lateral Casimir force between corrugated surfaces in the nonadditive regime
Authors:
H. -C. Chiu,
G. L. Klimchitskaya,
V. N. Marachevsky,
V. M. Mostepanenko,
U. Mohideen
Abstract:
The measurement of the lateral Casimir force between two aligned sinusoidally corrugated Au-coated surfaces has been performed in the nonadditive regime. The use of deeper corrugations also allowed to demonstrate an asymmetry in the phase dependences of the lateral Casimir force, as predicted earlier. The measurement data are found to be in excellent agreement with the exact theoretical results…
▽ More
The measurement of the lateral Casimir force between two aligned sinusoidally corrugated Au-coated surfaces has been performed in the nonadditive regime. The use of deeper corrugations also allowed to demonstrate an asymmetry in the phase dependences of the lateral Casimir force, as predicted earlier. The measurement data are found to be in excellent agreement with the exact theoretical results computed at T=300 K including effect of real material properties. The deviations between the exact theory and the proximity force approximation are quantified. The obtained results are topical for applications in nanomachines.
△ Less
Submitted 11 September, 2009;
originally announced September 2009.
-
The Casimir force between real materials: experiment and theory
Authors:
G. L. Klimchitskaya,
U. Mohideen,
V. M. Mostepanenko
Abstract:
The physical origin of the Casimir force is connected with the existence of zero-point and thermal fluctuations. The Casimir effect is very general and finds applications in various fields of physics. This review is limited to the rapid progress at the intersection of experiment and theory that has been achieved in the last few years. It includes a critical assessment of the proposed approaches…
▽ More
The physical origin of the Casimir force is connected with the existence of zero-point and thermal fluctuations. The Casimir effect is very general and finds applications in various fields of physics. This review is limited to the rapid progress at the intersection of experiment and theory that has been achieved in the last few years. It includes a critical assessment of the proposed approaches to the resolution of the puzzles arising in the applications of the Lifshitz theory of the van der Waals and Casimir forces to real materials. All the primary experiments on the measurement of the Casimir force between macroscopic bodies and the Casimir-Polder force between an atom and a wall that have been performed in the last decade are reviewed, including the theory needed for their interpretation. The methodology for the comparison between experiment and theory in the force-distance measurements is presented. The experimental and theoretical results described here provide a deeper understanding of the phenomenon of dispersion forces in real materials and offer guidance for the application of Lifshitz theory for the interpretation of the measurement results.
△ Less
Submitted 23 February, 2009;
originally announced February 2009.
-
Comment on "Application of the Lifshitz theory to poor conductors" [arXiv:0809.3901]
Authors:
G. L. Klimchitskaya,
U. Mohideen,
V. M. Mostepanenko
Abstract:
Recent Letter by V. B. Svetovoy [Phys. Rev. Lett. v.101, 163603 (2008), arXiv:0809.3901] claims that the Lifshitz theory combined with spatially nonlocal dielectric permittivities is consistent with the experimental data and Nernst's theorem. We prove that these claims are incorrect. They are based on irregular comparison with the data and misinterpretation of relevant physical quantities.
Recent Letter by V. B. Svetovoy [Phys. Rev. Lett. v.101, 163603 (2008), arXiv:0809.3901] claims that the Lifshitz theory combined with spatially nonlocal dielectric permittivities is consistent with the experimental data and Nernst's theorem. We prove that these claims are incorrect. They are based on irregular comparison with the data and misinterpretation of relevant physical quantities.
△ Less
Submitted 17 October, 2008;
originally announced October 2008.
-
Experimental procedures for precision measurements of the Casimir force with an Atomic Force Microscope
Authors:
Hsiang-Chih Chiu,
Chia-Cheng Chang,
R. Castillo-Garza,
F. Chen,
U. Mohideen
Abstract:
Experimental methods and procedures required for precision measurements of the Casimir force are presented. In particular, the best practices for obtaining stable cantilevers, calibration of the cantilever, correction of thermal and mechanical drift, measuring the contact separation, sphere radius and the roughness are discussed.
Experimental methods and procedures required for precision measurements of the Casimir force are presented. In particular, the best practices for obtaining stable cantilevers, calibration of the cantilever, correction of thermal and mechanical drift, measuring the contact separation, sphere radius and the roughness are discussed.
△ Less
Submitted 25 February, 2008;
originally announced February 2008.
-
Comment on ``Precision measurement of the Casimir-Lifshitz force in a fluid''
Authors:
B. Geyer,
G. L. Klimchitskaya,
U. Mohideen,
V. M. Mostepanenko
Abstract:
Recently J.N. Munday and F. Capasso [Phys. Rev. A {\bf 75}, 060102(R) (2007); arXiv:0705.3793] claimed that they have performed a precision measurement of the Casimir force between a sphere and a plate coated with Au, both immersed in ethanol. The measurement results were claimed to be consistent with the Lifshitz theory. We demonstrate that the calculation of the Casimir force between the smoot…
▽ More
Recently J.N. Munday and F. Capasso [Phys. Rev. A {\bf 75}, 060102(R) (2007); arXiv:0705.3793] claimed that they have performed a precision measurement of the Casimir force between a sphere and a plate coated with Au, both immersed in ethanol. The measurement results were claimed to be consistent with the Lifshitz theory. We demonstrate that the calculation of the Casimir force between the smooth bodies following the authors prescription has a discrepancy up to 25% with respect to authors result. We show also that the attractive electrostatic force only due to the surface potential differences was underestimated by a factor of 590 and the charge double layer interaction was not taken into account. All this leads to the conclusion that the results of this experiment are in fact uncertain.
△ Less
Submitted 16 November, 2007; v1 submitted 11 August, 2007;
originally announced August 2007.
-
Control of the Casimir force by the modification of dielectric properties with light
Authors:
F. Chen,
G. L. Klimchitskaya,
V. M. Mostepanenko,
U. Mohideen
Abstract:
The experimental demonstration of the modification of the Casimir force between a gold coated sphere and a single-crystal Si membrane by light pulses is performed. The specially designed and fabricated Si membrane was irradiated with 514 nm laser pulses of 5 ms width in high vacuum leading to a change of the charge-carrier density. The difference in the Casimir force in the presence and in the a…
▽ More
The experimental demonstration of the modification of the Casimir force between a gold coated sphere and a single-crystal Si membrane by light pulses is performed. The specially designed and fabricated Si membrane was irradiated with 514 nm laser pulses of 5 ms width in high vacuum leading to a change of the charge-carrier density. The difference in the Casimir force in the presence and in the absence of laser radiation was measured by means of an atomic force microscope as a function of separation at different powers of the absorbed light. The total experimental error of the measured force differences at a separation of 100 nm varies from 10 to 20% in different measurements. The experimental results are compared with theoretical computations using the Lifshitz theory at both zero and laboratory temperatures. The total theoretical error determined mostly by the uncertainty in the concentration of charge carriers when the light is incident is found to be about 14% at separations less than 140 nm. The experimental data are consistent with the Lifshitz theory at laboratory temperature, if the static dielectric permittivity of high-resistivity Si in the absence of light is assumed to be finite. If the dc conductivity of high-resistivity Si in the absence of light is included into the model of dielectric response, the Lifshitz theory at nonzero temperature is shown to be experimentally inconsistent at 95% confidence. The demonstrated phenomenon of the modification of the Casimir force through a change of the charge-carrier density is topical for applications of the Lifshitz theory to real materials in fields ranging from nanotechnology and condensed matter physics to the theory of fundamental interactions.
△ Less
Submitted 30 July, 2007;
originally announced July 2007.
-
Kramers-Kronig relations for plasma-like permittivities and the Casimir force
Authors:
G. L. Klimchitskaya,
U. Mohideen,
V. M. Mostepanenko
Abstract:
The Kramers-Kronig relations are derived for the permittivity of the usual plasma model which neglects dissipation and of a generalized model which takes into account the interband transitions. The generalized plasma model is shown to be consistent with all precision experiments on the measurement of the Casimir force.
The Kramers-Kronig relations are derived for the permittivity of the usual plasma model which neglects dissipation and of a generalized model which takes into account the interband transitions. The generalized plasma model is shown to be consistent with all precision experiments on the measurement of the Casimir force.
△ Less
Submitted 15 March, 2007;
originally announced March 2007.
-
Comment on ``Lateral Casimir force beyond the proximity-force approximation''
Authors:
F. Chen,
U. Mohideen,
G. L. Klimchitskaya,
V. M. Mostepanenko
Abstract:
We demonstrate that the approach by Rodrigues et al. (PRL, v.96, 100402, 2006) to the description of the lateral Casimir force between corrugated surfaces is in disagreement with a path-integral theory by Emig et al. (PRA, v.67, 022114, 2003), and the approximations used are not appropriate for comparison to experiment.
We demonstrate that the approach by Rodrigues et al. (PRL, v.96, 100402, 2006) to the description of the lateral Casimir force between corrugated surfaces is in disagreement with a path-integral theory by Emig et al. (PRA, v.67, 022114, 2003), and the approximations used are not appropriate for comparison to experiment.
△ Less
Submitted 6 February, 2007;
originally announced February 2007.
-
Demonstration of optically modulated dispersion forces
Authors:
F. Chen,
G. L. Klimchitskaya,
V. M. Mostepanenko,
U. Mohideen
Abstract:
We report the first experiment on the optical modulation of dispersion forces through a change of the carrier density in a Si membrane. For this purpose a high-vacuum based atomic force microscope and excitation light pulses from an Ar laser are used. The experimental results are compared with two theoretical models. The modulation of the dispersion force will find applications in optomechanical…
▽ More
We report the first experiment on the optical modulation of dispersion forces through a change of the carrier density in a Si membrane. For this purpose a high-vacuum based atomic force microscope and excitation light pulses from an Ar laser are used. The experimental results are compared with two theoretical models. The modulation of the dispersion force will find applications in optomechanical micromachines.
△ Less
Submitted 5 April, 2007; v1 submitted 12 October, 2006;
originally announced October 2006.
-
Demonstration of the difference Casimir force for samples with different charge carrier densities
Authors:
F. Chen,
G. L. Klimchitskaya,
V. M. Mostepanenko,
U. Mohideen
Abstract:
A measurement of the Casimir force between a gold coated sphere and two Si plates of different carrier densities is performed using a high vacuum based atomic force microscope. The results are compared with the Lifshitz theory and good agreement is found. Our experiment demonstrates that by changing the carrier density of the semiconductor plate by several orders of magnitude it is possible to m…
▽ More
A measurement of the Casimir force between a gold coated sphere and two Si plates of different carrier densities is performed using a high vacuum based atomic force microscope. The results are compared with the Lifshitz theory and good agreement is found. Our experiment demonstrates that by changing the carrier density of the semiconductor plate by several orders of magnitude it is possible to modify the Casimir interaction. This result may find applications in nanotechnology.
△ Less
Submitted 26 September, 2006;
originally announced September 2006.
-
Experimental test for the conductivity properties from the Casimir force between metal and semiconductor
Authors:
F. Chen,
U. Mohideen,
G. L. Klimchitskaya,
V. M. Mostepanenko
Abstract:
The experimental investigation of the Casimir force between a large metallized sphere and semiconductor plate is performed using an atomic force microscope. Improved calibration and measurement procedures permitted reduction in the role of different uncertainties. Rigorous statistical procedures are applied for the analysis of random, systematic and total experimental errors at 95% confidence. T…
▽ More
The experimental investigation of the Casimir force between a large metallized sphere and semiconductor plate is performed using an atomic force microscope. Improved calibration and measurement procedures permitted reduction in the role of different uncertainties. Rigorous statistical procedures are applied for the analysis of random, systematic and total experimental errors at 95% confidence. The theoretical Casimir force is computed for semiconductor plates with different conductivity properties taking into account all theoretical uncertainties discussed in literature. The comparison between experiment and theory is done at both 95 and 70% confidence. It is demonstrated that the theoretical results computed for the semiconductor plate used in experiment are consistent with data. At the same time, theory describing a dielectric plate is excluded by experiment at 70% confidence. Thus, the Casimir force is proved to be sensitive to the conductivity properties of semiconductors.
△ Less
Submitted 13 March, 2006;
originally announced March 2006.
-
Rigorous approach to the comparison between experiment and theory in Casimir force measurements
Authors:
G. L. Klimchitskaya,
F. Chen,
R. S. Decca,
E. Fischbach,
D. E. Krause,
D. Lopez,
U. Mohideen,
V. M. Mostepanenko
Abstract:
In most experiments on the Casimir force the comparison between measurement data and theory was done using the concept of the root-mean-square deviation, a procedure that has been criticized in literature. Here we propose a special statistical analysis which should be performed separately for the experimental data and for the results of the theoretical computations. In so doing, the random, syst…
▽ More
In most experiments on the Casimir force the comparison between measurement data and theory was done using the concept of the root-mean-square deviation, a procedure that has been criticized in literature. Here we propose a special statistical analysis which should be performed separately for the experimental data and for the results of the theoretical computations. In so doing, the random, systematic, and total experimental errors are found as functions of separation, taking into account the distribution laws for each error at 95% confidence. Independently, all theoretical errors are combined to obtain the total theoretical error at the same confidence. Finally, the confidence interval for the differences between theoretical and experimental values is obtained as a function of separation. This rigorous approach is applied to two recent experiments on the Casimir effect.
△ Less
Submitted 19 December, 2005;
originally announced December 2005.
-
Investigation of the Casimir force between metal and semiconductor test bodies
Authors:
F. Chen,
U. Mohideen,
G. L. Klimchitskaya,
V. M. Mostepanenko
Abstract:
The measurement of the Casimir force between a large gold coated sphere and single crystal silicon plate is performed with an atomic force microscope. A rigorous statistical comparison of data with theory is done, without use of the concept of root-mean-square deviation, and excellent agreement is obtained. The Casimir force between metal and semiconductor is demonstrated to be significantly dif…
▽ More
The measurement of the Casimir force between a large gold coated sphere and single crystal silicon plate is performed with an atomic force microscope. A rigorous statistical comparison of data with theory is done, without use of the concept of root-mean-square deviation, and excellent agreement is obtained. The Casimir force between metal and semiconductor is demonstrated to be significantly different than between two similar or dissimilar metals.
△ Less
Submitted 8 July, 2005; v1 submitted 1 May, 2005;
originally announced May 2005.
-
Precision Measurement of the Casimir Force from 0.1 to 0.9 microns
Authors:
U. Mohideen,
Anushree Roy
Abstract:
We have used an atomic force microscope to make precision measurements of the Casimir force between a metallized sphere of diameter 196 microns and flat plate. The force was measured for plate-sphere separations from 0.1 to 0.9 microns. The experimental results are consistent with present theoretical calculations including the finite conductivity, roughness, and temperature corrections. The root…
▽ More
We have used an atomic force microscope to make precision measurements of the Casimir force between a metallized sphere of diameter 196 microns and flat plate. The force was measured for plate-sphere separations from 0.1 to 0.9 microns. The experimental results are consistent with present theoretical calculations including the finite conductivity, roughness, and temperature corrections. The root mean square average deviation of 1.6 pN between theory and experiment corresponds to a 1% deviation at the smallest separation.
△ Less
Submitted 9 December, 1998; v1 submitted 29 May, 1998;
originally announced May 1998.