-
On-and-off chip cooling of a Coulomb blockade thermometer down to 2.8 mK
Authors:
M. Palma,
C. P. Scheller,
D. Maradan,
A. V. Feshchenko,
M. Meschke,
D. M. Zumbühl
Abstract:
Cooling nanoelectronic devices below 10 mK is a great challenge since thermal conductivities become very small, thus creating a pronounced sensitivity to heat leaks. Here, we overcome these difficulties by using adiabatic demagnetization of \emph{both} the electronic leads \emph{and} the large metallic islands of a Coulomb blockade thermometer. This reduces the external heat leak through the leads…
▽ More
Cooling nanoelectronic devices below 10 mK is a great challenge since thermal conductivities become very small, thus creating a pronounced sensitivity to heat leaks. Here, we overcome these difficulties by using adiabatic demagnetization of \emph{both} the electronic leads \emph{and} the large metallic islands of a Coulomb blockade thermometer. This reduces the external heat leak through the leads and also provides on-chip refrigeration, together cooling the thermometer down to 2.8$\pm$0.1 mK. We present a thermal model which gives a good qualitative account and suggests that the main limitation is heating due to pulse tube vibrations. With better decoupling, temperatures below 1 mK should be within reach, thus opening the door for microkelvin nanoelectronics.
△ Less
Submitted 30 August, 2017;
originally announced August 2017.
-
Magnetic cooling for microkelvin nanoelectronics on a cryofree platform
Authors:
Mario Palma,
Dario Maradan,
Lucas Casparis,
Tai-Min Liu,
Florian Froning,
Dominik M. Zumbühl
Abstract:
We present a parallel network of 16 demagnetization refrigerators mounted on a cryofree dilution refrigerator aimed to cool nanoelectronic devices to sub-millikelvin temperatures. To measure the refrigerator temperature, the thermal motion of electrons in a Ag wire -- thermalized by a spot-weld to one of the Cu nuclear refrigerators -- is inductively picked-up by a superconducting gradiometer and…
▽ More
We present a parallel network of 16 demagnetization refrigerators mounted on a cryofree dilution refrigerator aimed to cool nanoelectronic devices to sub-millikelvin temperatures. To measure the refrigerator temperature, the thermal motion of electrons in a Ag wire -- thermalized by a spot-weld to one of the Cu nuclear refrigerators -- is inductively picked-up by a superconducting gradiometer and amplified by a SQUID mounted at 4 K. The noise thermometer as well as other thermometers are used to characterize the performance of the system, finding magnetic field independent heat-leaks of a few nW/mol, cold times of several days below 1 mK, and a lowest temperature of 150 microK of one of the nuclear stages in a final field of 80 mT, close to the intrinsic SQUID noise of about 100 microK. A simple thermal model of the system capturing the nuclear refrigerator, heat leaks, as well as thermal and Korringa links describes the main features very well, including rather high refrigerator efficiencies typically above 80%.
△ Less
Submitted 21 February, 2017;
originally announced February 2017.
-
Tunnel-Junction Thermometry Down to Millikelvin Temperatures
Authors:
A. V. Feshchenko,
L. Casparis,
I. M. Khaymovich,
D. Maradan,
O. -P. Saira,
M. Palma,
M. Meschke,
J. P. Pekola,
D. M. Zumbühl
Abstract:
We present a simple on-chip electronic thermometer with the potential to operate down to 1 mK. It is based on transport through a single normal-metal - superconductor tunnel junction with rapidly widening leads. The current through the junction is determined by the temperature of the normal electrode that is efficiently thermalized to the phonon bath, and it is virtually insensitive to the tempera…
▽ More
We present a simple on-chip electronic thermometer with the potential to operate down to 1 mK. It is based on transport through a single normal-metal - superconductor tunnel junction with rapidly widening leads. The current through the junction is determined by the temperature of the normal electrode that is efficiently thermalized to the phonon bath, and it is virtually insensitive to the temperature of the superconductor, even when the latter is relatively far from equilibrium. We demonstrate here the operation of the device down to 7 mK and present a systematic thermal analysis.
△ Less
Submitted 28 September, 2015; v1 submitted 15 April, 2015;
originally announced April 2015.
-
GaAs Quantum Dot Thermometry Using Direct Transport and Charge Sensing
Authors:
D. Maradan,
L. Casparis,
T. -M. Liu,
D. E. F. Biesinger,
C. P. Scheller,
D. M. Zumbühl,
J. Zimmerman,
A. C. Gossard
Abstract:
We present measurements of the electron temperature using gate defined quantum dots formed in a GaAs 2D electron gas in both direct transport and charge sensing mode. Decent agreement with the refrigerator temperature was observed over a broad range of temperatures down to 10 mK. Upon cooling nuclear demagnetization stages integrated into the sample wires below 1 mK, the device electron temperatur…
▽ More
We present measurements of the electron temperature using gate defined quantum dots formed in a GaAs 2D electron gas in both direct transport and charge sensing mode. Decent agreement with the refrigerator temperature was observed over a broad range of temperatures down to 10 mK. Upon cooling nuclear demagnetization stages integrated into the sample wires below 1 mK, the device electron temperature saturates, remaining close to 10 mK. The extreme sensitivity of the thermometer to its environment as well as electronic noise complicates temperature measurements but could potentially provide further insight into the device characteristics. We discuss thermal coupling mechanisms, address possible reasons for the temperature saturation and delineate the prospects of further reducing the device electron temperature.
△ Less
Submitted 10 January, 2014;
originally announced January 2014.
-
Metallic Coulomb Blockade Thermometry down to 10 mK and below
Authors:
L. Casparis,
M. Meschke,
D. Maradan,
A. C. Clark,
C. Scheller,
K. K. Schwarzwalder,
J. P. Pekola,
D. M. Zumbuhl
Abstract:
We present an improved nuclear refrigerator reaching 0.3 mK, aimed at microkelvin nanoelectronic experiments, and use it to investigate metallic Coulomb blockade thermometers (CBTs) with various resistances R. The high-R devices cool to slightly lower T, consistent with better isolation from the noise environment, and exhibit electron-phonon cooling ~ T^5 and a residual heat-leak of 40 aW. In cont…
▽ More
We present an improved nuclear refrigerator reaching 0.3 mK, aimed at microkelvin nanoelectronic experiments, and use it to investigate metallic Coulomb blockade thermometers (CBTs) with various resistances R. The high-R devices cool to slightly lower T, consistent with better isolation from the noise environment, and exhibit electron-phonon cooling ~ T^5 and a residual heat-leak of 40 aW. In contrast, the low-R CBTs display cooling with a clearly weaker T-dependence, deviating from the electronphonon mechanism. The CBTs agree excellently with the refrigerator temperature above 20 mK and reach a minimum-T of 7.5 +/- 0.2 mK.
△ Less
Submitted 8 June, 2012; v1 submitted 8 November, 2011;
originally announced November 2011.
-
Method for Cooling Nanostructures to Microkelvin Temperatures
Authors:
A. C. Clark,
K. K. Schwarzwälder,
T. Bandi,
D. Maradan,
D. M. Zumbühl
Abstract:
We propose a new scheme aimed at cooling nanostructures to microkelvin temperatures, based on the well established technique of adiabatic nuclear demagnetization: we attach each device measurement lead to an individual nuclear refrigerator, allowing efficient thermal contact to a microkelvin bath. On a prototype consisting of a parallel network of nuclear refrigerators, temperatures of $\sim 1\,$m…
▽ More
We propose a new scheme aimed at cooling nanostructures to microkelvin temperatures, based on the well established technique of adiabatic nuclear demagnetization: we attach each device measurement lead to an individual nuclear refrigerator, allowing efficient thermal contact to a microkelvin bath. On a prototype consisting of a parallel network of nuclear refrigerators, temperatures of $\sim 1\,$mK simultaneously on ten measurement leads have been reached upon demagnetization, thus completing the first steps toward ultracold nanostructures.
△ Less
Submitted 26 May, 2010;
originally announced May 2010.