-
Purcell-enhanced single-photon emission from nitrogen-vacancy centers coupled to a tunable microcavity
Authors:
Hanno Kaupp,
Thomas Hümmer,
Matthias Mader,
Benedikt Schlederer,
Julia Benedikter,
Philip Haeusser,
Huan-Cheng Chang,
Helmut Fedder,
Theodor W. Hänsch,
David Hunger
Abstract:
Optical microcavities are a powerful tool to enhance spontaneous emission of individual quantum emitters. However, the broad emission spectra encountered in the solid state at room temperature limit the influence of a cavity, and call for ultra-small mode volume. We demonstrate Purcell-enhanced single photon emission from nitrogen-vacancy (NV) centers in nanodiamonds coupled to a tunable fiber-bas…
▽ More
Optical microcavities are a powerful tool to enhance spontaneous emission of individual quantum emitters. However, the broad emission spectra encountered in the solid state at room temperature limit the influence of a cavity, and call for ultra-small mode volume. We demonstrate Purcell-enhanced single photon emission from nitrogen-vacancy (NV) centers in nanodiamonds coupled to a tunable fiber-based microcavity with a mode volume down to $1.0\,λ^{3}$. We record cavity-enhanced fluorescence images and study several single emitters with one cavity. The Purcell effect is evidenced by enhanced fluorescence collection, as well as tunable fluorescence lifetime modification, and we infer an effective Purcell factor of up to 2.0. With numerical simulations, we furthermore show that a novel regime for light confinement can be achieved, where a Fabry-Perot mode is combined with additional mode confinement by the nanocrystal itself. In this regime, effective Purcell factors of up to 11 for NV centers and 63 for silicon vacancy centers are feasible, holding promise for bright single photon sources and efficient spin readout under ambient conditions.
△ Less
Submitted 2 June, 2016; v1 submitted 1 June, 2016;
originally announced June 2016.
-
A Scanning Cavity Microscope
Authors:
Matthias Mader,
Jakob Reichel,
Theodor W. Hänsch,
David Hunger
Abstract:
Imaging of the optical properties of individual nanosystems beyond fluorescence can provide a wealth of information. However, the minute signals for absorption and dispersion are challenging to observe, and only specialized techniques requiring sophisticated noise rejection are available. Here we use signal enhancement in a scanning optical microcavity to demonstrate ultra-sensitive imaging. Harne…
▽ More
Imaging of the optical properties of individual nanosystems beyond fluorescence can provide a wealth of information. However, the minute signals for absorption and dispersion are challenging to observe, and only specialized techniques requiring sophisticated noise rejection are available. Here we use signal enhancement in a scanning optical microcavity to demonstrate ultra-sensitive imaging. Harnessing multiple interactions of probe light with a sample within an optical resonator, we achieve a 1700-fold signal enhancement compared to diffraction-limited microscopy. We demonstrate quantitative imaging of the extinction cross section of gold nanoparticles with a sensitivity below 1 nm2, we show a method to improve spatial resolution potentially below the diffraction limit by using higher order cavity modes, and we present measurements of the birefringence and extinction contrast of gold nanorods. The demonstrated simultaneous enhancement of absorptive and dispersive signals promises intriguing potential for optical studies of nanomaterials, molecules, and biological nanosystems.
△ Less
Submitted 9 September, 2015; v1 submitted 26 November, 2014;
originally announced November 2014.
-
Spectroscopy of mechanical dissipation in micro-mechanical membranes
Authors:
Andreas Jöckel,
Matthew T. Rakher,
Maria Korppi,
Stephan Camerer,
David Hunger,
Matthias Mader,
Philipp Treutlein
Abstract:
We measure the frequency dependence of the mechanical quality factor (Q) of SiN membrane oscillators and observe a resonant variation of Q by more than two orders of magnitude. The frequency of the fundamental mechanical mode is tuned reversibly by up to 40% through local heating with a laser. Several distinct resonances in Q are observed that can be explained by coupling to membrane frame modes.…
▽ More
We measure the frequency dependence of the mechanical quality factor (Q) of SiN membrane oscillators and observe a resonant variation of Q by more than two orders of magnitude. The frequency of the fundamental mechanical mode is tuned reversibly by up to 40% through local heating with a laser. Several distinct resonances in Q are observed that can be explained by coupling to membrane frame modes. Away from the resonances, the background Q is independent of frequency and temperature in the measured range.
△ Less
Submitted 12 August, 2011;
originally announced August 2011.
-
Hydrodynamic lift of vesicles under shear flow in microgravity
Authors:
Natacha Callens,
Christophe Minetti,
Maud-Alix Mader,
Gwennou Coupier,
Frank Dubois,
Chaouqi Misbah,
Thomas Podgorski
Abstract:
The dynamics of a vesicle suspension in a shear flow between parallel plates has been investigated under microgravity conditions, where vesicles are only submitted to hydrodynamic effects such as lift forces due to the presence of walls and drag forces. The temporal evolution of the spatial distribution of the vesicles has been recorded thanks to digital holographic microscopy, during parabolic…
▽ More
The dynamics of a vesicle suspension in a shear flow between parallel plates has been investigated under microgravity conditions, where vesicles are only submitted to hydrodynamic effects such as lift forces due to the presence of walls and drag forces. The temporal evolution of the spatial distribution of the vesicles has been recorded thanks to digital holographic microscopy, during parabolic flights and under normal gravity conditions. The collected data demonstrates that vesicles are pushed away from the walls with a lift velocity proportional to $\dotγ R^3/z^2$ where $\dotγ$ is the shear rate, $R$ the vesicle radius and $z$ its distance from the wall. This scaling as well as the dependence of the lift velocity upon vesicle aspect ratio are consistent with theoretical predictions by Olla [J. Phys. II France {\bf 7}, 1533--1540 (1997)].
△ Less
Submitted 9 April, 2008; v1 submitted 4 April, 2008;
originally announced April 2008.
-
Rheology of dilute suspensions of vesicles and red blood cells
Authors:
Victoria Vitkova,
Maud-Alix Mader,
Chaouqi Misbah,
Thomas Podgorski
Abstract:
We present rheology experiments on dilute solutions of vesicles and red blood cells (RBC). Varying the viscosity ratio $λ$ between internal and external fluids, the microscopic dynamics of suspended objects can be qualitatively changed from tank-treading ($tt$) to tumbling ($tb$). We find that in the tt regime the viscosity $η$, decreases when $λ$ increases, in contrast with droplet emulsions an…
▽ More
We present rheology experiments on dilute solutions of vesicles and red blood cells (RBC). Varying the viscosity ratio $λ$ between internal and external fluids, the microscopic dynamics of suspended objects can be qualitatively changed from tank-treading ($tt$) to tumbling ($tb$). We find that in the tt regime the viscosity $η$, decreases when $λ$ increases, in contrast with droplet emulsions and elastic capsule theories which are sometimes invoked to model RBC dynamics. At a critical $λ$ (close to the tt-tb transition) $η$ exhibits a minimum before it increases in the tb regime. This is consistent with a recent theory for vesicles. This points to the nontrivial fact that the cytoskeleton in RBC does not alter the qualitative evolution of $η$ and that, as far as rheology is concerned, vesicle models might be a better description.
△ Less
Submitted 29 July, 2007;
originally announced July 2007.