-
Recovering the second moment of the strain distribution from neutron Bragg edge data
Authors:
Kyle Fogarty,
Evelina Ametova,
Genoveva Burca,
Alexander M. Korsunsky,
Søren Schmidt,
Philip J. Withers,
William R. B. Lionheart
Abstract:
Point by point strain scanning is often used to map the residual stress (strain) in engineering materials and components. However, the gauge volume and hence spatial resolution is limited by the beam defining apertures and can be anisotropic for very low and high diffraction (scattering) angles. Alternatively, wavelength resolved neutron transmission imaging has a potential to retrieve information…
▽ More
Point by point strain scanning is often used to map the residual stress (strain) in engineering materials and components. However, the gauge volume and hence spatial resolution is limited by the beam defining apertures and can be anisotropic for very low and high diffraction (scattering) angles. Alternatively, wavelength resolved neutron transmission imaging has a potential to retrieve information tomographically about residual strain induced within materials through measurement in transmission of Bragg edges - crystallographic fingerprints whose locations and shapes depend on microstructure and strain distribution. In such a case the spatial resolution is determined by the geometrical blurring of the measurement setup and the detector point spread function. Mathematically, reconstruction of strain tensor field is described by the longitudinal ray transform; this transform has a non-trivial null-space, making direct inversion impossible. A combination of the longitudinal ray transform with physical constraints was used to reconstruct strain tensor fields in convex objects. To relax physical constraints and generalise reconstruction, a recently introduced concept of histogram tomography can be employed. Histogram tomography relies on our ability to resolve the distribution of strain in the beam direction, as we discuss in the paper. More specifically, Bragg edge strain tomography requires extraction of the second moment (variance about zero) of the strain distribution which has not yet been demonstrated in practice. In this paper we verify experimentally that the second moment can be reliably measured for a previously well characterised aluminium ring and plug sample. We compare experimental measurements against numerical calculation and further support our conclusions by rigorous uncertainty quantification of the estimated mean and variance of the strain distribution.
△ Less
Submitted 29 March, 2022; v1 submitted 17 January, 2022;
originally announced January 2022.
-
Scanning electron diffraction tomography of strain
Authors:
Robert Tovey,
Duncan N. Johnstone,
Sean M. Collins,
William R. B. Lionheart,
Paul A. Midgley,
Martin Benning,
Carola-Bibiane Schönlieb
Abstract:
Strain engineering is used to obtain desirable materials properties in a range of modern technologies. Direct nanoscale measurement of the three-dimensional strain tensor field within these materials has however been limited by a lack of suitable experimental techniques and data analysis tools. Scanning electron diffraction has emerged as a powerful tool for obtaining two-dimensional maps of strai…
▽ More
Strain engineering is used to obtain desirable materials properties in a range of modern technologies. Direct nanoscale measurement of the three-dimensional strain tensor field within these materials has however been limited by a lack of suitable experimental techniques and data analysis tools. Scanning electron diffraction has emerged as a powerful tool for obtaining two-dimensional maps of strain components perpendicular to the incident electron beam direction. Extension of this method to recover the full three-dimensional strain tensor field has been restricted though by the absence of a formal framework for tensor tomography using such data. Here, we show that it is possible to reconstruct the full non-symmetric strain tensor field as the solution to an ill-posed tensor tomography inverse problem. We then demonstrate the properties of this tomography problem both analytically and computationally, highlighting why incorporating precession to perform scanning precession electron diffraction may be important. We establish a general framework for non-symmetric tensor tomography and demonstrate computationally its applicability for achieving strain tomography with scanning precession electron diffraction data.
△ Less
Submitted 10 November, 2020; v1 submitted 3 August, 2020;
originally announced August 2020.
-
Three Dimensional Polarimetric Neutron Tomography of Magnetic Fields
Authors:
Morten Sales,
Markus Strobl,
Takenao Shinohara,
Anton Tremsin,
Luise Theil Kuhn,
William R. B. Lionheart,
Naeem M. Desai,
Anders Bjorholm Dahl,
Søren Schmidt
Abstract:
Through the use of Time-of-Flight Three Dimensional Polarimetric Neutron Tomography (ToF 3DPNT) we have for the first time successfully demonstrated a technique capable of measuring and reconstructing three dimensional magnetic field strengths and directions unobtrusively and non-destructively with the potential to probe the interior of bulk samples which is not amenable otherwise.
Using a pione…
▽ More
Through the use of Time-of-Flight Three Dimensional Polarimetric Neutron Tomography (ToF 3DPNT) we have for the first time successfully demonstrated a technique capable of measuring and reconstructing three dimensional magnetic field strengths and directions unobtrusively and non-destructively with the potential to probe the interior of bulk samples which is not amenable otherwise.
Using a pioneering polarimetric set-up for ToF neutron instrumentation in combination with a newly developed tailored reconstruction algorithm, the magnetic field generated by a current carrying solenoid has been measured and reconstructed, thereby providing the proof-of-principle of a technique able to reveal hitherto unobtainable information on the magnetic fields in the bulk of materials and devices, due to a high degree of penetration into many materials, including metals, and the sensitivity of neutron polarisation to magnetic fields. The technique puts the potential of the ToF time structure of pulsed neutron sources to full use in order to optimise the recorded information quality and reduce measurement time.
△ Less
Submitted 2 February, 2018; v1 submitted 17 April, 2017;
originally announced April 2017.
-
Reconstruction of spatially inhomogeneous dielectric tensors via optical tomography
Authors:
Hanno Hammer,
William R. B. Lionheart
Abstract:
A method to reconstruct weakly anisotropic inhomogeneous dielectric tensors inside a transparent medium is proposed. The mathematical theory of Integral Geometry is cast into a workable framework which allows the full determination of dielectric tensor fields by scalar Radon inversions of the polarization transformation data obtained from six planar tomographic scanning cycles. Furthermore, a ca…
▽ More
A method to reconstruct weakly anisotropic inhomogeneous dielectric tensors inside a transparent medium is proposed. The mathematical theory of Integral Geometry is cast into a workable framework which allows the full determination of dielectric tensor fields by scalar Radon inversions of the polarization transformation data obtained from six planar tomographic scanning cycles. Furthermore, a careful derivation of the usual equations of integrated photoelasticity in terms of heuristic length scales of the material inhomogeneity and anisotropy is provided, making the paper a self-contained account about the reconstruction of arbitrary three-dimensional, weakly anisotropic dielectric tensor fields.
△ Less
Submitted 29 June, 2004; v1 submitted 11 June, 2004;
originally announced June 2004.