-
arXiv:1301.7025 [pdf, ps, other]
Casimir probe based upon metallized high Q SiN nanomembrane resonator
Abstract: We present the instrumentation and measurement scheme of a new Casimir force probe that bridges Casimir force measurements at microscale and macroscale. A metallized high Q silicon nitride nanomembrane resonator is employed as a sensitive force probe. The high tensile stress present in the nanomembrane not only enhances the quality factor but also maintains high flatness over large area serving as… ▽ More
Submitted 29 January, 2013; originally announced January 2013.
Journal ref: Rev. Sci. Instrum. 84, 015115 (2013)
-
arXiv:1207.4429 [pdf, ps, other]
Casimir Force and In Situ Surface Potential Measurements on Nanomembranes
Abstract: We present Casimir force measurements in a sphere-plate configuration that consists of a high quality nanomembrane resonator and a millimeter sized gold coated sphere. The nanomembrane is fabricated from stoichiometric silicon nitride metallized with gold. A Kelvin probe method is used in situ to image the surface potentials to minimize the distance-dependent residual force. Resonance-enhanced fre… ▽ More
Submitted 18 July, 2012; originally announced July 2012.
Journal ref: Phys. Rev. Lett. 109, 027202 (2012)
-
arXiv:1104.4391 [pdf, ps, other]
New Experimental Limit on the Electric Dipole Moment of the Electron in a Paramagnetic Insulator
Abstract: We report results of an experimental search for the intrinsic Electric Dipole Moment (EDM) of the electron using a solid-state technique. The experiment employs a paramagnetic, insulating gadolinium gallium garnet (GGG) that has a large magnetic response at low temperatures. The presence of the eEDM would lead to a small but non-zero magnetization as the GGG sample is subject to a strong electric… ▽ More
Submitted 1 June, 2015; v1 submitted 22 April, 2011; originally announced April 2011.
Comments: 9 pages, 9 figures, Revtex 4.1
Journal ref: Phys. Rev. D 91 102004 (2015)
-
arXiv:1008.3640 [pdf, ps, other]
Progress in Experimental Measurements of the Surface-Surface Casimir Force: Electrostatic Calibrations and Limitations to Accuracy
Abstract: Several new experiments have extended studies of the Casimir force into new and interesting regimes. This recent work will be briefly reviewed. With this recent progress, new issues with background electrostatic effects have been uncovered. The myriad of problems associated with both patch potentials and electrostatic calibrations are discussed and the remaining open questions are brought forward.
Submitted 21 August, 2010; originally announced August 2010.
Comments: three figures. Chapter contribution to a Springer Lecture Notes volume "Casimir Physics"
-
arXiv:1007.4276 [pdf, ps, other]
Systematic Correction for "Demonstration of the Casimir Force in the 0.6 to 6 micrometer Range"
Abstract: A new systematic correction for Casimir force measurements is proposed and applied to the results of an experiment that was performed more than a decade ago. This correction brings the experimental results into good agreement with the Drude model of the metallic plates' permittivity. The systematic is due to time-dependent fluctuations in the distance between the plates caused by mechanical vibrat… ▽ More
Submitted 24 July, 2010; originally announced July 2010.
Comments: 8 pages, one figure
-
First-principles design and subsequent synthesis of a material to search for the permanent electric dipole moment of the electron
Abstract: We describe the first-principles design and subsequent synthesis of a new material with the specific functionalities required for a solid-state-based search for the permanent electric dipole moment of the electron. We show computationally that perovskite-structure europium barium titanate should exhibit the required large and pressure-dependent ferroelectric polarization, local magnetic moments, a… ▽ More
Submitted 18 June, 2010; v1 submitted 1 February, 2010; originally announced February 2010.
Comments: Nature Materials, in press
Journal ref: NATURE MATERIALS 9, 649 (2010)
-
arXiv:0810.2770 [pdf, ps, other]
Magnetic susceptibility and magnetization fluctuation measurements of mixed Gadolinium-Yttrium Iron Garnets
Abstract: We study the magnetic properties of Gadolinium-Yttrium Iron Garnet ($\text{Gd}_{x}\text{Y}_{3-x}\text{Fe}_5\text{0}_{12}$, $x=3,1.8$) ferrite ceramics. The complex initial permeability is measured in the temperature range 2 K to 295 K at frequency of 1 kHz, and in the frequency range 100 Hz to 200 MHz at temperatures 4 K, 77 K, and 295 K. The magnetic viscosity-induced imaginary part of the perm… ▽ More
Submitted 15 October, 2008; originally announced October 2008.
-
arXiv:0808.4000 [pdf, ps, other]
Precision and Casimir Force Measurements in Superfluid and Vacuum with Silicon Nitride Membranes
Abstract: The recent discovery that silicon nitride membranes can be used as extremely high Q mechanical resonators makes possible a number of novel experiments, which include improved long range vacuum Casimir force measurements, and measurments of the properties of liquid helium below the lambda point. It is noted that in the thermal correction to the Casimir force, the phase velocity of the excitations… ▽ More
Submitted 28 August, 2008; originally announced August 2008.
Comments: six pages, no figures
-
arXiv:0804.1506 [pdf, ps, other]
Comment on ``Measurement of the $^3$He mass diffusion coefficient in superfluid $^4$He over the 0.45--0.95 K temperature range
Abstract: The role of 3He-3He collisions in our diffusion experiment is addressed and shown to not be relevant to the measurement of 3He diffusion against phonons in superfluid helium.
Submitted 9 April, 2008; originally announced April 2008.
Comments: Two pages, in Europhysics Letters format
-
Gadolinium Iron Garnet as a Solid State Material for an Electron Electric Dipole Moment Search
Abstract: The possibility of a solid state electron electric dipole moment (EDM) experiment based on Gadolinium Iron Garnet (GdIG) is investigated. GdIG appears to exhibit superparamagnetism and this effect can be used to enhance the electric-field-induced EDM signal at relatively a high temperatures, as compared to a simple paramagnetic system such as Gadolinium Gallium Garnet. The sensitivity of a GdIG… ▽ More
Submitted 16 March, 2007; v1 submitted 17 January, 2007; originally announced January 2007.
Comments: this isn't high energy experiment. 15 pages, three figures
-
On the sensitivity of condensed-matter P- and T-violation experiments
Abstract: Experiments searching for parity- and time-reversal-invariance-violating effects that rely on measuring magnetization of a condensed-matter sample induced by application of an electric field are considered. A limit on statistical sensitivity arises due to random fluctuations of the spins in the sample. The scaling of this limit with the number of spins and their relaxation time is derived. Appli… ▽ More
Submitted 7 November, 2005; v1 submitted 7 November, 2005; originally announced November 2005.
Comments: 6 pages, no figures
-
Measurement of the electron electric dipole moment using GdIG
Abstract: A new method for the detection of the electron edm using a solid is described. The method involves the measurement of a voltage induced across the solid by the alignment of the samples magnetic dipoles in an applied magnetic field, H. A first application of the method to GdIG has resulted in a limit on the electron edm of 5E-24 e-cm, which is a factor of 40 below the limit obtained from the only… ▽ More
Submitted 27 October, 2005; v1 submitted 13 September, 2005; originally announced September 2005.
Comments: 10 pages, 5 figures, v2:references corrected, submitted to PRL, v3:added labels to figure 1
Report number: AC-09-13
Journal ref: Phys.Rev.Lett. 95 (2005) 253004
-
Measurement of the 3He mass diffusion coefficient in superfluid 4He over the 0.45-0.95 K temperature range
Abstract: We have measured the mass diffusion coefficient D of 3He in superfluid 4He at temperatures lower than were previously possible. The experimental technique utilizes scintillation light produced when neutron react with 3He nuclei, and allows measurement of the 3He density integrated along the trajectory of a well-defined neutron beam. By measuring the change in 3He density near a heater as a funct… ▽ More
Submitted 4 October, 2001; originally announced October 2001.
Comments: 8 pages, 5 figures. Submitted to Europhysics Letters and prepared in that journal's format
Report number: LA-UR 01-5444
-
Magnetically Stabilized Luminescent Excitations in Hexagonal Boron Nitride
Abstract: Magnetically stabilized luminescence is observed in hexagonal boron nitride. The luminescence is induced by absorption of cold neutrons and is in the visible region. In the absence of a magnetic field, the photon emission level is observed to decay over several hundred seconds. A fraction of this luminescence can be suppressed if the temperature is T <~ 0.6 K and the magnetic field is B >~ 1.0 T… ▽ More
Submitted 13 March, 2001; originally announced March 2001.
Comments: 11 pages, 7 figures, to appear in the Journal of Luminescence