-
In-situ electro-optic sampling of microwave signals under cryogenic conditions and for superconducting applications
Authors:
Shekhar Priyadarshi,
Oliver Kieler,
Alexander Fernandez Scarioni,
Judith Felgner,
Abdulrahman Widaa,
Johannes Kohlmann,
Thomas Fordell,
Jaani Nissilä,
Antti Kemppinen,
Mark Bieler
Abstract:
We demonstrate a cryogenic electro-optic sampling (EOS) setup that allows for the measurement of microwave signals at arbitrary positions on a cryogenic chip-scale device. We use a Josephson Arbitrary Waveform Synthesizer (JAWS) to generate quantum-accurate voltage signals and measure them with the EOS setup, allowing for the calibration of its response, yielding traceability of the microwave meas…
▽ More
We demonstrate a cryogenic electro-optic sampling (EOS) setup that allows for the measurement of microwave signals at arbitrary positions on a cryogenic chip-scale device. We use a Josephson Arbitrary Waveform Synthesizer (JAWS) to generate quantum-accurate voltage signals and measure them with the EOS setup, allowing for the calibration of its response, yielding traceability of the microwave measurements to a quantum standard. We use the EOS setup to determine the time-domain response of ultrafast cryogenic photodiodes and the electrical reflection coefficient, i.e., the S11 scattering parameter, in a superconducting transmission line. Finally, we introduce an optical femtosecond pulse source which can be used to study the fidelity of superconducting transmission lines and terminations, as well as reflections from elements like Josephson junction arrays imbedded in them.
△ Less
Submitted 31 October, 2024;
originally announced November 2024.
-
Cascade switching current detectors based on arrays of Josephson junctions
Authors:
Roger Cattaneo,
Artemii E. Efimov,
Kirill I. Shiianov,
Oliver Kieler,
Vladimir M. Krasnov
Abstract:
Cascade multiplication is a common technique to enhance the sensitivity of photon detectors. In this study, we demonstrate novel cascade-amplified superconducting detectors utilizing arrays of Josephson junctions. The mutual coupling between junctions induces avalanche-like switching of multiple junctions upon photon absorption, leading to cascade amplification of the readout voltage. We present t…
▽ More
Cascade multiplication is a common technique to enhance the sensitivity of photon detectors. In this study, we demonstrate novel cascade-amplified superconducting detectors utilizing arrays of Josephson junctions. The mutual coupling between junctions induces avalanche-like switching of multiple junctions upon photon absorption, leading to cascade amplification of the readout voltage. We present two prototypes featuring either low-Tc linear Nb/NbxSi1-x/Nb arrays, or high-Tc stacked intrinsic Josephson junctions. Both devices exhibit clear antenna effects in microwave directivities, indicating good impedance matching and absorption efficiency. The combination of high absorption efficiency and large cascade amplification has the potential to produce broadband THz sensors with sensitivity exceeding 10^13 V/W.
△ Less
Submitted 30 January, 2025; v1 submitted 24 September, 2024;
originally announced September 2024.
-
Combining Electron Spin Resonance Spectroscopy with Scanning Tunneling Microscopy at High Magnetic Fields
Authors:
Robert Drost,
Maximilian Uhl,
Piotr Kot,
Janis Siebrecht,
Alexander Schmid,
Jonas Merkt,
Stefan Wünsch,
Michael Siegel,
Oliver Kieler,
Reinhold Kleiner,
Christian R. Ast
Abstract:
Magnetic media remain a key in information storage and processing. The continuous increase of storage densities and the desire for quantum memories and computers pushes the limits of magnetic characterisation techniques. Ultimately, a tool which is capable of coherently manipulating and detecting individual quantum spins is needed. The scanning tunnelling microscope (STM) is the only technique whi…
▽ More
Magnetic media remain a key in information storage and processing. The continuous increase of storage densities and the desire for quantum memories and computers pushes the limits of magnetic characterisation techniques. Ultimately, a tool which is capable of coherently manipulating and detecting individual quantum spins is needed. The scanning tunnelling microscope (STM) is the only technique which unites the prerequisites of high spatial and energy resolution, low temperature and high magnetic fields to achieve this goal. Limitations in the available frequency range for electron spin resonance STM (ESR-STM) mean that many instruments operate in the thermal noise regime. We resolve challenges in signal delivery to extend the operational frequency range of ESR-STM by more than a factor of two and up to 100GHz, making the Zeeman energy the dominant energy scale at achievable cryogenic temperatures of a few hundred millikelvin. We present a general method for augmenting existing instruments into ESR-STMs to investigate spin dynamics in the high-field limit. We demonstrate the performance of the instrument by analysing inelastic tunnelling in a junction driven by a microwave signal and provide proof of principle measurements for ESR-STM.
△ Less
Submitted 10 November, 2021;
originally announced November 2021.
-
Driving a low critical current Josephson junction array with a mode-locked laser
Authors:
J. Nissila,
T. Fordell,
K. Kohopaa,
E. Mykkanen,
P. Immonen,
R. N. Jabradaghi,
E. Bardalen,
O. Kieler,
B. Karlsen,
P. A. Ohlckers,
R. Behr,
A. J. Manninen,
J. Govenius,
A. Kemppinen
Abstract:
We demonstrate the operation of Josephson junction arrays (JJA) driven by optical pulses generated by a mode-locked laser and an optical time-division multiplexer. A commercial photodiode converts the optical pulses into electrical ones in liquid helium several cm from the JJA. The performance of our custom-made mode-locked laser is sufficient for driving a JJA with low critical current at multipl…
▽ More
We demonstrate the operation of Josephson junction arrays (JJA) driven by optical pulses generated by a mode-locked laser and an optical time-division multiplexer. A commercial photodiode converts the optical pulses into electrical ones in liquid helium several cm from the JJA. The performance of our custom-made mode-locked laser is sufficient for driving a JJA with low critical current at multiple Shapiro steps. Our optical approach is a potential enabler for fast and energy-efficient pulse drive without expensive high-bandwidth electrical pulse pattern generator, and without high-bandwidth electrical cabling crossing temperature stages. Our measurements and simulations motivate an improved integration of photodiodes and JJAs using, e.g., flip-chip techniques, in order to improve both the understanding and fidelity of pulse-driven Josephson Arbitrary Waveform Synthesizers (JAWS).
△ Less
Submitted 25 September, 2020;
originally announced September 2020.
-
Three-Axis Vector Nano Superconducting Quantum Interference Device
Authors:
M. J. Martínez-Pérez,
D. Gella,
B. Müller,
V. Morosh,
R. Wöbling,
J. Sesé,
O. Kieler,
R. Kleiner,
D. Koelle
Abstract:
We present the design, realization and performance of a three-axis vector nano Superconducting QUantum Interference Device (nanoSQUID). It consists of three mutually orthogonal SQUID nanoloops that allow distinguishing the three components of the vector magnetic moment of individual nanoparticles placed at a specific position. The device is based on Nb/HfTi/Nb Josephson junctions and exhibits line…
▽ More
We present the design, realization and performance of a three-axis vector nano Superconducting QUantum Interference Device (nanoSQUID). It consists of three mutually orthogonal SQUID nanoloops that allow distinguishing the three components of the vector magnetic moment of individual nanoparticles placed at a specific position. The device is based on Nb/HfTi/Nb Josephson junctions and exhibits linewidths of $\sim 250$ nm and inner loop areas of $600 \times 90$ nm$^2$ and $500 \times 500$ nm$^2$. Operation at temperature $T=4.2$ K, under external magnetic fields up to $\sim 50$ mT is demonstrated. The experimental flux noise below $\sim 250$ ${\rm n}Φ_0/\sqrt{\rm Hz}$ in the white noise limit and the reduced dimensions lead to a total calculated spin sensitivity of $\sim 630$ $μ_{\rm B}/\sqrt{\rm Hz}$ and $\sim 70$ $μ_{\rm B}/\sqrt{\rm Hz}$ for the in-plane and out-of-plane components of the vector magnetic moment, respectively. The potential of the device for studying tridimensional properties of individual nanomagnets is discussed.
△ Less
Submitted 23 June, 2016; v1 submitted 25 April, 2016;
originally announced April 2016.
-
Magnetization reversal of an individual exchange biased permalloy nanotube
Authors:
A. Buchter,
R. Wölbing,
M. Wyss,
O. F. Kieler,
T. Weimann,
J. Kohlmann,
A. B. Zorin,
D. Rüffer,
F. Matteini,
G. Tütüncüoglu,
F. Heimbach,
A. Kleibert,
A. Fontcuberta i Morral,
D. Grundler,
R. Kleiner,
D. Koelle,
M. Poggio
Abstract:
We investigate the magnetization reversal mechanism in an individual permalloy (Py) nanotube (NT) using a hybrid magnetometer consisting of a nanometer-scale SQUID (nanoSQUID) and a cantilever torque sensor. The Py NT is affixed to the tip of a Si cantilever and positioned in order to optimally couple its stray flux into a Nb nanoSQUID. We are thus able to measure both the NT's volume magnetizatio…
▽ More
We investigate the magnetization reversal mechanism in an individual permalloy (Py) nanotube (NT) using a hybrid magnetometer consisting of a nanometer-scale SQUID (nanoSQUID) and a cantilever torque sensor. The Py NT is affixed to the tip of a Si cantilever and positioned in order to optimally couple its stray flux into a Nb nanoSQUID. We are thus able to measure both the NT's volume magnetization by dynamic cantilever magnetometry and its stray flux using the nanoSQUID. We observe a training effect and temperature dependence in the magnetic hysteresis, suggesting an exchange bias. We find a low blocking temperature $T_B = 18 \pm 2$ K, indicating the presence of a thin antiferromagnetic native oxide, as confirmed by X-ray absorption spectroscopy on similar samples. Furthermore, we measure changes in the shape of the magnetic hysteresis as a function of temperature and increased training. These observations show that the presence of a thin exchange-coupled native oxide modifies the magnetization reversal process at low temperatures. Complementary information obtained via cantilever and nanoSQUID magnetometry allows us to conclude that, in the absence of exchange coupling, this reversal process is nucleated at the NT's ends and propagates along its length as predicted by theory.
△ Less
Submitted 1 December, 2015;
originally announced December 2015.
-
Reversal mechanism of an individual Ni nanotube simultaneously studied by torque and SQUID magnetometry
Authors:
A. Buchter,
J. Nagel,
D. Rüffer,
F. Xue,
D. P. Weber,
O. F. Kieler,
T. Weimann,
J. Kohlmann,
A. B. Zorin,
E. Russo-Averchi,
R. Huber,
P. Berberich,
A. Fontcuberta i Morral,
M. Kemmler,
R. Kleiner,
D. Koelle,
D. Grundler,
M. Poggio
Abstract:
Using an optimally coupled nanometer-scale superconducting quantum interference device, we measure the magnetic flux originating from an individual ferromagnetic Ni nanotube attached to a Si cantilever. At the same time, we detect the nanotube's volume magnetization using torque magnetometry. We observe both the predicted reversible and irreversible reversal processes. A detailed comparison with m…
▽ More
Using an optimally coupled nanometer-scale superconducting quantum interference device, we measure the magnetic flux originating from an individual ferromagnetic Ni nanotube attached to a Si cantilever. At the same time, we detect the nanotube's volume magnetization using torque magnetometry. We observe both the predicted reversible and irreversible reversal processes. A detailed comparison with micromagnetic simulations suggests that vortex-like states are formed in different segments of the individual nanotube. Such stray-field free states are interesting for memory applications and non-invasive sensing.
△ Less
Submitted 18 July, 2013; v1 submitted 28 May, 2013;
originally announced May 2013.
-
Nanoscale multifunctional sensor formed by a Ni nanotube and a scanning Nb nanoSQUID
Authors:
J. Nagel,
A. Buchter,
F. Xue,
O. F. Kieler,
T. Weimann,
J. Kohlmann,
A. B. Zorin,
D. Rüffer,
E. Russo-Averchi,
R. Huber,
P. Berberich,
A. Fontcuberta i Morral,
D. Grundler,
R. Kleiner,
D. Koelle,
M. Poggio,
M. Kemmler
Abstract:
Nanoscale magnets might form the building blocks of next generation memories. To explore their functionality, magnetic sensing at the nanoscale is key. We present a multifunctional combination of a scanning nanometer-sized superconducting quantum interference device (nanoSQUID) and a Ni nanotube attached to an ultrasoft cantilever as a magnetic tip. We map out and analyze the magnetic coupling bet…
▽ More
Nanoscale magnets might form the building blocks of next generation memories. To explore their functionality, magnetic sensing at the nanoscale is key. We present a multifunctional combination of a scanning nanometer-sized superconducting quantum interference device (nanoSQUID) and a Ni nanotube attached to an ultrasoft cantilever as a magnetic tip. We map out and analyze the magnetic coupling between the Ni tube and the Nb nanoSQUID, demonstrate imaging of an Abrikosov vortex trapped in the SQUID structure - which is important in ruling out spurious magnetic signals - and reveal the high potential of the nanoSQUID as an ultrasensitive displacement detector. Our results open a new avenue for fundamental studies of nanoscale magnetism and superconductivity.
△ Less
Submitted 6 May, 2013;
originally announced May 2013.
-
Nb nano superconducting quantum interference devices with high spin sensitivity for operation in magnetic fields up to 0.5\,T
Authors:
Roman Wölbing,
Joachim Nagel,
Tobias Schwarz,
Oliver Kieler,
Thomas Weimann,
Johannes Kohlmann,
Alexander Zorin,
Matthias Kemmler,
Reinhold Kleiner,
Dieter Koelle
Abstract:
We investigate electric transport and noise properties of microstrip-type submicron direct current superconducting quantum interference devices (dc SQUIDs) based on Nb thin films and overdamped Josephson junctions with a HfTi barrier. The SQUIDs were designed for optimal spin sensitivity $S_μ^{1/2}$ upon operation in intermediate magnetic fields $B$ (tens of mT), applied perpendicular to the subst…
▽ More
We investigate electric transport and noise properties of microstrip-type submicron direct current superconducting quantum interference devices (dc SQUIDs) based on Nb thin films and overdamped Josephson junctions with a HfTi barrier. The SQUIDs were designed for optimal spin sensitivity $S_μ^{1/2}$ upon operation in intermediate magnetic fields $B$ (tens of mT), applied perpendicular to the substrate plane. Our so far best SQUID can be continuously operated in fields up to $B\approx\pm50\,\rm{mT}$ with rms flux noise $S_{Φ,\rm w}^{1/2}\leq250\,\rm{nΦ_0/Hz^{1/2}}$ in the white noise regime and spin sensitivity $S_μ^{1/2}\leq29\,\rm{μ_B/Hz^{1/2}}$. Furthermore, we demonstrate operation in $B=0.5\,\rm{T}$ with high sensitivity in flux $S_{Φ,\rm w}^{1/2}\approx680\,\rm{nΦ_0/Hz^{1/2}}$ and in electron spin $S_μ^{1/2}\approx79\,\rm{μ_B/Hz^{1/2}}$. We discuss strategies to further improve the nanoSQUID performance.
△ Less
Submitted 29 April, 2013;
originally announced April 2013.
-
Superconducting quantum interference devices with submicron Nb/HfTi/Nb junctions for investigation of small magnetic particles
Authors:
J. Nagel,
O. F. Kieler,
T. Weimann,
R. Wölbing,
J. Kohlmann,
A. B. Zorin,
R. Kleiner,
D. Koelle,
M. Kemmler
Abstract:
We investigated, at temperature $4.2\,\mathrm{K}$, electric transport, flux noise and resulting spin sensitivity of miniaturized Nb direct current superconducting quantum interference devices (SQUIDs) based on submicron Josephson junctions with HfTi barriers. The SQUIDs are either of the magnetometer-type or gradiometric in layout. In the white noise regime, for the best magnetometer we obtain a f…
▽ More
We investigated, at temperature $4.2\,\mathrm{K}$, electric transport, flux noise and resulting spin sensitivity of miniaturized Nb direct current superconducting quantum interference devices (SQUIDs) based on submicron Josephson junctions with HfTi barriers. The SQUIDs are either of the magnetometer-type or gradiometric in layout. In the white noise regime, for the best magnetometer we obtain a flux noise $S_Φ^{1/2}=250\,\mathrm{n}Φ_0/\mathrm{Hz}^{1/2}$, corresponding to a spin sensitivity $S^{1/2}_μ\,\ge\,29\,μ_B/\mathrm{Hz}^{1/2}$. For the gradiometer we find $S_Φ^{1/2}=300\,\mathrm{n}Φ_0/\mathrm{Hz}^{1/2}$ and $S^{1/2}_μ\,\ge\,44\,μ_B/\mathrm{Hz}^{1/2}$. The devices can still be optimized with respect to flux noise and coupling between a magnetic particle and the SQUID, leaving room for further improvement towards single spin resolution.
△ Less
Submitted 10 June, 2011;
originally announced June 2011.