-
A Spread-Spectrum SQUID Multiplexer
Authors:
K. D. Irwin,
S. Chaudhuri,
H. -M. Cho,
C. Dawson,
S. Kuenstner,
D. Li,
C. J. Titus,
B. A. Young
Abstract:
The Transition-Edge Sensors (TES) is a mature, high-resolution x-ray spectrometer technology that provides a much higher efficiency than dispersive spectrometers such as gratings and crystal spectrometers. As larger arrays are developed, time-division multiplexing schemes operating at MHz frequencies are being replaced by microwave SQUID multiplexers using frequency-division multiplexing at GHz fr…
▽ More
The Transition-Edge Sensors (TES) is a mature, high-resolution x-ray spectrometer technology that provides a much higher efficiency than dispersive spectrometers such as gratings and crystal spectrometers. As larger arrays are developed, time-division multiplexing schemes operating at MHz frequencies are being replaced by microwave SQUID multiplexers using frequency-division multiplexing at GHz frequencies. However, the multiplexing factor achievable with microwave SQUIDs is limited by the high slew rate on the leading edge of x-ray pulses. In this paper, we propose a new multiplexing scheme for high-slew-rate TES x-ray calorimeters: the spread-spectrum SQUID multiplexer, which has the potential to enable higher multiplexing factors, especially in applications with lower photon arrival rates.
△ Less
Submitted 7 June, 2018;
originally announced June 2018.
-
High quality factor manganese-doped aluminum lumped-element kinetic inductance detectors sensitive to frequencies below 100 GHz
Authors:
G. Jones,
B. R. Johnson,
M. H. Abitbol,
P. A. R. Ade,
S. Bryan,
H. -M. Cho,
P. Day,
D. Flanigan,
K. D. Irwin,
D. Li,
P. Mauskopf,
H. McCarrick,
A. Miller,
Y. R. Song,
C. Tucker
Abstract:
Aluminum lumped-element kinetic inductance detectors (LEKIDs) sensitive to millimeter-wave photons have been shown to exhibit high quality factors, making them highly sensitive and multiplexable. The superconducting gap of aluminum limits aluminum LEKIDs to photon frequencies above 100 GHz. Manganese-doped aluminum (Al-Mn) has a tunable critical temperature and could therefore be an attractive mat…
▽ More
Aluminum lumped-element kinetic inductance detectors (LEKIDs) sensitive to millimeter-wave photons have been shown to exhibit high quality factors, making them highly sensitive and multiplexable. The superconducting gap of aluminum limits aluminum LEKIDs to photon frequencies above 100 GHz. Manganese-doped aluminum (Al-Mn) has a tunable critical temperature and could therefore be an attractive material for LEKIDs sensitive to frequencies below 100 GHz if the internal quality factor remains sufficiently high when manganese is added to the film. To investigate, we measured some of the key properties of Al-Mn LEKIDs. A prototype eight-element LEKID array was fabricated using a 40 nm thick film of Al-Mn deposited on a 500 μm thick high-resistivity, float-zone silicon substrate. The manganese content was 900 ppm, the measured $T_c = 694\pm1$ mK, and the resonance frequencies were near 150 MHz. Using measurements of the forward scattering parameter $S_{21}$ at various bath temperatures between 65 and 250 mK, we determined that the Al-Mn LEKIDs we fabricated have internal quality factors greater than $2 \times 10^5$, which is high enough for millimeter-wave astrophysical observations. In the dark conditions under which these devices were measured, the fractional frequency noise spectrum shows a shallow slope that depends on bath temperature and probe tone amplitude, which could be two-level system noise. The anticipated white photon noise should dominate this level of low-frequency noise when the detectors are illuminated with millimeter-waves in future measurements. The LEKIDs responded to light pulses from a 1550 nm light-emitting diode, and we used these light pulses to determine that the quasiparticle lifetime is 60 μs.
△ Less
Submitted 15 April, 2017; v1 submitted 29 January, 2017;
originally announced January 2017.
-
Photon-noise limited sensitivity in titanium nitride kinetic inductance detectors
Authors:
Johannes Hubmayr,
Jim Beall,
Dan Becker,
Hsaio-Mei Cho,
Mark Devlin,
Bradley Dober,
Chris Groppi,
Gene C. Hilton,
Kent D. Irwin,
Dale Li,
Phillip Mauskopf,
Dave P. Pappas,
Jeff Van Lanen,
Michael R. Vissers,
Yiwen Wang,
Lian-Fu Wei,
Jiansong Gao
Abstract:
We demonstrate photon-noise limited performance at sub-millimeter wavelengths in feedhorn-coupled, microwave kinetic inductance detectors (MKIDs) made of a TiN/Ti/TiN trilayer superconducting film, tuned to have a transition temperature of 1.4~K. Micro-machining of the silicon-on-insulator wafer backside creates a quarter-wavelength backshort optimized for efficient coupling at 250~\micron. Using…
▽ More
We demonstrate photon-noise limited performance at sub-millimeter wavelengths in feedhorn-coupled, microwave kinetic inductance detectors (MKIDs) made of a TiN/Ti/TiN trilayer superconducting film, tuned to have a transition temperature of 1.4~K. Micro-machining of the silicon-on-insulator wafer backside creates a quarter-wavelength backshort optimized for efficient coupling at 250~\micron. Using frequency read out and when viewing a variable temperature blackbody source, we measure device noise consistent with photon noise when the incident optical power is $>$~0.5~pW, corresponding to noise equivalent powers $>$~3$\times 10^{-17}$ W/$\sqrt{\mathrm{Hz}}$. This sensitivity makes these devices suitable for broadband photometric applications at these wavelengths.
△ Less
Submitted 23 March, 2015; v1 submitted 16 June, 2014;
originally announced June 2014.
-
Current distribution and transition width in superconducting transition-edge sensors
Authors:
D. S. Swetz,
D. A. Bennett,
K. D. Irwin,
D. R. Schmidt,
J. N. Ullom
Abstract:
Present models of the superconducting-to-normal transition in transition-edge sensors (TESs) do not describe the current distribution within a biased TES. This distribution is complicated by normal-metal features that are integral to TES design. We present a model with one free parameter that describes the evolution of the current distribution with bias. To probe the current distribution experimen…
▽ More
Present models of the superconducting-to-normal transition in transition-edge sensors (TESs) do not describe the current distribution within a biased TES. This distribution is complicated by normal-metal features that are integral to TES design. We present a model with one free parameter that describes the evolution of the current distribution with bias. To probe the current distribution experimentally, we fabricated TES devices with different current return geometries. Devices where the current return geometry mirrors current flow within the device have sharper transitions, thus allowing for a direct test of the current-flow model. Measurements from these devices show that current meanders through a TES low in the resistive transition but flows across the normal-metal features by 40% of the normal-state resistance. Comparison of transition sharpness between device designs reveals that self-induced magnetic fields play an important role in determining the width of the superconducting transition. [http://dx.doi.org/10.1063/1.4771984]
△ Less
Submitted 14 December, 2012;
originally announced December 2012.
-
Proximity-Coupled Ti/TiN Multilayers for use in Kinetic Inductance Detectors
Authors:
Michael R. Vissers,
Jiansong Gao,
Martin Sandberg,
Shannon M. Duff,
David S. Wisbey,
Kent D. Irwin,
David P. Pappas
Abstract:
We apply the superconducting proximity effect in TiN/Ti multi-layer films to tune the critical temperature, Tc, to within 10 mK with high uniformity (less than 15 mK spread) across a 75 mm wafer. Reproducible Tc's are obtained from 0.8 - 2.5 K. These films had high resistivities, > 100 uOhm-cm and internal quality factors for resonators in the GHz range on the order of 100k and higher. Both trilay…
▽ More
We apply the superconducting proximity effect in TiN/Ti multi-layer films to tune the critical temperature, Tc, to within 10 mK with high uniformity (less than 15 mK spread) across a 75 mm wafer. Reproducible Tc's are obtained from 0.8 - 2.5 K. These films had high resistivities, > 100 uOhm-cm and internal quality factors for resonators in the GHz range on the order of 100k and higher. Both trilayers of TiN/Ti/TiN and thicker superlattice films were prepared, demonstrating a highly controlled process for films over a wide thickness range. Detectors were fabricated and showed single photon resolution at 1550 nm. The high uniformity and controllability coupled with the high quality factor, kinetic inductance, and inertness of TiN make these films ideal for use in frequency multiplexed kinetic inductance detectors and other potential applications such as nanowire detectors, transition edge sensors and associated quantum information applications.
△ Less
Submitted 21 September, 2012;
originally announced September 2012.
-
A titanium-nitride near-infrared kinetic inductance photon-counting detector and its anomalous electrodynamics
Authors:
J. Gao,
M. R. Visser,
M. O. Sandberg,
F. C. S. da Silva,
S. W. Nam,
D. P. Pappas,
K. D. Irwin,
D. S. Wisbey,
E. Langman,
S. R. Meeker,
B. A. Mazin,
H. G. Leduc,
J. Zmuidzinas
Abstract:
We demonstrate single-photon counting at 1550 nm with titanium-nitride (TiN) microwave kinetic inductance detectors. Energy resolution of 0.4 eV and arrival-time resolution of 1.2 microseconds are achieved. 0-, 1-, 2-photon events are resolved and shown to follow Poisson statistics. We find that the temperature-dependent frequency shift deviates from the Mattis-Bardeen theory, and the dissipation…
▽ More
We demonstrate single-photon counting at 1550 nm with titanium-nitride (TiN) microwave kinetic inductance detectors. Energy resolution of 0.4 eV and arrival-time resolution of 1.2 microseconds are achieved. 0-, 1-, 2-photon events are resolved and shown to follow Poisson statistics. We find that the temperature-dependent frequency shift deviates from the Mattis-Bardeen theory, and the dissipation response shows a shorter decay time than the frequency response at low temperatures. We suggest that the observed anomalous electrodynamics may be related to quasiparticle traps or subgap states in the disordered TiN films. Finally, the electron density-of-states is derived from the pulse response.
△ Less
Submitted 3 August, 2012;
originally announced August 2012.
-
Pure dephasing in flux qubits due to flux noise with spectral density scaling as $1/ f^α$
Authors:
S. M. Anton,
C. Müller,
J. S. Birenbaum,
S. R. O'Kelley,
A. D. Fefferman,
D. S. Golubev,
G. C. Hilton,
H. -M. Cho,
K. D. Irwin,
F. C. Wellstood,
Gerd Schön,
A. Shnirman,
John Clarke
Abstract:
For many types of superconducting qubits, magnetic flux noise is a source of pure dephasing. Measurements on a representative dc superconducting quantum interference device (SQUID) over a range of temperatures show that $S_Φ(f) = A^2/(f/1 \hbox{Hz})^α$, where $S_Φ$ is the flux noise spectral density, $A$ is of the order of 1 $μΦ_0 \, \hbox{Hz}^{-1/2}$ and $0.61 \leq α\leq 0.95$; $Φ_{0}$ is the flu…
▽ More
For many types of superconducting qubits, magnetic flux noise is a source of pure dephasing. Measurements on a representative dc superconducting quantum interference device (SQUID) over a range of temperatures show that $S_Φ(f) = A^2/(f/1 \hbox{Hz})^α$, where $S_Φ$ is the flux noise spectral density, $A$ is of the order of 1 $μΦ_0 \, \hbox{Hz}^{-1/2}$ and $0.61 \leq α\leq 0.95$; $Φ_{0}$ is the flux quantum. For a qubit with an energy level splitting linearly coupled to the applied flux, calculations of the dependence of the pure dephasing time $τ_φ$ of Ramsey and echo pulse sequences on $α$ for fixed $A$ show that $τ_φ$ decreases rapidly as $α$ is reduced. We find that $τ_φ$ is relatively insensitive to the noise bandwidth, $f_1 \leq f \leq f_2$, for all $α$ provided the ultraviolet cutoff frequency $f_2 > 1/τ_φ$. We calculate the ratio $τ_{φ,E} / τ_{φ,R}$ of the echo ($E$) and Ramsey ($R$) sequences, and the dependence of the decay function on $α$ and $f_2$. We investigate the case in which $S_Φ(f_0)$ is fixed at the "pivot frequency" $f_0 \neq 1$ Hz while $α$ is varied, and find that the choice of $f_0$ can greatly influence the sensitivity of $τ_{φ,E}$ and $τ_{φ,R}$ to the value of $α$. Finally, we present calculated values of $τ_φ$ in a qubit corresponding to the values of $A$ and $α$ measured in our SQUID.
△ Less
Submitted 16 February, 2012; v1 submitted 30 November, 2011;
originally announced November 2011.
-
Advanced code-division multiplexers for superconducting detector arrays
Authors:
K. D. Irwin,
H. M. Cho,
W. B. Doriese,
J. W. Fowler,
G. C. Hilton,
M. D. Niemack,
C. D. Reintsema,
D. R. Schmidt,
J. N. Ullom,
L. R. Vale
Abstract:
Multiplexers based on the modulation of superconducting quantum interference devices are now regularly used in multi-kilopixel arrays of superconducting detectors for astrophysics, cosmology, and materials analysis. Over the next decade, much larger arrays will be needed. These larger arrays require new modulation techniques and compact multiplexer elements that fit within each pixel. We present a…
▽ More
Multiplexers based on the modulation of superconducting quantum interference devices are now regularly used in multi-kilopixel arrays of superconducting detectors for astrophysics, cosmology, and materials analysis. Over the next decade, much larger arrays will be needed. These larger arrays require new modulation techniques and compact multiplexer elements that fit within each pixel. We present a new in-focal-plane code-division multiplexer that provides multiplexing elements with the required scalability. This code-division multiplexer uses compact lithographic modulation elements that simultaneously multiplex both signal outputs and superconducting transition-edge sensor (TES) detector bias voltages. It eliminates the shunt resistor used to voltage bias TES detectors, greatly reduces power dissipation, allows different dc bias voltages for each TES, and makes all elements sufficiently compact to fit inside the detector pixel area. These in-focal-plane code-division multiplexers can be combined with multi-gigahertz readout based on superconducting microresonators to scale to even larger arrays.
△ Less
Submitted 7 October, 2011;
originally announced October 2011.
-
Quantum state tomography of an itinerant squeezed microwave field
Authors:
F. Mallet,
M. A. Castellanos-Beltran,
H. S. Ku,
S. Glancy,
E. Knill,
K. D. Irwin,
G. C. Hilton,
L. R. Vale,
K. W. Lehnert
Abstract:
We perform state tomography of an itinerant squeezed state of the microwave field prepared by a Josephson parametric amplifier (JPA). We use a second JPA as a pre-amplifier to improve the quantum efficiency of the field quadrature measurement (QM) from 2% to 36 +/- 4%. Without correcting for the detection inefficiency we observe a minimum quadrature variance which is 69 +/- 8% of the variance of t…
▽ More
We perform state tomography of an itinerant squeezed state of the microwave field prepared by a Josephson parametric amplifier (JPA). We use a second JPA as a pre-amplifier to improve the quantum efficiency of the field quadrature measurement (QM) from 2% to 36 +/- 4%. Without correcting for the detection inefficiency we observe a minimum quadrature variance which is 69 +/- 8% of the variance of the vacuum. We reconstruct the state's density matrix by a maximum likelihood method and infer that the squeezed state has a minimum variance less than 40% of the vacuum, with uncertainty mostly caused by calibration systematics.
△ Less
Submitted 6 May, 2011; v1 submitted 30 November, 2010;
originally announced December 2010.
-
Time-division SQUID multiplexers with reduced sensitivity to external magnetic fields
Authors:
G. M. Stiehl,
H. M. Cho,
G. C. Hilton,
K. D. Irwin,
J. A. B. Mates,
C. D. Reintsema,
B. L. Zink
Abstract:
Time-division SQUID multiplexers are used in many applications that require exquisite control of systematic error. One potential source of systematic error is the pickup of external magnetic fields in the multiplexer. We present measurements of the field sensitivity figure of merit, effective area, for both the first stage and second stage SQUID amplifiers in three NIST SQUID multiplexer designs.…
▽ More
Time-division SQUID multiplexers are used in many applications that require exquisite control of systematic error. One potential source of systematic error is the pickup of external magnetic fields in the multiplexer. We present measurements of the field sensitivity figure of merit, effective area, for both the first stage and second stage SQUID amplifiers in three NIST SQUID multiplexer designs. These designs include a new variety with improved gradiometry that significantly reduces the effective area of both the first and second stage SQUID amplifiers.
△ Less
Submitted 30 August, 2010;
originally announced August 2010.
-
Strongly quadrature-dependent noise in superconducting micro-resonators measured at the vacuum-noise limit
Authors:
J. Gao,
L. R. Vale,
J. A. B. Mates,
D. R. Schmidt,
G. C. Hilton,
K. D. Irwin,
F. Mallet,
M. A. Castellanos-Beltran,
K. W. Lehnert,
J. Zmuidzinas,
H. G. Leduc
Abstract:
We measure frequency- and dissipation-quadrature noise in superconducting lithographed microwave resonators with sensitivity near the vacuum noise level using a Josephson parametric amplifier. At an excitation power of 100~nW, these resonators show significant frequency noise caused by two-level systems. No excess dissipation-quadrature noise (above the vacuum noise) is observed to our measurement…
▽ More
We measure frequency- and dissipation-quadrature noise in superconducting lithographed microwave resonators with sensitivity near the vacuum noise level using a Josephson parametric amplifier. At an excitation power of 100~nW, these resonators show significant frequency noise caused by two-level systems. No excess dissipation-quadrature noise (above the vacuum noise) is observed to our measurement sensitivity. These measurements demonstrate that the excess dissipation-quadrature noise is negligible compared to vacuum fluctuations, at typical readout powers used in micro-resonator applications. Our results have important implications for resonant readout of various devices such as detectors, qubits and nano-mechanical oscillators.
△ Less
Submitted 30 July, 2010;
originally announced August 2010.
-
Bandwidth and dynamic range of a widely tunable Josephson parametric amplifier
Authors:
M. A. Castellanos-Beltran,
K. D. Irwin,
L. R. Vale,
G. C. Hilton,
K. W. Lehnert
Abstract:
The ability to manipulate quantum information encoded in microwave fields has led to a renewed interest in Josephson parametric amplifiers (JPAs). For these applications the ability of JPAs to amplify signals with the least amount of added noise is critical. Unfortunately JPAs are typically narrow band amplifiers with small dynamic range. It is therefore important to understand the bandwidth and…
▽ More
The ability to manipulate quantum information encoded in microwave fields has led to a renewed interest in Josephson parametric amplifiers (JPAs). For these applications the ability of JPAs to amplify signals with the least amount of added noise is critical. Unfortunately JPAs are typically narrow band amplifiers with small dynamic range. It is therefore important to understand the bandwidth and dynamic range of any particular JPA in order to determine if it is appropriate for these applications. We recently introduced a new kind of JPA. Although it is still narrow band, the amplified band can be tuned over a full octave. We have shown that it has good noise performance and can squeeze the vacuum noise by 10 dB. Here we characterize other important parameters of this amplifier, specifically the signal-bandwidth, dynamic range and saturation power.
△ Less
Submitted 6 March, 2009;
originally announced March 2009.
-
Amplification and squeezing of quantum noise with a tunable Josephson metamaterial
Authors:
M. A. Castellanos-Beltran,
K. D. Irwin,
G. C. Hilton,
L. R. Vale,
K. W. Lehnert
Abstract:
It has recently become possible to encode the quantum state of superconducting qubits and the position of nanomechanical oscillators into the states of microwave fields. However, to make an ideal measurement of the state of a qubit, or to detect the position of a mechanical oscillator with quantum-limited sensitivity requires an amplifier that adds no noise. If an amplifier adds less than half a…
▽ More
It has recently become possible to encode the quantum state of superconducting qubits and the position of nanomechanical oscillators into the states of microwave fields. However, to make an ideal measurement of the state of a qubit, or to detect the position of a mechanical oscillator with quantum-limited sensitivity requires an amplifier that adds no noise. If an amplifier adds less than half a quantum of noise, it can also squeeze the quantum noise of the electromagnetic vacuum. Highly squeezed states of the vacuum serve as an important quantum information resource. They can be used to generate entanglement or to realize back-action-evading measurements of position. Here we introduce a general purpose parametric device, which operates in a frequency band between 4 and 8 GHz. It is a subquantum-limited microwave amplifier, it amplifies quantum noise above the added noise of commercial amplifiers, and it squeezes quantum fluctuations by 10 dB.
△ Less
Submitted 3 June, 2008;
originally announced June 2008.