arXiv:1604.02536 [pdf, ps, other]
Performance of an X-ray single pixel TES microcalorimeter under DC and AC biasing
Abstract: We are developing Frequency Domain Multiplexing (FDM) for the read-out of TES imaging microcalorimeter arrays for future X-ray missions like IXO. In the FDMconfiguration the TES is AC voltage biased at a well defined frequencies (between 0.3 to 10MHz) and acts as an AM modulating element. In this paper we will present a full comparison of the performance of a TES microcalorimeter under DC bias and… ▽ More
Submitted 9 April, 2016; originally announced April 2016.
Comments: 4 pages, 5 figuers, the Thirteenth International Workshop on Low Temperature Detectors LTD13
Journal ref: AIP Conf. Proc. 1185, 538 (2009)
-
arXiv:1604.02535 [pdf, ps, other]
Characterisation of a TES-Based X-ray Microcalorimeter in the Energy Range from 150 to 1800 eV Using an Adiabatic Demagnetisation Refrigerator
Abstract: We characterised a TES-based X-ray microcalorimeter in an adiabatic demagnetisation refrigerator (ADR) using synchrotron radiation. The detector response and energy resolution was measured at the beam-line in the PTB radiometry laboratory at the electron storage ring BESSY II in the range from 200 to 1800 eV. We present and discuss the results of the energy resolution measurements as a function of… ▽ More
Submitted 9 April, 2016; originally announced April 2016.
Comments: 6 pages, 5 figures, Proceedings of the 12th International Workshop on Low Temperature Detectors (LTD12)
Journal ref: Journal of Low Temperature Physics, April 2008, Volume 151, Issue 1, pp 106-111
-
arXiv:1604.00553 [pdf, ps, other]
Development of TES-based detectors array for the X-ray Integral Field Unit (X-IFU) on the future x-ray observatory ATHENA
Abstract: We are developing transition-edge sensor (TES)-based microcalorimeters for the X-ray Integral Field Unit (XIFU) of the future European X-Ray Observatory Athena. The microcalorimeters are based on TiAu TESs coupled to 250μm squared, AuBi absorbers. We designed and fabricated devices with different contact geometries between the absorber and the TES to optimise the detector performance and with diff… ▽ More
Submitted 2 April, 2016; originally announced April 2016.
Comments: 9 pages, 8 figures
Journal ref: Proc. SPIE 9144, Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray, 91442M (July 25, 2014)
-
Analysis of impedance and noise data of an X-ray transition-edge sensor using complex thermal models
Abstract: The so-called excess noise limits the energy resolution of transition-edge sensor (TES) detectors, and its physical origin has been unclear, with many competing models proposed. Here we present the noise and impedance data analysis of a rectangular X-ray Ti/Au TES fabricated at SRON. To account for all the major features in the impedance and noise data simultaneously, we have used a thermal model… ▽ More
Submitted 2 December, 2011; originally announced December 2011.
Comments: 6 pages, 5 figures
-
Fluctuation superconductivity limited noise in a transition-edge sensor
Abstract: In order to investigate the origin of the until now unaccounted excess noise and to minimize the uncontrollable phenomena at the transition in X-ray microcalorimeters we have developed superconducting transition-edge sensors into an edgeless geometry, the so-called Corbino disk (CorTES), with superconducting contacts in the centre and at the outer perimeter. The measured rms current noise and it… ▽ More
Submitted 29 April, 2003; v1 submitted 18 February, 2003; originally announced February 2003.
Comments: 9 pages, 4 figures.; Corrections to text and equations; replaced the affected figures. Added reference [12]
Journal ref: Phys.Rev.Lett. 90 (2003) 238306