-
Analytical prediction for the steady-state behavior of a confined drop with interface viscosity under shear flow
Authors:
Fabio Guglietta,
Francesca Pelusi
Abstract:
The steady-state behavior of a single drop under shear flow has been extensively investigated in the limit of small deformation and negligible inertia effects. In this work, we combine the calculations proposed by Flumerfelt [R. W. Flumerfelt, J. Colloid Interface Sci. 76, 330 (1980)] for unconfined drops with interface viscosity, with those by Shapira & Haber [M. Shapira and S. Haber, Int. J. Mul…
▽ More
The steady-state behavior of a single drop under shear flow has been extensively investigated in the limit of small deformation and negligible inertia effects. In this work, we combine the calculations proposed by Flumerfelt [R. W. Flumerfelt, J. Colloid Interface Sci. 76, 330 (1980)] for unconfined drops with interface viscosity, with those by Shapira & Haber [M. Shapira and S. Haber, Int. J. Multiph. Flow. 16, 305 (1990)] for confined drops without interface viscosity. By merging these two approaches, we provide comprehensive analytical predictions for steady-state drop deformation and inclination angle across a wide range of physical conditions, from confined to unconfined droplets, including or excluding the effect of interface viscosity. The proposed analytical predictions are also robust concerning variations in the viscosity ratio, making our model general enough to include any of the above conditions.
△ Less
Submitted 3 November, 2024; v1 submitted 23 April, 2024;
originally announced April 2024.
-
Suspensions of viscoelastic capsules: effect of membrane viscosity on transient dynamics
Authors:
Fabio Guglietta,
Francesca Pelusi,
Marcello Sega,
Othmane Aouane,
Jens Harting
Abstract:
Membrane viscosity is known to play a central role in the transient dynamics of isolated viscoelastic capsules by decreasing their deformation, inducing shape oscillations and reducing the loading time, that is, the time required to reach the steady-state deformation. However, for dense suspensions of capsules, our understanding of the influence of the membrane viscosity is minimal. In this work,…
▽ More
Membrane viscosity is known to play a central role in the transient dynamics of isolated viscoelastic capsules by decreasing their deformation, inducing shape oscillations and reducing the loading time, that is, the time required to reach the steady-state deformation. However, for dense suspensions of capsules, our understanding of the influence of the membrane viscosity is minimal. In this work, we perform a systematic numerical investigation based on coupled immersed boundary -- lattice Boltzmann (IB-LB) simulations of viscoelastic spherical capsule suspensions in the non-inertial regime. We show the effect of the membrane viscosity on the transient dynamics as a function of volume fraction and capillary number. Our results indicate that the influence of membrane viscosity on both deformation and loading time strongly depends on the volume fraction in a non-trivial manner: dense suspensions with large surface viscosity are more resistant to deformation but attain loading times that are characteristic of capsules with no surface viscosity, thus opening the possibility to obtain richer combinations of mechanical features.
△ Less
Submitted 3 July, 2023; v1 submitted 7 February, 2023;
originally announced February 2023.
-
Loading and relaxation dynamics of a red blood cell
Authors:
Fabio Guglietta,
Marek Behr,
Giacomo Falcucci,
Mauro Sbragaglia
Abstract:
We use mesoscale numerical simulations to investigate the unsteady dynamics of a single red blood cell (RBC) subjected to an external mechanical load. We carry out a detailed comparison between the {\it loading} (L) dynamics, following the imposition of the mechanical load on the RBC at rest, and the {\it relaxation} (R) dynamics, allowing the RBC to relax to its original shape after the sudden ar…
▽ More
We use mesoscale numerical simulations to investigate the unsteady dynamics of a single red blood cell (RBC) subjected to an external mechanical load. We carry out a detailed comparison between the {\it loading} (L) dynamics, following the imposition of the mechanical load on the RBC at rest, and the {\it relaxation} (R) dynamics, allowing the RBC to relax to its original shape after the sudden arrest of the mechanical load. Such a comparison is carried out by analyzing the characteristic times of the two corresponding dynamics, i.e., $t_L$ and $t_R$. When the intensity of the mechanical load is small enough, the two kinds of dynamics are {\it symmetrical} ($t_L \approx t_R$) and independent of the typology of mechanical load (intrinsic dynamics); otherwise, in marked contrast, an {\it asymmetry} is found, wherein the loading dynamics is typically faster than the relaxation one. This asymmetry manifests itself with non-universal characteristics, e.g., dependency on the applied load and/or on the viscoelastic properties of the RBC membrane. To deepen such a non-universal behaviour, we consider the viscosity of the erythrocyte membrane as a variable parameter and focus on three different typologies of mechanical load (mechanical stretching, shear flow, elongational flow): this allows to clarify how non-universality builds up in terms of the deformation and rotational contributions induced by the mechanical load on the membrane. Finally, we also investigate the effect of the elastic shear modulus on the characteristic times $t_L$ and $t_R$. Our results provide crucial and quantitative information on the unsteady dynamics of RBC and its membrane response to the imposition/cessation of external mechanical loads.
△ Less
Submitted 31 May, 2021; v1 submitted 17 February, 2021;
originally announced February 2021.
-
Lattice Boltzmann simulations on the tumbling to tank-treading transition: effects of membrane viscosity
Authors:
Fabio Guglietta,
Marek Behr,
Luca Biferale,
Giacomo Falcucci,
Mauro Sbragaglia
Abstract:
The tumbling to tank-treading (TB-TT) transition for red blood cells (RBCs) has been widely investigated, with a main focus on the effects of the viscosity ratio $λ$ (i.e., the ratio between the viscosities of the fluids inside and outside the membrane) and the shear rate $\dotγ$ applied to the RBC. However, the membrane viscosity $μ_m$ plays a major role in a realistic description of RBC's dynami…
▽ More
The tumbling to tank-treading (TB-TT) transition for red blood cells (RBCs) has been widely investigated, with a main focus on the effects of the viscosity ratio $λ$ (i.e., the ratio between the viscosities of the fluids inside and outside the membrane) and the shear rate $\dotγ$ applied to the RBC. However, the membrane viscosity $μ_m$ plays a major role in a realistic description of RBC's dynamics, and only a few works have systematically focused on its effects on the TB-TT transition. In this work, we provide a parametric investigation on the effect of membrane viscosity $μ_m$ on the TB-TT transition, for a single RBC. It is found that, at fixed viscosity ratios $λ$, larger values of $μ_m$ lead to an increased range of values of capillary number at which the TB-TT transition occurs. We systematically quantify such an increase by means of mesoscale numerical simulations based on the lattice Boltzmann models.
△ Less
Submitted 11 December, 2020;
originally announced December 2020.
-
On the effects of membrane viscosity on transient red blood cell dynamics
Authors:
F. Guglietta,
M. Behr,
L. Biferale,
G. Falcucci,
M. Sbragaglia
Abstract:
Computational Fluid Dynamics (CFD) is currently used to design and improve the hydraulic properties of biomedical devices, wherein the large scale blood circulation needs to be simulated by accounting for the mechanical response of red blood cells (RBCs) at mesoscales. In many practical instances, biomedical devices work on time-scales comparable to the intrinsic relaxation time of RBCs: thus, a s…
▽ More
Computational Fluid Dynamics (CFD) is currently used to design and improve the hydraulic properties of biomedical devices, wherein the large scale blood circulation needs to be simulated by accounting for the mechanical response of red blood cells (RBCs) at mesoscales. In many practical instances, biomedical devices work on time-scales comparable to the intrinsic relaxation time of RBCs: thus, a systematic understanding of the time-dependent response of erythrocyte membranes is crucial for the effective design of such devices. So far, this information has been deduced from experimental data, which do not necessarily adapt to the the broad variety of the fluid dynamic conditions that can be encountered in practice. This work explores the novel possibility of studying the time-dependent response of an erythrocyte membrane to external mechanical loads via ab-initio, mesoscale numerical simulations, with a primary focus on the detailed characterisation of the RBC relaxation time $t_c$ following the arrest of the external mechanical load. The adopted mesoscale model exploits a hybrid Immersed Boundary-Lattice Boltzmann Method (IB-LBM), coupled with the Standard Linear Solid model (SLS) to account for the RBC membrane viscosity. We underscore the key importance of the 2D membrane viscosity $μ_{m}$ to correctly reproduce the relaxation time of the RBC membrane. A detailed assessment of the dependencies on the typology and strength of the applied mechanical loads is also provided. Overall, our findings open interesting future perspectives for the study of the non-linear response of RBCs immersed in time-dependent strain fields.
△ Less
Submitted 23 December, 2024; v1 submitted 8 April, 2020;
originally announced April 2020.