The Upscattering of Ultracold Neutrons from the polymer $[C_6 H_{12}]_n$
Abstract: It is generally accepted that the main cause of ultracold neutron (UCN) losses in storage traps is the upscattering to the thermal energy range by hydrogen adsorbed on the surface of the trap walls. However, the data on which this conclusion is based are poor and contradictory. Here, we report a measurement, performed at the Los Alamos National Laboratory UCN source, of the average energy of the f… ▽ More
Submitted 12 August, 2013; originally announced August 2013.
Report number: LA-UR-13-25898
Journal ref: Phys. Rev. C 88, 064605 (2013)
-
arXiv:1203.5938 [pdf, ps, other]
Mirrors for slow neutrons from holographic nanoparticle-polymer free-standing film-gratings
Abstract: We report on successful tests of holographically arranged grating-structures in nanoparticle-polymer composites in the form of 100 microns thin free-standing films, i.e. without sample containers or covers that could cause unwanted absorption/incoherent scattering of very-cold neutrons. Despite their large diameter of 2 cm, the flexible materials are of high optical quality and yield mirror-like r… ▽ More
Submitted 27 March, 2012; originally announced March 2012.
Journal ref: Appl. Phys. Lett. 100, 214104 (2012)
-
arXiv:1106.1362 [pdf, ps, other]
Diffraction of slow neutrons by holographic SiO_2 nanoparticle-polymer composite gratings
Abstract: Diffraction experiments with holographic gratings recorded in SiO$_2$ nanoparticle-polymer composites have been carried out with slow neutrons. The influence of parameters such as nanoparticle concentration, grating thickness and grating spacing on the neutron-optical properties of such materials has been tested. Decay of the grating structure along the sample depth due to disturbance of the recor… ▽ More
Submitted 7 June, 2011; originally announced June 2011.
Comments: 7 pages, 3 figures, submitted to Phys. Rev. A
Journal ref: Phys. Rev. A84:013621,2011
-
A Differential Time-of-flight Spectrometer of Very Slow Neutrons
Abstract: A time-of-flight spectrometer of neutrons in the energy range (0.05 -- 2.5)$μ$eV is described. This spectrometer has been tested my measuring the total and differential neutron cross sections for a number of materials: Al, Cu, $^{6}$LiF, Si, Zr, teflon, polyethylene and liquid fluoropolymers, that are essential for experiments in the physics of ultracold neutrons.
Submitted 14 February, 2011; originally announced February 2011.
Comments: 13 pages, 8 figures
Journal ref: Instruments and Exper. Techn., Vol. 54 (2011) p.16-22
-
Temperature Dependence of the UCN Loss Rate
Abstract: We report about the first results obtained with our Ultra High Vacuum cryostat recently commissioned at HMI to study Ultra Cold Neutrons(UCN) loss rate under low temperatures(down to 4K) and well controlled sample environment. Our analysis of the temperature dependence of UCN loss rate on Cu surface allowed us to rule out the subbarier model in support of the 1/v model and propose a reasonable e… ▽ More
Submitted 3 November, 2003; v1 submitted 20 November, 2002; originally announced November 2002.
Comments: 12 pages, 5 figures, complete analysis of the experimental data, version for submission