A high-speed, high-resolution Transition Edge Sensor spectrometer for soft X-rays at the Advanced Photon Source
Authors:
Orlando Quaranta,
Don Jensen,
Kelsey Morgan,
Joel C. Weber,
Jessica L. McChesney,
Hao Zheng,
Tejas Guruswamy,
Jonathan Baldwin,
Ben Mates,
Nathan Ortiz,
Johnathon Gard,
Doug Bennet,
Dan Schmidt,
Lisa Gades,
Antonino Miceli
Abstract:
This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X- ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a…
▽ More
This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X- ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National Institute of Standards and Technology (NIST). Soft X-ray scattering is a powerful technique for studying the electronic and magnetic properties of materials on a microscopic level. However, the lack of high-performance soft X-ray spectrometers has limited the potential of this technique. TES spectrometers have the potential to overcome these limitations due to their high energy resolution, high efficiency, and broad energy range. This project aims to optimize the design of a TES spectrometer for RSXS measurements and more generally soft X-ray spectroscopy at the Advanced Photon Source (APS) 29-ID, leading to improved understanding of advanced materials. We will present a detailed description of the instrument design and implementation. The spectrometer consists of a large array of approximately 250 high-speed and high-resolution pixels. The pixels have saturation energies of approximately 1 keV, sub-ms pulse duration and energy resolution of approximately 1 eV. The array is read out using microwave multiplexing chips with MHz bandwidth per channel, enabling efficient data throughput. To facilitate measurement of samples in situ under ultra-high vacuum conditions at the beamline, the spectrometer is integrated with an approximately 1 m long snout.
△ Less
Submitted 3 January, 2025;
originally announced January 2025.
-
On low-energy tail distortions in the detector responsefunction of x-ray microcalorimeter spectrometers
Authors:
G. C. O'Neil,
P. Szypryt,
E. Takacs,
J. N. Tan,
S. W. Buechele,
A. S. Naing,
Y. I. Joe,
D. Swetz,
D. R. Schmidt,
W. B. Doriese,
J. D. Gard,
C. D. Reintsema,
J. N. Ullom,
J. S. Villarrubia,
Yu. Ralchenko
Abstract:
We use narrow spectral lines from the x-ray spectra of various highlycharged ions to measure low-energy tail-like deviations from a Gaussian responsefunction in a microcalorimter x-ray spectrometer with Au absorbers at energiesfrom 650 eV to 3320 eV. We review the literature on low energy tails in othermicrocalorimter x-ray spectrometers and present a model that explains all thereviewed tail fract…
▽ More
We use narrow spectral lines from the x-ray spectra of various highlycharged ions to measure low-energy tail-like deviations from a Gaussian responsefunction in a microcalorimter x-ray spectrometer with Au absorbers at energiesfrom 650 eV to 3320 eV. We review the literature on low energy tails in othermicrocalorimter x-ray spectrometers and present a model that explains all thereviewed tail fraction measurements. In this model a low energy tail arises fromthe combination of electron escape and energy trapping associated with Bi x-rayabsorbers.
△ Less
Submitted 11 May, 2020;
originally announced May 2020.
-
Correlation functions for strongly confined wormlike chains
Authors:
Joel Gard,
Greg Morrison
Abstract:
Polymer models describing the statistics of biomolecules under confinement have applications to a wide range of single molecule experimental techniques and give insight into biologically relevant processes {\em{in vivo}}. In this paper, we determine the transverse position and bending correlation functions for a wormlike chain confined within slits and cylinders (with one and two confined dimensio…
▽ More
Polymer models describing the statistics of biomolecules under confinement have applications to a wide range of single molecule experimental techniques and give insight into biologically relevant processes {\em{in vivo}}. In this paper, we determine the transverse position and bending correlation functions for a wormlike chain confined within slits and cylinders (with one and two confined dimensions, respectively) using a mean field approach that enforces rigid constraints on average. We show the theoretical predictions accurately capture the statistics of a wormlike chain from Monte Carlo simulations in both confining geometries for both weak and strong confinement. We also show that the longitudinal correlation function is accurately computed for a chain confined to a slit, and leverage the accuracy of the model to suggest an experimental technique to infer the (often unobservable) transverse statistics from the (directly observable) longitudinal end-to-end distance.
△ Less
Submitted 15 September, 2023; v1 submitted 26 March, 2020;
originally announced March 2020.
-
A Model for Excess Johnson Noise in Superconducting Transition-edge Sensors
Authors:
Abigail Wessels,
Kelsey Morgan,
Daniel T. Becker,
Johnathon D. Gard,
Gene C. Hilton,
John A. B. Mates,
Carl D. Reintsema,
Daniel R. Schmidt,
Daniel S. Swetz,
Joel N. Ullom,
Leila R. Vale,
Douglas A. Bennett
Abstract:
Transition-Edge Sensors (TESs) are two-dimensional superconducting films used to detect energy or power. TESs are voltage biased in the resistive transition where the film resistance is both finite and a strong function of temperature. Electrical noise is observed in TESs that exceeds the predictions of existing noise theories. In this manuscript, we describe a model for the unexplained excess noi…
▽ More
Transition-Edge Sensors (TESs) are two-dimensional superconducting films used to detect energy or power. TESs are voltage biased in the resistive transition where the film resistance is both finite and a strong function of temperature. Electrical noise is observed in TESs that exceeds the predictions of existing noise theories. In this manuscript, we describe a model for the unexplained excess noise based on the dynamic resistance of the TES and noise mixed down from frequencies around the Josephson oscillations. We derive an expression for the power spectral density of this noise and show that its predictions match measured data.
△ Less
Submitted 25 July, 2019;
originally announced July 2019.