Nonlinear Behavior of Josephson Traveling Wave Parametric Amplifiers
Authors:
Claudio Guarcello,
Felix Ahrens,
Guerino Avallone,
Carlo Barone,
Matteo Borghesi,
Luca Callegaro,
Giovanni Carapella,
Anna Paola Caricato,
Iacopo Carusotto,
Alessandro Cian,
Alessandro D'Elia,
Daniele Di Gioacchino,
Emanuele Enrico,
Paolo Falferi,
Luca Fasolo,
Marco Faverzani,
Elena Ferri,
Giovanni Filatrella,
Claudio Gatti,
Andrea Giachero,
Damiano Giubertoni,
Veronica Granata,
Angelo Leo,
Danilo Labranca,
Carlo Ligi
, et al. (18 additional authors not shown)
Abstract:
Recent advancements in quantum technologies and advanced detection experiments have underscored the pressing need for the detection of exceedingly weak signals within the microwave frequency spectrum. Addressing this challenge, the Josephson Traveling Wave Parametric Amplifier (JTWPA) has been proposed as a cryogenic front-end amplifier capable of approaching the quantum noise limit while providin…
▽ More
Recent advancements in quantum technologies and advanced detection experiments have underscored the pressing need for the detection of exceedingly weak signals within the microwave frequency spectrum. Addressing this challenge, the Josephson Traveling Wave Parametric Amplifier (JTWPA) has been proposed as a cryogenic front-end amplifier capable of approaching the quantum noise limit while providing a relevant bandwidth. This research is centered on a comprehensive numerical investigation of the JTWPA, without resorting to simplifications regarding the nonlinearity of the essential components. Specifically, this study focuses on a thorough examination of the system, characterized by coupled nonlinear differential equations representing all components of the device. Proper input and output signals at the device's boundaries are considered. The analysis of the output signals undergoing the parametric amplification process involves a detailed exploration of phase-space dynamics and Fourier spectral analysis of the output voltage. This study is conducted while considering the parameters ruling the response of the device under pump and signal excitations. In addition to the expected signal amplification, the findings reveal that the nonlinear nature of the system can give rise to unforeseen phenomena, depending on the system's operational conditions, which include: the generation of pump tone harmonics, modulation of the signal gain, and incommensurate frequency generation-effects that are not easily accommodated by simplistic linearized approaches
△ Less
Submitted 3 March, 2024;
originally announced March 2024.
-
Progress in the development of a KITWPA for the DARTWARS project
Authors:
M. Borghesi,
C. Barone,
S. Capelli,
G. Carapella,
A. P. Caricato,
I. Carusotto,
A. Cian,
D. Di Gioacchino,
E. Enrico,
P. Falferi,
L. Fasolo,
M. Faverzani,
E. Ferri,
G. Filatrella,
C. Gatti,
A. Giachero,
D. Giubertoni,
V. Granata,
A. Greco,
C. Guarcello,
D. Labranca,
A. Leo,
C. Ligi,
G. Maccarrone,
F. Mantegazzini
, et al. (16 additional authors not shown)
Abstract:
DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) is a three years project that aims to develop high-performing innovative Traveling Wave Parametric Amplifiers (TWPAs) for low temperature detectors and qubit readout (C-band). The practical development follows two different promising approaches, one based on the Josephson junctions (TWJPA) and the other one based on the kinetic induc…
▽ More
DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) is a three years project that aims to develop high-performing innovative Traveling Wave Parametric Amplifiers (TWPAs) for low temperature detectors and qubit readout (C-band). The practical development follows two different promising approaches, one based on the Josephson junctions (TWJPA) and the other one based on the kinetic inductance of a high-resistivity superconductor (KITWPA). This paper presents the advancements made by the DARTWARS collaboration to produce a first working prototype of a KITWPA.
△ Less
Submitted 27 October, 2022; v1 submitted 22 August, 2022;
originally announced August 2022.
-
Heisenberg's uncertainty principle in the PTOLEMY project: a theory update
Authors:
PTOLEMY Collaboration,
A. Apponi,
M. G. Betti,
M. Borghesi,
A. Boyarsky,
N. Canci,
G. Cavoto,
C. Chang,
V. Cheianov,
Y. Cheipesh,
W. Chung,
A. G. Cocco,
A. P. Colijn,
N. D'Ambrosio,
N. de Groot,
A. Esposito,
M. Faverzani,
A. Ferella,
E. Ferri,
L. Ficcadenti,
T. Frederico,
S. Gariazzo,
F. Gatti,
C. Gentile,
A. Giachero
, et al. (36 additional authors not shown)
Abstract:
We discuss the consequences of the quantum uncertainty on the spectrum of the electron emitted by the $β$-processes of a tritium atom bound to a graphene sheet. We analyze quantitatively the issue recently raised in [Cheipesh et al., Phys. Rev. D 104, 116004 (2021)], and discuss the relevant time scales and the degrees of freedom that can contribute to the intrinsic spread in the electron energy.…
▽ More
We discuss the consequences of the quantum uncertainty on the spectrum of the electron emitted by the $β$-processes of a tritium atom bound to a graphene sheet. We analyze quantitatively the issue recently raised in [Cheipesh et al., Phys. Rev. D 104, 116004 (2021)], and discuss the relevant time scales and the degrees of freedom that can contribute to the intrinsic spread in the electron energy. We perform careful calculations of the potential between tritium and graphene with different coverages and geometries. With this at hand, we propose possible avenues to mitigate the effect of the quantum uncertainty.
△ Less
Submitted 6 September, 2022; v1 submitted 21 March, 2022;
originally announced March 2022.
-
Detector Array Readout with Traveling Wave Amplifiers
Authors:
A. Giachero,
C. Barone,
M. Borghesi,
G. Carapella,
A. P. Caricato,
I. Carusotto,
W. Chang,
A. Cian,
D. Di Gioacchino,
E. Enrico,
P. Falferi,
L. Fasolo,
M. Faverzani,
E. Ferri,
G. Filatrella,
C. Gatti,
D. Giubertoni,
A. Greco,
C. Kutlu,
A. Leo,
C. Ligi,
G. Maccarrone,
B. Margesin,
G. Maruccio,
A. Matlashov
, et al. (13 additional authors not shown)
Abstract:
Noise at the quantum limit over a large bandwidth is a fundamental requirement for future applications operating at millikelvin temperatures, such as the neutrino mass measurement, the next-generation x-ray observatory, the CMB measurement, the dark matter and axion detection, and the rapid high-fidelity readout of superconducting qubits. The read out sensitivity of arrays of microcalorimeter dete…
▽ More
Noise at the quantum limit over a large bandwidth is a fundamental requirement for future applications operating at millikelvin temperatures, such as the neutrino mass measurement, the next-generation x-ray observatory, the CMB measurement, the dark matter and axion detection, and the rapid high-fidelity readout of superconducting qubits. The read out sensitivity of arrays of microcalorimeter detectors, resonant axion-detectors, and qubits, is currently limited by the noise temperature and bandwidth of the cryogenic amplifiers. The DARTWARS (Detector Array Readout with Traveling Wave AmplifieRS) project has the goal of developing high-performing innovative traveling wave parametric amplifiers (TWPAs) with a high gain, a high saturation power, and a quantum-limited or nearly quantum-limited noise. The practical development follows two different promising approaches, one based on the Josephson junctions and the other one based on the kinetic inductance of a high-resistivity superconductor. In this contribution we present the aims of the project, the adopted design solutions and preliminary results from simulations and measurements.
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
Bimodal Approach for Noise Figures of Merit Evaluation in Quantum-Limited Josephson Traveling Wave Parametric Amplifiers
Authors:
L. Fasolo,
C. Barone,
M. Borghesi,
G. Carapella,
A. P. Caricato,
I. Carusotto,
W. Chung,
A. Cian,
D. Di Gioacchino,
E. Enrico,
P. Falferi,
M. Faverzani,
E. Ferri,
G. Filatrella,
C. Gatti,
A. Giachero,
D. Giubertoni,
A. Greco,
C. Kutlu,
A. Leo,
C. Ligi,
P. Livreri,
G. Maccarrone,
B. Margesin,
G. Maruccio
, et al. (15 additional authors not shown)
Abstract:
The advent of ultra-low noise microwave amplifiers revolutionized several research fields demanding quantum-limited technologies. Exploiting a theoretical bimodal description of a linear phase-preserving amplifier, in this contribution we analyze some of the intrinsic properties of a model architecture (i.e., an rf-SQUID based Josephson Traveling Wave Parametric Amplifier) in terms of amplificatio…
▽ More
The advent of ultra-low noise microwave amplifiers revolutionized several research fields demanding quantum-limited technologies. Exploiting a theoretical bimodal description of a linear phase-preserving amplifier, in this contribution we analyze some of the intrinsic properties of a model architecture (i.e., an rf-SQUID based Josephson Traveling Wave Parametric Amplifier) in terms of amplification and noise generation for key case study input states (Fock and coherents). Furthermore, we present an analysis of the output signals generated by the parametric amplification mechanism when thermal noise fluctuations feed the device.
△ Less
Submitted 29 December, 2021; v1 submitted 30 September, 2021;
originally announced September 2021.
-
Development of microwave superconducting microresonators for neutrino mass measurement in the HOLMES framework
Authors:
A. Giachero,
P. K. Day,
P. Falferi,
M. Faverzani,
E. Ferri,
C. Giordano,
M. Maino,
B. Margesin,
R. Mezzena,
R. Nizzolo,
A. Nucciotti,
A. Puiu,
L. Zanetti
Abstract:
The European Research Council has recently funded HOLMES, a project with the aim of performing a calorimetric measurement of the electron neutrino mass measuring the energy released in the electron capture decay of 163Ho. The baseline for HOLMES are microcalorimeters coupled to Transition Edge Sensors (TESs) read out with rf-SQUIDs, for microwave multiplexing purposes. A promising alternative solu…
▽ More
The European Research Council has recently funded HOLMES, a project with the aim of performing a calorimetric measurement of the electron neutrino mass measuring the energy released in the electron capture decay of 163Ho. The baseline for HOLMES are microcalorimeters coupled to Transition Edge Sensors (TESs) read out with rf-SQUIDs, for microwave multiplexing purposes. A promising alternative solution is based on superconducting microwave resonators, that have undergone rapid development in the last decade. These detectors, called Microwave Kinetic Inductance Detectors (MKIDs), are inherently multiplexed in the frequency domain and suitable for even larger-scale pixel arrays, with theoretical high energy resolution and fast response. The aim of our activity is to develop arrays of microresonator detectors for X-ray spectroscopy and suitable for the calorimetric measurement of the energy spectra of 163Ho. Superconductive multilayer films composed by a sequence of pure Titanium and stoichiometric TiN layers show many ideal properties for MKIDs, such as low loss, large sheet resistance, large kinetic inductance, and tunable critical temperature $T_c$. We developed Ti/TiN multilayer microresonators with $T_c$ within the range from 70 mK to 4.5 K and with good uniformity. In this contribution we present the design solutions adopted, the fabrication processes and the characterization results.
△ Less
Submitted 19 January, 2016; v1 submitted 17 September, 2015;
originally announced September 2015.
-
Critical Temperature tuning of Ti/TiN multilayer films suitable for low temperature detectors
Authors:
A. Giachero,
P. Day,
P. Falferi,
M. Faverzani,
E. Ferri,
C. Giordano,
B. Marghesin,
F. Mattedi,
R. Mezzena,
R. Nizzolo,
A. Nucciotti
Abstract:
We present our current progress on the design and test of Ti/TiN Multilayer for use in Kinetic Inductance Detectors (KIDs). Sensors based on sub-stoichiometric TiN film are commonly used in several applications. However, it is difficult to control the targeted critical temperature $T_C$, to maintain precise control of the nitrogen incorporation process and to obtain a production uniformity. To avo…
▽ More
We present our current progress on the design and test of Ti/TiN Multilayer for use in Kinetic Inductance Detectors (KIDs). Sensors based on sub-stoichiometric TiN film are commonly used in several applications. However, it is difficult to control the targeted critical temperature $T_C$, to maintain precise control of the nitrogen incorporation process and to obtain a production uniformity. To avoid these problems we investigated multilayer Ti/TiN films that show a high uniformity coupled with high quality factor, kinetic inductance and inertness of TiN. These features are ideal to realize superconductive microresonator detectors for astronomical instruments application but also for the field of neutrino physics. Using pure Ti and stoichiometric TiN, we developed and tested different multilayer configuration, in term of number of Ti/TiN layers and in term of different interlayer thicknesses. The target was to reach a critical temperature $T_C$ around $(1÷1.5)$ K in order to have a low energy gap and slower recombination time (i.e. low generation-recombination noise). The results prove that the superconductive transition can be tuned in the $(0.5÷4.6)$ K temperature range properly choosing the Ti thickness in the $(0÷15)$ nm range, and the TiN thickness in the $(5÷100)$ nm range
△ Less
Submitted 25 November, 2013; v1 submitted 14 July, 2013;
originally announced July 2013.