-
Strong kinetic-inductance Kerr nonlinearity with titanium nitride nanowires
Authors:
Chaitali Joshi,
Wenyuan Chen,
Henry G. LeDuc,
Peter K. Day,
Mohammad Mirhosseini
Abstract:
Thin films of disordered superconductors such as titanium nitride (TiN) exhibit large kinetic inductance (KI), high critical temperature, and large quality factors at the single-photon level. KI nonlinearity can be exploited as an alternative to Josephson junctions for creating novel nonlinear quantum devices with the potential to operate at higher frequencies and at elevated temperatures. We stud…
▽ More
Thin films of disordered superconductors such as titanium nitride (TiN) exhibit large kinetic inductance (KI), high critical temperature, and large quality factors at the single-photon level. KI nonlinearity can be exploited as an alternative to Josephson junctions for creating novel nonlinear quantum devices with the potential to operate at higher frequencies and at elevated temperatures. We study a means of magnifying KI nonlinearity by confining the current density of resonant electromagnetic modes in nanowires with a small volume $V \simeq 10^{-4}\text{um}^3$. Using this concept, we realize microwave-frequency Kerr cavities with a maximum Kerr-shift per photon of $K/2π= 123.5 \pm 3$ kHz and report a nonlinearity-to-linewidth ratio $K/γ= 21\%$. With improved design, our devices are expected to approach the regime of strong quantum nonlinearity in the millimeter-wave spectrum.
△ Less
Submitted 30 July, 2022;
originally announced August 2022.
-
Initial Design of a W-band Superconducting Kinetic Inductance Qubit (Kineticon)
Authors:
Farzad B. Faramarzi,
Peter K. Day,
Jacob Glasby,
Sasha Sypkens,
Marco Colangelo,
Ralph Chamberlin,
Mohammad Mirhosseini,
Kevin Schmidt,
Karl K. Berggren Philip Mauskopf
Abstract:
Superconducting qubits are widely used in quantum computing research and industry. We describe a superconducting kinetic inductance qubit (and introduce the term Kineticon to describe it) operating at W-band frequencies with a nonlinear nanowire section that provides the anharmonicity required for two distinct quantum energy states. Operating the qubits at higher frequencies may relax the dilution…
▽ More
Superconducting qubits are widely used in quantum computing research and industry. We describe a superconducting kinetic inductance qubit (and introduce the term Kineticon to describe it) operating at W-band frequencies with a nonlinear nanowire section that provides the anharmonicity required for two distinct quantum energy states. Operating the qubits at higher frequencies may relax the dilution refrigerator temperature requirements for these devices and paves the path for multiplexing a large number of qubits. Millimeter-wave operation requires superconductors with relatively high $T_c$, which implies high gap frequency, 2$Δ/h$, beyond which photons break Cooper pairs. For example, NbTiN with $T_c =15\,\text{K}$ has a gap frequency near 1.4 THz, which is much higher than that of aluminum (90 GHz), allowing for operation throughout the millimeter-wave band. Here we describe a design and simulation of a W-band Kineticon qubit embedded in a 3-D cavity. We perform classical electromagnetic calculations of the resulting field distributions.
△ Less
Submitted 14 March, 2021; v1 submitted 15 December, 2020;
originally announced December 2020.
-
Magnetic field dependence of the internal quality factor and noise performance of lumped-element kinetic inductance detectors
Authors:
Daniel Flanigan,
Bradley R. Johnson,
Maximilian H. Abitbol,
Sean Bryan,
Robin Cantor,
Peter K. Day,
Glenn Jones,
Philip Mauskopf,
Heather McCarrick,
Amber Miller,
Jonas Zmuidzinas
Abstract:
We present a technique for increasing the internal quality factor of kinetic inductance detectors (KIDs) by nulling ambient magnetic fields with a properly applied magnetic field. The KIDs used in this study are made from thin-film aluminum, they are mounted inside a light-tight package made from bulk aluminum, and they are operated near $150 \, \mathrm{mK}$. Since the thin-film aluminum has a sli…
▽ More
We present a technique for increasing the internal quality factor of kinetic inductance detectors (KIDs) by nulling ambient magnetic fields with a properly applied magnetic field. The KIDs used in this study are made from thin-film aluminum, they are mounted inside a light-tight package made from bulk aluminum, and they are operated near $150 \, \mathrm{mK}$. Since the thin-film aluminum has a slightly elevated critical temperature ($T_\mathrm{c} = 1.4 \, \mathrm{K}$), it therefore transitions before the package ($T_\mathrm{c} = 1.2 \, \mathrm{K}$), which also serves as a magnetic shield. On cooldown, ambient magnetic fields as small as approximately $30 \, \mathrm{μT}$ can produce vortices in the thin-film aluminum as it transitions because the bulk aluminum package has not yet transitioned and therefore is not yet shielding. These vortices become trapped inside the aluminum package below $1.2 \, \mathrm{K}$ and ultimately produce low internal quality factors in the thin-film superconducting resonators. We show that by controlling the strength of the magnetic field present when the thin film transitions, we can control the internal quality factor of the resonators. We also compare the noise performance with and without vortices present, and find no evidence for excess noise beyond the increase in amplifier noise, which is expected with increasing loss.
△ Less
Submitted 20 September, 2016;
originally announced September 2016.
-
Photon noise from chaotic and coherent millimeter-wave sources measured with horn-coupled, aluminum lumped-element kinetic inductance detectors
Authors:
Daniel Flanigan,
Heather McCarrick,
Glenn Jones,
Bradley R. Johnson,
Maximilian H. Abitbol,
Peter Ade,
Derek Araujo,
Kristi Bradford,
Robin Cantor,
George Che,
Peter K. Day,
Simon Doyle,
Carl Bjorn Kjellstrand,
Henry G LeDuc,
Michele Limon,
Vy Luu,
Philip Mauskopf,
Amber Miller,
Tony Mroczkowski,
Carole Tucker,
Jonas Zmuidzinas
Abstract:
We report photon-noise limited performance of horn-coupled, aluminum lumped-element kinetic inductance detectors at millimeter wavelengths. The detectors are illuminated by a millimeter-wave source that uses an active multiplier chain to produce radiation between 140 and 160 GHz. We feed the multiplier with either amplified broadband noise or a continuous-wave tone from a microwave signal generato…
▽ More
We report photon-noise limited performance of horn-coupled, aluminum lumped-element kinetic inductance detectors at millimeter wavelengths. The detectors are illuminated by a millimeter-wave source that uses an active multiplier chain to produce radiation between 140 and 160 GHz. We feed the multiplier with either amplified broadband noise or a continuous-wave tone from a microwave signal generator. We demonstrate that the detector response over a 40 dB range of source power is well-described by a simple model that considers the number of quasiparticles. The detector noise-equivalent power (NEP) is dominated by photon noise when the absorbed power is greater than approximately 1 pW, which corresponds to $\mathrm{NEP} \approx 2 \times 10^{-17} \, \mathrm{W} \, \mathrm{Hz}^{-1/2}$, referenced to absorbed power. At higher source power levels we observe the relationships between noise and power expected from the photon statistics of the source signal: $\mathrm{NEP} \propto P$ for broadband (chaotic) illumination and $\mathrm{NEP} \propto P^{1/2}$ for continuous-wave (coherent) illumination.
△ Less
Submitted 24 May, 2017; v1 submitted 22 October, 2015;
originally announced October 2015.
-
A frequency and sensitivity tunable microresonator array for high-speed quantum processor readout
Authors:
J. D. Whittaker,
L. J. Swenson,
M. H. Volkmann,
P. Spear,
F. Altomare,
A. J. Berkley,
B. Bumble,
P. Bunyk,
P. K. Day,
B. H. Eom,
R. Harris,
J. P. Hilton,
E. Hoskinson,
M. W. Johnson,
A. Kleinsasser,
E. Ladizinsky,
T. Lanting,
T. Oh,
I. Perminov,
E. Tolkacheva,
J. Yao
Abstract:
Superconducting microresonators have been successfully utilized as detection elements for a wide variety of applications. With multiplexing factors exceeding 1,000 detectors per transmission line, they are the most scalable low-temperature detector technology demonstrated to date. For high-throughput applications, fewer detectors can be coupled to a single wire but utilize a larger per-detector ba…
▽ More
Superconducting microresonators have been successfully utilized as detection elements for a wide variety of applications. With multiplexing factors exceeding 1,000 detectors per transmission line, they are the most scalable low-temperature detector technology demonstrated to date. For high-throughput applications, fewer detectors can be coupled to a single wire but utilize a larger per-detector bandwidth. For all existing designs, fluctuations in fabrication tolerances result in a non-uniform shift in resonance frequency and sensitivity, which ultimately limits the efficiency of band-width utilization. Here we present the design, implementation, and initial characterization of a superconducting microresonator readout integrating two tunable inductances per detector. We demonstrate that these tuning elements provide independent control of both the detector frequency and sensitivity, allowing us to maximize the transmission line bandwidth utilization. Finally we discuss the integration of these detectors in a multilayer fabrication stack for high-speed readout of the D-Wave quantum processor, highlighting the use of control and routing circuitry composed of single flux-quantum loops to minimize the number of control wires at the lowest temperature stage.
△ Less
Submitted 22 April, 2016; v1 submitted 18 September, 2015;
originally announced September 2015.
-
Development of microwave superconducting microresonators for neutrino mass measurement in the HOLMES framework
Authors:
A. Giachero,
P. K. Day,
P. Falferi,
M. Faverzani,
E. Ferri,
C. Giordano,
M. Maino,
B. Margesin,
R. Mezzena,
R. Nizzolo,
A. Nucciotti,
A. Puiu,
L. Zanetti
Abstract:
The European Research Council has recently funded HOLMES, a project with the aim of performing a calorimetric measurement of the electron neutrino mass measuring the energy released in the electron capture decay of 163Ho. The baseline for HOLMES are microcalorimeters coupled to Transition Edge Sensors (TESs) read out with rf-SQUIDs, for microwave multiplexing purposes. A promising alternative solu…
▽ More
The European Research Council has recently funded HOLMES, a project with the aim of performing a calorimetric measurement of the electron neutrino mass measuring the energy released in the electron capture decay of 163Ho. The baseline for HOLMES are microcalorimeters coupled to Transition Edge Sensors (TESs) read out with rf-SQUIDs, for microwave multiplexing purposes. A promising alternative solution is based on superconducting microwave resonators, that have undergone rapid development in the last decade. These detectors, called Microwave Kinetic Inductance Detectors (MKIDs), are inherently multiplexed in the frequency domain and suitable for even larger-scale pixel arrays, with theoretical high energy resolution and fast response. The aim of our activity is to develop arrays of microresonator detectors for X-ray spectroscopy and suitable for the calorimetric measurement of the energy spectra of 163Ho. Superconductive multilayer films composed by a sequence of pure Titanium and stoichiometric TiN layers show many ideal properties for MKIDs, such as low loss, large sheet resistance, large kinetic inductance, and tunable critical temperature $T_c$. We developed Ti/TiN multilayer microresonators with $T_c$ within the range from 70 mK to 4.5 K and with good uniformity. In this contribution we present the design solutions adopted, the fabrication processes and the characterization results.
△ Less
Submitted 19 January, 2016; v1 submitted 17 September, 2015;
originally announced September 2015.
-
Operation of a titanium nitride superconducting microresonator detector in the nonlinear regime
Authors:
L. J. Swenson,
P. K. Day,
B. H. Eom,
H. G. Leduc,
N. Llombart,
C. M. McKenney,
O. Noroozian,
J. Zmuidzinas
Abstract:
If driven sufficiently strongly, superconducting microresonators exhibit nonlinear behavior including response bifurcation. This behavior can arise from a variety of physical mechanisms including heating effects, grain boundaries or weak links, vortex penetration, or through the intrinsic nonlinearity of the kinetic inductance. Although microresonators used for photon detection are usually driven…
▽ More
If driven sufficiently strongly, superconducting microresonators exhibit nonlinear behavior including response bifurcation. This behavior can arise from a variety of physical mechanisms including heating effects, grain boundaries or weak links, vortex penetration, or through the intrinsic nonlinearity of the kinetic inductance. Although microresonators used for photon detection are usually driven fairly hard in order to optimize their sensitivity, most experiments to date have not explored detector performance beyond the onset of bifurcation. Here we present measurements of a lumped-element superconducting microresonator designed for use as a far-infrared detector and operated deep into the nonlinear regime. The 1 GHz resonator was fabricated from a 22 nm thick titanium nitride film with a critical temperature of 2 K and a normal-state resistivity of $100\, μΩ\,$cm. We measured the response of the device when illuminated with 6.4 pW optical loading using microwave readout powers that ranged from the low-power, linear regime to 18 dB beyond the onset of bifurcation. Over this entire range, the nonlinear behavior is well described by a nonlinear kinetic inductance. The best noise-equivalent power of $2 \times 10^{-16}$ W/Hz$^{1/2}$ at 10 Hz was measured at the highest readout power, and represents a $\sim$10 fold improvement compared with operating below the onset of bifurcation.
△ Less
Submitted 18 May, 2013;
originally announced May 2013.
-
Crosstalk Reduction for Superconducting Microwave Resonator Arrays
Authors:
Omid Noroozian,
Peter K. Day,
Byeong Ho Eom,
Henry G. Leduc,
Jonas Zmuidzinas
Abstract:
Large-scale arrays of Microwave Kinetic Inductance Detectors (MKIDs) are attractive candidates for use in imaging instruments for next generation submillimeter-wave telescopes such as CCAT. We have designed and fabricated tightly packed ~250-pixel MKID arrays using lumped-element resonators etched from a thin layer of superconducting TiNx deposited on a silicon substrate. The high pixel packing de…
▽ More
Large-scale arrays of Microwave Kinetic Inductance Detectors (MKIDs) are attractive candidates for use in imaging instruments for next generation submillimeter-wave telescopes such as CCAT. We have designed and fabricated tightly packed ~250-pixel MKID arrays using lumped-element resonators etched from a thin layer of superconducting TiNx deposited on a silicon substrate. The high pixel packing density in our initial design resulted in large microwave crosstalk due to electromagnetic coupling between the resonators. Our second design eliminates this problem by adding a grounding shield and using a double-wound geometry for the meander inductor to allow conductors with opposite polarity to be in close proximity. In addition, the resonator frequencies are distributed in a checkerboard pattern across the array. We present details for the two resonator and array designs and describe a circuit model for the full array that predicts the distribution of resonator frequencies and the crosstalk level. We also show results from a new experimental technique that conveniently measures crosstalk without the need for an optical setup. Our results reveal an improvement in crosstalk from 57% in the initial design down to \leq 2% in the second design. The general procedure and design guidelines in this work are applicable to future large arrays employing microwave resonators.
△ Less
Submitted 25 June, 2012;
originally announced June 2012.
-
Position and energy-resolved particle detection using phonon-mediated microwave kinetic inductance detectors
Authors:
D. C. Moore,
S. R. Golwala,
B. Bumble,
B. Cornell,
P. K. Day,
H. G. LeDuc,
J. Zmuidzinas
Abstract:
We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allows the location of the interaction to be determined with < 1 mm precision at 30 keV. Using this position information, variations…
▽ More
We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allows the location of the interaction to be determined with < 1 mm precision at 30 keV. Using this position information, variations in the detector response with position can be removed, and an energy resolution of σ_E = 0.55 keV at 30 keV was measured. Since MKIDs can be fabricated from a single deposited film and are naturally multiplexed in the frequency domain, this technology can be extended to provide highly-pixelized athermal phonon sensors for ~1 kg scale detector elements. Such high-resolution, massive particle detectors would be applicable to next-generation rare-event searches such as the direct detection of dark matter, neutrinoless double-beta decay, or coherent neutrino-nucleus scattering.
△ Less
Submitted 10 June, 2012; v1 submitted 20 March, 2012;
originally announced March 2012.
-
A Wideband, Low-Noise Superconducting Amplifier with High Dynamic Range
Authors:
Byeong Ho Eom,
Peter K. Day,
Henry G. Leduc,
Jonas Zmuidzinas
Abstract:
Amplifiers are ubiquitous in electronics and play a fundamental role in a wide range of scientific measurements. From a user's perspective, an ideal amplifier has very low noise, operates over a broad frequency range, and has a high dynamic range - it is capable of handling strong signals with little distortion. Unfortunately, it is difficult to obtain all of these characteristics simultaneously.…
▽ More
Amplifiers are ubiquitous in electronics and play a fundamental role in a wide range of scientific measurements. From a user's perspective, an ideal amplifier has very low noise, operates over a broad frequency range, and has a high dynamic range - it is capable of handling strong signals with little distortion. Unfortunately, it is difficult to obtain all of these characteristics simultaneously. For example, modern transistor amplifiers offer multi-octave bandwidths and excellent dynamic range. However, their noise remains far above the fundamental limit set by the uncertainty principle of quantum mechanics. Parametric amplifiers, which predate transistor amplifiers and are widely used in optics, exploit a nonlinear response to transfer power from a strong pump tone to a weak signal. If the nonlinearity is purely reactive, ie. nondissipative, in theory the amplifier noise can reach the quantum-mechanical limit. Indeed, microwave frequency superconducting Josephson parametric amplifiers do approach the quantum limit, but generally are narrow band and have very limited dynamic range. In this paper, we describe a superconducting parametric amplifier that overcomes these limitations. The amplifier is very simple, consisting only of a patterned metal film on a dielectric substrate, and relies on the nonlinear kinetic inductance of a superconducting transmission line. We measure gain extending over 2 GHz on either side of an 11.56 GHz pump tone, and we place an upper limit on the added noise of the amplifier of 3.4 photons at 9.4 GHz. Furthermore, the dynamic range is very large, comparable to microwave transistor amplifiers, and the concept can be applied throughout the microwave, millimeter-wave and submillimeter-wave bands.
△ Less
Submitted 11 January, 2012;
originally announced January 2012.
-
Titanium Nitride Films for Ultrasensitive Microresonator Detectors
Authors:
Henry G. Leduc,
Bruce Bumble,
Peter K. Day,
Anthony D. Turner,
Byeong Ho Eom,
Sunil Golwala,
David C. Moore,
Omid Noroozian,
Jonas Zmuidzinas,
Jiansong Gao,
Benjamin A. Mazin,
Sean McHugh,
Andrew Merrill
Abstract:
Titanium nitride (TiNx) films are ideal for use in superconducting microresonator detectors because: a) the critical temperature varies with composition (0 < Tc < 5 K); b) the normal-state resistivity is large, ρ_n ~ 100 $μ$Ohm cm, facilitating efficient photon absorption and providing a large kinetic inductance and detector responsivity; and c) TiN films are very hard and mechanically robust. Res…
▽ More
Titanium nitride (TiNx) films are ideal for use in superconducting microresonator detectors because: a) the critical temperature varies with composition (0 < Tc < 5 K); b) the normal-state resistivity is large, ρ_n ~ 100 $μ$Ohm cm, facilitating efficient photon absorption and providing a large kinetic inductance and detector responsivity; and c) TiN films are very hard and mechanically robust. Resonators using reactively sputtered TiN films show remarkably low loss (Q_i > 10^7) and have noise properties similar to resonators made using other materials, while the quasiparticle lifetimes are reasonably long, 10-200 $μ$s. TiN microresonators should therefore reach sensitivities well below 10^-19 WHz^(-1/2).
△ Less
Submitted 9 August, 2010; v1 submitted 29 March, 2010;
originally announced March 2010.
-
A semi-empirical model for two-level system noise in superconducting microresonators
Authors:
Jiansong Gao,
Miguel Daal,
John M. Martinis,
Benjamin A. Mazin,
Peter K. Day,
Henry G. Leduc,
Anastasios Vayonakis,
Bernard Sadoulet,
Jonas Zmuidzinas
Abstract:
We present measurements of the low--temperature excess frequency noise of four niobium superconducting coplanar waveguide microresonators, with center strip widths $s_r$ ranging from 3 $μ$m to 20 $μ$m. For a fixed internal power, we find that the frequency noise decreases rapidly with increasing center strip width, scaling as $1/s_r^{1.6}$. We show that this geometrical scaling is readily explai…
▽ More
We present measurements of the low--temperature excess frequency noise of four niobium superconducting coplanar waveguide microresonators, with center strip widths $s_r$ ranging from 3 $μ$m to 20 $μ$m. For a fixed internal power, we find that the frequency noise decreases rapidly with increasing center strip width, scaling as $1/s_r^{1.6}$. We show that this geometrical scaling is readily explained by a simple semi-empirical model which assumes a surface distribution of independent two-level system fluctuators. These results allow the resonator geometry to be optimized for minimum noise.
△ Less
Submitted 3 April, 2008;
originally announced April 2008.
-
Temperature Dependence of the Frequency and Noise of Superconducting Coplanar Waveguide Resonators
Authors:
Shwetank Kumar,
Jiansong Gao,
Jonas Zmuidzinas,
Benjamin A. Mazin,
Henry G. LeDuc,
Peter K. Day
Abstract:
We present measurements of the temperature and power dependence of the resonance frequency and frequency noise of superconducting niobium thin-film coplanar waveguide resonators, carried out at temperatures well below the superconducting transition (T_{c}=9.2 K). The noise decreases by nearly two orders of magnitude as the temperature is increased from 120 to 1200 mK, while the variation of the…
▽ More
We present measurements of the temperature and power dependence of the resonance frequency and frequency noise of superconducting niobium thin-film coplanar waveguide resonators, carried out at temperatures well below the superconducting transition (T_{c}=9.2 K). The noise decreases by nearly two orders of magnitude as the temperature is increased from 120 to 1200 mK, while the variation of the resonance frequency with temperature over this range agrees well with the standard two-level system (TLS) model for amorphous dielectrics. These results support the hypothesis that TLS are responsible for the noise in superconducting microresonators, and have important implications for resonator applications such as qubits and photon detectors.
△ Less
Submitted 28 February, 2008;
originally announced February 2008.
-
A Position Sensitive X-ray Spectrophotometer using Microwave Kinetic Inductance Detectors
Authors:
Benjamin A. Mazin,
Megan E. Eckart,
Bruce Bumble,
Sunil Golwala,
Peter K. Day,
Jonas Zmuidzinas,
Fiona A. Harrison
Abstract:
The surface impedance of a superconductor changes when energy is absorbed and Cooper pairs are broken to produce single electron (quasiparticle) excitations. This change may be sensitively measured using a thin-film resonant circuit called a microwave kinetic inductance detector (MKID). The practical application of MKIDs for photon detection requires a method of efficiently coupling the photon e…
▽ More
The surface impedance of a superconductor changes when energy is absorbed and Cooper pairs are broken to produce single electron (quasiparticle) excitations. This change may be sensitively measured using a thin-film resonant circuit called a microwave kinetic inductance detector (MKID). The practical application of MKIDs for photon detection requires a method of efficiently coupling the photon energy to the MKID. We present results on position sensitive X-ray detectors made by using two aluminum MKIDs on either side of a tantalum photon absorber strip. Diffusion constants, recombination times, and energy resolution are reported. MKIDs can easily be scaled into large arrays.
△ Less
Submitted 4 October, 2006;
originally announced October 2006.
-
Noise Properties of Superconducting Coplanar Waveguide Microwave Resonators
Authors:
Jiansong Gao,
Benjamin A. Mazin,
Peter K. Day,
Jonas Zmuidzinas,
Henry G. LeDuc
Abstract:
We have measured noise in thin-film superconducting coplanar waveguide resonators. This noise appears entirely as phase noise, equivalent to a jitter of the resonance frequency. In contrast, amplitude fluctuations are not observed at the sensitivity of our measurement. The ratio between the noise power in the phase and amplitude directions is large, in excess of 30 dB. These results have importa…
▽ More
We have measured noise in thin-film superconducting coplanar waveguide resonators. This noise appears entirely as phase noise, equivalent to a jitter of the resonance frequency. In contrast, amplitude fluctuations are not observed at the sensitivity of our measurement. The ratio between the noise power in the phase and amplitude directions is large, in excess of 30 dB. These results have important implications for resonant readouts of various devices such as detectors, amplifiers, and qubits. We suggest that the phase noise is due to two-level systems in dielectric materials.
△ Less
Submitted 2 February, 2007; v1 submitted 24 September, 2006;
originally announced September 2006.