-
Is Lindblad for me?
Authors:
Martino Stefanini,
Aleksandra A. Ziolkowska,
Dmitry Budker,
Ulrich Poschinger,
Ferdinand Schmidt-Kaler,
Antoine Browaeys,
Atac Imamoglu,
Darrick Chang,
Jamir Marino
Abstract:
The Lindblad master equation is a foundational tool for modeling the dynamics of open quantum systems. As its use has extended far beyond its original domain, the boundaries of its validity have grown opaque. In particular, the rise of new research areas including open quantum many-body systems, non-equilibrium condensed matter, and the possibility to test its limits in driven-open quantum simulat…
▽ More
The Lindblad master equation is a foundational tool for modeling the dynamics of open quantum systems. As its use has extended far beyond its original domain, the boundaries of its validity have grown opaque. In particular, the rise of new research areas including open quantum many-body systems, non-equilibrium condensed matter, and the possibility to test its limits in driven-open quantum simulators, call for a critical revision of its regimes of applicability. In this pedagogical review, we re-examine the folklore surrounding its three standard approximations (Born, Markov, and Rotating Wave Approximation), as we build our narrative by employing a series of examples and case studies accessible to any reader with a solid background on the fundamentals of quantum mechanics. As a synthesis of our work, we offer a checklist that contrasts common lore with refined expectations, offering a practical guideline for assessing the breakdown of the Lindblad framework in the problem at hand.
△ Less
Submitted 27 June, 2025;
originally announced June 2025.
-
Study of NbN as superconducting material for the usage in superconducting radio frequency cavities
Authors:
Kristof Schmieden,
Tim Schneemann,
Matthias Schott,
Malavika Unni,
Hendrik Bekker,
Arne Wickenbrock,
Dmitry Budker
Abstract:
A new axion-haloscope is setup at the Johannes Gutenberg university of Mainz, named the Supax (a SUPerconducting AXion search) experiment. This setup is used to characterize the behaviour of a NbN coated superconducting cavity in a 2.5T strong magnetic field, at a resonance frequency of 8.4GHz. We observe an increasing surface resistance with increasing magnetic field, leading to a decreasing qual…
▽ More
A new axion-haloscope is setup at the Johannes Gutenberg university of Mainz, named the Supax (a SUPerconducting AXion search) experiment. This setup is used to characterize the behaviour of a NbN coated superconducting cavity in a 2.5T strong magnetic field, at a resonance frequency of 8.4GHz. We observe an increasing surface resistance with increasing magnetic field, leading to a decreasing quality factor. The behaviour is similar to that of previously studied cavities using Nb3Tn.
△ Less
Submitted 19 December, 2024;
originally announced December 2024.
-
Ramsey interferometry of nuclear spins in diamond using stimulated Raman adiabatic passage
Authors:
Sean Lourette,
Andrey Jarmola,
Jabir Chathanathil,
Sebastián C. Carrasco,
Dmitry Budker,
Svetlana A. Malinovskaya,
A. Glen Birdwell,
Tony Ivanov,
Vladimir S. Malinovsky
Abstract:
We report the first experimental demonstration of stimulated Raman adiabatic passage (STIRAP) in nuclear-spin transitions of $^{14}$N within nitrogen-vacancy (NV) color centers in diamond. It is shown that the STIRAP technique suppresses the occupation of the intermediate state, which is a crucial factor for improvements in quantum sensing technology. Building on that advantage, we develop and imp…
▽ More
We report the first experimental demonstration of stimulated Raman adiabatic passage (STIRAP) in nuclear-spin transitions of $^{14}$N within nitrogen-vacancy (NV) color centers in diamond. It is shown that the STIRAP technique suppresses the occupation of the intermediate state, which is a crucial factor for improvements in quantum sensing technology. Building on that advantage, we develop and implement a generalized version of the Ramsey interferometric scheme, employing half-STIRAP pulses to perform the necessary quantum-state manipulation with high fidelity. The enhanced robustness of the STIRAP-based Ramsey scheme to variations in the pulse parameters is experimentally demonstrated, showing good agreement with theoretical predictions. Our results pave the way for improving the long-term stability of diamond-based sensors, such as gyroscopes and frequency standards.
△ Less
Submitted 22 July, 2024;
originally announced July 2024.
-
Near-zero-field microwave-free magnetometry with nitrogen-vacancy centers in nanodiamonds
Authors:
Omkar Dhungel,
Mariusz Mrózek,
Till Lenz,
Viktor Ivády,
Adam Gali,
Arne Wickenbrock,
Dmitry Budker,
Wojciech Gawlik,
Adam M. Wojciechowski
Abstract:
We study the fluorescence of nanodiamond ensembles as a function of static external magnetic field and observe characteristic dip features close to the zero field with potential for magnetometry applications. We analyze the dependence of the features width and contrast of the feature on the size of the diamond (in the range 30 nm to 3 um) and on the strength of a bias magnetic field applied transv…
▽ More
We study the fluorescence of nanodiamond ensembles as a function of static external magnetic field and observe characteristic dip features close to the zero field with potential for magnetometry applications. We analyze the dependence of the features width and contrast of the feature on the size of the diamond (in the range 30 nm to 3 um) and on the strength of a bias magnetic field applied transversely to the field being scanned. We also perform optically detected magnetic resonance (ODMR) measurements to quantify the strain splitting of the zero-field ODMR resonance across various nanodiamond sizes and compare it with the width and contrast measurements of the zero-field fluorescence features for both nanodiamonds and bulk samples. The observed properties provide compelling evidence of cross-relaxation effects in the NV system occurring close to zero magnetic fields. Finally, the potential of this technique for use in practical magnetometry is discussed.
△ Less
Submitted 6 February, 2024; v1 submitted 16 January, 2024;
originally announced January 2024.
-
Electric Charging Effects on Insulating Surfaces in Cryogenic Liquids
Authors:
Wolfgang Korsch,
Mark Broering,
Ashok Timsina,
Kent K. H. Leung,
Joshua Abney,
Dmitry Budker,
Bradley W. Filippone,
Jiachen He,
Suman Kandu,
Mark McCrea,
Murchhana Roy,
Christopher Swank,
Weijun Yao
Abstract:
This paper presents a new technique to study the adsorption and desorption of ions and electrons on insulating surfaces in the presence of strong electric fields in cryoliquids. The experimental design consists of a compact cryostat coupled with a sensitive electro-optical Kerr device to monitor the stability of the electric fields. The behavior of nitrogen and helium ions on a poly(methyl methacr…
▽ More
This paper presents a new technique to study the adsorption and desorption of ions and electrons on insulating surfaces in the presence of strong electric fields in cryoliquids. The experimental design consists of a compact cryostat coupled with a sensitive electro-optical Kerr device to monitor the stability of the electric fields. The behavior of nitrogen and helium ions on a poly(methyl methacrylate) (PMMA) surface was compared to a PMMA surface coated with a mixture of deuterated polystyrene and deuterated polybutadiene. Ion accumulation and removal on these surfaces were unambiguously observed. Within the precision of the data, both surfaces behave similarly for the physisorbed ions. The setup was also used to measure the (quasi-)static dielectric constant of PMMA at T = 70 K. The impact of the ion adsorption on the search for a neutron permanent electric dipole moment in a cryogenic environment, like the nEDM@SNS experiment, is discussed.
△ Less
Submitted 31 December, 2023;
originally announced January 2024.
-
Microwave-free wide-field magnetometry using nitrogen-vacancy centers
Authors:
Joseph Shaji Rebeirro,
Muhib Omar,
Till Lenz,
Omkar Dhungel,
Peter Blümler,
Dmitry Budker,
Arne Wickenbrock
Abstract:
A wide-field magnetometer utilizing nitrogen-vacancy (NV) centers in diamond that does not require microwaves is demonstrated. It is designed for applications where microwaves need to be avoided, such as magnetic imaging of biological or conductive samples. The system exploits a magnetically sensitive feature of NV centers near the ground state level anticrossing (GSLAC). An applied test field fro…
▽ More
A wide-field magnetometer utilizing nitrogen-vacancy (NV) centers in diamond that does not require microwaves is demonstrated. It is designed for applications where microwaves need to be avoided, such as magnetic imaging of biological or conductive samples. The system exploits a magnetically sensitive feature of NV centers near the ground state level anticrossing (GSLAC). An applied test field from a wire was mapped over an imaging area of $\approx 500 \times 470\,μ\text{m}^2$. Analysis of the GSLAC lineshape allows to extract vector information of the applied field. The device allows micrometer-scale magnetic imaging at a spatial resolution dominated by the thickness of the NV layer (here $50\,μ\text{m}$). For a pixel size of $4\,μ\text{m} \times 3.8\,μ\text{m}$ the estimated sensitivity is $4.8\,μ\text{T}/\sqrt{\text{Hz}}$. Two modalities for visualizing the magnetic fields, static and temporal, are presented along with a discussion of technical limitations and future extensions of the method.
△ Less
Submitted 25 October, 2023;
originally announced October 2023.
-
Near zero-field microwave-free magnetometry with ensembles of nitrogen-vacancy centers in diamond
Authors:
Omkar Dhungel,
Till Lenz,
Muhib Omar,
Joseph Shaji Rebeirro,
Minh-Tuan Luu,
Ali Tayefeh Younesi,
Ronald Ulbricht,
Viktor Ivady,
Adam Gali,
Arne Wickenbrock,
Dmitry Budker
Abstract:
We study cross-relaxation features near zero magnetic field with ensembles of nitrogen-vacancy (NV) centers in diamond and examine their properties in samples with a range (0.9 ppm - 16.0 ppm) of NV concentrations. The observed NV-NV cross-relaxation features between differently oriented NV centers in high (greater than 0.9 ppm)-NV-density samples hold promise for a variety of magnetometry applica…
▽ More
We study cross-relaxation features near zero magnetic field with ensembles of nitrogen-vacancy (NV) centers in diamond and examine their properties in samples with a range (0.9 ppm - 16.0 ppm) of NV concentrations. The observed NV-NV cross-relaxation features between differently oriented NV centers in high (greater than 0.9 ppm)-NV-density samples hold promise for a variety of magnetometry applications where microwave fields (or any bias field) disturb the system under study. We theoretically determine the values of the bias magnetic fields corresponding to cross-relaxations between different axes and experimentally validate them. The behavior of zero-field cross-relaxation features as a function of temperature is also investigated.
△ Less
Submitted 30 May, 2024; v1 submitted 23 January, 2023;
originally announced January 2023.
-
Scalar dark matter induced oscillation of permanent-magnet field
Authors:
I. M. Bloch,
D. Budker,
V. V. Flambaum,
I. B. Samsonov,
A. O. Sushkov,
O. Tretiak
Abstract:
Scalar-field dark matter models imply small oscillations of fundamental constants. These oscillations could result in observable variations of the magnetic field in a permanent magnet. We propose an experiment for detection of this type of dark matter through searches of oscillations of magnetic field of permanent magnets with a SQUID magnetometer or a low-noise radiofrequency amplifier. We show t…
▽ More
Scalar-field dark matter models imply small oscillations of fundamental constants. These oscillations could result in observable variations of the magnetic field in a permanent magnet. We propose an experiment for detection of this type of dark matter through searches of oscillations of magnetic field of permanent magnets with a SQUID magnetometer or a low-noise radiofrequency amplifier. We show that this experiment may have comparable sensitivity to leading experiments searching for variations of fundamental constants in the range of frequencies from a few Hz to about 1 MHz. We also discuss applicability of the approach of variations of fundamental constants for accounting for the interaction with scalar dark matter.
△ Less
Submitted 28 January, 2023; v1 submitted 20 January, 2023;
originally announced January 2023.
-
Temperature Sensitivity of $^{14}\mathrm{NV}$ and $^{15}\mathrm{NV}$ Ground State Manifolds
Authors:
Sean Lourette,
Andrey Jarmola,
Victor M. Acosta,
A. Glen Birdwell,
Dmitry Budker,
Marcus W. Doherty,
Tony Ivanov,
Vladimir S. Malinovsky
Abstract:
We measure electron and nuclear spin transition frequencies in the ground state of nitrogen-vacancy (NV) centers in diamond for two nitrogen isotopes ($^{14}\mathrm{NV}$ and $^{15}\mathrm{NV}$) over temperatures ranging from 77 K to 400 K. Measurements are performed using Ramsey interferometry and direct optical readout of the nuclear and electron spins. We extract coupling parameters $Q$ (for…
▽ More
We measure electron and nuclear spin transition frequencies in the ground state of nitrogen-vacancy (NV) centers in diamond for two nitrogen isotopes ($^{14}\mathrm{NV}$ and $^{15}\mathrm{NV}$) over temperatures ranging from 77 K to 400 K. Measurements are performed using Ramsey interferometry and direct optical readout of the nuclear and electron spins. We extract coupling parameters $Q$ (for $^{14}\mathrm{NV}$), $D$, $A_{||}$, $A_{\perp}$, $γ_e/γ_n$, and their temperature dependences for both isotopes. The temperature dependences of the nuclear-spin transitions within the $m_s = 0$ spin manifold near room temperature are found to be +0.52(1) ppm/K for $^{14}\mathrm{NV}$ ($|m_I=-1> \leftrightarrow |m_I=+1>$) and -1.1(1) ppm/K for $^{15}\mathrm{NV}$ ($|m_I=-1/2> \leftrightarrow |m_I=+1/2>$). An isotopic shift in the zero-field splitting parameter $D$ between $^{14}\mathrm{NV}$ and $^{15}\mathrm{NV}$ is measured to be $\sim$ 120 kHz. Residual transverse magnetic fields are observed to shift the nuclear spin transition frequencies, especially for $^{15}\mathrm{NV}$. We have precisely determined the set of parameters relevant for the development of nuclear-spin-based diamond quantum sensors with greatly reduced sensitivity to environmental factors.
△ Less
Submitted 23 December, 2022;
originally announced December 2022.
-
Demonstration of diamond nuclear spin gyroscope
Authors:
Andrey Jarmola,
Sean Lourette,
Victor M. Acosta,
A. Glen Birdwell,
Peter Blümler,
Dmitry Budker,
Tony Ivanov,
Vladimir S. Malinovsky
Abstract:
We demonstrate operation of a rotation sensor based on the $^{14}$N nuclear spins intrinsic to nitrogen-vacancy (NV) color centers in diamond. The sensor employs optical polarization and readout of the nuclei and a radio-frequency double-quantum pulse protocol that monitors $^{14}$N nuclear spin precession. This measurement protocol suppresses the sensitivity to temperature variations in the…
▽ More
We demonstrate operation of a rotation sensor based on the $^{14}$N nuclear spins intrinsic to nitrogen-vacancy (NV) color centers in diamond. The sensor employs optical polarization and readout of the nuclei and a radio-frequency double-quantum pulse protocol that monitors $^{14}$N nuclear spin precession. This measurement protocol suppresses the sensitivity to temperature variations in the $^{14}$N quadrupole splitting, and it does not require microwave pulses resonant with the NV electron spin transitions. The device was tested on a rotation platform and demonstrated a sensitivity of 4.7 $^{\circ}/\sqrt{\rm{s}}$ (13 mHz/$\sqrt{\rm{Hz}}$), with bias stability of 0.4 $^{\circ}$/s (1.1 mHz).
△ Less
Submitted 9 July, 2021;
originally announced July 2021.
-
Emergent hydrodynamics in a strongly interacting dipolar spin ensemble
Authors:
Chong Zu,
Francisco Machado,
Bingtian Ye,
Soonwon Choi,
Bryce Kobrin,
Thomas Mittiga,
Satcher Hsieh,
Prabudhya Bhattacharyya,
Matthew Markham,
Dan Twitchen,
Andrey Jarmola,
Dmitry Budker,
Chris R. Laumann,
Joel E. Moore,
Norman Y. Yao
Abstract:
Conventional wisdom holds that macroscopic classical phenomena naturally emerge from microscopic quantum laws. However, despite this mantra, building direct connections between these two descriptions has remained an enduring scientific challenge. In particular, it is difficult to quantitatively predict the emergent "classical" properties of a system (e.g. diffusivity, viscosity, compressibility) f…
▽ More
Conventional wisdom holds that macroscopic classical phenomena naturally emerge from microscopic quantum laws. However, despite this mantra, building direct connections between these two descriptions has remained an enduring scientific challenge. In particular, it is difficult to quantitatively predict the emergent "classical" properties of a system (e.g. diffusivity, viscosity, compressibility) from a generic microscopic quantum Hamiltonian. Here, we introduce a hybrid solid-state spin platform, where the underlying disordered, dipolar quantum Hamiltonian gives rise to the emergence of unconventional spin diffusion at nanometer length scales. In particular, the combination of positional disorder and on-site random fields leads to diffusive dynamics that are Fickian yet non-Gaussian. Finally, by tuning the underlying parameters within the spin Hamiltonian via a combination of static and driven fields, we demonstrate direct control over the emergent spin diffusion coefficient. Our work opens the door to investigating hydrodynamics in many-body quantum spin systems.
△ Less
Submitted 15 April, 2021;
originally announced April 2021.
-
Determination of local defect density in diamond by double electron-electron resonance
Authors:
Shang Li,
Huijie Zheng,
Zaili Peng,
Mizuki Kamiya,
Tomoyuki Niki,
Viktor Stepanov,
Andrey Jarmola,
Yasuhiro Shimizu,
Susumu Takahashi,
Arne Wickenbrock,
Dmitry Budker
Abstract:
Magnetic impurities in diamond influence the relaxation properties and thus limit the sensitivity of magnetic, electric, strain, and temperature sensors based on nitrogen-vacancy color centers. Diamond samples may exhibit significant spatial variations in the impurity concentrations hindering the quantitative analysis of relaxation pathways. Here, we present a local measurement technique which can…
▽ More
Magnetic impurities in diamond influence the relaxation properties and thus limit the sensitivity of magnetic, electric, strain, and temperature sensors based on nitrogen-vacancy color centers. Diamond samples may exhibit significant spatial variations in the impurity concentrations hindering the quantitative analysis of relaxation pathways. Here, we present a local measurement technique which can be used to determine the concentration of various species of defects by utilizing double electron-electron resonance. This method will help to improve the understanding of the physics underlying spin relaxation and guide the development of diamond samples, as well as offering protocols for optimized sensing.
△ Less
Submitted 1 April, 2021;
originally announced April 2021.
-
Quantum sensitivity limits of nuclear magnetic resonance experiments searching for new fundamental physics
Authors:
Deniz Aybas,
Hendrik Bekker,
John W. Blanchard,
Dmitry Budker,
Gary P. Centers,
Nataniel L. Figueroa,
Alexander V. Gramolin,
Derek F. Jackson Kimball,
Arne Wickenbrock,
Alexander O. Sushkov
Abstract:
Nuclear magnetic resonance is a promising experimental approach to search for ultra-light axion-like dark matter. Searches such as the cosmic axion spin-precession experiments (CASPEr) are ultimately limited by quantum-mechanical noise sources, in particular, spin-projection noise. We discuss how such fundamental limits can potentially be reached. We consider a circuit model of a magnetic resonanc…
▽ More
Nuclear magnetic resonance is a promising experimental approach to search for ultra-light axion-like dark matter. Searches such as the cosmic axion spin-precession experiments (CASPEr) are ultimately limited by quantum-mechanical noise sources, in particular, spin-projection noise. We discuss how such fundamental limits can potentially be reached. We consider a circuit model of a magnetic resonance experiment and quantify three noise sources: spin-projection noise, thermal noise, and amplifier noise. Calculation of the total noise spectrum takes into account the modification of the circuit impedance by the presence of nuclear spins, as well as the circuit back-action on the spin ensemble. Suppression of the circuit back-action is especially important in order for the spin-projection noise limits of searches for axion-like dark matter to reach the quantum chromodynamic axion sensitivity.
△ Less
Submitted 10 March, 2021;
originally announced March 2021.
-
Search for axion-like dark matter using solid-state nuclear magnetic resonance
Authors:
Deniz Aybas,
Janos Adam,
Emmy Blumenthal,
Alexander V. Gramolin,
Dorian Johnson,
Annalies Kleyheeg,
Samer Afach,
John W. Blanchard,
Gary P. Centers,
Antoine Garcon,
Martin Engler,
Nataniel L. Figueroa,
Marina Gil Sendra,
Arne Wickenbrock,
Matthew Lawson,
Tao Wang,
Teng Wu,
Haosu Luo,
Hamdi Mani,
Philip Mauskopf,
Peter W. Graham,
Surjeet Rajendran,
Derek F. Jackson Kimball,
Dmitry Budker,
Alexander O. Sushkov
Abstract:
We report the results of an experimental search for ultralight axion-like dark matter in the mass range 162 neV to 166 neV. The detection scheme of our Cosmic Axion Spin Precession Experiment (CASPEr) is based on a precision measurement of $^{207}$Pb solid-state nuclear magnetic resonance in a polarized ferroelectric crystal. Axion-like dark matter can exert an oscillating torque on $^{207}$Pb nuc…
▽ More
We report the results of an experimental search for ultralight axion-like dark matter in the mass range 162 neV to 166 neV. The detection scheme of our Cosmic Axion Spin Precession Experiment (CASPEr) is based on a precision measurement of $^{207}$Pb solid-state nuclear magnetic resonance in a polarized ferroelectric crystal. Axion-like dark matter can exert an oscillating torque on $^{207}$Pb nuclear spins via the electric-dipole moment coupling $g_d$, or via the gradient coupling $g_{\text{aNN}}$. We calibrated the detector and characterized the excitation spectrum and relaxation parameters of the nuclear spin ensemble with pulsed magnetic resonance measurements in a 4.4 T magnetic field. We swept the magnetic field near this value and searched for axion-like dark matter with Compton frequency within a 1 MHz band centered at 39.65 MHz. Our measurements place the upper bounds $|g_d|<9.5\times10^{-4}\,\text{GeV}^{-2}$ and $|g_{\text{aNN}}|<2.8\times10^{-1}\,\text{GeV}^{-1}$ (95% confidence level) in this frequency range. The constraint on $g_d$ corresponds to an upper bound of $1.0\times 10^{-21}\,\text{e}\cdot\text{cm}$ on the amplitude of oscillations of the neutron electric dipole moment, and $4.3\times 10^{-6}$ on the amplitude of oscillations of CP-violating $θ$ parameter of quantum chromodynamics. Our results demonstrate the feasibility of using solid-state nuclear magnetic resonance to search for axion-like dark matter in the nano-electronvolt mass range.
△ Less
Submitted 12 March, 2021; v1 submitted 4 January, 2021;
originally announced January 2021.
-
Ferromagnetic Gyroscopes for Tests of Fundamental Physics
Authors:
Pavel Fadeev,
Chris Timberlake,
Tao Wang,
Andrea Vinante,
Y. B. Band,
Dmitry Budker,
Alexander O. Sushkov,
Hendrik Ulbricht,
Derek F. Jackson Kimball
Abstract:
A ferromagnetic gyroscope (FG) is a ferromagnet whose angular momentum is dominated by electron spin polarization and that will precess under the action of an external torque, such as that due to a magnetic field. Here we model and analyze FG dynamics and sensitivity, focusing on practical schemes for experimental realization. In the case of a freely floating FG, we model the transition from dynam…
▽ More
A ferromagnetic gyroscope (FG) is a ferromagnet whose angular momentum is dominated by electron spin polarization and that will precess under the action of an external torque, such as that due to a magnetic field. Here we model and analyze FG dynamics and sensitivity, focusing on practical schemes for experimental realization. In the case of a freely floating FG, we model the transition from dynamics dominated by libration in relatively high externally applied magnetic fields, to those dominated by precession at relatively low applied fields. Measurement of the libration frequency enables in situ measurement of the magnetic field and a technique to reduce the field below the threshold for which precession dominates the FG dynamics. We note that evidence of gyroscopic behavior is present even at magnetic fields much larger than the threshold field below which precession dominates. We also model the dynamics of an FG levitated above a type-I superconductor via the Meissner effect, and find that for FGs with dimensions larger than about 100 nm the observed precession frequency is reduced compared to that of a freely floating FG. This is akin to negative feedback that arises from the distortion of the field from the FG by the superconductor. Finally we assess the sensitivity of an FG levitated above a type-I superconductor to exotic spin-dependent interactions under practical experimental conditions, demonstrating the potential of FGs for tests of fundamental physics.
△ Less
Submitted 17 October, 2020;
originally announced October 2020.
-
Probing topological spin structures using light-polarization and magnetic microscopy
Authors:
Till Lenz,
Georgios Chatzidrosos,
Zhiyuan Wang,
Lykourgos Bougas,
Yannick Dumeige,
Arne Wickenbrock,
Nico Kerber,
Jakub Zázvorka,
Fabian Kammerbauer,
Mathias Kläui,
Zeeshawn Kazi,
Kai-Mei C. Fu,
Kohei Itoh,
Hideyuki Watanabe,
Dmitry Budker
Abstract:
We present an imaging modality that enables detection of magnetic moments and their resulting stray magnetic fields. We use wide-field magnetic imaging that employs a diamond-based magnetometer and has combined magneto-optic detection (e.g. magneto-optic Kerr effect) capabilities. We employ such an instrument to image magnetic (stripe) domains in multilayered ferromagnetic structures.
We present an imaging modality that enables detection of magnetic moments and their resulting stray magnetic fields. We use wide-field magnetic imaging that employs a diamond-based magnetometer and has combined magneto-optic detection (e.g. magneto-optic Kerr effect) capabilities. We employ such an instrument to image magnetic (stripe) domains in multilayered ferromagnetic structures.
△ Less
Submitted 7 October, 2020;
originally announced October 2020.
-
Cross-relaxation studies with optically detected magnetic resonances in nitrogen-vacancy centers in diamond in an external magnetic field
Authors:
Reinis Lazda,
Laima Busaite,
Andris Berzins,
Janis Smits,
Marcis Auzinsh,
Dmitry Budker,
Ruvin Ferber,
Florian Gahbauer
Abstract:
In this paper cross-relaxation between nitrogen-vacancy (NV) centers and substitutional nitrogen in a diamond crystal was studied. It was demonstrated that optically detected magnetic resonance signals (ODMR) can be used to measure these signals successfully. The ODMR were detected at axial magnetic field values around 51.2~mT in a diamond sample with a relatively high (200~ppm) nitrogen concentra…
▽ More
In this paper cross-relaxation between nitrogen-vacancy (NV) centers and substitutional nitrogen in a diamond crystal was studied. It was demonstrated that optically detected magnetic resonance signals (ODMR) can be used to measure these signals successfully. The ODMR were detected at axial magnetic field values around 51.2~mT in a diamond sample with a relatively high (200~ppm) nitrogen concentration. We observed transitions that involve magnetic sublevels that are split by the hyperfine interaction. Microwaves in the frequency ranges from 1.3 GHz to 1.6 GHz ($m_S=0\longrightarrow m_S=-1$ NV transitions) and from 4.1 to 4.6 GHz ($m_S=0\longrightarrow m_S=+1$ NV transitions) were used.
To understand the cross-relaxation process in more detail and, as a result, reproduce measured signals more accurately, a model was developed that describes the microwave-initiated transitions between hyperfine levels of the NV center that are undergoing anti-crossing and are strongly mixed in the applied magnetic field. Additionally, we simulated the extent to which the microwave radiation used to induce ODMR in the NV center also induced transitions in the substitutional nitrogen via cross-relaxation.
The improved understanding of the NV processes in the presence of a magnetic field will be useful for designing NV-diamond-based devices for a wide range of applications from implementation of q-bits to hyperpolarization of large molecules to various quantum technological applications such as field sensors.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
Photoluminescence at the ground state level anticrossing of the nitrogen-vacancy center in diamond
Authors:
Viktor Ivády,
Huijie Zheng,
Arne Wickenbrock,
Lykourgos Bougas,
Georgios Chatzidrosos,
Kazuo Nakamura,
Hitoshi Sumiya,
Takeshi Ohshima,
Junichi Isoya,
Dmitry Budker,
Igor A. Abrikosov,
Adam Gali
Abstract:
The nitrogen-vacancy center (NV center) in diamond at magnetic fields corresponding to the ground state level anticrossing (GSLAC) region gives rise to rich photoluminescence (PL) signals due to the vanishing energy gap between the electron spin states, which enables to have an effect on the NV center's luminescence for a broad variety of environmental couplings. In this article we report on the G…
▽ More
The nitrogen-vacancy center (NV center) in diamond at magnetic fields corresponding to the ground state level anticrossing (GSLAC) region gives rise to rich photoluminescence (PL) signals due to the vanishing energy gap between the electron spin states, which enables to have an effect on the NV center's luminescence for a broad variety of environmental couplings. In this article we report on the GSLAC photoluminescence signature of NV ensembles in different spin environments at various external fields. We investigate the effects of transverse electric and magnetic fields, P1 centers, NV centers, and the $^{13}$C nuclear spins, each of which gives rise to a unique PL signature at the GSLAC. The comprehensive analysis of the couplings and related optical signal at the GSLAC provides a solid ground for advancing various microwave-free applications at the GSLAC, including but not limited to magnetometry, spectroscopy, dynamic nuclear polarization (DNP), and nuclear magnetic resonance (NMR) detection. We demonstrate that not only the most abundant $^{14}$NV center but the $^{15}$NV can also be utilized in such applications and that nuclear spins coupled to P1 centers can be polarized directly by the NV center at the GSLAC, through a giant effective nuclear $g$-factor arising from the NV center-P1 center-nuclear spin coupling. We report on new alternative for measuring defect concentration in the vicinity of NV centers and on the optical signatures of interacting, mutually aligned NV centers.
△ Less
Submitted 19 June, 2020; v1 submitted 9 June, 2020;
originally announced June 2020.
-
Optically Enhanced Electric Field Sensing Using Nitrogen-Vacancy Ensembles
Authors:
M. Block,
B. Kobrin,
A. Jarmola,
S. Hsieh,
C. Zu,
N. L. Figueroa,
V. M. Acosta,
J. Minguzzi,
J. R. Maze,
D. Budker,
N. Y. Yao
Abstract:
Nitrogen-vacancy (NV) centers in diamond have shown promise as inherently localized electric-field sensors, capable of detecting individual charges with nanometer resolution. Working with NV ensembles, we demonstrate that a detailed understanding of the internal electric field environment enables enhanced sensitivity in the detection of external electric fields. We follow this logic along two comp…
▽ More
Nitrogen-vacancy (NV) centers in diamond have shown promise as inherently localized electric-field sensors, capable of detecting individual charges with nanometer resolution. Working with NV ensembles, we demonstrate that a detailed understanding of the internal electric field environment enables enhanced sensitivity in the detection of external electric fields. We follow this logic along two complementary paths. First, using excitation tuned near the NV's zero-phonon line, we perform optically detected magnetic resonance (ODMR) spectroscopy at cryogenic temperatures in order to precisely measure the NV center's excited-state susceptibility to electric fields. In doing so, we demonstrate that the characteristically observed contrast inversion arises from an interplay between spin-selective optical pumping and the NV centers' local charge distribution. Second, motivated by this understanding, we propose and analyze a novel scheme for optically-enhanced electric-field sensing using NV ensembles; we estimate that our approach should enable order of magnitude improvements in the DC electric-field sensitivity.
△ Less
Submitted 26 September, 2021; v1 submitted 6 April, 2020;
originally announced April 2020.
-
Erwin L. Hahn: A Biographical Memoir
Authors:
Alexander Pines,
Dmitry Budker
Abstract:
Erwin Louis Hahn was one of the most innovative and influential physical scientists in recent history, impacting generations of scientists through his work in nuclear magnetic resonance (NMR), optics, and the intersection of these two fields. Starting with his discovery of the spin echo, a phenomenon of monumental significance and practical importance, Hahn launched a major revolution in how we th…
▽ More
Erwin Louis Hahn was one of the most innovative and influential physical scientists in recent history, impacting generations of scientists through his work in nuclear magnetic resonance (NMR), optics, and the intersection of these two fields. Starting with his discovery of the spin echo, a phenomenon of monumental significance and practical importance, Hahn launched a major revolution in how we think about spin physics, with numerous implications to follow in many other areas of science. Students of NMR and coherent optics quickly discover that many of the key concepts and techniques in these fields derive directly from his work.
△ Less
Submitted 8 June, 2019;
originally announced June 2019.
-
Extreme nuclear magnetic resonance: zero field, single spins, dark matter...
Authors:
Dmitry Budker
Abstract:
An unusual regime for liquid-state nuclear magnetic resonance (NMR) where the magnetic field strength is so low that the $J$-coupling (intramolecular spin-spin) interactions dominate the spin Hamiltonian opens a new paradigm with applications in spectroscopy, quantum control, and in fundamental-physics experiments, including searches for well-motivated dark-matter candidates. An interesting possib…
▽ More
An unusual regime for liquid-state nuclear magnetic resonance (NMR) where the magnetic field strength is so low that the $J$-coupling (intramolecular spin-spin) interactions dominate the spin Hamiltonian opens a new paradigm with applications in spectroscopy, quantum control, and in fundamental-physics experiments, including searches for well-motivated dark-matter candidates. An interesting possibility is to bring this kind of "extreme NMR" together with another one---single nuclear spin detected with a single-spin quantum sensor. This would enable single-molecule $J$-spectroscopy.
△ Less
Submitted 21 May, 2019;
originally announced May 2019.
-
Microwave-free vector magnetometry with nitrogen-vacancy centers along a single axis in diamond
Authors:
Huijie Zheng,
Zhiyin Sun,
Georgios Chatzidrosos,
Chen Zhang,
Kazuo Nakamura,
Hitoshi Sumiya,
Takeshi Ohshima,
Junichi Isoya,
Jörg Wrachtrup,
Arne Wickenbrock,
Dmitry Budker
Abstract:
Sensing vector magnetic fields is critical to many applications in fundamental physics, bioimaging, and material science. Magnetic-field sensors exploiting nitrogen-vacancy (NV) centers are particularly compelling as they offer high sensitivity and spatial resolution even at nanoscale. Achieving vector magnetometry has, however, often required applying microwaves sequentially or simultaneously, li…
▽ More
Sensing vector magnetic fields is critical to many applications in fundamental physics, bioimaging, and material science. Magnetic-field sensors exploiting nitrogen-vacancy (NV) centers are particularly compelling as they offer high sensitivity and spatial resolution even at nanoscale. Achieving vector magnetometry has, however, often required applying microwaves sequentially or simultaneously, limiting the sensors' applications under cryogenic temperature. Here we propose and demonstrate a microwave-free vector magnetometer that simultaneously measures all Cartesian components of a magnetic field using NV ensembles in diamond. In particular, the present magnetometer leverages the level anticrossing in the triplet ground state at 102.4 mT, allowing the measurement of both longitudinal and transverse fields with a wide bandwidth from zero to megahertz range. Full vector sensing capability is proffered by modulating fields along the preferential NV axis and in the transverse plane and subsequent demodulation of the signal. This sensor exhibits a root mean square noise floor of about 300 pT/Hz^(1/2) in all directions. The present technique is broadly applicable to both ensemble sensors and potentially also single-NV sensors, extending the vector capability to nanoscale measurement under ambient temperatures.
△ Less
Submitted 14 April, 2020; v1 submitted 8 April, 2019;
originally announced April 2019.
-
Dynamics of a Ferromagnetic Particle Levitated Over a Superconductor
Authors:
Tao Wang,
Sean Lourette,
Sean R. O Kelley,
Metin Kayci,
Y. B. Band,
Derek F. Jackson Kimball,
Alexander O. Sushkov,
Dmitry Budker
Abstract:
Under conditions where the angular momentum of a ferromagnetic particle is dominated by intrinsic spin, applied torque is predicted to cause gyroscopic precession of the particle. If the particle is sufficiently isolated from the environment, a measurement of spin precession can potentially yield sensitivity to torque beyond the standard quantum limit. Levitation of a micron-scale ferromagnetic pa…
▽ More
Under conditions where the angular momentum of a ferromagnetic particle is dominated by intrinsic spin, applied torque is predicted to cause gyroscopic precession of the particle. If the particle is sufficiently isolated from the environment, a measurement of spin precession can potentially yield sensitivity to torque beyond the standard quantum limit. Levitation of a micron-scale ferromagnetic particle above a superconductor is a possible method of near frictionless suspension enabling observation of ferromagnetic particle precession and ultrasensitive torque measurements. We experimentally investigate the dynamics of a micron-scale ferromagnetic particle levitated above a superconducting niobium surface. We find that the levitating particles are trapped in potential minima associated with residual magnetic flux pinned by the superconductor and, using an optical technique, characterize the quasiperiodic motion of the particles in these traps.
△ Less
Submitted 6 April, 2019; v1 submitted 19 October, 2018;
originally announced October 2018.
-
Sawtooth wave adiabatic passage slowing of dysprosium
Authors:
Niels Petersen,
Florian Mühlbauer,
Lykourgos Bougas,
Arijit Sharma,
Dmitry Budker,
Patrick Windpassinger
Abstract:
We report on sawtooth wave adiabatic passage (SWAP) slowing of bosonic and fermionic dysprosium isotopes by using a 136 kHz wide transition at 626 nm. A beam of precooled atoms is further decelerated in one dimension by the SWAP force and the amount of atoms at near zero velocity is measured. We demonstrate that the SWAP slowing can be twice as fast as in a conventional optical molasses operated o…
▽ More
We report on sawtooth wave adiabatic passage (SWAP) slowing of bosonic and fermionic dysprosium isotopes by using a 136 kHz wide transition at 626 nm. A beam of precooled atoms is further decelerated in one dimension by the SWAP force and the amount of atoms at near zero velocity is measured. We demonstrate that the SWAP slowing can be twice as fast as in a conventional optical molasses operated on the same transition. In addition, we investigate the parameter range for which the SWAP force is efficiently usable in our set-up, and relate the results to the adiabaticity condition. Furthermore, we add losses to the hyperfine ground-state population of fermionic dysprosium during deceleration and observe more robust slowing with SWAP compared to slowing with the radiation pressure force.
△ Less
Submitted 17 September, 2018;
originally announced September 2018.
-
Imaging the local charge environment of nitrogen-vacancy centers in diamond
Authors:
Thomas Mittiga,
Satcher Hsieh,
Chong Zu,
Bryce Kobrin,
Francisco Machado,
Prabudhya Bhattacharyya,
Nicholas Rui,
Andrey Jarmola,
Soonwon Choi,
Dmitry Budker,
Norman Y. Yao
Abstract:
Characterizing the local internal environment surrounding solid-state spin defects is crucial to harnessing them as nanoscale sensors of external fields. This is especially germane to the case of defect ensembles which can exhibit a complex interplay between interactions, internal fields and lattice strain. Working with the nitrogen-vacancy (NV) center in diamond, we demonstrate that local electri…
▽ More
Characterizing the local internal environment surrounding solid-state spin defects is crucial to harnessing them as nanoscale sensors of external fields. This is especially germane to the case of defect ensembles which can exhibit a complex interplay between interactions, internal fields and lattice strain. Working with the nitrogen-vacancy (NV) center in diamond, we demonstrate that local electric fields dominate the magnetic resonance behavior of NV ensembles at low magnetic field. We introduce a simple microscopic model that quantitatively captures the observed spectra for samples with NV concentrations spanning over two orders of magnitude. Motivated by this understanding, we propose and implement a novel method for the nanoscale localization of individual charges within the diamond lattice; our approach relies upon the fact that the charge induces an NV dark state which depends on the electric field orientation.
△ Less
Submitted 5 September, 2018;
originally announced September 2018.
-
Color centers in diamond as novel probes of superconductivity
Authors:
Victor M. Acosta,
Louis S. Bouchard,
Dmitry Budker,
Ron Folman,
Till Lenz,
Patrick Maletinsky,
Dominik Rohner,
Yechezkel Schlussel,
Lucas Thiel
Abstract:
Magnetic imaging using color centers in diamond through both scanning and wide-field methods offers a combination of unique capabilities for studying superconductivity, for example, enabling accurate vector magnetometry at high temperature or high pressure, with spatial resolution down to the nanometer scale. The paper briefly reviews various experimental modalities in this rapidly developing nasc…
▽ More
Magnetic imaging using color centers in diamond through both scanning and wide-field methods offers a combination of unique capabilities for studying superconductivity, for example, enabling accurate vector magnetometry at high temperature or high pressure, with spatial resolution down to the nanometer scale. The paper briefly reviews various experimental modalities in this rapidly developing nascent field and provides an outlook towards possible future directions.
△ Less
Submitted 9 August, 2018;
originally announced August 2018.
-
Hyperfine level structure in nitrogen-vacancy centers near the ground-state level anticrossing
Authors:
Marcis Auzinsh,
Andris Berzins,
Dmitry Budker,
Laima Busaite,
Ruvin Ferber,
Florian Gahbauer,
Reinis Lazda,
Arne Wickenbrock,
Huijie Zheng
Abstract:
Energy levels of nitrogen-vacancy centers in diamond were investigated using optically detected magnetic-resonance spectroscopy near the electronic ground-state level anticrossing (GSLAC) at an axial magnetic field around 102.4~mT in diamond samples with a nitrogen concentration of 1~ppm and 200~ppm. By applying radiowaves in the frequency ranges from 0 to 40 MHz and from 5.6 to 5.9 GHz, we observ…
▽ More
Energy levels of nitrogen-vacancy centers in diamond were investigated using optically detected magnetic-resonance spectroscopy near the electronic ground-state level anticrossing (GSLAC) at an axial magnetic field around 102.4~mT in diamond samples with a nitrogen concentration of 1~ppm and 200~ppm. By applying radiowaves in the frequency ranges from 0 to 40 MHz and from 5.6 to 5.9 GHz, we observed transitions that involve energy levels mixed by the hyperfine interaction. We developed a theoretical model that describes the level mixing, transition energies, and transition strengths between the ground-state sublevels, including the coupling to the nuclear spin of the NV center\textquotesingle s $^{14}$N and $^{13}$C atoms. The calculations were combined with the experimental results by fitting the ODMR spectral lines based on a theoretical model, which yielded information about the polarization of nuclear spins. This study is important for the optimization of experimental conditions in GSLAC-based applications, e.g., microwave-free magnetometry and microwave-free nuclear-magnetic-resonance probes.
△ Less
Submitted 22 August, 2019; v1 submitted 3 May, 2018;
originally announced May 2018.
-
Widefield imaging of superconductor vortices with electron spins in diamond
Authors:
Yechezkel Schlussel,
Till Lenz,
Dominik Rohner,
Yaniv Bar-Haim,
Lykourgos Bougas,
David Groswasser,
Michael Kieschnick,
Evgeny Rozenberg,
Lucas Thiel,
Amir Waxman,
Jan Meijer,
Patrick Maletinsky,
Dmitry Budker,
Ron Folman
Abstract:
Understanding the mechanisms behind high-$T_{c}$ Type-II superconductors (SC) is still an open task in condensed matter physics. One way to gain further insight into the microscopic mechanisms leading to superconductivity is to study the magnetic properties of the SC in detail, for example by studying the properties of vortices and their dynamics. In this work we describe a new method of wide-fiel…
▽ More
Understanding the mechanisms behind high-$T_{c}$ Type-II superconductors (SC) is still an open task in condensed matter physics. One way to gain further insight into the microscopic mechanisms leading to superconductivity is to study the magnetic properties of the SC in detail, for example by studying the properties of vortices and their dynamics. In this work we describe a new method of wide-field imaging magnetometry using nitrogen-vacancy (NV) centers in diamond to image vortices in an yttrium barium copper oxide (YBCO) thin film. We demonstrate quantitative determination of the magnetic field strength of the vortex stray field, the observation of vortex patterns for different cooling fields and direct observation of vortex pinning in our disordered YBCO film. This method opens prospects for imaging of the magnetic-stray fields of vortices at frequencies from DC to several megahertz within a wide range of temperatures which allows for the study of both high-$T_{C}$ and low-$T_{C}$ SCs. The wide temperature range allowed by NV center magnetometry also makes our approach applicable for the study of phenomena like island superconductivity at elevated temperatures (e.g. in metal nano-clusters).
△ Less
Submitted 5 March, 2018;
originally announced March 2018.
-
Spin-lattice relaxation of individual solid-state spins
Authors:
A. Norambuena,
E. Muñoz,
H. T. Dinani,
A. Jarmola,
P. Maletinsky,
D. Budker,
J. R. Maze
Abstract:
Understanding the effect of vibrations on the relaxation process of individual spins is crucial for implementing nano systems for quantum information and quantum metrology applications. In this work, we present a theoretical microscopic model to describe the spin-lattice relaxation of individual electronic spins associated to negatively charged nitrogen-vacancy centers in diamond, although our res…
▽ More
Understanding the effect of vibrations on the relaxation process of individual spins is crucial for implementing nano systems for quantum information and quantum metrology applications. In this work, we present a theoretical microscopic model to describe the spin-lattice relaxation of individual electronic spins associated to negatively charged nitrogen-vacancy centers in diamond, although our results can be extended to other spin-boson systems. Starting from a general spin-lattice interaction Hamiltonian, we provide a detailed description and solution of the quantum master equation of an electronic spin-one system coupled to a phononic bath in thermal equilibrium. Special attention is given to the dynamics of one-phonon processes below 1 K where our results agree with recent experimental findings and analytically describe the temperature and magnetic-field scaling. At higher temperatures, linear and second-order terms in the interaction Hamiltonian are considered and the temperature scaling is discussed for acoustic and quasi-localized phonons when appropriate. Our results, in addition to confirming a $T^5$ temperature dependence of the longitudinal relaxation rate at higher temperatures, in agreement with experimental observations, provide a theoretical background for modeling the spin-lattice relaxation at a wide range of temperatures where different temperature scalings might be expected.
△ Less
Submitted 28 November, 2017;
originally announced November 2017.
-
Spin ensemble-based AC magnetometry using concatenated dynamical decoupling at low temperatures
Authors:
D. Farfurnik,
A. Jarmola,
D. Budker,
N. Bar-Gill
Abstract:
Ensembles of nitrogen-vacancy (NV) centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10-250 kHz range, at room temperature and 77 K. By performin…
▽ More
Ensembles of nitrogen-vacancy (NV) centers in diamond are widely used as AC magnetometers. While such measurements are usually performed using standard (XY) dynamical decoupling (DD) protocols at room temperature, we study the sensitivities achieved by utilizing various DD protocols, for measuring magnetic AC fields at frequencies in the 10-250 kHz range, at room temperature and 77 K. By performing measurements on an isotopically pure $^{12}$C sample, we find that the Carr-Purcell-Meiboom-Gill (CPMG) protocol, which is not robust against pulse imperfections, is less efficient for magnetometry than robust XY-based sequences. The concatenation of a standard XY-based protocol may enhance the sensitivities only for measuring high-frequency fields, for which many ($> 500$) DD pulses are necessary and the robustness against pulse imperfections is critical. Moreover, we show that cooling is effective only for measuring low-frequency fields (~10 kHz), for which the experiment time apporaches $T_1$ at a small number of applied DD pulses.
△ Less
Submitted 12 December, 2017; v1 submitted 11 September, 2017;
originally announced September 2017.
-
Miniature cavity-enhanced diamond magnetometer
Authors:
Georgios Chatzidrosos,
Arne Wickenbrock,
Lykourgos Bougas,
Nathan Leefer,
Teng Wu,
Kasper Jensen,
Yannick Dumeige,
Dmitry Budker
Abstract:
We present a highly sensitive miniaturized cavity-enhanced room-temperature magnetic-field sensor based on nitrogen-vacancy (NV) centers in diamond. The magnetic resonance signal is detected by probing absorption on the 1042\,nm spin-singlet transition. To improve the absorptive signal the diamond is placed in an optical resonator. The device has a magnetic-field sensitivity of 28 pT/…
▽ More
We present a highly sensitive miniaturized cavity-enhanced room-temperature magnetic-field sensor based on nitrogen-vacancy (NV) centers in diamond. The magnetic resonance signal is detected by probing absorption on the 1042\,nm spin-singlet transition. To improve the absorptive signal the diamond is placed in an optical resonator. The device has a magnetic-field sensitivity of 28 pT/$\sqrt{\rm{Hz}}$, a projected photon shot-noise-limited sensitivity of 22 pT/$\sqrt{\rm{Hz}}$ and an estimated quantum projection-noise-limited sensitivity of 0.43 pT/$\sqrt{\rm{Hz}}$ with the sensing volume of $\sim$ 390 $μ$m $\times$ 4500 $μ$m$^{2}$. The presented miniaturized device is the basis for an endoscopic magnetic field sensor for biomedical applications.
△ Less
Submitted 7 June, 2017;
originally announced June 2017.
-
Level anti-crossing magnetometry with color centers in diamond
Authors:
Huijie Zheng,
Georgios Chatzidrosos,
Arne Wickenbrock,
Lykourgos Bougas,
Reinis Lazda,
Andris Berzins,
Florian Helmuth Gahbauer,
Marcis Auzinsh,
Ruvin Ferber,
Dmitry Budker
Abstract:
Recent developments in magnetic field sensing with negatively charged nitrogen-vacancy centers (NV) in diamond employ magnetic-field (MF) dependent features in the photoluminescence (PL) and eliminate the need for microwaves (MW). Here, we study two approaches towards improving the magnetometric sensitivity using the ground-state level anti-crossing (GSLAC) feature of the NV center at a background…
▽ More
Recent developments in magnetic field sensing with negatively charged nitrogen-vacancy centers (NV) in diamond employ magnetic-field (MF) dependent features in the photoluminescence (PL) and eliminate the need for microwaves (MW). Here, we study two approaches towards improving the magnetometric sensitivity using the ground-state level anti-crossing (GSLAC) feature of the NV center at a background MF of 102.4\,mT. Following the first approach, we investigate the feature parameters for precise alignment in a dilute diamond sample; the second approach extends the sensing protocol into absorption via detection of the GSLAC in the diamond transmission of a 1042\,nm laser beam. This leads to an increase of GSLAC contrast and results in a magnetometer with a sensitivity of 0.45\,nT/$\sqrt{\text{Hz}}$ and a photon shot-noise limited sensitivity of 12.2 pT/$\sqrt{\rm{Hz}}$.
△ Less
Submitted 24 January, 2017;
originally announced January 2017.
-
Solution nuclear magnetic resonance spectroscopy on a nanostructured diamond chip
Authors:
P. Kehayias,
A. Jarmola,
N. Mosavian,
I. Fescenko,
F. M. Benito,
A. Laraoui,
J. Smits,
L. Bougas,
D. Budker,
A. Neumann,
S. R. J. Brueck,
V. M. Acosta
Abstract:
We demonstrate nuclear magnetic resonance (NMR) spectroscopy of picoliter-volume solutions with a nanostructured diamond chip. Using optical interferometric lithography, diamond surfaces were nanostructured with dense, high-aspect-ratio nanogratings, enhancing the surface area by more than a factor of 15 over mm^2 regions of the chip. The nanograting sidewalls were doped with nitrogen-vacancy (NV)…
▽ More
We demonstrate nuclear magnetic resonance (NMR) spectroscopy of picoliter-volume solutions with a nanostructured diamond chip. Using optical interferometric lithography, diamond surfaces were nanostructured with dense, high-aspect-ratio nanogratings, enhancing the surface area by more than a factor of 15 over mm^2 regions of the chip. The nanograting sidewalls were doped with nitrogen-vacancy (NV) centers so that more than 10 million NV centers in a (25 micrometer)^2 laser spot are located close enough to the diamond surface (5 nm) to detect the NMR spectrum of 1 pL of fluid lying within adjacent nanograting grooves. The platform was used to perform 1H and 19F NMR spectroscopy at room temperature in magnetic fields below 50 mT. Using a solution of CsF in glycerol, we demonstrate that 4 +/- 2 x 10^12 19F spins in a 1 pL volume, can be detected with a signal-to-noise ratio of 3 in 1 s integration. This represents nearly two orders of magnitude improvement in concentration sensitivity over previous NV and picoliter NMR studies.
△ Less
Submitted 5 January, 2017;
originally announced January 2017.
-
Optically Detected Magnetic Resonances of Nitrogen-Vacancy Ensembles in 13C Enriched Diamond
Authors:
A. Jarmola,
Z. Bodrog,
P. Kehayias,
M. Markham,
J. Hall,
D. J. Twitchen,
V. M. Acosta,
A. Gali,
D. Budker
Abstract:
We present an experimental and theoretical study of the optically detected magnetic resonance signals for ensembles of negatively charged nitrogen-vacancy (NV) centers in 13C isotopically enriched single-crystal diamond. We observe four broad transition peaks with superimposed sharp features at zero magnetic field and study their dependence on applied magnetic field. A theoretical model that repro…
▽ More
We present an experimental and theoretical study of the optically detected magnetic resonance signals for ensembles of negatively charged nitrogen-vacancy (NV) centers in 13C isotopically enriched single-crystal diamond. We observe four broad transition peaks with superimposed sharp features at zero magnetic field and study their dependence on applied magnetic field. A theoretical model that reproduces all qualitative features of these spectra is developed. Understanding the magnetic-resonance spectra of NV centers in isotopically enriched diamond is important for emerging applications in nuclear magnetic resonance.
△ Less
Submitted 30 August, 2016;
originally announced August 2016.
-
Optical quenching and recovery of photoconductivity in single-crystal diamond
Authors:
Jeson Chen,
Sean Lourette,
Kristine Rezai,
Tobias Hoelzer,
Michael Lake,
Milos Nesladek,
Louis-S. Bouchard,
Philip Hemmer,
Dmitry Budker
Abstract:
We study the photocurrent induced by pulsed-light illumination (pulse duration is several nanoseconds) of single-crystal diamond containing nitrogen impurities. Application of additional continuous-wave light of the same wavelength quenches pulsed photocurrent. Characterization of the optically quenched photocurrent and its recovery is important for the development of diamond based electronics and…
▽ More
We study the photocurrent induced by pulsed-light illumination (pulse duration is several nanoseconds) of single-crystal diamond containing nitrogen impurities. Application of additional continuous-wave light of the same wavelength quenches pulsed photocurrent. Characterization of the optically quenched photocurrent and its recovery is important for the development of diamond based electronics and sensing.
△ Less
Submitted 11 October, 2016; v1 submitted 28 July, 2016;
originally announced July 2016.
-
Microwave-free magnetometry with nitrogen-vacancy centers in diamond
Authors:
Arne Wickenbrock,
Huijie Zheng,
Lykourgos Bougas,
Nathan Leefer,
Samer Afach,
Andrey Jarmola,
Victor M. Acosta,
Dmitry Budker
Abstract:
We use magnetic-field-dependent features in the photoluminescence of negatively charged nitrogen-vacancy centers to measure magnetic fields without the use of microwaves. In particular, we present a magnetometer based on the level anti-crossing in the triplet ground state at 102.4 mT with a demonstrated noise floor of 6 nT/$\sqrt{\text{Hz}}$, limited by the intensity noise of the laser and the per…
▽ More
We use magnetic-field-dependent features in the photoluminescence of negatively charged nitrogen-vacancy centers to measure magnetic fields without the use of microwaves. In particular, we present a magnetometer based on the level anti-crossing in the triplet ground state at 102.4 mT with a demonstrated noise floor of 6 nT/$\sqrt{\text{Hz}}$, limited by the intensity noise of the laser and the performance of the background-field power supply. The technique presented here can be useful in applications where the sensor is placed closed to conductive materials, e.g. magnetic induction tomography or magnetic field mapping, and in remote-sensing applications since principally no electrical access is needed.
△ Less
Submitted 9 June, 2016;
originally announced June 2016.
-
A Precessing Ferromagnetic Needle Magnetometer
Authors:
Derek F. Jackson Kimball,
Alexander O. Sushkov,
Dmitry Budker
Abstract:
A ferromagnetic needle is predicted to precess about the magnetic field axis at a Larmor frequency $Ω$ under conditions where its intrinsic spin dominates over its rotational angular momentum, $N\hbar \gg IΩ$ ($I$ is the moment of inertia of the needle about the precession axis and $N$ is the number of polarized spins in the needle). In this regime the needle behaves as a gyroscope with spin…
▽ More
A ferromagnetic needle is predicted to precess about the magnetic field axis at a Larmor frequency $Ω$ under conditions where its intrinsic spin dominates over its rotational angular momentum, $N\hbar \gg IΩ$ ($I$ is the moment of inertia of the needle about the precession axis and $N$ is the number of polarized spins in the needle). In this regime the needle behaves as a gyroscope with spin $N\hbar$ maintained along the easy axis of the needle by the crystalline and shape anisotropy. A precessing ferromagnetic needle is a correlated system of $N$ spins which can be used to measure magnetic fields for long times. In principle, by taking advantage of rapid averaging of quantum uncertainty, the sensitivity of a precessing needle magnetometer can far surpass that of magnetometers based on spin precession of atoms in the gas phase. Under conditions where noise from coupling to the environment is subdominant, the scaling with measurement time $t$ of the quantum- and detection-limited magnetometric sensitivity is $t^{-3/2}$. The phenomenon of ferromagnetic needle precession may be of particular interest for precision measurements testing fundamental physics.
△ Less
Submitted 20 April, 2016; v1 submitted 8 February, 2016;
originally announced February 2016.
-
Raman and nuclear magnetic resonance investigation of alkali metal vapor interaction with alkene-based anti-relaxation coating
Authors:
O. Yu. Tretiak,
J. W. Blanchard,
D. Budker,
P. K. Olshin,
S. N. Smirnov,
M. V. Balabas
Abstract:
The use of anti-relaxation coatings in alkali vapor cells yields substantial performance improvements by reducing the probability of spin relaxation in wall collisions by several orders of magnitude. Some of the most effective anti-relaxation coating materials are alpha-olefins, which (as in the case of more traditional paraffin coatings) must undergo a curing period after cell manufacturing in or…
▽ More
The use of anti-relaxation coatings in alkali vapor cells yields substantial performance improvements by reducing the probability of spin relaxation in wall collisions by several orders of magnitude. Some of the most effective anti-relaxation coating materials are alpha-olefins, which (as in the case of more traditional paraffin coatings) must undergo a curing period after cell manufacturing in order to achieve the desired behavior. Until now, however, it has been unclear what physicochemical processes occur during cell curing, and how they may affect relevant cell properties. We present the results of nondestructive Raman-spectroscopy and magnetic-resonance investigations of the influence of alkali metal vapor (Cs or K) on an alpha-olefin, 1-nonadecene coating the inner surface of a glass cell. It was found that during the curing process, the alkali metal catalyzes migration of the carbon-carbon double bond, yielding a mixture of cis- and trans-2-nonadecene.
△ Less
Submitted 25 January, 2016;
originally announced January 2016.
-
Longitudinal spin-relaxation in nitrogen-vacancy centers in electron irradiated diamond
Authors:
A. Jarmola,
A. Berzins,
J. Smits,
K. Smits,
J. Prikulis,
F. Gahbauer,
R. Ferber,
D. Erts,
M. Auzinsh,
D. Budker
Abstract:
We present systematic measurements of longitudinal relaxation rates ($1/T_1$) of spin polarization in the ground state of the nitrogen-vacancy (NV$^-$) color center in synthetic diamond as a function of NV$^-$ concentration and magnetic field $B$. NV$^-$ centers were created by irradiating a Type 1b single-crystal diamond along the [100] axis with 200 keV electrons from a transmission electron mic…
▽ More
We present systematic measurements of longitudinal relaxation rates ($1/T_1$) of spin polarization in the ground state of the nitrogen-vacancy (NV$^-$) color center in synthetic diamond as a function of NV$^-$ concentration and magnetic field $B$. NV$^-$ centers were created by irradiating a Type 1b single-crystal diamond along the [100] axis with 200 keV electrons from a transmission electron microscope with varying doses to achieve spots of different NV$^-$ center concentrations. Values of ($1/T_1$) were measured for each spot as a function of $B$.
△ Less
Submitted 19 November, 2015;
originally announced November 2015.
-
Longitudinal spin relaxation in nitrogen-vacancy ensembles in diamond
Authors:
M. Mrozek,
D. Rudnicki,
P. Kehayias,
A. Jarmola,
D. Budker,
W. Gawlik
Abstract:
We present an experimental study of the longitudinal electron-spin relaxation of ensembles of negatively charged nitrogen-vacancy (NV ) centers in diamond. The measurements were performed with samples having different NV- concentrations and at different temperatures and magnetic fields. We found that the relaxation rate T1-1 increases when transition frequencies in NV- centers with different orien…
▽ More
We present an experimental study of the longitudinal electron-spin relaxation of ensembles of negatively charged nitrogen-vacancy (NV ) centers in diamond. The measurements were performed with samples having different NV- concentrations and at different temperatures and magnetic fields. We found that the relaxation rate T1-1 increases when transition frequencies in NV- centers with different orientations become degenerate and interpret this as cross-relaxation caused by dipole-dipole interaction.
△ Less
Submitted 9 May, 2015;
originally announced May 2015.
-
Photoelectrical detection of electron spin resonance of nitrogen-vacancy centres in diamond
Authors:
E. Bourgeois,
A. Jarmola,
M. Gulka,
J. Hruby,
D. Budker,
M. Nesladek
Abstract:
The protocols for the control and readout of Nitrogen Vacancy (NV) centres electron spins in diamond offer an advanced platform for quantum computation, metrology and sensing. These protocols are based on the optical readout of photons emitted from NV centres, which process is limited by the yield of photons collection. Here we report on a novel principle for the detection of NV centres magnetic r…
▽ More
The protocols for the control and readout of Nitrogen Vacancy (NV) centres electron spins in diamond offer an advanced platform for quantum computation, metrology and sensing. These protocols are based on the optical readout of photons emitted from NV centres, which process is limited by the yield of photons collection. Here we report on a novel principle for the detection of NV centres magnetic resonance in diamond by directly monitoring spin-preserving electron transitions through measurement of NV centre related photocurrent. The demonstrated direct detection technique offers a sensitive way for the readout of diamond NV sensors and diamond quantum devices on diamond chips. The Photocurrent Detection of Magnetic Resonance (PDMR) scheme is based on the detection of charge carriers promoted to the conduction band of diamond by the two-photon ionization of NV- centres. Optical detection of magnetic resonance (ODMR) and PDMR are compared, by performing both measurements simultaneously. The minima detected in the measured photocurrent at resonant microwave frequencies are attributed to the spin-dependent occupation probability of the NV- ground state, originating from spin-selective non-radiative transitions.
△ Less
Submitted 26 February, 2015;
originally announced February 2015.
-
Microwave saturation spectroscopy of nitrogen-vacancy ensembles in diamond
Authors:
P. Kehayias,
M. Mrózek,
V. M. Acosta,
A. Jarmola,
D. S. Rudnicki,
R. Folman,
W. Gawlik,
D. Budker
Abstract:
Negatively-charged nitrogen-vacancy (NV$^-$) centers in diamond have generated much recent interest for their use in sensing. The sensitivity improves when the NV ground-state microwave transitions are narrow, but these transitions suffer from inhomogeneous broadening, especially in high-density NV ensembles. To better understand and remove the sources of broadening, we demonstrate room-temperatur…
▽ More
Negatively-charged nitrogen-vacancy (NV$^-$) centers in diamond have generated much recent interest for their use in sensing. The sensitivity improves when the NV ground-state microwave transitions are narrow, but these transitions suffer from inhomogeneous broadening, especially in high-density NV ensembles. To better understand and remove the sources of broadening, we demonstrate room-temperature spectral "hole burning" of the NV ground-state transitions. We find that hole burning removes the broadening caused by magnetic fields from $^{13}$C nuclei and demonstrate that it can be used for magnetic-field-insensitive thermometry.
△ Less
Submitted 9 March, 2014;
originally announced March 2014.
-
The temperature shifts of the resonances of the NV- center in diamond
Authors:
Marcus W. Doherty,
Victor M. Acosta,
Andrey Jarmola,
Michael S. J. Barson,
Neil B. Manson,
Dmitry Budker,
Lloyd C. L. Hollenberg
Abstract:
Significant attention has been recently focused on the realization of high precision nano-thermometry using the spin-resonance temperature shift of the negatively charged nitrogen-vacancy (NV-) center in diamond. However, the precise physical origins of the temperature shift is yet to be understood. Here, the shifts of the center's optical and spin resonances are observed and a model is developed…
▽ More
Significant attention has been recently focused on the realization of high precision nano-thermometry using the spin-resonance temperature shift of the negatively charged nitrogen-vacancy (NV-) center in diamond. However, the precise physical origins of the temperature shift is yet to be understood. Here, the shifts of the center's optical and spin resonances are observed and a model is developed that identifies the origin of each shift to be a combination of thermal expansion and electron-phonon interactions. Our results provide new insight into the center's vibronic properties and reveal implications for NV- thermometry.
△ Less
Submitted 27 October, 2013;
originally announced October 2013.
-
Long-lived heteronuclear spin-singlet states
Authors:
Meike Emondts,
Micah. P. Ledbetter,
Szymon Pustelny,
Thomas Theis,
Brian Patton,
John W. Blanchard,
Mark C. Butler,
Dmitry Budker,
Alexander Pines
Abstract:
We report observation of long-lived spin-singlet states in a 13C-1H spin pair at zero magnetic field. In 13C-labeled formic acid, we observe spin-singlet lifetimes as long as 37 seconds, about a factor of three longer than the T1 lifetime of dipole polarization in the triplet state. We also observe that the lifetime of the singlet-triplet coherence, T2, is longer than T1. Moreover, we demonstrate…
▽ More
We report observation of long-lived spin-singlet states in a 13C-1H spin pair at zero magnetic field. In 13C-labeled formic acid, we observe spin-singlet lifetimes as long as 37 seconds, about a factor of three longer than the T1 lifetime of dipole polarization in the triplet state. We also observe that the lifetime of the singlet-triplet coherence, T2, is longer than T1. Moreover, we demonstrate that this singlet states formed by spins of a heteronucleus and a 1H nucleus, can exhibit longer lifetimes than the respective triplet states in systems consisting of more than two nuclear spins. Although long-lived homonuclear spin-singlet states have been extensively studied, this is the first experimental observation of analogous spin-singlets consisting of a heteronucleus and a proton.
△ Less
Submitted 4 October, 2013;
originally announced October 2013.
-
Diamond Magnetometry of Superconducting Thin Films
Authors:
A. Waxman,
H. Schlussel,
D. Groswasser,
V. M. Acosta,
L. -S. Bouchard,
D. Budker,
R. Folman
Abstract:
In recent years diamond magnetometers based on the nitrogen-vacancy (NV) center have been of considerable interest for magnetometry applications at the nanoscale. An interesting application which is well suited for NV centers is the study of nanoscale magnetic phenomena in superconducting materials. We employ the magnetic sensitivity of NV centers in diamond to interrogate the magnetic properties…
▽ More
In recent years diamond magnetometers based on the nitrogen-vacancy (NV) center have been of considerable interest for magnetometry applications at the nanoscale. An interesting application which is well suited for NV centers is the study of nanoscale magnetic phenomena in superconducting materials. We employ the magnetic sensitivity of NV centers in diamond to interrogate the magnetic properties of a thin-layer yttrium barium copper oxide (YBCO) superconductor. Using fluorescence-microscopy methods and samples integrated with an NV sensor on a microchip, we measure the temperature of phase transition in the layer to be 70.0(2) K, and the penetration field of vortices to be 46(4) G. We observe the pinning of the vortices in the layer at 65 K, and estimate their density after cooling the sample in a ~ 10 G field to be 0.45(1) μm^{-2}. These measurements are done with a 10 nm thick NV layer, so that high spatial resolution may be enabled in the future. Based on these results, we anticipate that this magnetometer could be useful for imaging the structure and dynamics of vortices. As an outlook, we present a fabrication method for a superconductor chip designed for this purpose.
△ Less
Submitted 5 February, 2014; v1 submitted 12 August, 2013;
originally announced August 2013.
-
Cosmic Axion Spin Precession Experiment (CASPEr)
Authors:
Dmitry Budker,
Peter W. Graham,
Micah Ledbetter,
Surjeet Rajendran,
Alex Sushkov
Abstract:
We propose an experiment to search for QCD axion and axion-like-particle (ALP) dark matter. Nuclei that are interacting with the background axion dark matter acquire time-varying CP-odd nuclear moments such as an electric dipole moment. In analogy with nuclear magnetic resonance, these moments cause precession of nuclear spins in a material sample in the presence of an electric field. Precision ma…
▽ More
We propose an experiment to search for QCD axion and axion-like-particle (ALP) dark matter. Nuclei that are interacting with the background axion dark matter acquire time-varying CP-odd nuclear moments such as an electric dipole moment. In analogy with nuclear magnetic resonance, these moments cause precession of nuclear spins in a material sample in the presence of an electric field. Precision magnetometry can be used to search for such precession. An initial phase of this experiment could cover many orders of magnitude in ALP parameter space beyond the current astrophysical and laboratory limits. And with established techniques, the proposed experimental scheme has sensitivity to QCD axion masses m_a < 10^-9 eV, corresponding to theoretically well-motivated axion decay constants f_a > 10^16 GeV. With further improvements, this experiment could ultimately cover the entire range of masses m_a < 10^-6 eV, complementary to cavity searches.
△ Less
Submitted 29 May, 2014; v1 submitted 25 June, 2013;
originally announced June 2013.
-
Electromagnetically-induced transparency in a diamond spin ensemble enables all-optical electromagnetic field sensing
Authors:
Victor M. Acosta,
Kasper Jensen,
Charles Santori,
Dmitry Budker,
Rymond G. Beausoleil
Abstract:
We use electromagnetically-induced transparency (EIT) to probe the narrow electron-spin resonance of nitrogen-vacancy centers in diamond. Working with a multi-pass diamond chip at temperatures 6-30 K, the zero-phonon absorption line (637 nm) exhibits an optical depth of 6 and inhomogenous linewidth of ~30 GHz full-width-at-half-maximum (FWHM). Simultaneous optical excitation at two frequencies sep…
▽ More
We use electromagnetically-induced transparency (EIT) to probe the narrow electron-spin resonance of nitrogen-vacancy centers in diamond. Working with a multi-pass diamond chip at temperatures 6-30 K, the zero-phonon absorption line (637 nm) exhibits an optical depth of 6 and inhomogenous linewidth of ~30 GHz full-width-at-half-maximum (FWHM). Simultaneous optical excitation at two frequencies separated by the ground-state zero-field splitting (2.88 GHz), reveals EIT resonances with a contrast exceeding 6% and FWHM down to 0.4 MHz. The resonances provide an all-optical probe of external electric and magnetic fields with a projected photon-shot-noise-limited sensitivity of 0.2 V/cm/sqrt(Hz) and 0.1 nT/sqrt(Hz), respectively. Operation of a prototype diamond-EIT magnetometer measures a noise floor of less than 1 nT/sqrt(Hz) for frequencies above 10 Hz and Allan deviation of 1.3 +/- 1.1 nT for 100 s intervals. The results demonstrate the potential of diamond-EIT devices for applications ranging from quantum-optical memory to few-photon nonlinear optics, precision measurement, and tests of fundamental physics.
△ Less
Submitted 24 May, 2013; v1 submitted 27 March, 2013;
originally announced March 2013.
-
The Infrared Absorption Band and Vibronic Structure of the Nitrogen-Vacancy Center in Diamond
Authors:
P. Kehayias,
M. W. Doherty,
D. English,
R. Fischer,
A. Jarmola,
K. Jensen,
N. Leefer,
P. Hemmer,
N. B. Manson,
D. Budker
Abstract:
Negatively-charged nitrogen-vacancy (NV$^-$) color centers in diamond have generated much interest for use in quantum technology. Despite the progress made in developing their applications, many questions about the basic properties of NV$^-$ centers remain unresolved. Understanding these properties can validate theoretical models of NV$^-$, improve their use in applications, and support their deve…
▽ More
Negatively-charged nitrogen-vacancy (NV$^-$) color centers in diamond have generated much interest for use in quantum technology. Despite the progress made in developing their applications, many questions about the basic properties of NV$^-$ centers remain unresolved. Understanding these properties can validate theoretical models of NV$^-$, improve their use in applications, and support their development into competitive quantum devices. In particular, knowledge of the phonon modes of the $^1A_1$ electronic state is key for understanding the optical pumping process. Using pump-probe spectroscopy, we measured the phonon sideband of the ${^1}E\rightarrow{^1}A_1$ electronic transition in the NV$^-$ center. From this we calculated the ${^1}E\rightarrow{^1}A_1$ one-phonon absorption spectrum and found it to differ from that of the ${^3}E\rightarrow{^3}A_2$ transition, a result which is not anticipated by previous group-theoretical models of the NV$^-$ electronic states. We identified a high-energy 169 meV localized phonon mode of the $^1A_1$ level.
△ Less
Submitted 2 October, 2013; v1 submitted 25 January, 2013;
originally announced January 2013.
-
Solid-state electronic spin coherence time approaching one second
Authors:
Nir Bar-Gill,
Linh M. Pham,
Andrejs Jarmola,
Dmitry Budker,
Ronald L. Walsworth
Abstract:
Solid-state electronic spin systems such as nitrogen-vacancy (NV) color centers in diamond are promising for applications of quantum information, sensing, and metrology. However, a key challenge for such solid-state systems is to realize a spin coherence time that is much longer than the time for quantum spin manipulation protocols. Here we demonstrate an improvement of more than two orders of mag…
▽ More
Solid-state electronic spin systems such as nitrogen-vacancy (NV) color centers in diamond are promising for applications of quantum information, sensing, and metrology. However, a key challenge for such solid-state systems is to realize a spin coherence time that is much longer than the time for quantum spin manipulation protocols. Here we demonstrate an improvement of more than two orders of magnitude in the spin coherence time ($T_2$) of NV centers compared to previous measurements: $T_2 \approx 0.5$ s at 77 K, which enables $\sim 10^7$ coherent NV spin manipulations before decoherence. We employed dynamical decoupling pulse sequences to suppress NV spin decoherence due to magnetic noise, and found that $T_2$ is limited to approximately half of the longitudinal spin relaxation time ($T_1$) over a wide range of temperatures, which we attribute to phonon-induced decoherence. Our results apply to ensembles of NV spins and do not depend on the optimal choice of a specific NV, which could advance quantum sensing, enable squeezing and many-body entanglement in solid-state spin ensembles, and open a path to simulating a wide range of driven, interaction-dominated quantum many-body Hamiltonians.
△ Less
Submitted 6 December, 2012; v1 submitted 29 November, 2012;
originally announced November 2012.
-
Vibrational and electronic ultrafast relaxation of the nitrogen-vacancy centers in diamond
Authors:
V. M. Huxter,
T. A. A. Oliver,
D. Budker,
G. R. Fleming
Abstract:
Two dimensional electronic spectroscopy and transient grating measurements were performed, for the first time, on nitrogen-vacancy centers in diamond. These measurements reveal energy transfer and vibrational pathways with consequences for spin coherence.
Two dimensional electronic spectroscopy and transient grating measurements were performed, for the first time, on nitrogen-vacancy centers in diamond. These measurements reveal energy transfer and vibrational pathways with consequences for spin coherence.
△ Less
Submitted 17 July, 2012;
originally announced July 2012.