-
Flux Trapping Characterization for Superconducting Electronics Using a Cryogenic Widefield NV-Diamond Microscope
Authors:
Rohan T. Kapur,
Pauli Kehayias,
Sergey K. Tolpygo,
Adam A. Libson,
George Haldeman,
Collin N. Muniz,
Alex Wynn,
Nathaniel J. O'Connor,
Neel A. Parmar,
Ryan Johnson,
Andrew C. Maccabe,
John Cummings,
Justin L. Mallek,
Danielle A. Braje,
Jennifer M. Schloss
Abstract:
Magnetic flux trapping is a significant hurdle limiting reliability and scalability of superconducting electronics, yet tools for imaging flux vortices remain slow or insensitive. We present a cryogenic widefield NV-diamond magnetic microscope capable of rapid, micron-scale imaging of flux trapping in superconducting devices. Using this technique, we measure vortex expulsion fields in Nb thin film…
▽ More
Magnetic flux trapping is a significant hurdle limiting reliability and scalability of superconducting electronics, yet tools for imaging flux vortices remain slow or insensitive. We present a cryogenic widefield NV-diamond magnetic microscope capable of rapid, micron-scale imaging of flux trapping in superconducting devices. Using this technique, we measure vortex expulsion fields in Nb thin films and patterned strips, revealing a crossover in expulsion behavior between $10$ and $20~μ$m strip widths. The observed scaling agrees with theoretical models and suggests the influence of film defects on vortex expulsion dynamics. This instrument enables high-throughput magnetic characterization of superconducting materials and circuits, providing new insight for flux mitigation strategies in scalable superconducting electronics.
△ Less
Submitted 2 June, 2025;
originally announced June 2025.
-
Ferrimagnetic Oscillator Magnetometer
Authors:
John F. Barry,
Reed A. Irion,
Matthew H. Steinecker,
Daniel K. Freeman,
Jessica J. Kedziora,
Reginald G. Wilcox,
Danielle A. Braje
Abstract:
Quantum sensors offer unparalleled precision, accuracy, and sensitivity for a variety of measurement applications. We report a compact magnetometer based on a ferrimagnetic sensing element in an oscillator architecture that circumvents challenges common to other quantum sensing approaches such as limited dynamic range, limited bandwidth, and dependence on vacuum, cryogenic, or laser components. Th…
▽ More
Quantum sensors offer unparalleled precision, accuracy, and sensitivity for a variety of measurement applications. We report a compact magnetometer based on a ferrimagnetic sensing element in an oscillator architecture that circumvents challenges common to other quantum sensing approaches such as limited dynamic range, limited bandwidth, and dependence on vacuum, cryogenic, or laser components. The device exhibits a fixed, calibration-free response governed by the electron gyromagnetic ratio. Exchange narrowing in the ferrimagnetic material produces sub-MHz transition linewidths despite the high unpaired spin density ($\sim 10^{22}$ cm$^{-3}$). The magnetometer achieves a minimum sensitivity of 100 fT/$\sqrt{\text{Hz}}$ to AC magnetic fields of unknown phase and a sensitivity below 200 fT/$\sqrt{\text{Hz}}$ over a bandwidth $\gtrsim \! 1$ MHz. By encoding magnetic field in frequency rather than amplitude, the device provides a dynamic range in excess of 1 mT. The passive, thermal initialization of the sensor's quantum state requires only a magnetic bias field, greatly reducing power requirements compared to laser-initialized quantum sensors. With additional development, this device promises to be a leading candidate for high-performance magnetometry outside the laboratory, and the oscillator architecture is expected to provide advantages across a wide range of sensing platforms.
△ Less
Submitted 31 May, 2023;
originally announced May 2023.
-
Sensitive AC and DC Magnetometry with Nitrogen-Vacancy Center Ensembles in Diamond
Authors:
John F. Barry,
Matthew H. Steinecker,
Scott T. Alsid,
Jonah Majumder,
Linh M. Pham,
Michael F. O'Keefe,
Danielle A. Braje
Abstract:
Quantum sensing with solid-state spins offers the promise of high spatial resolution, bandwidth, and dynamic range at sensitivities comparable to more mature quantum sensing technologies, such as atomic vapor cells and superconducting devices. However, despite comparable theoretical sensitivity limits, the performance of bulk solid-state quantum sensors has so far lagged behind these more mature a…
▽ More
Quantum sensing with solid-state spins offers the promise of high spatial resolution, bandwidth, and dynamic range at sensitivities comparable to more mature quantum sensing technologies, such as atomic vapor cells and superconducting devices. However, despite comparable theoretical sensitivity limits, the performance of bulk solid-state quantum sensors has so far lagged behind these more mature alternatives. A recent review~\cite{barry2020sensitivity} suggests several paths to improve performance of magnetometers employing nitrogen-vacancy defects in diamond, the most-studied solid-state quantum sensing platform. Implementing several suggested techniques, we demonstrate the most sensitive nitrogen-vacancy-based bulk magnetometer reported to date. Our approach combines tailored diamond growth to achieve low strain and long intrinsic dephasing times, the use of double-quantum Ramsey and Hahn echo magnetometry sequences for broadband and narrowband magnetometry respectively, and P1 driving to further extend dephasing time. Notably, the device does not include a flux concentrator, preserving the fixed response of the NVs to magnetic field. The magnetometer realizes a broadband \textcolor{mhsnew}{near-}DC sensitivity $\sim 460$~fT$\cdot$s$^{1/2}$ and a narrowband AC sensitivity $\sim 210$~fT$\cdot$s$^{1/2}$. We describe the experimental setup in detail and highlight potential paths for future improvement.
△ Less
Submitted 10 May, 2023;
originally announced May 2023.
-
Large-scale optical characterization of solid-state quantum emitters
Authors:
Madison Sutula,
Ian Christen,
Eric Bersin,
Michael P. Walsh,
Kevin C. Chen,
Justin Mallek,
Alexander Melville,
Michael Titze,
Edward S. Bielejec,
Scott Hamilton,
Danielle Braje,
P. Benjamin Dixon,
Dirk R. Englund
Abstract:
Solid-state quantum emitters have emerged as a leading quantum memory for quantum networking applications. However, standard optical characterization techniques are neither efficient nor repeatable at scale. In this work, we introduce and demonstrate spectroscopic techniques that enable large-scale, automated characterization of color centers. We first demonstrate the ability to track color center…
▽ More
Solid-state quantum emitters have emerged as a leading quantum memory for quantum networking applications. However, standard optical characterization techniques are neither efficient nor repeatable at scale. In this work, we introduce and demonstrate spectroscopic techniques that enable large-scale, automated characterization of color centers. We first demonstrate the ability to track color centers by registering them to a fabricated machine-readable global coordinate system, enabling systematic comparison of the same color center sites over many experiments. We then implement resonant photoluminescence excitation in a widefield cryogenic microscope to parallelize resonant spectroscopy, achieving two orders of magnitude speed-up over confocal microscopy. Finally, we demonstrate automated chip-scale characterization of color centers and devices at room temperature, imaging thousands of microscope fields of view. These tools will enable accelerated identification of useful quantum emitters at chip-scale, enabling advances in scaling up color center platforms for quantum information applications, materials science, and device design and characterization.
△ Less
Submitted 24 October, 2022;
originally announced October 2022.
-
A Solid-State Microwave Magnetometer with Picotesla-Level Sensitivity
Authors:
Scott T. Alsid,
Jennifer M. Schloss,
Matthew H. Steinecker,
John F. Barry,
Andrew C. Maccabe,
Guoqing Wang,
Paola Cappellaro,
Danielle A. Braje
Abstract:
Quantum sensing of low-frequency magnetic fields using nitrogen-vacancy (NV) center ensembles has been demonstrated in multiple experiments with sensitivities as low as $\sim$1 pT/$\sqrt{\text{Hz}}$. To date, however, demonstrations of high-frequency magnetometry in the GHz regime with NV diamond are orders of magnitude less sensitive, above the nT/$\sqrt{\text{Hz}}$ level. Here we adapt for micro…
▽ More
Quantum sensing of low-frequency magnetic fields using nitrogen-vacancy (NV) center ensembles has been demonstrated in multiple experiments with sensitivities as low as $\sim$1 pT/$\sqrt{\text{Hz}}$. To date, however, demonstrations of high-frequency magnetometry in the GHz regime with NV diamond are orders of magnitude less sensitive, above the nT/$\sqrt{\text{Hz}}$ level. Here we adapt for microwave frequencies techniques that have enabled high-performance, low-frequency quantum sensors. Using a custom-grown NV-enriched diamond combined with a noise cancellation scheme designed for high-frequency sensing, we demonstrate a Rabi-sequence-based magnetometer able to detect microwave fields near 2.87 GHz with a record sensitivity of 3.4 pT/$\sqrt{\textrm{Hz}}$. We demonstrate both amplitude and phase sensing and project tunability over a 300 MHz frequency range. This result increases the viability of NV ensembles to serve as microwave circuitry imagers and near-field probes of antennas.
△ Less
Submitted 30 June, 2022;
originally announced June 2022.
-
Thermally-Polarized Solid-State Spin Sensor
Authors:
Reginald Wilcox,
Erik Eisenach,
John Barry,
Matthew Steinecker,
Michael O'Keeffe,
Dirk Englund,
Danielle Braje
Abstract:
Quantum sensors based on spin defect ensembles have seen rapid development in recent years, with a wide array of target applications. Historically, these sensors have used optical methods to prepare or read out quantum states. However, these methods are limited to optically-polarizable spin defects, and the spin ensemble size is typically limited by the available optical power or acceptable optica…
▽ More
Quantum sensors based on spin defect ensembles have seen rapid development in recent years, with a wide array of target applications. Historically, these sensors have used optical methods to prepare or read out quantum states. However, these methods are limited to optically-polarizable spin defects, and the spin ensemble size is typically limited by the available optical power or acceptable optical heat load. We demonstrate a solid-state sensor employing a non-optical state preparation technique, which harnesses thermal population imbalances induced by the defect's zero-field splitting. Readout is performed using the recently-demonstrated microwave cavity readout technique, resulting in a sensor architecture that is entirely non-optical and broadly applicable to all solid-state paramagnetic defects with a zero-field splitting. The implementation in this work uses Cr$^{3+}$ defects in a sapphire (Al$_2$O$_3$) crystal and a simple microwave architecture where the host crystal also serves as the high quality-factor resonator. This approach yields a near-unity filling factor and high single-spin-photon coupling, producing a magnetometer with a broadband sensitivity of 9.7 pT/$\sqrt{\text{Hz}}$.
△ Less
Submitted 3 September, 2021;
originally announced September 2021.
-
Cavity quantum electrodynamic readout of a solid-state spin sensor
Authors:
Erik R. Eisenach,
John F. Barry,
Michael F. O'Keeffe,
Jennifer M. Schloss,
Matthew H. Steinecker,
Dirk R. Englund,
Danielle A. Braje
Abstract:
Robust, high-fidelity readout is central to quantum device performance. Overcoming poor readout is an increasingly urgent challenge for devices based on solid-state spin defects, particularly given their rapid adoption in quantum sensing, quantum information, and tests of fundamental physics. Spin defects in solids combine the repeatability and precision available to atomic and cryogenic systems w…
▽ More
Robust, high-fidelity readout is central to quantum device performance. Overcoming poor readout is an increasingly urgent challenge for devices based on solid-state spin defects, particularly given their rapid adoption in quantum sensing, quantum information, and tests of fundamental physics. Spin defects in solids combine the repeatability and precision available to atomic and cryogenic systems with substantial advantages in compactness and range of operating conditions. However, in spite of experimental progress in specific systems, solid-state spin sensors still lack a universal, high-fidelity readout technique. Here we demonstrate high-fidelity, room-temperature readout of an ensemble of nitrogen-vacancy (NV) centers via strong coupling to a dielectric microwave cavity, building on similar techniques commonly applied in cryogenic circuit cavity quantum electrodynamics. This strong collective interaction allows the spin ensemble's microwave transition to be probed directly, thereby overcoming the optical photon shot noise limitations of conventional fluorescence readout. Applying this technique to magnetometry, we show magnetic sensitivity approaching the Johnson-Nyquist noise limit of the system. This readout technique is viable for the many paramagnetic spin systems that exhibit resonances in the microwave domain. Our results pave a clear path to achieve unity readout fidelity of solid-state spin sensors through increased ensemble size, reduced spin-resonance linewidth, or improved cavity quality factor.
△ Less
Submitted 2 March, 2020;
originally announced March 2020.
-
Photoluminescence decomposition analysis: a technique to characterize NV creation in diamond
Authors:
Scott Alsid,
John Barry,
Linh Pham,
Jennifer Schloss,
Michael O'Keefe,
Paola Cappellaro,
Danielle Braje
Abstract:
Treatment of lab-grown diamond by electron irradiation and annealing has enabled quantum sensors based on negatively-charged nitrogen-vacancy (NV$^\text{-}$) centers to demonstrate record sensitivities. \cite{Clevenson2015,Wolf2015,Barry2016,Chatzidrosos2017}. Here we investigate the irradiation and annealing process applied to 28 diamond samples using a new ambient-temperature, all-optical approa…
▽ More
Treatment of lab-grown diamond by electron irradiation and annealing has enabled quantum sensors based on negatively-charged nitrogen-vacancy (NV$^\text{-}$) centers to demonstrate record sensitivities. \cite{Clevenson2015,Wolf2015,Barry2016,Chatzidrosos2017}. Here we investigate the irradiation and annealing process applied to 28 diamond samples using a new ambient-temperature, all-optical approach. As the presence of the neutrally-charged nitrogen-vacancy (NV$^\text{0}$) center is deleterious to sensor performance, this photoluminescence decomposition analysis (PDA) is first employed to determine the concentration ratio of NV$^\text{-}$ to NV$^0$ in diamond samples from the measured photoluminescence spectrum. The analysis hinges on (i) isolating each NV charge state's emission spectrum and (ii) measuring the NV$^\text{-}$ to NV$^0$ emission ratio, which is found to be 2.5$\pm$0.5 under low-intensity 532 nm illumination. Using the PDA method, we measure the effects of irradiation and annealing on conversion of substitutional nitrogen to NV centers. Combining these measurements with a phenomenological model for diamond irradiation and annealing, we extract an estimated monovacancy creation rate of $0.52\pm 0.26$ cm$^{\text{-1}}$ for 1 MeV electron irradiation and an estimated monovacancy diffusion coefficient of 1.8 nm$^2$/s at 850~$^\circ$C. Finally we find that irradiation doses $\gtrsim 10^{18}$ e$^\text{-}$/cm$^2$ deteriorate the NV$^\text{-}$ decoherence time $T_2$ whereas $T_1$ is unaffected up to the the maximum investigated dose of $5\times 10^{18}$ e$^\text{-}$/cm$^2$.
△ Less
Submitted 26 June, 2019;
originally announced June 2019.
-
Robust High-Dynamic-Range Vector Magnetometry via Nitrogen-Vacancy Centers in Diamond
Authors:
Hannah Clevenson,
Linh M. Pham,
Carson Teale,
Kerry Johnson,
Dirk Englund,
Danielle Braje
Abstract:
We demonstrate a robust, scale-factor-free vector magnetometer, which uses a closed-loop frequency-locking scheme to simultaneously track Zeeman-split resonance pairs of nitrogen-vacancy (NV) centers in diamond. Compared with open-loop methodologies, this technique is robust against fluctuations in temperature, resonance linewidth, and contrast; offers a three-order-of-magnitude increase in dynami…
▽ More
We demonstrate a robust, scale-factor-free vector magnetometer, which uses a closed-loop frequency-locking scheme to simultaneously track Zeeman-split resonance pairs of nitrogen-vacancy (NV) centers in diamond. Compared with open-loop methodologies, this technique is robust against fluctuations in temperature, resonance linewidth, and contrast; offers a three-order-of-magnitude increase in dynamic range; and allows for simultaneous interrogation of multiple transition frequencies. By directly detecting the resonance frequencies of NV centers aligned along each of the diamond's four tetrahedral crystallographic axes, we perform full vector reconstruction of an applied magnetic field.
△ Less
Submitted 26 February, 2018;
originally announced February 2018.
-
High-sensitivity, spin-based electrometry with an ensemble of nitrogen-vacancy centers in diamond
Authors:
Edward H. Chen,
Hannah A. Clevenson,
Kerry A. Johnson,
Linh M. Pham,
Dirk R. Englund,
Philip R. Hemmer,
Danielle A. Braje
Abstract:
We demonstrate a spin-based, all-dielectric electrometer based on an ensemble of nitrogen-vacancy (NV$^-$) defects in diamond. An applied electric field causes energy level shifts symmetrically away from the NV$^-$'s degenerate triplet states via the Stark effect; this symmetry provides immunity to temperature fluctuations allowing for shot-noise-limited detection. Using an ensemble of NV$^-$s, we…
▽ More
We demonstrate a spin-based, all-dielectric electrometer based on an ensemble of nitrogen-vacancy (NV$^-$) defects in diamond. An applied electric field causes energy level shifts symmetrically away from the NV$^-$'s degenerate triplet states via the Stark effect; this symmetry provides immunity to temperature fluctuations allowing for shot-noise-limited detection. Using an ensemble of NV$^-$s, we demonstrate shot-noise limited sensitivities approaching 1 V/cm/$\sqrt{\text{Hz}}$ under ambient conditions, at low frequencies ($<$10 Hz), and over a large dynamic range (20 dB). A theoretical model for the ensemble of NV$^-$s fits well with measurements of the ground-state electric susceptibility parameter, $\langle k_\perp\rangle$. Implications of spin-based, dielectric sensors for micron-scale electric-field sensing are discussed.
△ Less
Submitted 22 March, 2017;
originally announced March 2017.
-
Broadband Magnetometry and Temperature Sensing with a Light Trapping Diamond Waveguide
Authors:
Hannah Clevenson,
Matthew E. Trusheim,
Tim Schroder,
Carson Teale,
Danielle Braje,
Dirk Englund
Abstract:
Solid-state quantum sensors are attracting wide interest because of their exceptional sensitivity at room temperature. In particular, the spin properties of individual nitrogen vacancy (NV) color centers in diamond make it an outstanding nanoscale sensor of magnetic fields, electric fields, and temperature, under ambient conditions. Recent work on ensemble NV-based magnetometers, inertial sensors,…
▽ More
Solid-state quantum sensors are attracting wide interest because of their exceptional sensitivity at room temperature. In particular, the spin properties of individual nitrogen vacancy (NV) color centers in diamond make it an outstanding nanoscale sensor of magnetic fields, electric fields, and temperature, under ambient conditions. Recent work on ensemble NV-based magnetometers, inertial sensors, and clocks have employed $N$ unentangled color centers to realize a factor of up to $\sqrt{N}$ improvement in sensitivity. However, to realize fully this signal enhancement, new techniques are required to excite efficiently and to collect fluorescence from large NV ensembles. Here, we introduce a light-trapping diamond waveguide (LTDW) geometry that enables both high fluorescence collection ($\sim20\%$) and efficient pump absorption achieving an effective path length exceeding $1$ meter in a millimeter-sized device. The LTDW enables in excess of $2\%$ conversion efficiency of pump photons into optically detected magnetic resonance (ODMR) fluorescence, a \textit{three orders of magnitude} improvement over previous single-pass geometries. This dramatic enhancement of ODMR signal enables broadband measurements of magnetic field and temperature at less than $1$ Hz, a frequency range inaccessible by dynamical decoupling techniques. We demonstrate $\sim 1~\mbox{nT}/\sqrt{\mbox{Hz}}$ magnetic field sensitivity for $0.1$ Hz to $10$ Hz and a thermal sensitivity of $\sim 400 ~μ\mbox{K}/\sqrt{\mbox{Hz}}$ and estimate a spin projection limit at $\sim 0.36$ fT/$\sqrt{\mbox{Hz}}$ and $\sim 139~\mbox{pK}/\sqrt{\mbox{Hz}}$, respectively.
△ Less
Submitted 19 June, 2014;
originally announced June 2014.
-
Driven dynamics and rotary echo of a qubit tunably coupled to a harmonic oscillator
Authors:
Simon Gustavsson,
Jonas Bylander,
Fei Yan,
Pol Forn-Díaz,
Vlad Bolkhovsky,
Danielle Braje,
George Fitch,
Khalil Harrabi,
Donna Lennon,
Jovi Miloshi,
Peter Murphy,
Rick Slattery,
Steven Spector,
Ben Turek,
Terry Weir,
Paul B. Welander,
Fumiki Yoshihara,
David G. Cory,
Yasunobu Nakamura,
Terry P. Orlando,
William D. Oliver
Abstract:
We have investigated the driven dynamics of a superconducting flux qubit that is tunably coupled to a microwave resonator. We find that the qubit experiences an oscillating field mediated by off-resonant driving of the resonator, leading to strong modifications of the qubit Rabi frequency. This opens an additional noise channel, and we find that low-frequency noise in the coupling parameter causes…
▽ More
We have investigated the driven dynamics of a superconducting flux qubit that is tunably coupled to a microwave resonator. We find that the qubit experiences an oscillating field mediated by off-resonant driving of the resonator, leading to strong modifications of the qubit Rabi frequency. This opens an additional noise channel, and we find that low-frequency noise in the coupling parameter causes a reduction of the coherence time during driven evolution. The noise can be mitigated with the rotary-echo pulse sequence, which, for driven systems, is analogous to the Hahn-echo sequence.
△ Less
Submitted 30 January, 2012;
originally announced January 2012.
-
Sub-micrometer epitaxial Josephson junctions for quantum circuits
Authors:
Jeffrey S. Kline,
Michael R. Vissers,
Fabio C. S. da Silva,
David S. Wisbey,
Martin Weides,
Terence J. Weir,
Benjamin Turek,
Danielle A. Braje,
William D. Oliver,
Yoni Shalibo,
Nadav Katz,
Blake R. Johnson,
Thomas A. Ohki,
David P. Pappas
Abstract:
We present a fabrication scheme and testing results for epitaxial sub-micrometer Josephson junctions. The junctions are made using a high-temperature (1170 K) "via process" yielding junctions as small as 0.8 mu m in diameter by use of optical lithography. Sapphire (Al2O3) tunnel-barriers are grown on an epitaxial Re/Ti multilayer base-electrode. We have fabricated devices with both Re and Al top e…
▽ More
We present a fabrication scheme and testing results for epitaxial sub-micrometer Josephson junctions. The junctions are made using a high-temperature (1170 K) "via process" yielding junctions as small as 0.8 mu m in diameter by use of optical lithography. Sapphire (Al2O3) tunnel-barriers are grown on an epitaxial Re/Ti multilayer base-electrode. We have fabricated devices with both Re and Al top electrodes. While room-temperature (295 K) resistance versus area data are favorable for both types of top electrodes, the low-temperature (50 mK) data show that junctions with the Al top electrode have a much higher subgap resistance. The microwave loss properties of the junctions have been measured by use of superconducting Josephson junction qubits. The results show that high subgap resistance correlates to improved qubit performance.
△ Less
Submitted 22 November, 2011; v1 submitted 8 August, 2011;
originally announced August 2011.
-
Remote Sensing and Control of Phase Qubits
Authors:
Dale Li,
Fabio C. S. da Silva,
Danielle A. Braje,
Raymond W. Simmonds,
David P. Pappas
Abstract:
We demonstrate a remote sensing design of phase qubits by separating the control and readout circuits from the qubit loop. This design improves measurement reliability because the control readout chip can be fabricated using more robust materials and can be reused to test different qubit chips. Typical qubit measurements such as Rabi oscillations, spectroscopy, and excited-state energy relaxation…
▽ More
We demonstrate a remote sensing design of phase qubits by separating the control and readout circuits from the qubit loop. This design improves measurement reliability because the control readout chip can be fabricated using more robust materials and can be reused to test different qubit chips. Typical qubit measurements such as Rabi oscillations, spectroscopy, and excited-state energy relaxation are presented.
△ Less
Submitted 5 October, 2010;
originally announced October 2010.