-
In-orbit Performance of the Soft X-ray Imaging Telescope Xtend aboard XRISM
Authors:
Hiroyuki Uchida,
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Hirofumi Noda,
Takaaki Tanaka,
Hiroshi Murakami,
Hiromasa Suzuki,
Shogo Benjamin Kobayashi,
Tomokage Yoneyama,
Kouichi Hagino,
Kumiko Kawabata Nobukawa,
Hideki Uchiyama,
Masayoshi Nobukawa,
Hironori Matsumoto,
Takeshi Go Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Hirokazu Odaka,
Takayoshi Kohmura,
Kazutaka Yamaoka,
Tessei Yoshida,
Yoshiaki Kanemaru,
Daiki Ishi,
Tadayasu Dotani
, et al. (40 additional authors not shown)
Abstract:
We present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the XRISM mission, based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently-operating X-ray observatories. XRISM/Xtend has a large field of view of $38.5'\times38.5'$, covering an energy ran…
▽ More
We present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the XRISM mission, based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently-operating X-ray observatories. XRISM/Xtend has a large field of view of $38.5'\times38.5'$, covering an energy range of 0.4--13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170--180 eV at 6 keV, which meets the mission requirement and enables to resolve He-like and H-like Fe K$α$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in SXI onboard the previous Hitomi mission -- light leakage and crosstalk events -- are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C273 results in an effective area measured to be $\sim420$ cm$^{2}[email protected] keV and $\sim310$ cm$^{2}[email protected] keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations: the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared to other major X-ray instruments onboard satellites, combined with the largest grasp ($Ω_{\rm eff}\sim60$ ${\rm cm^2~degree^2}$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.
△ Less
Submitted 25 March, 2025;
originally announced March 2025.
-
Soft X-ray Imager of the Xtend system onboard XRISM
Authors:
Hirofumi Noda,
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takaaki Tanaka,
Hiroshi Murakami,
Hiroyuki Uchida,
Hiromasa Suzuki,
Shogo Benjamin Kobayashi,
Tomokage Yoneyama,
Kouichi Hagino,
Kumiko Nobukawa,
Hideki Uchiyama,
Masayoshi Nobukawa,
Hironori Matsumoto,
Takeshi Go Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Hirokazu Odaka,
Takayoshi Kohmura,
Kazutaka Yamaoka,
Tessei Yoshida,
Yoshiaki Kanemaru,
Junko Hiraga,
Tadayasu Dotani
, et al. (35 additional authors not shown)
Abstract:
The Soft X-ray Imager (SXI) is the X-ray charge-coupled device (CCD) camera for the soft X-ray imaging telescope Xtend installed on the X-ray Imaging and Spectroscopy Mission (XRISM), which was adopted as a recovery mission for the Hitomi X-ray satellite and was successfully launched on 2023 September 7 (JST). In order to maximize the science output of XRISM, we set the requirements for Xtend and…
▽ More
The Soft X-ray Imager (SXI) is the X-ray charge-coupled device (CCD) camera for the soft X-ray imaging telescope Xtend installed on the X-ray Imaging and Spectroscopy Mission (XRISM), which was adopted as a recovery mission for the Hitomi X-ray satellite and was successfully launched on 2023 September 7 (JST). In order to maximize the science output of XRISM, we set the requirements for Xtend and find that the CCD set employed in the Hitomi/SXI or similar, i.e., a $2 \times 2$ array of back-illuminated CCDs with a $200~μ$m-thick depletion layer, would be practically best among available choices, when used in combination with the X-ray mirror assembly. We design the XRISM/SXI, based on the Hitomi/SXI, to have a wide field of view of $38' \times 38'$ in the $0.4-13$ keV energy range. We incorporated several significant improvements from the Hitomi/SXI into the CCD chip design to enhance the optical-light blocking capability and to increase the cosmic-ray tolerance, reducing the degradation of charge-transfer efficiency in orbit. By the time of the launch of XRISM, the imaging and spectroscopic capabilities of the SXI has been extensively studied in on-ground experiments with the full flight-model configuration or equivalent setups and confirmed to meet the requirements. The optical blocking capability, the cooling and temperature control performance, and the transmissivity and quantum efficiency to incident X-rays of the CCDs are also all confirmed to meet the requirements. Thus, we successfully complete the pre-flight development of the SXI for XRISM.
△ Less
Submitted 11 February, 2025;
originally announced February 2025.
-
Status of Xtend telescope onboard X-Ray Imaging and Spectroscopy Mission (XRISM)
Authors:
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takashi Okajima,
Hirofumi Noda,
Hiroyuki Uchida,
Hiromasa Suzuki,
Shogo Benjamin Kobayashi,
Tomokage Yoneyama,
Kouichi Hagino,
Kumiko Nobukawa,
Takaaki Tanaka,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Hironori Matsumoto,
Takeshi Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Hirokazu Odaka,
Takayoshi Kohmura,
Kazutaka Yamaoka,
Manabu Ishida,
Yoshitomo Maeda,
Takayuki Hayashi
, et al. (38 additional authors not shown)
Abstract:
Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is…
▽ More
Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized by the combination of the SXI and XMA with a focal length of 5.6 m. The SXI employs four P-channel, back-illuminated type CCDs with a thick depletion layer of 200 $μ$m. The four CCD chips are arranged in a 2$\times$2 grid and cooled down to $-110$ $^{\circ}$C with a single-stage Stirling cooler. Before the launch of XRISM, we conducted a month-long spacecraft thermal vacuum test. The performance verification of the SXI was successfully carried out in a course of multiple thermal cycles of the spacecraft. About a month after the launch of XRISM, the SXI was carefully activated and the soundness of its functionality was checked by a step-by-step process. Commissioning observations followed the initial operation. We here present pre- and post-launch results verifying the Xtend performance. All the in-orbit performances are consistent with those measured on ground and satisfy the mission requirement. Extensive calibration studies are ongoing.
△ Less
Submitted 28 June, 2024;
originally announced June 2024.
-
Initial operations of the Soft X-ray Imager onboard XRISM
Authors:
Hiromasa Suzuki,
Tomokage Yoneyama,
Shogo B. Kobayashi,
Hirofumi Noda,
Hiroyuki Uchida,
Kumiko K. Nobukawa,
Kouichi Hagino,
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takaaki Tanaka,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Yoshiaki Kanemaru,
Yoshinori Otsuka,
Haruhiko Yokosu,
Wakana Yonemaru,
Hanako Nakano,
Kazuhiro Ichikawa,
Reo Takemoto,
Tsukasa Matsushima,
Marina Yoshimoto,
Mio Aoyagi,
Kohei Shima
, et al. (30 additional authors not shown)
Abstract:
XRISM (X-Ray Imaging and Spectroscopy Mission) is an astronomical satellite with the capability of high-resolution spectroscopy with the X-ray microcalorimeter, Resolve, and wide field-of-view imaging with the CCD camera, Xtend. Xtend consists of the mirror assembly (XMA: X-ray Mirror Assembly) and detector (SXI: Soft X-ray Imager). The SXI is composed of CCDs, analog and digital electronics, and…
▽ More
XRISM (X-Ray Imaging and Spectroscopy Mission) is an astronomical satellite with the capability of high-resolution spectroscopy with the X-ray microcalorimeter, Resolve, and wide field-of-view imaging with the CCD camera, Xtend. Xtend consists of the mirror assembly (XMA: X-ray Mirror Assembly) and detector (SXI: Soft X-ray Imager). The SXI is composed of CCDs, analog and digital electronics, and a mechanical cooler. After the successful launch on September 6th, 2023 (UT) and subsequent critical operations, the mission instruments were turned on and set up. The CCDs have been kept at the designed operating temperature of $-110^\circ$C after the electronics and cooling system were successfully set up. During the initial operation phase, which continued for more than a month after the critical operations, we verified the observation procedure, stability of the cooling system, all the observation options with different imaging areas and/or timing resolutions, and time-tagged and automated operations including those for South Atlantic Anomaly passages. We optimized the operation procedure and observation parameters including the cooler settings, imaging areas for the small window modes, and event selection algorithm. We summarize our policy and procedure of the initial operations for the SXI. We also report on a couple of issues we faced during the initial operations and lessons learned from them.
△ Less
Submitted 14 February, 2025; v1 submitted 28 June, 2024;
originally announced June 2024.