-
Broadband Optical Modulation and Control at Millikelvin Temperatures
Authors:
N. Tabassum,
T. Aralis,
J. Anczarski,
D. Baxter,
B. Cabrera,
R. Chapla,
N. Entin,
L. Hsu,
H. W. Magoon,
A. Nunez,
J. L. Ryan,
M. Salatino,
A. Simchony,
Z. J. Smith,
S. Stevens,
G. Perez,
H. Stueber,
B. A. Young,
N. A. Kurinsky,
K. Stifter
Abstract:
A universal experimental challenge when studying radiation effects on cryogenic devices is to precisely and accurately characterize the position-dependent device response very near the energy detection threshold. We have developed a compact cryogenic optical beam steering system that can be used to generate O(μs) pulses of small numbers of photons over the energy range of 1.2 - 4.5eV at room tempe…
▽ More
A universal experimental challenge when studying radiation effects on cryogenic devices is to precisely and accurately characterize the position-dependent device response very near the energy detection threshold. We have developed a compact cryogenic optical beam steering system that can be used to generate O(μs) pulses of small numbers of photons over the energy range of 1.2 - 4.5eV at room temperature, and deliver those photons via fiber optic to any specified location on the surface of a detector operating at cryogenic temperatures. This new system will allow for robust calibration of any photon-sensitive detector, including supercondcting devices. The system can be used efficiently to explore the physics of target materials, quantify the position sensitivity of different sensor designs, measure phonon transport, and study the effects of quasiparticle poisoning on detector operation. We describe the design of this pulsed calibration method and present first results obtained with a second-generation system operated at room temperature and sub-Kelvin temperatures.
△ Less
Submitted 9 April, 2025;
originally announced April 2025.
-
Characterization of a TES-based Anti-Coincidence Detector for Future Large Field-of-View X-ray Calorimetry Missions
Authors:
Samuel V. Hull,
Joseph S. Adams,
Simon R. Bandler,
Matthew Cherry,
James A. Chervenak,
Renata Cumbee,
Xavier Defay,
Enectali Figueroa-Feliciano,
Fred M. Finkbeiner,
Joshua Fuhrman,
Richard L. Kelley,
Christopher Kenney,
Caroline A. Kilbourne,
Noah Kurinsky,
Jennette Mateo,
Haruka Muramatsu,
Frederick S. Porter,
Kazuhiro Sakai,
Aviv Simchony,
Stephen J. Smith,
Zoe Smith,
Nicholas A. Wakeham,
Edward J. Wassell,
Sang H. Yoon,
Betty A. Young
Abstract:
Microcalorimeter instruments aboard future X-ray observatories will require an anti-coincidence (anti-co) detector to veto charged particle events and reduce the non-X-ray background. We have developed a large-format, TES-based prototype anti-coincidence detector that is particularly suitable for use with spatially-extended (~ 10 cm^2}) TES microcalorimeter arrays, as would be used for a future la…
▽ More
Microcalorimeter instruments aboard future X-ray observatories will require an anti-coincidence (anti-co) detector to veto charged particle events and reduce the non-X-ray background. We have developed a large-format, TES-based prototype anti-coincidence detector that is particularly suitable for use with spatially-extended (~ 10 cm^2}) TES microcalorimeter arrays, as would be used for a future large field-of-view X-ray missions. This prototype was developed in the context of the Line Emission Mapper (LEM) probe concept, which required a ~ 14 cm^2 anti-co detector with > 95% live time and a low-energy threshold below 20 keV. Our anti-co design employs parallel networks of quasiparticle-trap-assisted electrothermal feedback TESs (QETs) to detect the athermal phonon signal produced in the detector substrate by incident charged particles. We developed multiple prototype anti-co designs featuring 12 channels and up to 6300 QETs. Here we focus on a design utilizing tungsten TESs and present characterization results. Broad energy range measurements have been performed (4.1 keV -- 5.5 MeV). Based on noise and responsivity measurements, the implied low-energy threshold is < 1 keV and a live time fraction of > 96% can be achieved up to 5.5 MeV. We also find evidence of mm-scale-or-better spatial resolution and discuss the potential utility of this for future missions. Finally, we discuss the early development of a soild-state physics model of the anti-co towards understanding phonon propagation and quasiparticle production in the detector.
△ Less
Submitted 19 February, 2025;
originally announced February 2025.
-
Estimating the Masses of Supercluster-Scale Filaments from Redshift Dispersions
Authors:
Mary Crone Odekon,
Trevor W. Viscardi,
Jake Rabinowitz,
Brandon Young
Abstract:
We present a strategy for estimating the mass per unit length along supercluster-scale filaments that are oriented across the sky, based on mock redshift surveys of 264 filaments from the Millennium simulation. In our fiducial scenario, we place each simulated filament at a distance of 300 Mpc, perpendicular to the line of sight, and calculate the redshift dispersion using galaxies with magnitudes…
▽ More
We present a strategy for estimating the mass per unit length along supercluster-scale filaments that are oriented across the sky, based on mock redshift surveys of 264 filaments from the Millennium simulation. In our fiducial scenario, we place each simulated filament at a distance of 300 Mpc, perpendicular to the line of sight, and calculate the redshift dispersion using galaxies with magnitudes r<19.5. Some regions are dynamically complicated in ways that interfere with finding a simple relationship between dispersion sigma and linear mass density mu. However, by examining individual overlapping segments along the filaments, we find a relationship that allows us to successfully predict log(mu) from log(sigma) with a scatter of about +/- 0.20 dex, for ~ 70% of the regions along filaments. This relationship is robust to changes in the distance to the filament if the physical segment length and the absolute magnitude for galaxy selection are held constant. The relationship between redshift dispersion and mass is similar to that obtained for a simple analytical model where filaments are dynamically relaxed, and we examine the possibility that the galaxies are indeed relaxed within the gravitational potential of the filament. We find that this is not the case; galaxy dynamics are strongly effected by infall to the filament and by orbits within groups and clusters
△ Less
Submitted 5 December, 2024; v1 submitted 25 October, 2024;
originally announced October 2024.
-
Light Dark Matter Constraints from SuperCDMS HVeV Detectors Operated Underground with an Anticoincidence Event Selection
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. Alonso-González,
D. W. P. Amaral,
J. Anczarski,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
C. Bathurst,
R. Bhattacharyya,
A. J. Biffl,
P. L. Brink,
M. Buchanan,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
J. -H. Chen
, et al. (117 additional authors not shown)
Abstract:
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon k…
▽ More
This article presents constraints on dark-matter-electron interactions obtained from the first underground data-taking campaign with multiple SuperCDMS HVeV detectors operated in the same housing. An exposure of 7.63 g-days is used to set upper limits on the dark-matter-electron scattering cross section for dark matter masses between 0.5 and 1000 MeV/$c^2$, as well as upper limits on dark photon kinetic mixing and axion-like particle axioelectric coupling for masses between 1.2 and 23.3 eV/$c^2$. Compared to an earlier HVeV search, sensitivity was improved as a result of an increased overburden of 225 meters of water equivalent, an anticoincidence event selection, and better pile-up rejection. In the case of dark-matter-electron scattering via a heavy mediator, an improvement by up to a factor of 25 in cross-section sensitivity was achieved.
△ Less
Submitted 5 September, 2024; v1 submitted 10 July, 2024;
originally announced July 2024.
-
First measurement of the nuclear-recoil ionization yield in silicon at 100 eV
Authors:
M. F. Albakry,
I. Alkhatib,
D. Alonso,
D. W. P. Amaral,
P. An,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
P. S. Barbeau,
C. Bathurst,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (115 additional authors not shown)
Abstract:
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for furthe…
▽ More
We measured the nuclear--recoil ionization yield in silicon with a cryogenic phonon-sensitive gram-scale detector. Neutrons from a mono-energetic beam scatter off of the silicon nuclei at angles corresponding to energy depositions from 4\,keV down to 100\,eV, the lowest energy probed so far. The results show no sign of an ionization production threshold above 100\,eV. These results call for further investigation of the ionization yield theory and a comprehensive determination of the detector response function at energies below the keV scale.
△ Less
Submitted 3 March, 2023;
originally announced March 2023.
-
Electromagnetic modeling and science reach of DMRadio-m$^3$
Authors:
DMRadio Collaboration,
A. AlShirawi,
V. Ankel,
C. Bartram,
J. Begin,
C. Bell,
J. N. Benabou,
L. Brouwer,
S. Chaudhuri,
H. -M. Cho,
J. Corbin,
W. Craddock,
S. Cuadra,
A. Droster,
J. Echevers,
J. W. Foster,
J. T. Fry,
P. W. Graham,
R. Henning,
K. D. Irwin,
F. Kadribasic,
Y. Kahn,
A. Keller,
R. Kolevatov,
S. Kuenstner
, et al. (23 additional authors not shown)
Abstract:
DMRadio-m$^3$ is an experiment that is designed to be sensitive to KSVZ and DFSZ QCD axion models in the 10--200\,MHz (41 neV$/c^2$ -- 0.83 $μ$eV/$c^2$) range. The experiment uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. In this work, we pres…
▽ More
DMRadio-m$^3$ is an experiment that is designed to be sensitive to KSVZ and DFSZ QCD axion models in the 10--200\,MHz (41 neV$/c^2$ -- 0.83 $μ$eV/$c^2$) range. The experiment uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. In this work, we present the electromagnetic modeling of the response of the experiment to an axion signal over the full frequency range of DMRadio-m$^3$, which extends from the low-frequency, lumped-element limit to a regime where the axion Compton wavelength is only a factor of two larger than the detector size. With these results, we determine the live time and sensitivity of the experiment. The primary science goal of sensitivity to DFSZ axions across 30--200 MHz can be achieved with a $3σ$ live scan time of 2.9 years.
△ Less
Submitted 6 May, 2025; v1 submitted 27 February, 2023;
originally announced February 2023.
-
Migrating Thermal Tides in the Martian Atmosphere during Aphelion Season Observed by EMM/EMIRS
Authors:
Siteng Fan,
François Forget,
Michael D. Smith,
Sandrine Guerlet,
Khalid M. Badri,
Samuel A. Atwood,
Roland M. B. Young,
Christopher S. Edwards,
Philip R. Christensen,
Justin Deighan,
Hessa R. Al Matroushi,
Antoine Bierjon,
Jiandong Liu,
Ehouarn Millour
Abstract:
Temperature profiles retrieved using the first set of data of the Emirates Mars InfraRed Spectrometer (EMIRS) obtained during the science phase of the Emirates Mars Mission (EMM) are used for the analysis of migrating thermal tides in the Martian atmosphere. The selected data cover a solar longitude (LS) range of 60°-90° of Martian Year (MY) 36. The novel orbit design of the Hope Probe leads to a…
▽ More
Temperature profiles retrieved using the first set of data of the Emirates Mars InfraRed Spectrometer (EMIRS) obtained during the science phase of the Emirates Mars Mission (EMM) are used for the analysis of migrating thermal tides in the Martian atmosphere. The selected data cover a solar longitude (LS) range of 60°-90° of Martian Year (MY) 36. The novel orbit design of the Hope Probe leads to a good geographic and local time coverage that significantly improves the analysis. Wave mode decomposition suggests dominant diurnal tide and important semi-diurnal tide with maximal amplitudes of 6K and 2K, respectively, as well as the existence of ~0.5K ter-diurnal tide. The results agree well with predictions by the Mars Planetary Climate Model (PCM), but the observed diurnal tide has an earlier phase (3h), and the semi-diurnal tide has an unexpectedly large wavelength (~200km).
△ Less
Submitted 4 September, 2022;
originally announced September 2022.
-
Effective Field Theory Analysis of CDMSlite Run 2 Data
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott
, et al. (105 additional authors not shown)
Abstract:
CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected back…
▽ More
CDMSlite Run 2 was a search for weakly interacting massive particles (WIMPs) with a cryogenic 600 g Ge detector operated in a high-voltage mode to optimize sensitivity to WIMPs of relatively low mass from 2 - 20 GeV/$c^2$. In this article, we present an effective field theory (EFT) analysis of the CDMSlite Run 2 data using an extended energy range and a comprehensive treatment of the expected background. A binned likelihood Bayesian analysis was performed on the recoil energy data, taking into account the parameters of the EFT interactions and optimizing the data selection with respect to the dominant background components. Energy regions within 5$σ$ of known activation peaks were removed from the analysis. The Bayesian evidences resulting from the different operator hypotheses show that the CDMSlite Run 2 data are consistent with the background-only models and do not allow for a signal interpretation assuming any additional EFT interaction. Consequently, upper limits on the WIMP mass and coupling-coefficient amplitudes and phases are presented for each EFT operator. These limits improve previous CDMSlite Run 2 bounds for WIMP masses above 5 GeV/$c^2$.
△ Less
Submitted 23 May, 2022;
originally announced May 2022.
-
Investigating the sources of low-energy events in a SuperCDMS-HVeV detector
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (104 additional authors not shown)
Abstract:
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS…
▽ More
Recent experiments searching for sub-GeV/$c^2$ dark matter have observed event excesses close to their respective energy thresholds. Although specific to the individual technologies, the measured excess event rates have been consistently reported at or below event energies of a few-hundred eV, or with charges of a few electron-hole pairs. In the present work, we operated a 1-gram silicon SuperCDMS-HVeV detector at three voltages across the crystal (0 V, 60 V and 100 V). The 0 V data show an excess of events in the tens of eV region. Despite this event excess, we demonstrate the ability to set a competitive exclusion limit on the spin-independent dark matter--nucleon elastic scattering cross section for dark matter masses of $\mathcal{O}(100)$ MeV/$c^2$, enabled by operation of the detector at 0 V potential and achievement of a very low $\mathcal{O}(10)$ eV threshold for nuclear recoils. Comparing the data acquired at 0 V, 60 V and 100 V potentials across the crystal, we investigated possible sources of the unexpected events observed at low energy. The data indicate that the dominant contribution to the excess is consistent with a hypothesized luminescence from the printed circuit boards used in the detector holder.
△ Less
Submitted 11 October, 2022; v1 submitted 17 April, 2022;
originally announced April 2022.
-
Axion Dark Matter
Authors:
C. B. Adams,
N. Aggarwal,
A. Agrawal,
R. Balafendiev,
C. Bartram,
M. Baryakhtar,
H. Bekker,
P. Belov,
K. K. Berggren,
A. Berlin,
C. Boutan,
D. Bowring,
D. Budker,
A. Caldwell,
P. Carenza,
G. Carosi,
R. Cervantes,
S. S. Chakrabarty,
S. Chaudhuri,
T. Y. Chen,
S. Cheong,
A. Chou,
R. T. Co,
J. Conrad,
D. Croon
, et al. (130 additional authors not shown)
Abstract:
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synerg…
▽ More
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.
△ Less
Submitted 29 March, 2023; v1 submitted 28 March, 2022;
originally announced March 2022.
-
New Horizons: Scalar and Vector Ultralight Dark Matter
Authors:
D. Antypas,
A. Banerjee,
C. Bartram,
M. Baryakhtar,
J. Betz,
J. J. Bollinger,
C. Boutan,
D. Bowring,
D. Budker,
D. Carney,
G. Carosi,
S. Chaudhuri,
S. Cheong,
A. Chou,
M. D. Chowdhury,
R. T. Co,
J. R. Crespo López-Urrutia,
M. Demarteau,
N. DePorzio,
A. V. Derbin,
T. Deshpande,
M. D. Chowdhury,
L. Di Luzio,
A. Diaz-Morcillo,
J. M. Doyle
, et al. (104 additional authors not shown)
Abstract:
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical,…
▽ More
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.
△ Less
Submitted 28 March, 2022;
originally announced March 2022.
-
A Strategy for Low-Mass Dark Matter Searches with Cryogenic Detectors in the SuperCDMS SNOLAB Facility
Authors:
SuperCDMS Collaboration,
M. F. Albakry,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
C. Bathurst,
D. A. Bauer,
R. Bhattacharyya,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen,
N. Chott,
J. Cooley
, et al. (103 additional authors not shown)
Abstract:
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-ba…
▽ More
The SuperCDMS Collaboration is currently building SuperCDMS SNOLAB, a dark matter search focused on nucleon-coupled dark matter in the 1-5 GeV/c$^2$ mass range. Looking to the future, the Collaboration has developed a set of experience-based upgrade scenarios, as well as novel directions, to extend the search for dark matter using the SuperCDMS technology in the SNOLAB facility. The experienced-based scenarios are forecasted to probe many square decades of unexplored dark matter parameter space below 5 GeV/c$^2$, covering over 6 decades in mass: 1-100 eV/c$^2$ for dark photons and axion-like particles, 1-100 MeV/c$^2$ for dark-photon-coupled light dark matter, and 0.05-5 GeV/c$^2$ for nucleon-coupled dark matter. They will reach the neutrino fog in the 0.5-5 GeV/c$^2$ mass range and test a variety of benchmark models and sharp targets. The novel directions involve greater departures from current SuperCDMS technology but promise even greater reach in the long run, and their development must begin now for them to be available in a timely fashion.
The experienced-based upgrade scenarios rely mainly on dramatic improvements in detector performance based on demonstrated scaling laws and reasonable extrapolations of current performance. Importantly, these improvements in detector performance obviate significant reductions in background levels beyond current expectations for the SuperCDMS SNOLAB experiment. Given that the dominant limiting backgrounds for SuperCDMS SNOLAB are cosmogenically created radioisotopes in the detectors, likely amenable only to isotopic purification and an underground detector life-cycle from before crystal growth to detector testing, the potential cost and time savings are enormous and the necessary improvements much easier to prototype.
△ Less
Submitted 1 April, 2023; v1 submitted 16 March, 2022;
originally announced March 2022.
-
Thermal structure and aerosols in Mars' atmosphere from TIRVIM/ACS onboard the ExoMars Trace Gas Orbiter : validation of the retrieval algorithm
Authors:
Sandrine Guerlet,
N. Ignatiev,
F. Forget,
T. Fouchet,
P. Vlasov,
G. Bergeron,
R. M. B. Young,
E. Millour,
S. Fan,
H. Tran,
A. Shakun,
A. Grigoriev,
A. Trokhimovskiy,
F. Montmessin,
O. Korablev
Abstract:
The Atmospheric Chemistry Suite (ACS) onboard the ExoMars Trace Gas Orbiter (TGO) monitors the Martian atmosphere through different spectral intervals in the infrared light. We present a retrieval algorithm tailored to the analysis of spectra acquired in nadir geometry by TIRVIM, the thermal infrared channel of ACS. Our algorithm simultaneously retrieves vertical profile of atmospheric temperature…
▽ More
The Atmospheric Chemistry Suite (ACS) onboard the ExoMars Trace Gas Orbiter (TGO) monitors the Martian atmosphere through different spectral intervals in the infrared light. We present a retrieval algorithm tailored to the analysis of spectra acquired in nadir geometry by TIRVIM, the thermal infrared channel of ACS. Our algorithm simultaneously retrieves vertical profile of atmospheric temperature up to 50 km, surface temperature, and integrated optical depth of dust and water ice clouds. The specificity of the TIRVIM dataset lies in its capacity to resolve the diurnal cycle over a 54 sol period. However, it is uncertain to what extent can the desired atmospheric quantities be accurately estimated at different times of day. Here we first present an Observing System Simulation Experiment (OSSE). We produce synthetic observations at various latitudes, seasons and local times and run our retrieval algorithm on these synthetic data, to evaluate its robustness. Different sources of biases are documented, in particular regarding aerosol retrievals. Atmospheric temperature retrievals are found robust even when dust and/or water ice cloud opacities are not well estimated in our OSSE. We then apply our algorithm to TIRVIM observations in April-May, 2018 and perform a cross-validation of retrieved atmospheric temperature and dust integrated opacity by comparisons with thousands of co-located Mars Climate Sounder (MCS) retrievals. Most differences between TIRVIM and MCS atmospheric temperatures can be attributed to differences in vertical sensitivity. Daytime dust opacities agree well with each other, while biases are found in nighttime dust opacity retrieved from TIRVIM at this season.
△ Less
Submitted 27 January, 2022;
originally announced January 2022.
-
Constraints on Lightly Ionizing Particles from CDMSlite
Authors:
SuperCDMS Collaboration,
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (93 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the v…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) achieved efficient detection of very small recoil energies in its germanium target, resulting in sensitivity to Lightly Ionizing Particles (LIPs) in a previously unexplored region of charge, mass, and velocity parameter space. We report first direct-detection limits calculated using the optimum interval method on the vertical intensity of cosmogenically-produced LIPs with an electric charge smaller than $e/(3\times10^5$), as well as the strongest limits for charge $\leq e/160$, with a minimum vertical intensity of $1.36\times10^{-7}$\,cm$^{-2}$s$^{-1}$sr$^{-1}$ at charge $e/160$. These results apply over a wide range of LIP masses (5\,MeV/$c^2$ to 100\,TeV/$c^2$) and cover a wide range of $βγ$ values (0.1 -- $10^6$), thus excluding non-relativistic LIPs with $βγ$ as small as 0.1 for the first time.
△ Less
Submitted 19 February, 2022; v1 submitted 18 November, 2020;
originally announced November 2020.
-
Light Dark Matter Search with a High-Resolution Athermal Phonon Detector Operated Above Ground
Authors:
I. Alkhatib,
D. W. P. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
I. Ataee Langroudy,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
M. Chaudhuri,
R. Chen
, et al. (99 additional authors not shown)
Abstract:
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matte…
▽ More
We present limits on spin-independent dark matter-nucleon interactions using a $10.6$ $\mathrm{g}$ Si athermal phonon detector with a baseline energy resolution of $σ_E=3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.19}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$. This exclusion analysis sets the most stringent dark matter-nucleon scattering cross-section limits achieved by a cryogenic detector for dark matter particle masses from $93$ to $140$ $\mathrm{MeV}/c^2$, with a raw exposure of $9.9$ $\mathrm{g}\cdot\mathrm{d}$ acquired at an above-ground facility. This work illustrates the scientific potential of detectors with athermal phonon sensors with eV-scale energy resolution for future dark matter searches.
△ Less
Submitted 12 October, 2021; v1 submitted 21 July, 2020;
originally announced July 2020.
-
Measuring Mars Atmospheric Winds From Orbit
Authors:
Scott Guzewich J. B. Abshire. M. M. Baker,
J. M. Battalio,
T. Bertrand,
A. J. Brown,
A. Colaprete,
A. M. Cook,
D. R. Cremons,
M. M. Crismani,
A. I. Dave,
M. Day,
M. -C. Desjean,
M. Elrod,
L. K. Fenton,
J. Fisher,
L. L. Gordley,
P. O. Hayne,
N. G. Heavens,
J. L. Hollingsworth,
D. Jha,
V. Jha,
M. A. Kahre,
A. SJ. Khayat,
A. M. Kling,
S. R. Lewis,
B. T. Marshall
, et al. (16 additional authors not shown)
Abstract:
Wind is the process that connects Mars' climate system. Measurements of Mars atmospheric winds from orbit would dramatically advance our understanding of Mars and help prepare for human exploration of the Red Planet. Multiple instrument candidates are in development and will be ready for flight in the next decade. We urge the Decadal Survey to make these measurements a priority for 2023-2032.
Wind is the process that connects Mars' climate system. Measurements of Mars atmospheric winds from orbit would dramatically advance our understanding of Mars and help prepare for human exploration of the Red Planet. Multiple instrument candidates are in development and will be ready for flight in the next decade. We urge the Decadal Survey to make these measurements a priority for 2023-2032.
△ Less
Submitted 10 July, 2020;
originally announced July 2020.
-
Search For Electron-Antineutrinos Associated With Gravitational-Wave Events GW150914, GW151012, GW151226, GW170104, GW170608, GW170814, and GW170817 at Daya Bay
Authors:
F. P. An,
A. B. Balantekin,
H. R. Band,
M. Bishai,
S. Blyth,
G. F. Cao,
J. Cao,
J. F. Chang,
Y. Chang,
H. S. Chen,
S. M. Chen,
Y. Chen,
Y. X. Chen,
J. Cheng,
Z. K. Cheng,
J. J. Cherwinka,
M. C. Chu,
J. P. Cummings,
O. Dalager,
F. S. Deng,
Y. Y. Ding,
M. V. Diwan,
T. Dohnal,
J. Dove,
M. Dvorak
, et al. (161 additional authors not shown)
Abstract:
Providing a possible connection between neutrino emission and gravitational-wave (GW) bursts is important to our understanding of the physical processes that occur when black holes or neutron stars merge. In the Daya Bay experiment, using data collected from December 2011 to August 2017, a search has been performed for electron-antineutrino signals coinciding with detected GW events, including GW1…
▽ More
Providing a possible connection between neutrino emission and gravitational-wave (GW) bursts is important to our understanding of the physical processes that occur when black holes or neutron stars merge. In the Daya Bay experiment, using data collected from December 2011 to August 2017, a search has been performed for electron-antineutrino signals coinciding with detected GW events, including GW150914, GW151012, GW151226, GW170104, GW170608, GW170814, and GW170817. We used three time windows of $\mathrm{\pm 10~s}$, $\mathrm{\pm 500~s}$, and $\mathrm{\pm 1000~s}$ relative to the occurrence of the GW events, and a neutrino energy range of 1.8 to 100 MeV to search for correlated neutrino candidates. The detected electron-antineutrino candidates are consistent with the expected background rates for all the three time windows. Assuming monochromatic spectra, we found upper limits (90% confidence level) on electron-antineutrino fluence of $(1.13~-~2.44) \times 10^{11}~\rm{cm^{-2}}$ at 5 MeV to $8.0 \times 10^{7}~\rm{cm^{-2}}$ at 100 MeV for the three time windows. Under the assumption of a Fermi-Dirac spectrum, the upper limits were found to be $(5.4~-~7.0)\times 10^{9}~\rm{cm^{-2}}$ for the three time windows.
△ Less
Submitted 14 September, 2020; v1 submitted 27 June, 2020;
originally announced June 2020.
-
Constraints on low-mass, relic dark matter candidates from a surface-operated SuperCDMS single-charge sensitive detector
Authors:
SuperCDMS Collaboration,
D. W. Amaral,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
S. Banik,
D. Barker,
C. Bathurst,
D. A. Bauer,
L. V. S. Bezerra,
R. Bhattacharyya,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
R. Chen,
N. Chott,
J. Cooley
, et al. (94 additional authors not shown)
Abstract:
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a…
▽ More
This article presents an analysis and the resulting limits on light dark matter inelastically scattering off of electrons, and on dark photon and axion-like particle absorption, using a second-generation SuperCDMS high-voltage eV-resolution detector. The 0.93 gram Si detector achieved a 3 eV phonon energy resolution; for a detector bias of 100 V, this corresponds to a charge resolution of 3% of a single electron-hole pair. The energy spectrum is reported from a blind analysis with 1.2 gram-days of exposure acquired in an above-ground laboratory. With charge carrier trapping and impact ionization effects incorporated into the dark matter signal models, the dark matter-electron cross section $\barσ_{e}$ is constrained for dark matter masses from 0.5--$10^{4} $MeV$/c^{2}$; in the mass range from 1.2--50 eV$/c^{2}$ the dark photon kinetic mixing parameter $\varepsilon$ and the axioelectric coupling constant $g_{ae}$ are constrained. The minimum 90% confidence-level upper limits within the above mentioned mass ranges are $\barσ_{e}\,=\,8.7\times10^{-34}$ cm$^{2}$, $\varepsilon\,=\,3.3\times10^{-14}$, and $g_{ae}\,=\,1.0\times10^{-9}$.
△ Less
Submitted 29 January, 2021; v1 submitted 28 May, 2020;
originally announced May 2020.
-
The turbulent dynamics of Jupiter's and Saturn's weather layers: order out of chaos?
Authors:
Peter L Read,
Roland M B Young,
Daniel Kennedy
Abstract:
The weather layers of the gas giant planets, Jupiter and Saturn, comprise the shallow atmospheric layers that are influenced energetically by a combination of incoming solar radiation and localised latent heating of condensates, as well as by upwelling heat from their planetary interiors. They are also the most accessible regions of those planets to direct observations. Recent analyses in Oxford o…
▽ More
The weather layers of the gas giant planets, Jupiter and Saturn, comprise the shallow atmospheric layers that are influenced energetically by a combination of incoming solar radiation and localised latent heating of condensates, as well as by upwelling heat from their planetary interiors. They are also the most accessible regions of those planets to direct observations. Recent analyses in Oxford of cloud-tracked winds on Jupiter have demonstrated that kinetic energy is injected into the weather layer at scales comparable to the Rossby radius of deformation and cascades both upscale, mostly into the extra-tropical zonal jets, and downscale to the smallest resolvable scales in Cassini images. The large-scale flow on both Jupiter and Saturn appears to equilibrate towards a state which is close to marginal instability according to Arnol'd's 2nd stability theorem. This scenario is largely reproduced in a hierarchy of numerical models of giant planet weather layers, including relatively realistic models which seek to predict thermal and dynamical structures using a full set of parameterisations of radiative transfer, interior heat sources and even moist convection. Such models include the Jason GCM, developed in Oxford, which also represents the formation of (energetically passive) clouds of NH3, NH4SH and H2O condensates and the transport of condensable tracers. Recent results show some promise in comparison with observations from the Cassini and Juno missions, but some observed features (such as Jupiter's Great Red Spot and other compact ovals) are not yet captured spontaneously by any weather layer model. We review recent work in this vein and discuss a number of open questions for future study.
△ Less
Submitted 6 April, 2020;
originally announced April 2020.
-
Global climate modeling of Saturn's atmosphere. Part III: Global statistical picture of zonostrophic turbulence in high-resolution 3D-turbulent simulations
Authors:
Simon,
Cabanes,
Aymeric,
Spiga,
Roland,
M. B. Young
Abstract:
We conduct an in-depth analysis of statistical flow properties calculated from the reference high-resolution Saturn simulation obtained by global climate modelling in Part II. In the steady state of this reference simulation, strongly energetic, zonally dominated, large-scale structures emerge, which scale with the Rhines scale. Spectral analysis reveals a strong anisotropy in the kinetic energy s…
▽ More
We conduct an in-depth analysis of statistical flow properties calculated from the reference high-resolution Saturn simulation obtained by global climate modelling in Part II. In the steady state of this reference simulation, strongly energetic, zonally dominated, large-scale structures emerge, which scale with the Rhines scale. Spectral analysis reveals a strong anisotropy in the kinetic energy spectra, consistent with the zonostrophic turbulent flow regime. By computing spectral energy and enstrophy fluxes we confirm the existence of a double cascade scenario related to 2D-turbulent theory. To diagnose the relevant 3D dynamical mechanisms in Saturn's turbulent atmosphere, we run a set of four simulations using an idealized version of our Global Climate Model devoid of radiative transfer, with a well-defined Taylor-Green forcing and over several rotation rates (4, 1, 0.5, and 0.25 times Saturn's rotation rate). This allows us to identify dynamics in three distinctive inertial ranges: (1) a ``residual-dominated'' range, in which non-axisymmetric structures dominate with a -5/3 spectral slope; (2) a ``zonostrophic inertial'' range, dominated by axisymmetric jets and characterized by the pile-up of strong zonal modes with a steeper, nearly -3, spectral slope; and (3) a ``large-scale'' range, beyond Rhines' typical length scale, in which the reference Saturn simulation and our idealized simulations differ. In the latter range, the dynamics is dominated by long-lived zonal modes 2 and 3 when a Saturn-like seasonal forcing is considered (reference simulation), and a steep energetic decrease with the idealized Taylor-Green forcing. Finally, instantaneous spectral fluxes show the coexistence of upscale and downscale enstrophy/energy transfers at large scales, specific to the regime of zonostrophic turbulence in a 3D atmosphere.
△ Less
Submitted 8 January, 2020;
originally announced January 2020.
-
Exclusion Limits on Hidden-Photon Dark Matter near 2 neV from a Fixed-Frequency Superconducting Lumped-Element Resonator
Authors:
A. Phipps,
S. E. Kuenstner,
S. Chaudhuri,
C. S. Dawson,
B. A. Young,
C. T. FitzGerald,
H. Froland,
K. Wells,
D. Li,
H. M. Cho,
S. Rajendran,
P. W. Graham,
K. D. Irwin
Abstract:
We present the design and performance of a simple fixed-frequency superconducting lumped-element resonator developed for axion and hidden photon dark matter detection. A rectangular NbTi inductor was coupled to a Nb-coated sapphire capacitor and immersed in liquid helium within a superconducting shield. The resonator was transformer-coupled to a DC SQUID for readout. We measured a quality factor o…
▽ More
We present the design and performance of a simple fixed-frequency superconducting lumped-element resonator developed for axion and hidden photon dark matter detection. A rectangular NbTi inductor was coupled to a Nb-coated sapphire capacitor and immersed in liquid helium within a superconducting shield. The resonator was transformer-coupled to a DC SQUID for readout. We measured a quality factor of $\sim$40,000 at the resonant frequency of 492.027 kHz and set a simple exclusion limit on $\sim$2 neV hidden photons with kinetic mixing angle $\varepsilon\gtrsim1.5\times10^{-9}$ based on 5.14 hours of integrated noise. This test device informs the development of the Dark Matter Radio, a tunable superconducting lumped-element resonator which will search for axions and hidden photons over the 100 Hz to 300 MHz frequency range.
△ Less
Submitted 20 June, 2019;
originally announced June 2019.
-
Search for Low-Mass Dark Matter with CDMSlite Using a Profile Likelihood Fit
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
R. A. Cameron,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
F. De Brienne,
T. Doughty
, et al. (78 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than…
▽ More
The Cryogenic Dark Matter Search low ionization threshold experiment (CDMSlite) searches for interactions between dark matter particles and germanium nuclei in cryogenic detectors. The experiment has achieved a low energy threshold with improved sensitivity to low-mass (<10 GeV/c$^2$) dark matter particles. We present an analysis of the final CDMSlite data set, taken with a different detector than was used for the two previous CDMSlite data sets. This analysis includes a data "salting" method to protect against bias, improved noise discrimination, background modeling, and the use of profile likelihood methods to search for a dark matter signal in the presence of backgrounds. We achieve an energy threshold of 70 eV and significantly improve the sensitivity for dark matter particles with masses between 2.5 and 10 GeV/c$^2$ compared to previous analyses. We set an upper limit on the dark matter-nucleon scattering cross section in germanium of 5.4$\times$10$^{-42}$ cm$^2$ at 5 GeV/c$^2$, a factor of $\sim$2.5 improvement over the previous CDMSlite result.
△ Less
Submitted 2 January, 2021; v1 submitted 27 August, 2018;
originally announced August 2018.
-
Production Rate Measurement of Tritium and Other Cosmogenic Isotopes in Germanium with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
T. Doughty,
E. Fascione,
E. Figueroa-Feliciano,
C. W. Fink
, et al. (73 additional authors not shown)
Abstract:
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected prod…
▽ More
Future direct searches for low-mass dark matter particles with germanium detectors, such as SuperCDMS SNOLAB, are expected to be limited by backgrounds from radioactive isotopes activated by cosmogenic radiation inside the germanium. There are limited experimental data available to constrain production rates and a large spread of theoretical predictions. We examine the calculation of expected production rates, and analyze data from the second run of the CDMS low ionization threshold experiment (CDMSlite) to estimate the rates for several isotopes. We model the measured CDMSlite spectrum and fit for contributions from tritium and other isotopes. Using the knowledge of the detector history, these results are converted to cosmogenic production rates at sea level. The production rates in atoms/(kg$\cdot$day) are 74$\pm$9 for $^3$H, 1.5$\pm$0.7 for $^{55}$Fe, 17$\pm$5 for $^{65}$Zn, and 30$\pm$18 for $^{68}$Ge.
△ Less
Submitted 16 August, 2019; v1 submitted 19 June, 2018;
originally announced June 2018.
-
Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS Germanium Detectors
Authors:
Robert Agnese,
Taylor Aralis,
Tsuguo Aramaki,
Isaac Arnquist,
Elham Azadbakht,
William Baker,
Samir Banik,
D'Ann Barker,
Dan Bauer,
Thomas Binder,
Michael Bowles,
Paul Brink,
Ray Bunker,
Blas Cabrera,
Robert Calkins,
Concetta Cartaro,
David Cerdeno,
Yen-Yung Chang,
Jodi Cooley,
Brett Cornell,
Priscilla Cushman,
Philippe Di Stefano,
Todd Doughty,
Eleanor Fascione,
Tali Figueroa
, et al. (72 additional authors not shown)
Abstract:
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which w…
▽ More
The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this result and using TRIM simulations, we extract the first experimentally determined average displacement threshold energy of $\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for the analysis thresholds of future germanium-based dark matter searches.
△ Less
Submitted 16 April, 2019; v1 submitted 24 May, 2018;
originally announced May 2018.
-
SLAC Microresonator Radio Frequency (SMuRF) Electronics for Read Out of Frequency-Division-Multiplexed Cryogenic Sensors
Authors:
S. A. Kernasovskiy,
S. E. Kuenstner,
E. Karpel,
Z. Ahmed,
D. D. Van Winkle,
S. Smith,
J. Dusatko,
J. C. Frisch,
S. Chaudhuri,
H. M. Cho,
B. J. Dober,
S. W. Henderson,
G. C. Hilton,
J. Hubmayr,
K. D. Irwin,
C. L. Kuo,
D. Li,
J. A. B. Mates,
M. Nasr,
S. Tantawi,
J. Ullom,
L. Vale,
B. Young
Abstract:
Large arrays of cryogenic sensors for various imaging applications ranging across x-ray, gamma-ray, Cosmic Microwave Background (CMB), mm/sub-mm, as well as particle detection increasingly rely on superconducting microresonators for high multiplexing factors. These microresonators take the form of microwave SQUIDs that couple to Transition-Edge Sensors (TES) or Microwave Kinetic Inductance Detecto…
▽ More
Large arrays of cryogenic sensors for various imaging applications ranging across x-ray, gamma-ray, Cosmic Microwave Background (CMB), mm/sub-mm, as well as particle detection increasingly rely on superconducting microresonators for high multiplexing factors. These microresonators take the form of microwave SQUIDs that couple to Transition-Edge Sensors (TES) or Microwave Kinetic Inductance Detectors (MKIDs). In principle, such arrays can be read out with vastly scalable software-defined radio using suitable FPGAs, ADCs and DACs. In this work, we share plans and show initial results for SLAC Microresonator Radio Frequency (SMuRF) electronics, a next-generation control and readout system for superconducting microresonators. SMuRF electronics are unique in their implementation of specialized algorithms for closed-loop tone tracking, which consists of fast feedback and feedforward to each resonator's excitation parameters based on transmission measurements. Closed-loop tone tracking enables improved system linearity, a significant increase in sensor count per readout line, and the possibility of overcoupled resonator designs for enhanced dynamic range. Low-bandwidth prototype electronics were used to demonstrate closed-loop tone tracking on twelve 300-kHz-wide microwave SQUID resonators, spaced at $\sim$6 MHz with center frequencies $\sim$5-6 GHz. We achieve multi-kHz tracking bandwidth and demonstrate that the noise floor of the electronics is subdominant to the noise intrinsic in the multiplexer.
△ Less
Submitted 21 May, 2018;
originally announced May 2018.
-
First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector
Authors:
SuperCDMS Collaboration,
R. Agnese,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
E. Azadbakht,
W. Baker,
S. Banik,
D. Barker,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. -Y. Chang,
J. Cooley,
B. Cornell,
P. Cushman,
P. C. F. Di Stefano,
T. Doughty,
E. Fascione
, et al. (77 additional authors not shown)
Abstract:
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensit…
▽ More
We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensitivity to dark photons competitive with other leading approaches but using substantially less exposure (0.49 gram days). These results demonstrate the scientific potential of phonon-mediated semiconductor detectors that are sensitive to single electronic excitations.
△ Less
Submitted 22 December, 2020; v1 submitted 27 April, 2018;
originally announced April 2018.
-
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
W. Baker,
D. Balakishiyeva,
S. Banik,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
H. Chagani,
Y. -Y. Chang,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman
, et al. (84 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absol…
▽ More
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum $^{252}$Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at $\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.
△ Less
Submitted 27 July, 2018; v1 submitted 7 March, 2018;
originally announced March 2018.
-
Low-Mass Dark Matter Search with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. Chang,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell
, et al. (83 additional authors not shown)
Abstract:
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is…
▽ More
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses $\lesssim$3 GeV/$c^2$
△ Less
Submitted 18 January, 2018; v1 submitted 6 July, 2017;
originally announced July 2017.
-
Design Overview of the DM Radio Pathfinder Experiment
Authors:
Maximiliano Silva-Feaver,
Saptarshi Chaudhuri,
Hsiao-Mei Cho,
Carl Dawson,
Peter Graham,
Kent Irwin,
Stephen Kuenstner,
Dale Li,
Jeremy Mardon,
Harvey Moseley,
Richard Mule,
Arran Phipps,
Surjeet Rajendran,
Zach Steffen,
Betty Young
Abstract:
We introduce the DM Radio, a dual search for axion and hidden photon dark matter using a tunable superconducting lumped-element resonator. We discuss the prototype DM Radio Pathfinder experiment, which will probe hidden photons in the 500 peV (100 kHz)-50 neV (10 MHz) mass range. We detail the design of the various components: the LC resonant detector, the resonant frequency tuning procedure, the…
▽ More
We introduce the DM Radio, a dual search for axion and hidden photon dark matter using a tunable superconducting lumped-element resonator. We discuss the prototype DM Radio Pathfinder experiment, which will probe hidden photons in the 500 peV (100 kHz)-50 neV (10 MHz) mass range. We detail the design of the various components: the LC resonant detector, the resonant frequency tuning procedure, the differential SQUID readout circuit, the shielding, and the cryogenic mounting structure. We present the current status of the pathfinder experiment and illustrate its potential science reach in the context of the larger experimental program.
△ Less
Submitted 28 October, 2016;
originally announced October 2016.
-
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
I. Arnquist,
W. Baker,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty
, et al. (71 additional authors not shown)
Abstract:
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle…
▽ More
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be present in the detectors at some level. Even if these backgrounds are x10 higher than expected, the science reach of the HV detectors would be over three orders of magnitude beyond current results for a dark matter mass of 1 GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the "neutrino floor", where coherent scatters of solar neutrinos become a limiting background.
△ Less
Submitted 30 September, 2016;
originally announced October 2016.
-
WIMP-Search Results from the Second CDMSlite Run
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aramaki,
M. Asai,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal
, et al. (65 additional authors not shown)
Abstract:
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization…
▽ More
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
△ Less
Submitted 9 March, 2016; v1 submitted 8 September, 2015;
originally announced September 2015.
-
Improved WIMP-search reach of the CDMS II germanium data
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
D. G. Cerdeño,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano
, et al. (64 additional authors not shown)
Abstract:
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days germanium-detector WIMP-search exposure. An extended analysis was also completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to increase sensitivity n…
▽ More
CDMS II data from the 5-tower runs at the Soudan Underground Laboratory were reprocessed with an improved charge-pulse fitting algorithm. Two new analysis techniques to reject surface-event backgrounds were applied to the 612 kg days germanium-detector WIMP-search exposure. An extended analysis was also completed by decreasing the 10 keV analysis threshold to $\sim$5 keV, to increase sensitivity near a WIMP mass of 8 GeV/$c^2$. After unblinding, there were zero candidate events above a deposited energy of 10 keV and 6 events in the lower-threshold analysis. This yielded minimum WIMP-nucleon spin-independent scattering cross-section limits of $1.8 \times 10^{-44}$ and $1.18 \times 10 ^{-41}$ cm$^2$ at 90\% confidence for 60 and 8.6 GeV/$c^2$ WIMPs, respectively. This improves the previous CDMS II result by a factor of 2.4 (2.7) for 60 (8.6) GeV/$c^2$ WIMPs.
△ Less
Submitted 13 October, 2015; v1 submitted 22 April, 2015;
originally announced April 2015.
-
Dark matter effective field theory scattering in direct detection experiments
Authors:
K. Schneck,
B. Cabrera,
D. G. Cerdeno,
V. Mandic,
H. E. Rogers,
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
D. Brandt,
P. L. Brink,
R. Bunker,
D. O. Caldwell,
R. Calkins,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman
, et al. (62 additional authors not shown)
Abstract:
We examine the consequences of the effective field theory (EFT) of dark matter-nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter paramete…
▽ More
We examine the consequences of the effective field theory (EFT) of dark matter-nucleon scattering for current and proposed direct detection experiments. Exclusion limits on EFT coupling constants computed using the optimum interval method are presented for SuperCDMS Soudan, CDMS II, and LUX, and the necessity of combining results from multiple experiments in order to determine dark matter parameters is discussed. We demonstrate that spectral differences between the standard dark matter model and a general EFT interaction can produce a bias when calculating exclusion limits and when developing signal models for likelihood and machine learning techniques. We also discuss the implications of the EFT for the next-generation (G2) direct detection experiments and point out regions of complementarity in the EFT parameter space.
△ Less
Submitted 16 August, 2016; v1 submitted 11 March, 2015;
originally announced March 2015.
-
Effects of Shock Waves on Neutrino Oscillations in Three Supernova Models
Authors:
Jing Xu,
Li-Jun Hu,
Rui-Cheng Li,
Xin-Heng Guo,
Bing-Lin Young
Abstract:
It has been realized that the shock wave effects play an important role in neutrino oscillations during the supernova explosion. In recent years, with the development of simulations about supernova explosion, we have a better understanding about the density profiles and the shock waves in supernovae than before. It has been shown that the appearance of shock waves not only varies with time, but is…
▽ More
It has been realized that the shock wave effects play an important role in neutrino oscillations during the supernova explosion. In recent years, with the development of simulations about supernova explosion, we have a better understanding about the density profiles and the shock waves in supernovae than before. It has been shown that the appearance of shock waves not only varies with time, but is also affected by the mass of the supernova. When the mass of the supernova happens to be in a certain range (e.g. it equals 10.8 times the mass of the sun), there might be a reverse shock wave, another sudden change of density except the forward shock wave, emerging in the supernova. In addition, there are some other time-dependent changes of density profiles in different supernova models. Because of these complex density profiles, the expression of the crossing probability at the high resonance, $P_H$, which we used previously would be no longer applicable. In order to get more accurate and reasonable results, we use the data of density profiles in three different supernova models obtained from simulations to study the variations of $P_s$ (the survival probability of $ν_e\rightarrowν_e$), as well as $P_c$ (the conversion probability of $ν_x\rightarrowν_e$). It is found that the mass of the supernova does make a difference on the behavior of $P_s$, and affects $P_c$ at the same time. With the results of $P_s$ and $P_c$, we can estimate the number of $ν_e$ remained after they go through the matter in the supernova.
△ Less
Submitted 22 December, 2014;
originally announced December 2014.
-
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban
, et al. (62 additional authors not shown)
Abstract:
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background…
▽ More
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. We confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.
△ Less
Submitted 3 October, 2014;
originally announced October 2014.
-
First direct limits on Lightly Ionizing Particles with electric charge less than $e/6$
Authors:
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban,
S. Fallows
, et al. (60 additional authors not shown)
Abstract:
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six…
▽ More
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six stacked detectors of each of two of the CDMS II towers found no candidates, thereby excluding new parameter space for particles with electric charges between $e$/6 and $e$/200.
△ Less
Submitted 3 February, 2015; v1 submitted 10 September, 2014;
originally announced September 2014.
-
Search for Low-Mass WIMPs with SuperCDMS
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Beaty,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
M. Cherry,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
D. DeVaney
, et al. (70 additional authors not shown)
Abstract:
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is i…
▽ More
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6 GeV/c2.
△ Less
Submitted 12 March, 2014; v1 submitted 28 February, 2014;
originally announced February 2014.
-
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban,
S. Fallows
, et al. (55 additional authors not shown)
Abstract:
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were coll…
▽ More
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were collected with a single 0.6 kg germanium detector running for 10 live days at the Soudan Underground Laboratory. A low energy threshold of 170 eVee (electron equivalent) was obtained, which allows us to constrain new WIMP-nucleon spin-independent parameter space for WIMP masses below 6 GeV/c2.
△ Less
Submitted 20 December, 2013; v1 submitted 12 September, 2013;
originally announced September 2013.
-
Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches
Authors:
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
M. Cherry,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
E. Do Couto E Silva,
T. Doughty,
L. Esteban,
S. Fallows,
E. Figueroa-Feliciano
, et al. (66 additional authors not shown)
Abstract:
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were teste…
▽ More
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were tested with two $^{210}$Pb sources producing $\sim$130 beta decays/hr. In $\sim$800 live hours, no events leaked into the 8--115 keV signal region, giving upper limit leakage fraction $1.7 \times 10^{-5}$ at 90% C.L., corresponding to $< 0.6$ surface event background in the future 200-kg SuperCDMS SNOLAB experiment.
△ Less
Submitted 4 October, 2013; v1 submitted 10 May, 2013;
originally announced May 2013.
-
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
Authors:
CDMS Collaboration,
R. Agnese,
Z. Ahmed,
A. J. Anderson,
S. Arrenberg,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
D. Brandt,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
F. Dejongh,
E. Do Couto E Silva
, et al. (66 additional authors not shown)
Abstract:
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206P…
▽ More
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90% confidence level, respectively. The exposure of this analysis is equivalent to 23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10 GeV/c2. The probability that the known backgrounds would produce three or more events in the signal region is 5.4%. A profile likelihood ratio test of the three events that includes the measured recoil energies gives a 0.19% probability for the known-background-only hypothesis when tested against the alternative WIMP+background hypothesis. The highest likelihood occurs for a WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
△ Less
Submitted 11 October, 2013; v1 submitted 15 April, 2013;
originally announced April 2013.
-
Silicon detector results from the first five-tower run of CDMS II
Authors:
CDMS Collaboration,
R. Agnese,
Z. Ahmed,
A. J. Anderson,
S. Arrenberg,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
D. Brandt,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
F. Dejongh,
P. C. F. Di Stefano,
E. do Couto e Silva
, et al. (65 additional authors not shown)
Abstract:
We report results of a search for Weakly Interacting Massive Particles (WIMPs) with the Si detectors of the CDMS II experiment. This report describes a blind analysis of the first data taken with CDMS II's full complement of detectors in 2006-2007; results from this exposure using the Ge detectors have already been presented. We observed no candidate WIMP-scattering events in an exposure of 55.9 k…
▽ More
We report results of a search for Weakly Interacting Massive Particles (WIMPs) with the Si detectors of the CDMS II experiment. This report describes a blind analysis of the first data taken with CDMS II's full complement of detectors in 2006-2007; results from this exposure using the Ge detectors have already been presented. We observed no candidate WIMP-scattering events in an exposure of 55.9 kg-days before analysis cuts, with an expected background of ~1.1 events. The exposure of this analysis is equivalent to 10.3 kg-days over a recoil energy range of 7-100 keV for an ideal Si detector and a WIMP mass of 10 GeV/c2. These data set an upper limit of 1.7x10-41 cm2 on the WIMP-nucleon spin-independent cross section of a 10 GeV/c2 WIMP. These data exclude parameter space for spin-independent WIMP-nucleon elastic scattering that is relevant to recent searches for low-mass WIMPs.
△ Less
Submitted 14 September, 2013; v1 submitted 12 April, 2013;
originally announced April 2013.
-
Search for annual modulation in low-energy CDMS-II data
Authors:
CDMS Collaboration,
Z. Ahmed,
D. S. Akerib,
A. J. Anderson,
S. Arrenberg,
C. N. Bailey,
D. Balakishiyeva,
L. Baudis,
D. A. Bauer,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
J. Cooley,
P. Cushman,
M. Daal,
F. DeJongh,
P. C. F. Di Stefano,
M. R. Dragowsky,
S. Fallows,
E. Figueroa-Feliciano,
J. Filippini,
J. Fox,
M. Fritts
, et al. (42 additional authors not shown)
Abstract:
We report limits on annual modulation of the low-energy event rate from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Such a modulation could be produced by interactions from Weakly Interacting Massive Particles (WIMPs) with masses ~10 GeV/c^2. We find no evidence for annual modulation in the event rate of veto-anticoincident single-detector interactio…
▽ More
We report limits on annual modulation of the low-energy event rate from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Such a modulation could be produced by interactions from Weakly Interacting Massive Particles (WIMPs) with masses ~10 GeV/c^2. We find no evidence for annual modulation in the event rate of veto-anticoincident single-detector interactions consistent with nuclear recoils, and constrain the magnitude of any modulation to <0.06 event [keVnr kg day]^-1 in the 5-11.9 keVnr energy range at the 99% confidence level. These results disfavor an explanation for the reported modulation in the 1.2-3.2 keVee energy range in CoGeNT in terms of nuclear recoils resulting from elastic scattering of WIMPs at >98% confidence. For events consistent with electron recoils, no significant modulation is observed for either single- or multiple-detector interactions in the 3.0-7.4 keVee range.
△ Less
Submitted 18 September, 2012; v1 submitted 6 March, 2012;
originally announced March 2012.
-
Modeling phase-separated transition-edge sensors in SuperCDMS detectors
Authors:
A. J. Anderson,
S. W. Leman,
T. Doughty,
E. Figueroa-Feliciano,
K. A. McCarthy,
M. Pyle,
B. A. Young
Abstract:
The SuperCDMS experiment implements transition-edge sensors to measure athermal phonons produced by nuclear recoils in Ge crystals. We discuss a numerical simulation of these TES devices and a procedure for tuning the free model parameters to data, which reproduces superconducting-to-normal phase separation within a TES. This tuning provides insight into the behavior of the TESs, allows us to stud…
▽ More
The SuperCDMS experiment implements transition-edge sensors to measure athermal phonons produced by nuclear recoils in Ge crystals. We discuss a numerical simulation of these TES devices and a procedure for tuning the free model parameters to data, which reproduces superconducting-to-normal phase separation within a TES. This tuning provides insight into the behavior of the TESs, allows us to study the phase-separation length to optimize our detector design, and is integrated into a more complete simulation of the phonon and charge physics of SuperCDMS detectors.
△ Less
Submitted 23 September, 2011; v1 submitted 16 September, 2011;
originally announced September 2011.
-
Simulations of Noise in Phase-Separated Transition-Edge Sensors for SuperCDMS
Authors:
A. J. Anderson,
S. W. Leman,
M. Pyle,
E. Figueroa-Feliciano,
K. McCarthy,
T. Doughty,
M. Cherry,
B. Young
Abstract:
We briefly review a simple model of superconducting-normal phase-separation in transition-edge sensors in the SuperCDMS experiment. After discussing some design considerations relevant to the TES in the detectors, we study noise sources in both the phase-separated and phase-uniform cases. Such simulations are valuable for optimizing the critical temperature and TES length of future SuperCDMS detec…
▽ More
We briefly review a simple model of superconducting-normal phase-separation in transition-edge sensors in the SuperCDMS experiment. After discussing some design considerations relevant to the TES in the detectors, we study noise sources in both the phase-separated and phase-uniform cases. Such simulations are valuable for optimizing the critical temperature and TES length of future SuperCDMS detectors.
△ Less
Submitted 6 September, 2011;
originally announced September 2011.
-
Monte Carlo Comparisons to a Cryogenic Dark Matter Search Detector with low Transition-Edge-Sensor Transition Temperature
Authors:
S. W. Leman,
K. A. McCarthy,
P. L. Brink,
B. Cabrera,
M. Cherry,
E. Do Couto E Silva,
E. Figueroa-Feliciano,
P. Kim,
N. Mirabolfathi,
M. Pyle,
R. Resch,
B. Sadoulet,
B. Serfass,
K. M. Sundqvist,
A. Tomada,
B. A. Young
Abstract:
We present results on phonon quasidiffusion and Transition Edge Sensor (TES) studies in a large, 3 inch diameter, 1 inch thick [100] high purity germanium crystal, cooled to 50 mK in the vacuum of a dilution refrigerator, and exposed with 59.5 keV gamma-rays from an Am-241 calibration source. We compare calibration data with results from a Monte Carlo which includes phonon quasidiffusion and the g…
▽ More
We present results on phonon quasidiffusion and Transition Edge Sensor (TES) studies in a large, 3 inch diameter, 1 inch thick [100] high purity germanium crystal, cooled to 50 mK in the vacuum of a dilution refrigerator, and exposed with 59.5 keV gamma-rays from an Am-241 calibration source. We compare calibration data with results from a Monte Carlo which includes phonon quasidiffusion and the generation of phonons created by charge carriers as they are drifted across the detector by ionization readout channels. The phonon energy is then parsed into TES based phonon readout channels and input into a TES simulator.
△ Less
Submitted 6 September, 2011;
originally announced September 2011.
-
Time Evolution of Electric Fields in CDMS Detectors
Authors:
S. W. Leman,
D. Brandt,
P. L. Brink,
B. Cabrera,
H. Chagani,
M. Cherry,
P. Cushman,
E. Do Couto E Silva,
T. Doughty,
E. Figueroa-Feliciano,
V. Mandic,
K. A. McCarthy,
N. Mirabolfathi,
M. Pyle,
A. Reisetter,
R. Resch,
B. Sadoulet,
B. Serfass,
K. M. Sundqvist,
A. Tomada,
B. A. Young,
J. Zhang
Abstract:
The Cryogenic Dark Matter Search (CDMS) utilizes large mass, 3" diameter x 1" thick target masses as particle detectors. The target is instrumented with both phonon and ionization sensors, the later providing a $\sim$1 V cm$^{-1}$ electric field in the detector bulk. Cumulative radiation exposure which creates $\sim 200\times 10^6$ electron-hole pairs is sufficient to produce a comparable reverse…
▽ More
The Cryogenic Dark Matter Search (CDMS) utilizes large mass, 3" diameter x 1" thick target masses as particle detectors. The target is instrumented with both phonon and ionization sensors, the later providing a $\sim$1 V cm$^{-1}$ electric field in the detector bulk. Cumulative radiation exposure which creates $\sim 200\times 10^6$ electron-hole pairs is sufficient to produce a comparable reverse field in the detector thereby degrading the ionization channel performance. To study this, the existing CDMS detector Monte Carlo has been modified to allow for an event by event evolution of the bulk electric field, in three spatial dimensions. Our most resent results and interpretation are discussed.
△ Less
Submitted 31 August, 2011;
originally announced August 2011.
-
Combined Limits on WIMPs from the CDMS and EDELWEISS Experiments
Authors:
CDMS,
EDELWEISS Collaborations,
:,
Z. Ahmed,
D. S. Akerib,
E. Armengaud,
S. Arrenberg,
C. Augier,
C. N. Bailey,
D. Balakishiyeva,
L. Baudis,
D. A. Bauer,
A. Benoît,
L. Bergé,
J. Blümer,
P. L. Brink,
A. Broniatowski,
T. Bruch,
V. Brudanin,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
B. Censier,
M. Chapellier,
G. Chardin
, et al. (92 additional authors not shown)
Abstract:
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon…
▽ More
The CDMS and EDELWEISS collaborations have combined the results of their direct searches for dark matter using cryogenic germanium detectors. The total data set represents 614 kg.d equivalent exposure. A straightforward method of combination was chosen for its simplicity before data were exchanged between experiments. The results are interpreted in terms of limits on spin-independent WIMP-nucleon cross-section. For a WIMP mass of 90 GeV/c^2, where this analysis is most sensitive, a cross-section of 3.3 x 10^{-44} cm^2 is excluded at 90% CL. At higher WIMP masses, the combination improves the individual limits, by a factor 1.6 above 700 GeV/c^2. Alternative methods of combining the data provide stronger constraints for some ranges of WIMP masses and weaker constraints for others.
△ Less
Submitted 8 July, 2011; v1 submitted 17 May, 2011;
originally announced May 2011.
-
Search for inelastic dark matter with the CDMS II experiment
Authors:
CDMS Collaboration,
Z. Ahmed,
D. S. Akerib,
S. Arrenberg,
C. N. Bailey,
D. Balakishiyeva,
L. Baudis,
D. A. Bauer,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
J. Cooley,
E. do Couto e Silva,
P. Cushman,
M. Daal,
F. DeJongh,
P. Di Stefano,
M. R. Dragowsky,
L. Duong,
S. Fallows,
E. Figueroa-Feliciano,
J. Filippini,
J. Fox
, et al. (41 additional authors not shown)
Abstract:
Results are presented from a reanalysis of the entire five-tower data set acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis window was extended to a recoil energy of 150 keV, and an improved surface-event background-rejection cut was defined to increase the sensitivity of the experiment to the ine…
▽ More
Results are presented from a reanalysis of the entire five-tower data set acquired with the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory, with an exposure of 969 kg-days. The analysis window was extended to a recoil energy of 150 keV, and an improved surface-event background-rejection cut was defined to increase the sensitivity of the experiment to the inelastic dark matter (iDM) model. Three dark matter candidates were found between 25 keV and 150 keV. The probability to observe three or more background events in this energy range is 11%. Because of the occurrence of these events the constraints on the iDM parameter space are slightly less stringent than those from our previous analysis, which used an energy window of 10-100 keV.
△ Less
Submitted 12 June, 2011; v1 submitted 22 December, 2010;
originally announced December 2010.
-
Results from a Low-Energy Analysis of the CDMS II Germanium Data
Authors:
CDMS Collaboration,
Z. Ahmed,
D. S. Akerib,
S. Arrenberg,
C. N. Bailey,
D. Balakishiyeva,
L. Baudis,
D. A. Bauer,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
J. Cooley,
E. do Couto e Silva,
P. Cushman,
M. Daal,
F. DeJongh,
P. Di Stefano,
M. R. Dragowsky,
L. Duong,
S. Fallows,
E. Figueroa-Feliciano,
J. Filippini,
J. Fox
, et al. (40 additional authors not shown)
Abstract:
We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs) with masses below…
▽ More
We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from Weakly Interacting Massive Particles (WIMPs) with masses below ~10 GeV/c^2. This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9 GeV/c^2 and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.
△ Less
Submitted 21 April, 2011; v1 submitted 10 November, 2010;
originally announced November 2010.
-
Low-threshold analysis of CDMS shallow-site data
Authors:
CDMS Collaboration,
D. S. Akerib,
M. J. Attisha,
L. Baudis,
D. A. Bauer,
A. I. Bolozdynya,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
C. L. Chang,
R. M. Clarke,
J. Cooley,
M. B. Crisler,
P. Cushman,
F. DeJongh,
R. Dixon,
D. D. Driscoll,
J. Filippini,
S. Funkhouser,
R. J. Gaitskell,
S. R. Golwala,
D. Holmgren,
L. Hsu,
M. E. Huber
, et al. (23 additional authors not shown)
Abstract:
Data taken during the final shallow-site run of the first tower of the Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with improved sensitivity to small energy depositions. Four ~224 g germanium and two ~105 g silicon detectors were operated at the Stanford Underground Facility (SUF) between December 2001 and June 2002, yielding 118 live days of raw exposure. Three of the ge…
▽ More
Data taken during the final shallow-site run of the first tower of the Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with improved sensitivity to small energy depositions. Four ~224 g germanium and two ~105 g silicon detectors were operated at the Stanford Underground Facility (SUF) between December 2001 and June 2002, yielding 118 live days of raw exposure. Three of the germanium and both silicon detectors were analyzed with a new low-threshold technique, making it possible to lower the germanium and silicon analysis thresholds down to the actual trigger thresholds of ~1 keV and ~2 keV, respectively. Limits on the spin-independent cross section for weakly interacting massive particles (WIMPs) to elastically scatter from nuclei based on these data exclude interesting parameter space for WIMPs with masses below 9 GeV/c^2. Under standard halo assumptions, these data partially exclude parameter space favored by interpretations of the DAMA/LIBRA and CoGeNT experiments' data as WIMP signals, and exclude new parameter space for WIMP masses between 3 GeV/c^2 and 4 GeV/c^2.
△ Less
Submitted 3 January, 2011; v1 submitted 20 October, 2010;
originally announced October 2010.