-
Development of MMC-based lithium molybdate cryogenic calorimeters for AMoRE-II
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
H. Bae,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
S. Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Y. M. Gavrilyuk,
A. M. Gezhaev
, et al. (84 additional authors not shown)
Abstract:
The AMoRE collaboration searches for neutrinoless double beta decay of $^{100}$Mo using molybdate scintillating crystals via low temperature thermal calorimetric detection. The early phases of the experiment, AMoRE-pilot and AMoRE-I, have demonstrated competitive discovery potential. Presently, the AMoRE-II experiment, featuring a large detector array with about 90 kg of $^{100}$Mo isotope, is und…
▽ More
The AMoRE collaboration searches for neutrinoless double beta decay of $^{100}$Mo using molybdate scintillating crystals via low temperature thermal calorimetric detection. The early phases of the experiment, AMoRE-pilot and AMoRE-I, have demonstrated competitive discovery potential. Presently, the AMoRE-II experiment, featuring a large detector array with about 90 kg of $^{100}$Mo isotope, is under construction. This paper discusses the baseline design and characterization of the lithium molybdate cryogenic calorimeters to be used in the AMoRE-II detector modules. The results from prototype setups that incorporate new housing structures and two different crystal masses (316 g and 517 - 521 g), operated at 10 mK temperature, show energy resolutions (FWHM) of 7.55 - 8.82 keV at the 2.615 MeV $^{208}$Tl $γ$ line, and effective light detection of 0.79 - 0.96 keV/MeV. The simultaneous heat and light detection enables clear separation of alpha particles with a discrimination power of 12.37 - 19.50 at the energy region around $^6$Li(n, $α$)$^3$H with Q-value = 4.785 MeV. Promising detector performances were demonstrated at temperatures as high as 30 mK, which relaxes the temperature constraints for operating the large AMoRE-II array.
△ Less
Submitted 3 March, 2025; v1 submitted 16 July, 2024;
originally announced July 2024.
-
Pulse shape discrimination in an organic scintillation phoswich detector using machine learning techniques
Authors:
Yujin Lee,
Jinyoung Kim,
Byoung-cheol Koh,
Young Soo Yoon,
Chang Hyon Ha
Abstract:
We developed machine learning algorithms for distinguishing scintillation signals from a plastic-liquid coupled detector known as a phoswich. The challenge lies in discriminating signals from organic scintillators with similar shapes and short decay times. Using a single-readout phoswich detector, we successfully identified $γ$ radiation signals from two scintillating components. Our Boosted Decis…
▽ More
We developed machine learning algorithms for distinguishing scintillation signals from a plastic-liquid coupled detector known as a phoswich. The challenge lies in discriminating signals from organic scintillators with similar shapes and short decay times. Using a single-readout phoswich detector, we successfully identified $γ$ radiation signals from two scintillating components. Our Boosted Decision Tree algorithm demonstrated a maximum discrimination power of 3.02 $\pm$ 0.85 standard deviation in the 950 keV region, providing an efficient solution for self-shielding and enhancing radiation detection capabilities.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Alpha backgrounds in the AMoRE-Pilot experiment
Authors:
V. Alenkov,
H. W. Bae,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun,
S. H. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. Gezhaev,
V. D. Grigoryeva,
V. Gurentsov,
D. H. Ha,
C. Ha,
E. J. Ha,
I. Hahn,
E. J. Jeon
, et al. (81 additional authors not shown)
Abstract:
The Advanced Mo-based Rare process Experiment (AMoRE)-Pilot experiment is an initial phase of the AMoRE search for neutrinoless double beta decay of $^{100}$Mo, with the purpose of investigating the level and sources of backgrounds. Searches for neutrinoless double beta decay generally require ultimately low backgrounds. Surface $α$ decays on the crystals themselves or nearby materials can deposit…
▽ More
The Advanced Mo-based Rare process Experiment (AMoRE)-Pilot experiment is an initial phase of the AMoRE search for neutrinoless double beta decay of $^{100}$Mo, with the purpose of investigating the level and sources of backgrounds. Searches for neutrinoless double beta decay generally require ultimately low backgrounds. Surface $α$ decays on the crystals themselves or nearby materials can deposit a continuum of energies that can be as high as the $Q$-value of the decay itself and may fall in the region of interest (ROI). To understand these background events, we studied backgrounds from radioactive contaminations internal to and on the surface of the crystals or nearby materials with Geant4-based Monte Carlo simulations. In this study, we report on the measured $α$ energy spectra fitted with the corresponding simulated spectra for six crystal detectors, where sources of background contributions could be identified through high energy $α$ peaks and continuum parts in the energy spectrum for both internal and surface contaminations. We determine the low-energy contributions from internal and surface $α$ contaminations by extrapolating from the $α$ background fitting model.
△ Less
Submitted 5 December, 2022; v1 submitted 16 July, 2021;
originally announced July 2021.
-
Proton and Helium Spectra from the CREAM-III Flight
Authors:
Y. S. Yoon,
T. Anderson,
A. Barrau,
N. B. Conklin,
S. Coutu,
L. Derome,
J. H. Han,
J. A. Jeon,
K. C. Kim,
M. H. Kim,
H. Y. Lee,
J. Lee,
M. H. Lee,
S. E. Lee,
J. T. Link,
A. Menchaca-Rocha,
J. W. Mitchell,
S. I. Mognet,
S. Nutter,
I. H. Park,
N. Picot-Clemente,
A. Putze,
E. S. Seo,
J. Smith,
J. Wu
Abstract:
Primary cosmic-ray elemental spectra have been measured with the balloon-borne Cosmic Ray Energetics And Mass (CREAM) experiment since 2004. The third CREAM payload (CREAM-III) flew for 29 days during the 2007-2008 Antarctic season. Energies of incident particles above 1 TeV are measured with a calorimeter. Individual elements are clearly separated with a charge resolution of ~0.12 e (in charge un…
▽ More
Primary cosmic-ray elemental spectra have been measured with the balloon-borne Cosmic Ray Energetics And Mass (CREAM) experiment since 2004. The third CREAM payload (CREAM-III) flew for 29 days during the 2007-2008 Antarctic season. Energies of incident particles above 1 TeV are measured with a calorimeter. Individual elements are clearly separated with a charge resolution of ~0.12 e (in charge units) and ~0.14 e for protons and helium nuclei, respectively, using two layers of silicon charge detectors. The measured proton and helium energy spectra at the top of the atmosphere are harder than other existing measurements at a few tens of GeV. The relative abundance of protons to helium nuclei is 9.53+-0.03 for the range of 1 TeV/n to 63 TeV/n. The ratio is considerably smaller than other measurements at a few tens of GeV/n. The spectra become softer above ~20 TeV. However, our statistical uncertainties are large at these energies and more data are needed.
△ Less
Submitted 8 April, 2017;
originally announced April 2017.
-
Search for solar axions with CsI(Tl) crystal detectors
Authors:
KIMS Collaboration,
Y. S. Yoon,
H. K. Park,
H. Bhang,
J. H. Choi,
S. Choi,
I. S. Hahn,
E. J. Jeon,
H. W. Joo,
W. G. Kang,
B. H. Kim,
G. B. Kim,
H. J. Kim,
K. W. Kim,
S. C. Kim,
S. K. Kim,
Y. D. Kim,
Y. H. Kim,
H. S. Lee,
J. H. Lee,
J. K. Lee,
S. J. Lee,
D. S. Leonard,
J. Li,
S. S. Myung
, et al. (2 additional authors not shown)
Abstract:
The results of a search for solar axions from the Korea Invisible Mass Search (KIMS) experiment at the Yangyang Underground Laboratory are presented. Low-energy electron-recoil events would be produced by conversion of solar axions into electrons via the axio-electric effect in CsI(Tl) crystals. Using data from an exposure of 34,596 $\rm kg \cdot days$, we set a 90 \% confidence level upper limit…
▽ More
The results of a search for solar axions from the Korea Invisible Mass Search (KIMS) experiment at the Yangyang Underground Laboratory are presented. Low-energy electron-recoil events would be produced by conversion of solar axions into electrons via the axio-electric effect in CsI(Tl) crystals. Using data from an exposure of 34,596 $\rm kg \cdot days$, we set a 90 \% confidence level upper limit on the axion-electron coupling, $g_{ae}$, of $1.39 \times 10^{-11}$ for an axion mass less than 1 keV/$\rm c^2$. This limit is lower than the indirect solar neutrino bound, and fully excludes QCD axions heavier than 0.48 eV/$\rm c^2$ and 140.9 eV/$\rm c^2$ for the DFSZ and KSVZ models respectively.
△ Less
Submitted 23 May, 2016; v1 submitted 6 April, 2016;
originally announced April 2016.
-
Understanding internal backgrounds of NaI(Tl) crystals toward a 200~kg array for the KIMS-NaI experiment
Authors:
P. Adhikari,
G. Adhikari,
S. Choi,
C. Ha,
I. S. Hahn,
E. J. Jeon,
H. W. Joo,
W. G. Kang,
H. J. Kim,
H. O. Kim,
K. W. Kim,
N. Y. Kim,
S. K. Kim,
Y. D. Kim,
Y. H. Kim,
H. S. Lee,
J. H. Lee,
M. H. Lee,
D. S. Leonard,
J. Li,
S. Y. Oh,
S. L. Olsen,
H. K. Park,
H. S. Park,
K. S. Park
, et al. (2 additional authors not shown)
Abstract:
The Korea Invisible Mass Search (KIMS) collaboration has developed low-background NaI(Tl) crystals that are suitable for the direct detection of WIMP dark matter. With experience built on the KIMS-CsI programs, the KIMS-NaI experiment will consist of a 200~kg NaI(Tl) crystal array surrounded by layers of shielding structures and will be operated at the Yangyang underground laboratory. The goal is…
▽ More
The Korea Invisible Mass Search (KIMS) collaboration has developed low-background NaI(Tl) crystals that are suitable for the direct detection of WIMP dark matter. With experience built on the KIMS-CsI programs, the KIMS-NaI experiment will consist of a 200~kg NaI(Tl) crystal array surrounded by layers of shielding structures and will be operated at the Yangyang underground laboratory. The goal is to provide an unambiguous test of the DAMA/LIBRA's annual modulation signature. Measurements of six prototype crystals show progress in the reduction of internal contaminations of radioisotopes. Based on our understanding of these measurements, we expect to achieve a background level in the final detector configuration that is less than 1~count/day/keV/kg for recoil energies around 2~keV. The annual modulation sensitivity for the KIMS-NaI experiment shows that an unambiguous 7$σ$ test of the DAMA/LIBRA signature would be possible with a 600~kg$\cdot$year exposure with this system.
△ Less
Submitted 17 March, 2016; v1 submitted 15 October, 2015;
originally announced October 2015.
-
Design and construction of a Cherenkov imager for charge measurement of nuclear cosmic rays
Authors:
O. Bourrion,
Ch. Bernard,
D. Bondoux,
J. L. Bouly,
J. Bouvier,
B. Boyer,
M. Brinet,
M. Buenerd,
G. Damieux,
L. Derome,
L. Eraud,
R. Foglio,
D. Fombaron,
D. Grondin,
M. H. Lee,
L. Lutz,
M. Marton,
A. Menchaca-Rocha,
A. Pelissier,
J. N. Périé,
A. Putze,
S. Roudier,
Y. Sallaz-Damaz,
E. S. Seo,
J. P. Scordilis
, et al. (1 additional authors not shown)
Abstract:
A proximity focusing Cherenkov imager called CHERCAM, has been built for the charge measurement of nuclear cosmic rays with the CREAM instrument. It consists of a silica aerogel radiator plane across from a detector plane equipped with 1,600 1" diameter photomultipliers. The two planes are separated by a ring expansion gap. The Cherenkov light yield is proportional to the charge squared of the inc…
▽ More
A proximity focusing Cherenkov imager called CHERCAM, has been built for the charge measurement of nuclear cosmic rays with the CREAM instrument. It consists of a silica aerogel radiator plane across from a detector plane equipped with 1,600 1" diameter photomultipliers. The two planes are separated by a ring expansion gap. The Cherenkov light yield is proportional to the charge squared of the incident particle. The expected relative light collection accuracy is in the few percents range. It leads to an expected single element separation over the range of nuclear charge Z of main interest 1 < Z < 26. CHERCAM is designed to fly with the CREAM balloon experiment. The design of the instrument and the implemented technical solutions allowing its safe operation in high altitude conditions (radiations, low pressure, cold) are presented.
△ Less
Submitted 18 May, 2011; v1 submitted 7 March, 2011;
originally announced March 2011.
-
Cosmic-Ray Proton and Helium Spectra from the First CREAM Flight
Authors:
Y. S. Yoon,
H. S. Ahn,
P. S. Allison,
M. G. Bagliesi,
J. J. Beatty,
G. Bigongiari,
P. J. Boyle,
J. T. Childers,
N. B. Conklin,
S. Coutu,
M. A. DuVernois,
O. Ganel,
J. H. Han,
J. A. Jeon,
K. C. Kim,
M. H. Lee,
L. Lutz,
P. Maestro,
A. Malinine,
P. S. Marrocchesi,
S. A. Minnick,
S. I. Mognet,
S. Nam,
S. Nutter,
I. H. Park
, et al. (9 additional authors not shown)
Abstract:
Cosmic-ray proton and helium spectra have been measured with the balloon-borne Cosmic Ray Energetics And Mass experiment flown for 42 days in Antarctica in the 2004-2005 austral summer season. High-energy cosmic-ray data were collected at an average altitude of ~38.5 km with an average atmospheric overburden of ~3.9 g cm$^{-2}$. Individual elements are clearly separated with a charge resolution of…
▽ More
Cosmic-ray proton and helium spectra have been measured with the balloon-borne Cosmic Ray Energetics And Mass experiment flown for 42 days in Antarctica in the 2004-2005 austral summer season. High-energy cosmic-ray data were collected at an average altitude of ~38.5 km with an average atmospheric overburden of ~3.9 g cm$^{-2}$. Individual elements are clearly separated with a charge resolution of ~0.15 e (in charge units) and ~0.2 e for protons and helium nuclei, respectively. The measured spectra at the top of the atmosphere are represented by power laws with a spectral index of -2.66 $\pm$ 0.02 for protons from 2.5 TeV to 250 TeV and -2.58 $\pm$ 0.02 for helium nuclei from 630 GeV/nucleon to 63 TeV/nucleon. They are harder than previous measurements at a few tens of GeV/nucleon. The helium flux is higher than that expected from the extrapolation of the power law fitted to the lower-energy data. The relative abundance of protons to helium nuclei is 9.1 $\pm$ 0.5 for the range from 2.5 TeV/nucleon to 63 TeV/nucleon. This ratio is considerably smaller than the previous measurements at a few tens of GeV/nucleon.
△ Less
Submitted 13 February, 2011;
originally announced February 2011.
-
Discrepant hardening observed in cosmic-ray elemental spectra
Authors:
H. S. Ahn,
P. Allison,
M. G. Bagliesi,
J. J. Beatty,
G. Bigongiari,
J. T. Childers,
N. B. Conklin,
S. Coutu,
M. A. DuVernois,
O. Ganel,
J. H. Han,
J. A. Jeon,
K. C. Kim,
M. H. Lee,
L. Lutz,
P. Maestro,
A. Malinin,
P. S. Marrocchesi,
S. Minnick,
S. I. Mognet,
J. Nam,
S. Nam,
S. L. Nutter,
I. H. Park,
N. H. Park
, et al. (7 additional authors not shown)
Abstract:
The balloon-borne Cosmic Ray Energetics And Mass (CREAM) experiment launched five times from Antarctica has achieved a cumulative flight duration of about 156 days above 99.5% of the atmosphere. The instrument is configured with complementary and redundant particle detectors designed to extend direct measurements of cosmic-ray composition to the highest energies practical with balloon flights. All…
▽ More
The balloon-borne Cosmic Ray Energetics And Mass (CREAM) experiment launched five times from Antarctica has achieved a cumulative flight duration of about 156 days above 99.5% of the atmosphere. The instrument is configured with complementary and redundant particle detectors designed to extend direct measurements of cosmic-ray composition to the highest energies practical with balloon flights. All elements from protons to iron nuclei are separated with excellent charge resolution. Here we report results from the first two flights of ~70 days, which indicate hardening of the elemental spectra above ~200 GeV/nucleon and a spectral difference between the two most abundant species, protons and helium nuclei. These results challenge the view that cosmic-ray spectra are simple power laws below the so-called knee at ~1015 eV. This discrepant hardening may result from a relatively nearby source, or it could represent spectral concavity caused by interactions of cosmic rays with the accelerating shock. Other possible explanations should also be investigated.
△ Less
Submitted 7 April, 2010;
originally announced April 2010.
-
Elemental energy spectra of cosmic rays measured by CREAM-II
Authors:
P. Maestro,
H. S. Ahn,
P. Allison,
M. G. Bagliesi,
L. Barbier,
J. J. Beatty,
G. Bigongiari,
T. J. Brandt,
J. T. Childers,
N. B. Conklin,
S. Coutu,
M. A. DuVernois,
O. Ganel,
J. H. Han,
J. A. Jeon,
K. C. Kim,
M. H. Lee,
A. Malinine,
P. S. Marrocchesi,
S. Minnick,
S. I. Mognet,
S. W. Nam,
S. Nutter,
I. H. Park,
N. H. Park
, et al. (8 additional authors not shown)
Abstract:
We present new measurements of the energy spectra of cosmic-ray (CR) nuclei from the second flight of the balloon-borne experiment CREAM (Cosmic Ray Energetics And Mass). The instrument (CREAM-II) was comprised of detectors based on different techniques (Cherenkov light, specific ionization in scintillators and silicon sensors) to provide a redundant charge identification and a thin ionization cal…
▽ More
We present new measurements of the energy spectra of cosmic-ray (CR) nuclei from the second flight of the balloon-borne experiment CREAM (Cosmic Ray Energetics And Mass). The instrument (CREAM-II) was comprised of detectors based on different techniques (Cherenkov light, specific ionization in scintillators and silicon sensors) to provide a redundant charge identification and a thin ionization calorimeter capable of measuring the energy of cosmic rays up to several hundreds of TeV. The data analysis is described and the individual energy spectra of C, O, Ne, Mg, Si and Fe are reported up to ~ 10^14 eV. The spectral shape looks nearly the same for all the primary elements and can be expressed as a power law in energy E^{-2.66+/-0.04}. The nitrogen absolute intensity in the energy range 100-800 GeV/n is also measured.
△ Less
Submitted 30 March, 2010;
originally announced March 2010.
-
Measurements of cosmic-ray energy spectra with the 2nd CREAM flight
Authors:
P. Maestro,
H. S. Ahn,
P. Allison,
M. G. Bagliesi,
L. Barbier,
J. J. Beatty,
G. Bigongiari,
T. J. Brandt,
J. T. Childers,
N. B. Conklin,
S. Coutu,
M. A. DuVernois,
O. Ganel,
J. H. Han,
J. A. Jeon,
K. C. Kim,
M. H. Lee,
A. Malinine,
P. S. Marrocchesi,
S. Minnick,
S. I. Mognet,
S. W. Nam,
S. Nutter,
I. H. Park,
N. H. Park
, et al. (8 additional authors not shown)
Abstract:
During its second Antarctic flight, the CREAM (Cosmic Ray Energetics And Mass) balloon experiment collected data for 28 days, measuring the charge and the energy of cosmic rays (CR) with a redundant system of particle identification and an imaging thin ionization calorimeter. Preliminary direct measurements of the absolute intensities of individual CR nuclei are reported in the elemental range fro…
▽ More
During its second Antarctic flight, the CREAM (Cosmic Ray Energetics And Mass) balloon experiment collected data for 28 days, measuring the charge and the energy of cosmic rays (CR) with a redundant system of particle identification and an imaging thin ionization calorimeter. Preliminary direct measurements of the absolute intensities of individual CR nuclei are reported in the elemental range from carbon to iron at very high energy.
△ Less
Submitted 30 March, 2010;
originally announced March 2010.
-
Energy cross-calibration from the first CREAM flight: transition radiation detector versus calorimeter
Authors:
P. Maestro,
H. S. Ahn,
P. S. Allison,
M. G. Bagliesi,
J. J. Beatty,
G. Bigongiari,
P. J. Boyle,
T. J. Brandt,
J. T. Childers,
N. B. Conklin,
S. Coutu,
M. A. Duvernois,
O. Ganel,
J. H. Han,
H. J. Hyun,
J. A. Jeon,
K. C. Kim,
J. K. Lee,
M. H. Lee,
L. Lutz,
P. S. Marrocchesi,
A. Malinine,
S. Minnick,
S. I. Mognet,
S. Nam
, et al. (13 additional authors not shown)
Abstract:
The Cosmic Ray Energetics And Mass (CREAM) balloon experiment had two successful flights in 2004/05 and 2005/06. It was designed to perform energy measurements from a few GeV up to 1000 TeV, taking advantage of different detection techniques. The first instrument, CREAM-1, combined a transition radiation detector with a calorimeter to provide independent energy measurements of cosmicraynuclei. Eac…
▽ More
The Cosmic Ray Energetics And Mass (CREAM) balloon experiment had two successful flights in 2004/05 and 2005/06. It was designed to perform energy measurements from a few GeV up to 1000 TeV, taking advantage of different detection techniques. The first instrument, CREAM-1, combined a transition radiation detector with a calorimeter to provide independent energy measurements of cosmicraynuclei. Each detector was calibrated with particle beams in a limited range of energies. In order to assess the absolute energy scale of the instrument and to investigate the systematic effects of each technique, a cross-calibration was performed by comparing the two independent energy estimates on selected samples of oxygen and carbon nuclei.
△ Less
Submitted 30 March, 2010;
originally announced March 2010.
-
Elemental Spectra from the CREAM-I Flight
Authors:
H. S. Ahn,
P. Allison,
M. G. Bagliesi,
J. J. Beatty,
G. Bigongiari,
P. Boyle,
J. T. Childers,
N. B. Conklin,
S. Coutu,
M. A. Duvernois,
O. Ganel,
J. H. Han,
J. A. Jeon,
K. C. Kim,
J. K. Lee,
M. H. Lee,
L. Lutz,
P. Maestro,
A. Malinine,
P. S. Marrocchesi,
S. Minnick,
S. I. Mognet,
S. Nam,
S. Nutter,
I. H. Park
, et al. (10 additional authors not shown)
Abstract:
The Cosmic Ray Energetics And Mass (CREAM) is a balloon-borne experiment designed to measure the composition and energy spectra of cosmic rays of charge Z = 1 to 26 up to an energy of ~ 10^15 eV. CREAM had two successful flights on long-duration balloons (LDB) launched from Mc- Murdo Station, Antarctica, in December 2004 and December 2005. CREAM-I achieves a substantial measurement redundancy by e…
▽ More
The Cosmic Ray Energetics And Mass (CREAM) is a balloon-borne experiment designed to measure the composition and energy spectra of cosmic rays of charge Z = 1 to 26 up to an energy of ~ 10^15 eV. CREAM had two successful flights on long-duration balloons (LDB) launched from Mc- Murdo Station, Antarctica, in December 2004 and December 2005. CREAM-I achieves a substantial measurement redundancy by employing multiple detector systems, namely a Timing Charge Detector and a Silicon Charge Detector (SCD) for particle identification, and a Transition Radiation Detector and a sampling tungsten/scintillating-fiber ionization calorimeter (CAL) for energy measurement. In this paper, preliminary energy spectra of various elements measured with CAL/SCD during the first 42-day flight are presented.
△ Less
Submitted 30 March, 2010; v1 submitted 25 March, 2010;
originally announced March 2010.
-
Beam test calibration of the balloon-borne imaging calorimeter for the CREAM experiment
Authors:
P. S. Marrocchesi,
H. S. Ahn,
M. G. Bagliesi,
A. Basti,
G. Bigongiari,
A. Castellina,
M. A. Ciocci,
A. Di Virgilio,
T. Lomtatze,
O. Ganel,
K. C. Kim,
M. H. Lee,
F. Ligabue,
L. Lutz,
P. Maestro,
A. Malinine,
M. Meucci,
V. Millucci,
F. Morsani,
E. S. Seo,
R. Sina,
J. Wu,
J. Wu,
Y. S. Yoon,
R. Zei
, et al. (1 additional authors not shown)
Abstract:
CREAM (Cosmic Ray Energetics And Mass) is a multi-flight balloon mission designed to collect direct data on the elemental composition and individual energy spectra of cosmic rays. Two instrument suites have been built to be flown alternately on a yearly base. The tungsten/Sci-Fi imaging calorimeter for the second flight, scheduled for December 2005, was calibrated with electron and proton beams at…
▽ More
CREAM (Cosmic Ray Energetics And Mass) is a multi-flight balloon mission designed to collect direct data on the elemental composition and individual energy spectra of cosmic rays. Two instrument suites have been built to be flown alternately on a yearly base. The tungsten/Sci-Fi imaging calorimeter for the second flight, scheduled for December 2005, was calibrated with electron and proton beams at CERN. A calibration procedure based on the study of the longitudinal shower profile is described and preliminary results of the beam test are presented.
△ Less
Submitted 15 June, 2018; v1 submitted 24 March, 2010;
originally announced March 2010.
-
Performance of the CREAM calorimeter in accelerator beam test
Authors:
Y. S. Yoon,
H. S. Ahn,
M. G. Bagliesi,
G. Bigongiari,
O. Ganel,
J. H. Han,
H. J. Hyun,
J. A. Jeon,
T. G. Kang,
H. J. Kim,
K. C. Kim,
J. K. Lee,
M. H. Lee,
L. Lutz,
P. Maestro,
A. Malinine,
P. S. Marrocchesi,
S. W. Nam,
H. Park,
I. H. Park,
N. H. Park,
E. S. Seo,
R. Sina,
J. Wu,
J. Yang
, et al. (2 additional authors not shown)
Abstract:
The CREAM calorimeter, designed to measure the spectra of cosmic-ray nuclei from under 1 TeV to 1000 TeV, is a 20 radiation length (X0) deep sampling calorimeter. The calorimeter is comprised of 20 layers of tungsten interleaved with 20 layers of scintillating fiber ribbons, and is preceded by a pair of graphite interaction targets providing about 0.42 proton interaction lengths (λint). The calori…
▽ More
The CREAM calorimeter, designed to measure the spectra of cosmic-ray nuclei from under 1 TeV to 1000 TeV, is a 20 radiation length (X0) deep sampling calorimeter. The calorimeter is comprised of 20 layers of tungsten interleaved with 20 layers of scintillating fiber ribbons, and is preceded by a pair of graphite interaction targets providing about 0.42 proton interaction lengths (λint). The calorimeter was placed in one of CERN's SPS accelerator beams for calibration and testing. Beams of 150 GeV electrons were used for calibration, and a variety of electron, proton, and nuclear fragment beams were used to test the simulation model of the detector. In this paper we discuss the performance of the calorimeter in the electron beam and compare electron beam data with simulation results.
△ Less
Submitted 24 March, 2010;
originally announced March 2010.
-
Calibration of the CREAM-I calorimeter
Authors:
Y. S. Yoon,
H. S. Ahn,
M. G. Bagliesi,
G. Bigongiari,
O. Ganel,
J. H. Han,
J. A. Jeon,
K. C. Kim,
M. H. Lee,
L. Lutz,
P. Maestro,
A. Malinin,
P. S. Marrocchesi,
S. Nam,
I. H. Park,
N. H. Park,
E. S. Seo,
R. Sina,
J. Wu,
J. Yang,
R. Zei,
S. Y. Zinn
Abstract:
The Cosmic Ray Energetics And Mass (CREAM) calorimeter is designed to measure the spectra of cosmic-ray particles over the energy range from ~10^11 eV to ~10^15 eV. Its first flight as part of the CREAM-I balloon-borne payload in Antarctica during the 2004/05 season resulted in a recordbreaking 42 days of exposure. Calorimeter calibration using various beam test data will be discussed in an attemp…
▽ More
The Cosmic Ray Energetics And Mass (CREAM) calorimeter is designed to measure the spectra of cosmic-ray particles over the energy range from ~10^11 eV to ~10^15 eV. Its first flight as part of the CREAM-I balloon-borne payload in Antarctica during the 2004/05 season resulted in a recordbreaking 42 days of exposure. Calorimeter calibration using various beam test data will be discussed in an attempt to assess the uncertainties of the energy measurements.
△ Less
Submitted 24 March, 2010;
originally announced March 2010.
-
Energy spectra of cosmic-ray nuclei at high energies
Authors:
H. S. Ahn,
P. Allison,
M. G. Bagliesi,
L. Barbier,
J. J. Beatty,
G. Bigongiari,
T. J. Brandt,
J. T. Childers,
N. B. Conklin,
S. Coutu,
M. A. DuVernois,
O. Ganel,
J. H. Han,
J. A. Jeon,
K. C. Kim,
M. H. Lee,
P. Maestro,
A. Malinine,
P. S. Marrocchesi,
S. Minnick,
S. I. Mognet,
S. W. Nam,
S. Nutter,
I. H. Park,
N. H. Park
, et al. (8 additional authors not shown)
Abstract:
We present new measurements of the energy spectra of cosmic-ray (CR) nuclei from the second flight of the balloon-borne experiment Cosmic Ray Energetics And Mass (CREAM). The instrument included different particle detectors to provide redundant charge identification and measure the energy of CRs up to several hundred TeV. The measured individual energy spectra of C, O, Ne, Mg, Si, and Fe are pre…
▽ More
We present new measurements of the energy spectra of cosmic-ray (CR) nuclei from the second flight of the balloon-borne experiment Cosmic Ray Energetics And Mass (CREAM). The instrument included different particle detectors to provide redundant charge identification and measure the energy of CRs up to several hundred TeV. The measured individual energy spectra of C, O, Ne, Mg, Si, and Fe are presented up to $\sim 10^{14}$ eV. The spectral shape looks nearly the same for these primary elements and it can be fitted to an $E^{-2.66 \pm 0.04}$ power law in energy. Moreover, a new measurement of the absolute intensity of nitrogen in the 100-800 GeV/$n$ energy range with smaller errors than previous observations, clearly indicates a hardening of the spectrum at high energy. The relative abundance of N/O at the top of the atmosphere is measured to be $0.080 \pm 0.025 $(stat.)$ \pm 0.025 $(sys.) at $\sim $800 GeV/$n$, in good agreement with a recent result from the first CREAM flight.
△ Less
Submitted 10 November, 2009;
originally announced November 2009.
-
Measurements of cosmic-ray secondary nuclei at high energies with the first flight of the CREAM balloon-borne experiment
Authors:
H. S. Ahn,
P. S. Allison,
M. G. Bagliesi,
J. J. Beatty,
G. Bigongiari,
P. J. Boyle,
T. J. Brandt,
J. T. Childers,
N. B. Conklin,
S. Coutu,
M. A. Duvernois,
O. Ganel,
J. H. Han,
H. J. Hyun,
J. A. Jeon,
K. C. Kim,
J. K. Lee,
M. H. Lee,
L. Lutz,
P. Maestro,
A. Malinin,
P. S. Marrocchesi,
S. A. Minnick,
S. I. Mognet,
S. Nam
, et al. (12 additional authors not shown)
Abstract:
We present new measurements of heavy cosmic-ray nuclei at high energies per- formed during the first flight of the balloon-borne cosmic-ray experiment CREAM (Cosmic-Ray Energetics And Mass). This instrument uses multiple charge detectors and a transition radiation detector to provide the first high accuracy measurements of the relative abundances of elements from boron to oxygen up to energies a…
▽ More
We present new measurements of heavy cosmic-ray nuclei at high energies per- formed during the first flight of the balloon-borne cosmic-ray experiment CREAM (Cosmic-Ray Energetics And Mass). This instrument uses multiple charge detectors and a transition radiation detector to provide the first high accuracy measurements of the relative abundances of elements from boron to oxygen up to energies around 1 TeV/n. The data agree with previous measurements at lower energies and show a relatively steep decline (~E$^-0.6$ to E$^-0.5$) at high energies. They further show the source abundance of nitrogen relative to oxygen is ~10% in the TeV/n region.
△ Less
Submitted 12 August, 2008;
originally announced August 2008.