Sudden polarization angle jumps of the repeating fast radio burst FRB 20201124A
Authors:
J. R. Niu,
W. Y. Wang,
J. C. Jiang,
Y. Qu,
D. J. Zhou,
W. W. Zhu,
K. J. Lee,
J. L. Han,
B. Zhang,
D. Li,
S. Cao,
Z. Y. Fang,
Y. Feng,
Q. Y. Fu,
P. Jiang,
W. C. Jing,
J. Li,
Y. Li,
R. Luo,
L. Q. Meng,
C. C. Miao,
X. L. Miao,
C. H. Niu,
Y. C. Pan,
B. J. Wang
, et al. (19 additional authors not shown)
Abstract:
We report the first detection of polarization angle (PA) orthogonal jumps, a phenomenon previously only observed from radio pulsars, from a fast radio burst (FRB) source FRB 20201124A. We find three cases of orthogonal jumps in over two thousand bursts, all resembling those observed in pulsar single pulses. We propose that the jumps are due to the superposition of two orthogonal emission modes tha…
▽ More
We report the first detection of polarization angle (PA) orthogonal jumps, a phenomenon previously only observed from radio pulsars, from a fast radio burst (FRB) source FRB 20201124A. We find three cases of orthogonal jumps in over two thousand bursts, all resembling those observed in pulsar single pulses. We propose that the jumps are due to the superposition of two orthogonal emission modes that could only be produced in a highly magnetized plasma, and they are caused by the line of sight sweeping across a rotating magnetosphere. The shortest jump timescale is of the order of one-millisecond, which hints that the emission modes come from regions smaller than the light cylinder of most pulsars or magnetars. This discovery provides convincing evidence that FRB emission originates from the complex magnetosphere of a magnetar, suggesting an FRB emission mechanism that is analogous to radio pulsars despite a huge luminosity difference between two types of objects.
△ Less
Submitted 14 August, 2024; v1 submitted 15 July, 2024;
originally announced July 2024.
-
The Design and Performance of Charged Particle Detector onboard the GECAM Mission
Authors:
Y. B. Xu,
X. L. Sun,
S. Yang,
X. Q. Li,
W. X. Peng,
K. Gong,
X. H. Liang,
Y. Q. Liu,
D. Y. Guo,
H. Wang,
C. Y. Li,
Z. H. An,
J. J. He,
X. J. Liu,
S. L. Xiong,
X. Y. Wen,
Fan Zhang,
D. L. Zhang,
X. Y. Zhao,
C. Y. Zhang,
C. Cai,
Z. Chang,
G. Chen,
C. Chen,
Y. Y. Du
, et al. (25 additional authors not shown)
Abstract:
The Gravitational Wave highly energetic Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to detecting gravitational wave gamma-ray bursts. It is capable of all-sky monitoring over and discovering gamma-ray bursts and new radiation phenomena. GECAM consists of two microsatellites, each equipped with 8 charged particle detectors (CPDs) and 25 gamma-ray detectors (GRDs). The CPD is us…
▽ More
The Gravitational Wave highly energetic Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to detecting gravitational wave gamma-ray bursts. It is capable of all-sky monitoring over and discovering gamma-ray bursts and new radiation phenomena. GECAM consists of two microsatellites, each equipped with 8 charged particle detectors (CPDs) and 25 gamma-ray detectors (GRDs). The CPD is used to measure charged particles in the space environment, monitor energy and flow intensity changes, and identify between gamma-ray bursts and space charged particle events in conjunction with GRD. CPD uses plastic scintillator as the sensitive material for detection, silicon photomultiplier (SiPM) array as the optically readable device, and the inlaid Am-241 radioactive source as the onboard calibration means. In this paper, we will present the working principle, physical design, functional implementation and preliminary performance test results of the CPD.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
Ground-based calibration and characterization of GRD of GECAM: 8-160 keV
Authors:
J. J. He,
Z. H. An,
W. X. Peng,
X. Q. Li,
S. L. Xiong,
D. L. Zhang,
R. Qiao,
D. Y. Guo,
C. Cai,
Z. Chang,
C. Chen,
G. Chen,
Y. Y. Du,
M. Gao,
R. Gao,
K. Gong,
D. J. Hou,
C. Y. Li,
G. Li,
L. Li,
M. S. Li,
X. B. Li,
X. F. Li,
Y. G. Li,
X. H. Liang
, et al. (36 additional authors not shown)
Abstract:
As the main detector of the GECAM satellite, the calibration of the energy response and detection efficiency of the GRD detector is the main content of the ground-based calibration. The calibration goal requires the calibrated energy points to sample the full energy range (8 keV-2 MeV) as much as possible. The low energy band (8-160 keV) is calibrated with the X-ray beam, while the high energy ban…
▽ More
As the main detector of the GECAM satellite, the calibration of the energy response and detection efficiency of the GRD detector is the main content of the ground-based calibration. The calibration goal requires the calibrated energy points to sample the full energy range (8 keV-2 MeV) as much as possible. The low energy band (8-160 keV) is calibrated with the X-ray beam, while the high energy band (>160 keV) with radioactive sources. This article mainly focuses on the calibration of the energy response and detection efficiency in the 8-160 keV with a refined measurement around the absorption edges of the lanthanum bromide crystal. The GRD performances for different crystal types, data acquisition modes, working modes, and incident positions are also analyzed in detail. We show that the calibration campaign is comprehensive, and the calibration results are generally consistent with simulations as expected.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
The SiPM Array Data Acquisition Algorithm Applied to the GECAM Satellite Payload
Authors:
Y. Q. Liu,
K. Gong,
X. Q. Li,
X. Y. Wen,
Z. H. An,
C. Cai,
Z. Chang,
G. Chen,
C. Chen,
Y. Y. Du,
M. Gao,
R. Gao,
D. Y. Guo,
J. J. He,
D. J. Hou,
Y. G. Li,
C. Y. Li,
G. Li,
L. Li,
X. F. Li,
M. S. Li,
X. H. Liang,
X. J. Liu,
F. J. Lu,
H. Lu
, et al. (25 additional authors not shown)
Abstract:
The Gravitational Wave Burst High-energy Electromagnetic Counterpart All-sky Monitor (GECAM), consists of 2 small satellites that each contain 25 LaBr3 (lanthanum bromide doped with cerium chloride) detectors and 8 plastic scintillator detectors. The detector signals are read out using a silicon photomultiplier (SiPM) array. In this study, an acquisition algorithm for in-orbit real-time SiPM array…
▽ More
The Gravitational Wave Burst High-energy Electromagnetic Counterpart All-sky Monitor (GECAM), consists of 2 small satellites that each contain 25 LaBr3 (lanthanum bromide doped with cerium chloride) detectors and 8 plastic scintillator detectors. The detector signals are read out using a silicon photomultiplier (SiPM) array. In this study, an acquisition algorithm for in-orbit real-time SiPM array data is designed and implemented, and the output event packet is defined. Finally, the algorithm's efficacy for event acquisition is verified.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
The design and performance of GRD onboard the GECAM satellite
Authors:
Z. H. An,
X. L. Sun,
D. L. Zhang,
S. Yang,
X. Q. Li,
X. Y. Wen,
K. Gong,
X. H. Liang,
X. J. Liu,
Y. Q. Liu,
Y. G. Li,
S. L. Xiong,
Y. B. Xu,
Fan Zhang,
X. Y. Zhao,
C. Cai,
Z. Chang,
G. Chen,
C. Chen,
Y. Y. Du,
P. Y. Feng,
M. Gao,
R. Gao,
D. Y. Guo,
J. J. He
, et al. (26 additional authors not shown)
Abstract:
Background: Each GECAM satellite payload contains 25 gamma-ray detectors (GRDs), which can detect gamma-rays and particles and can roughly localize the Gamma-Ray Bursts (GRBs). GRD was designed using lanthanum bromide (LaBr3) crystal as the sensitive material with the rear end coupled with silicon photomultiplier (SiPM) array for readout. Purpose: In aerospace engineering design of GRD, there are…
▽ More
Background: Each GECAM satellite payload contains 25 gamma-ray detectors (GRDs), which can detect gamma-rays and particles and can roughly localize the Gamma-Ray Bursts (GRBs). GRD was designed using lanthanum bromide (LaBr3) crystal as the sensitive material with the rear end coupled with silicon photomultiplier (SiPM) array for readout. Purpose: In aerospace engineering design of GRD, there are many key points to be studied. In this paper, we present the specific design scheme of GRD, the assembly and the performance test results of detectors. Methods: Based on Monte Carlo simulation and experimental test results, the specific schematic design and assembling process ofGRDwere optimized. After being fully assembled, theGRDswere conducted performance tests by using radioactive source and also conducted random vibration tests. Result and conclusion: The test results show that all satellite-borne GRDs have energy resolution <16% at 59.5 keV, meeting requirements of satellite in scientific performance. The random vibration test shows that GRD can maintain in a stable performance, which meets the requirement of spatial application.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
Dedicated SiPM array for GRD of GECAM
Authors:
D. L. Zhang,
X. L. Sun,
Z. H. An,
X. Q. Li,
X. Y. Wen,
K. Gong,
C. Cai,
Z. Chang,
G. Chen,
C. Chen,
Y. Y. Du,
M. Gao,
R. Gao,
D. Y. Guo,
J. J. He,
D. J. Hou,
Y. G. Li,
C. Y. Li,
G. Li,
L. Li,
X. F. Li,
M. S. Li,
X. H. Liang,
X. J. Liu,
Y. Q. Liu
, et al. (23 additional authors not shown)
Abstract:
The discovery of gravitational waves and gamma-ray bursts heralds the era of multi-messenger astronomy. With the adoption of two small satellites to achieve the all-sky monitoring of gamma-ray bursts, the gravitational wave high-energy electromagnetic counterpart all-sky monitor (GECAM) possesses a quasi-real-time early warning ability and plays an important role in positioning the sources of grav…
▽ More
The discovery of gravitational waves and gamma-ray bursts heralds the era of multi-messenger astronomy. With the adoption of two small satellites to achieve the all-sky monitoring of gamma-ray bursts, the gravitational wave high-energy electromagnetic counterpart all-sky monitor (GECAM) possesses a quasi-real-time early warning ability and plays an important role in positioning the sources of gravitational waves and in subsequent observations.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
Earth wind as a possible source of lunar surface hydration
Authors:
H. Z. Wang,
J. Zhang,
Q. Q. Shi,
Y. Saito,
A. W. Degeling,
I. J. Rae,
J. Liu,
R. L. Guo,
Z. H. Yao,
A. M. Tian,
X. H. Fu,
Q. G. Zong,
J. Z. Liu,
Z. C. Ling,
W. J. Sun,
S. C. Bai,
J. Chen,
S. T. Yao,
H. Zhang,
Y. Wei,
W. L. Liu,
L. D. Xia,
Y. Chen,
Y. Y. Feng,
S. Y. Fu
, et al. (1 additional authors not shown)
Abstract:
Understanding the sources of lunar water is crucial for studying the history of lunar evolution, and also the solar wind interaction with the Moon and other airless bodies. Recent observations revealed lunar hydration is very likely a surficial dynamic process driven by solar wind. Solar wind is shielded over a period of 3-5 days as the Moon passes through the Earth's magnetosphere, during which a…
▽ More
Understanding the sources of lunar water is crucial for studying the history of lunar evolution, and also the solar wind interaction with the Moon and other airless bodies. Recent observations revealed lunar hydration is very likely a surficial dynamic process driven by solar wind. Solar wind is shielded over a period of 3-5 days as the Moon passes through the Earth's magnetosphere, during which a significant loss of hydration is expected from previous works.Here we study lunar hydration inside the magnetosphere using orbital spectral data, which unexpectedly found that the polar surficial OH/H2O abundance remains at the same level when in the solar wind and in the magnetosphere. We suggest that particles from the magnetosphere (Earth wind, naturally different from solar wind) contribute to lunar hydration. From lunar orbital plasma observations, we find the existence of optimal energy ranges, other than 1 keV as previously thought, for surface hydration formation. These optimal energy ranges deduced from space observations may provide strong implications for laboratory experiments simulating lunar hydration processes.
△ Less
Submitted 10 March, 2019;
originally announced March 2019.