A Silicon Microstrip Detector for Power-Limited and Large Sensitive Area Applications
Authors:
Dexing Miao,
Zijun Xu,
Zhiyu Xiang,
Pingcheng Liu,
Giovanni Ambrosi,
Mattia Barbanera,
Mengke Cai,
Xudong Cai,
Hsin-Yi Chou,
Matteo Duranti,
Valerio Formato,
Maria Ionica,
Yaozu Jiang,
Liangchenglong Jin,
Vladimir Koutsenko,
Qinze Li,
Cong Liu,
Xingjian Lv,
Alberto Oliva,
Wenxi Peng,
Rui Qiao,
Gianluigi Silvestre,
Zibing Wu,
Xuhao Yuan,
Hongyu Zhang
, et al. (2 additional authors not shown)
Abstract:
A silicon microstrip detector (SSD) has been developed to have state of the art spatial resolution and a large sensitive area under stringent power constraints. The design incorporates three floating strips with their bias resistors inserted between two aluminum readout strips. Beam test measurements with the single sensor confirmed that this configuration achieves a total detection efficiency of…
▽ More
A silicon microstrip detector (SSD) has been developed to have state of the art spatial resolution and a large sensitive area under stringent power constraints. The design incorporates three floating strips with their bias resistors inserted between two aluminum readout strips. Beam test measurements with the single sensor confirmed that this configuration achieves a total detection efficiency of $99.8 \, \%$ and spatial resolution $7.6 \, \mathrm{μm}$ for MIPs. A double-$η$ algorithm was developed to optimize hit position reconstruction for this SSD. The design can be adapted for large area silicon detectors.
△ Less
Submitted 28 May, 2025;
originally announced May 2025.
Tracker-In-Calorimeter (TIC): a calorimetric approach to tracking gamma rays in space experiments
Authors:
O. Adriani,
G. Ambrosi,
P. Azzarello,
A. Basti,
E. Berti,
B. Bertucci,
G. Bigongiari,
L. Bonechi,
M. Bongi,
S. Bottai,
M. Brianzi,
P. Brogi,
G. Castellini,
E. Catanzani,
C. Checchia,
R. D'Alessandro,
S. Detti,
M. Duranti,
N. Finetti,
V. Formato,
M. Ionica,
P. Maestro,
F. Maletta,
P. S. Marrocchesi,
N. Mori
, et al. (11 additional authors not shown)
Abstract:
A multi-messenger, space-based cosmic ray detector for gamma rays and charged particles poses several design challenges due to the different instrumental requirements for the two kind of particles. Gamma-ray detection requires layers of high Z materials for photon conversion and a tracking device with a long lever arm to achieve the necessary angular resolution to separate point sources; on the co…
▽ More
A multi-messenger, space-based cosmic ray detector for gamma rays and charged particles poses several design challenges due to the different instrumental requirements for the two kind of particles. Gamma-ray detection requires layers of high Z materials for photon conversion and a tracking device with a long lever arm to achieve the necessary angular resolution to separate point sources; on the contrary, charge measurements for atomic nuclei requires a thin detector in order to avoid unwanted fragmentation, and a shallow instrument so to maximize the geometric factor. In this paper, a novel tracking approach for gamma rays which tries to reconcile these two conflicting requirements is presented. The proposal is based on the Tracker-In-Calorimeter (TIC) design that relies on a highly-segmented calorimeter to track the incident gamma ray by sampling the lateral development of the electromagnetic shower at different depths. The effectiveness of this approach has been studied with Monte Carlo simulations and has been validated with test beam data of a detector prototype.
△ Less
Submitted 22 October, 2020; v1 submitted 4 August, 2020;
originally announced August 2020.