The composition of cosmic rays according to the data on EAS cores
Authors:
S. B. Shaulov,
V. A. Ryabov,
S. E. Pyatovsky,
A. L. Shepetov,
V. V. Zhukov
Abstract:
The main purpose of this work is to find the causes of the break of the cosmic ray spectrum at an energy of 3 PeV, which is called the knee. The solution of the problem is associated with the determination of the nuclear composition of cosmic rays in the knee area. The conclusions of this work are based on the analysis of the characteristics of the EAS cores obtained using X-ray emulsion chambers.…
▽ More
The main purpose of this work is to find the causes of the break of the cosmic ray spectrum at an energy of 3 PeV, which is called the knee. The solution of the problem is associated with the determination of the nuclear composition of cosmic rays in the knee area. The conclusions of this work are based on the analysis of the characteristics of the EAS cores obtained using X-ray emulsion chambers. According to these data, a number of anomalous effects are observed in the knee region, such as scaling violation in the spectra of secondary hadrons, an excess of muons in EAS with gamma families and others. At the same energies equivalent to 1-100 PeV the laboratory system colliders show scaling behavior. So analysis of the data on the EAS cores suggests that the knee in their spectrum is formed by a component of cosmic rays of a non-nuclear nature, possibly consisting of stable (quasi-stable) particles of hypothetical strange quark matter, which named strangelets. This is the only model of the knee compatible with the magnetic rigidity of the nuclear spectra break R=100 TV. In fact, stranglets are stable heavy quasi-nuclei with a positive electric charge of Z=30-1000, so the mechanism of their acceleration coincides with the nuclear one. The break of the cosmic ray spectrum can be associated with a significantly larger mass of strangelets compared to nuclei.
△ Less
Submitted 26 September, 2022; v1 submitted 24 June, 2022;
originally announced June 2022.
New complex EAS installation of the Tien Shan Mountain Cosmic Ray Station
Authors:
A. P. Chubenko,
A. L. Shepetov,
V. P. Antonova,
R. U. Beisembayev,
A. S. Borisov,
O. D. Dalkarov,
O. N. Kryakunova,
K. M. Mukashev,
R. A. Mukhamedshin,
R. A. Nam,
N. F. Nikolaevsky,
V. P. Pavlyuchenko,
V. V. Piscal,
V. S. Puchkov,
V. A. Ryabov,
T. Kh. Sadykov,
N. O. Saduev,
N. M. Salikhov,
S. B. Shaulov,
A. V. Stepanov,
N. G. Vildanov,
L. I. Vildanova,
M. I. Vildanova,
N. N. Zastrozhnova,
V. V. Zhukov
Abstract:
We present a description of the new complex installation for the study of extensive air showers which was created at the Tien Shan mountain cosmic ray station, as well as the results of the test measurements made there in 2014-2016. At present, the system for registration of electromagnetic shower component consists of $\sim$100 detector points built on the basis of plastic scintillator plates wit…
▽ More
We present a description of the new complex installation for the study of extensive air showers which was created at the Tien Shan mountain cosmic ray station, as well as the results of the test measurements made there in 2014-2016. At present, the system for registration of electromagnetic shower component consists of $\sim$100 detector points built on the basis of plastic scintillator plates with the sensitive area of 0.25m$^2$ and 1m$^2$, spread equidistantly over $\sim$10$^4$m$^2$ space. The dynamic range of scintillation amplitude measurements is currently about $(3-7)\cdot 10^4$, and there is a prospect of it being extended up to $\sim$10$^6$. The direction of shower arrival is defined by signal delays from a number of the scintillators placed cross-wise at the periphery of the detector system. For the investigation of nuclear active shower components there was created a multi-tier 55m$^2$ ionization-neutron calorimeter with a sum absorber thickness of $\sim$1000g/cm$^2$, typical spatial resolution of the order of 10cm, and dynamic range of ionization measurement channel about $\sim$10$^5$. Also, the use of saturation-free neutron detectors is anticipated for registration of the high- and low-energy hadron components in the region of shower core. A complex of underground detectors is designed for the study of muonic and penetrative nuclear-active components of the shower.
The full stack of data acquisition, detector calibration, and shower parameters restoration procedures are now completed, and the newly obtained shower size spectrum and lateral distribution of shower particles occur in agreement with conventional data. Future studies in the field of $10^{14}-10^{17}$eV cosmic ray physics to be held at the new shower installation are discussed.
△ Less
Submitted 31 December, 2019;
originally announced December 2019.
Search for Sources of Primary Cosmic Rays at Energies Above 0.1 Pev at Tien Shan
Authors:
G. Benko,
G. Erdos,
S. I. Nikolsky,
N. M. Nesterova,
V. A. Romakhin,
A. P. Chubenko,
A. L. Shepetov,
A. Somogyi,
A. Varga
Abstract:
Analysis of the experimental data of joint Russian - Hungarian research was carried out at Tien Shan station on the search of sources of primary cosmic rays (PCR) at energies 0.1-1.0 PeV. Maps of extensive air shower arrival directions were presented where the standard deviation of mean event numbers in equatorial co-ordinates exceeded a definite value. The excess of EAS number was observed from…
▽ More
Analysis of the experimental data of joint Russian - Hungarian research was carried out at Tien Shan station on the search of sources of primary cosmic rays (PCR) at energies 0.1-1.0 PeV. Maps of extensive air shower arrival directions were presented where the standard deviation of mean event numbers in equatorial co-ordinates exceeded a definite value. The excess of EAS number was observed from an Galaxy object - the SN remnant and some other directions. The young pulsar PSR 0656+14 located near the centre of this object.
△ Less
Submitted 25 February, 2005; v1 submitted 3 February, 2005;
originally announced February 2005.