Measurement of the low-energy quenching factor in germanium using an $^{88}$Y/Be photoneutron source
Authors:
B. J. Scholz,
A. E. Chavarria,
J. I. Collar,
P. Privitera,
A. E. Robinson
Abstract:
We employ an $^{88}$Y/Be photoneutron source to derive the quenching factor for neutron-induced nuclear recoils in germanium, probing recoil energies from a few hundred eV$_{nr}$ to 8.5keV$_{nr}$. A comprehensive Monte Carlo simulation of our setup is compared to experimental data employing a Lindhard model with a free electronic energy loss $k$ and an adiabatic correction for sub-keV$_{nr}$ nucle…
▽ More
We employ an $^{88}$Y/Be photoneutron source to derive the quenching factor for neutron-induced nuclear recoils in germanium, probing recoil energies from a few hundred eV$_{nr}$ to 8.5keV$_{nr}$. A comprehensive Monte Carlo simulation of our setup is compared to experimental data employing a Lindhard model with a free electronic energy loss $k$ and an adiabatic correction for sub-keV$_{nr}$ nuclear recoils. The best fit $k=0.179\pm 0.001$ obtained using a Monte Carlo Markov Chain (MCMC) ensemble sampler is in good agreement with previous measurements, confirming the adequacy of the Lindhard model to describe the stopping of few-keV ions in germanium crystals at a temperature of $\sim$77 K. This value of $k$ corresponds to a quenching factor of 13.7 % to 25.3 % for nuclear recoil energies between 0.3 keV$_{nr}$ and 8.5 keV$_{nr}$, respectively.
△ Less
Submitted 11 August, 2016;
originally announced August 2016.
-
Measurement of the ionization produced by sub-keV silicon nuclear recoils in a CCD dark matter detector
Authors:
A. E. Chavarria,
J. I. Collar,
J. R. Peña,
P. Privitera,
A. E. Robinson,
B. Scholz,
C. Sengul,
J. Zhou,
J. Estrada,
F. Izraelevitch,
J. Tiffenberg,
J. R. T. de Mello Neto,
D. Torres Machado
Abstract:
We report a measurement of the ionization efficiency of silicon nuclei recoiling with sub-keV kinetic energy in the bulk silicon of a charge-coupled device (CCD). Nuclear recoils are produced by low-energy neutrons ($<$24 keV) from a $^{124}$Sb-$^{9}$Be photoneutron source, and their ionization signal is measured down to 60 eV electron equivalent. This energy range, previously unexplored, is relev…
▽ More
We report a measurement of the ionization efficiency of silicon nuclei recoiling with sub-keV kinetic energy in the bulk silicon of a charge-coupled device (CCD). Nuclear recoils are produced by low-energy neutrons ($<$24 keV) from a $^{124}$Sb-$^{9}$Be photoneutron source, and their ionization signal is measured down to 60 eV electron equivalent. This energy range, previously unexplored, is relevant for the detection of low-mass dark matter particles. The measured efficiency is found to deviate from the extrapolation to low energies of the Lindhard model. This measurement also demonstrates the sensitivity to nuclear recoils of CCDs employed by DAMIC, a dark matter direct detection experiment located in the SNOLAB underground laboratory.
△ Less
Submitted 9 November, 2016; v1 submitted 2 August, 2016;
originally announced August 2016.
-
Coherent neutrino-nucleus scattering detection with a CsI[Na] scintillator at the SNS spallation source
Authors:
J. I. Collar,
N. E. Fields,
E. Fuller,
M. Hai,
T. W. Hossbach,
J. L. Orrell,
G. Perumpilly,
B. Scholz
Abstract:
We study the possibility of using CsI[Na] scintillators as an advantageous target for the detection of coherent elastic neutrino-nucleus scattering (CENNS), using the neutrino emissions from the SNS spallation source at Oak Ridge National Laboratory. The response of this material to low-energy nuclear recoils like those expected from this process is characterized. Backgrounds are studied using a 2…
▽ More
We study the possibility of using CsI[Na] scintillators as an advantageous target for the detection of coherent elastic neutrino-nucleus scattering (CENNS), using the neutrino emissions from the SNS spallation source at Oak Ridge National Laboratory. The response of this material to low-energy nuclear recoils like those expected from this process is characterized. Backgrounds are studied using a 2 kg low-background prototype crystal in a dedicated radiation shield. The conclusion is that a planned 14 kg detector should measure approximately 550 CENNS events per year above a demonstrated $\sim7$ keVnr low-energy threshold, with a signal-to-background ratio sufficient for a first measurement of the CENNS cross-section. The cross-section for the $^{208}$Pb($ν_{e},e^{-}$)$^{208}$Bi reaction, of interest for future supernova neutrino detection, can be simultaneously obtained.
△ Less
Submitted 20 August, 2014; v1 submitted 28 July, 2014;
originally announced July 2014.