Visible Emission Line Coronagraph (VELC) onboard ADITYA-L1
Authors:
Jagdev Singh,
R. Ramesh,
B. Raghavendra Prasad,
V. Muthu Priyal,
K. Sasikumar Raja,
S. N. Venkata,
P. U. Kamath,
V. Natarajan,
S. Pawankumar,
V. U. Sanal Krishnan,
P. Savarimuthu,
Shalabh Mishra,
Varun Kumar,
Chavali Sumana,
S. Bhavana Hegde,
D. Utkarsha,
Amit Kumar,
S. Nagabhushana,
S. Kathiravan,
P. Vemareddy,
C. Kathiravan,
K. Nagaraju,
Belur Ravindra,
Wageesh Mishra
Abstract:
Aditya-L1, India's first dedicated mission to study the Sun and its atmosphere from the Sun-Earth Lagrangian L1 location was successfully launched on 2023 September 2. It carries seven payloads. The Visible Emission Line Coronagraph (VELC) is a major payload on Aditya-L1. VELC is designed to carry out imaging and spectroscopic observations (the latter in three emission lines of the corona), simult…
▽ More
Aditya-L1, India's first dedicated mission to study the Sun and its atmosphere from the Sun-Earth Lagrangian L1 location was successfully launched on 2023 September 2. It carries seven payloads. The Visible Emission Line Coronagraph (VELC) is a major payload on Aditya-L1. VELC is designed to carry out imaging and spectroscopic observations (the latter in three emission lines of the corona), simultaneously. Images of the solar corona in the continuum at 5000 A, with a field of view (FoV) from 1.05 Ro to 3 Ro can be obtained at variable intervals depending on the data volume that can be downloaded. Spectroscopic observations of the solar corona in three emission lines, namely 5303 A Fexiv, 7892 A Fexi, and 10747 A Fexiii are possible simultaneously, with different exposure times and cadence. Four slits, each of width 50 um, separated by 3.75 mm help to simultaneously obtain spectra at four positions in the solar corona at all the aforementioned lines. A Linear Scan Mechanism (LSM) makes it possible to scan the solar corona up to +/-1.5 Ro. The instrument has the facility to carry out spectropolarimetric observations at 10747 A also in the FoV range 1.05 - 1.5 Ro. Various components of the instrument were tested interferometrically on the optical bench before installation. The individual components were aligned and performance of the payload was checked in the laboratory using a laser source and tungsten lamp. Wavelength calibration of the instrument was verified using Sun as a light source. All the detectors were calibrated for different parameters such as dark current and its variation with exposure time. Here, we discuss the various features of the VELC, alignment, calibration, performance, possible observations, initial data analysis and results of initial tests conducted in-orbit.
△ Less
Submitted 22 May, 2025; v1 submitted 27 March, 2025;
originally announced March 2025.
New Results on the Onset of a Coronal Mass Ejection from 5303 Å Emission Line Observations with VELC/ADITYA-L1
Authors:
R. Ramesh,
V. Muthu Priyal,
Jagdev Singh,
K. Sasikumar Raja,
P. Savarimuthu,
Priya Gavshinde
Abstract:
We report on the onset of a coronal mass ejection (CME) using spectroscopic observations in 5303 Å coronal emission line with the Visible Emission Line Coronagraph (VELC) onboard ADITYA-L1, the recently launched first Indian space solar mission. The CME was observed on 16 July 2024 in association with a X1.9 class soft X-ray flare from heliographic location S05W85. The VELC observations were near…
▽ More
We report on the onset of a coronal mass ejection (CME) using spectroscopic observations in 5303 Å coronal emission line with the Visible Emission Line Coronagraph (VELC) onboard ADITYA-L1, the recently launched first Indian space solar mission. The CME was observed on 16 July 2024 in association with a X1.9 class soft X-ray flare from heliographic location S05W85. The VELC observations were near the west limb of Sun during the CME. The results obtained helped to constrain the onset time of the CME. In addition, they indicate ${\approx}$50% decrease in the coronal intensity near the source region of the CME due to mass depletion, ${\approx}$15% enhancement in the emission line width, and redshifted Doppler velocity of about ${\approx}10$ km/s. The non-thermal velocity associated with the line broadening is ${\approx}24.87$ km/s.
△ Less
Submitted 14 November, 2024;
originally announced November 2024.