-
Directional detection of keV proton and carbon recoils with MIMAC
Authors:
C. Beaufort,
O. Guillaudin,
D. Santos,
N. Sauzet,
E. Mobio,
R. Babut,
C. Tao
Abstract:
Directional detection is the dedicated strategy to demonstrate that DM-like signals measured by direct detectors are indeed produced by DM particles from the galactic halo. The experimental challenge of measuring the direction of DM-induced nuclear recoils with (sub-)millimeter tracks has limited, so far, the maximal directional reach to DM masses around $100~\rm{GeV}$. In this paper, we expose th…
▽ More
Directional detection is the dedicated strategy to demonstrate that DM-like signals measured by direct detectors are indeed produced by DM particles from the galactic halo. The experimental challenge of measuring the direction of DM-induced nuclear recoils with (sub-)millimeter tracks has limited, so far, the maximal directional reach to DM masses around $100~\rm{GeV}$. In this paper, we expose the MIMAC detector to three different neutron fields and we develop a method to reconstruct the direction of the neutron-induced nuclear recoils. We measure an angular resolution better than $16^\circ$ for proton recoils down to a kinetic energy of $4~\rm{keV}$ and for carbon recoils down to a kinetic energy of $5.5~\rm{keV}$. For the first time, a detector achieves the directional measurement of proton and carbon recoils with kinetic energies in the keV range without any restriction on the direction of the incoming particle. This work demonstrates that directional detection is around the corner for probing DM with masses down to $\mathcal{O}(1~\rm{GeV})$.
△ Less
Submitted 27 March, 2024; v1 submitted 20 December, 2023;
originally announced December 2023.
-
Track length measurement of $^{19}$F$^+$ ions with the MIMAC Dark Matter directional detector prototype
Authors:
Y. Tao,
C. Beaufort,
I. Moric,
C. Tao,
D. Santos,
N. Sauzet,
C. Couturier,
O. Guillaudin,
J. F. Muraz,
F. Naraghi,
N. Zhou,
J. Busto
Abstract:
Weakly Interacting Massive Particles (WIMPs) are one of the most preferred candidate for Dark Matter. WIMPs should interact with the nuclei of detectors. If a robust signal is eventually observed in direct detection experiments, the best signature to confirm its Galactic origin would be the nuclear recoil track direction. The MIMAC collaboration has developed a low pressure gas detector providing…
▽ More
Weakly Interacting Massive Particles (WIMPs) are one of the most preferred candidate for Dark Matter. WIMPs should interact with the nuclei of detectors. If a robust signal is eventually observed in direct detection experiments, the best signature to confirm its Galactic origin would be the nuclear recoil track direction. The MIMAC collaboration has developed a low pressure gas detector providing both the kinetic energy and three-dimensional track reconstruction of nuclear recoils. In this paper we report the first ever observations of $^{19}$F nuclei tracks in a $5$ cm drift prototype MIMAC detector, in the low kinetic energy range ($6$-$26$ keV), using specially developed ion beam facilities. We have measured the recoil track lengths and found significant differences between our measurements and standard simulations. In order to understand these differences, we have performed a series of complementary experiments and simulations to study the impact of the diffusion and eventual systematics. We show an unexpected dependence of the number of read-out corresponding to the track on the electric field applied to the $512\ \mathrm{μm}$ gap of the Micromegas detector. We have introduced, based on the flash-ADC observable, corrections in order to reconstruct the physical 3D track length of the primary electron clouds proposing the physics behind these corrections. We show that diffusion and space charge effects need to be taken into account to explain the differences between measurements and standard simulations. These measurements and simulations may shed a new light on the high-gain TPC ionization signals in general and particularly at low energy.
△ Less
Submitted 26 March, 2020; v1 submitted 5 March, 2019;
originally announced March 2019.
-
Cathode signal in a TPC directional detector: implementation and validation measuring the drift velocity
Authors:
C. Couturier,
Q. Riffard,
N. Sauzet,
O. Guillaudin,
F. Naraghi,
D. Santos
Abstract:
Low-pressure gaseous TPCs are well suited detectors to correlate the directions of nuclear recoils to the galactic Dark Matter (DM) halo. Indeed, in addition to providing a measure of the energy deposition due to the elastic scattering of a DM particle on a nucleus in the target gas, they allow for the reconstruction of the track of the recoiling nucleus. In order to exclude the background events…
▽ More
Low-pressure gaseous TPCs are well suited detectors to correlate the directions of nuclear recoils to the galactic Dark Matter (DM) halo. Indeed, in addition to providing a measure of the energy deposition due to the elastic scattering of a DM particle on a nucleus in the target gas, they allow for the reconstruction of the track of the recoiling nucleus. In order to exclude the background events originating from radioactive decays on the surfaces of the detector materials within the drift volume, efforts are ongoing to precisely localize the track nuclear recoil in the drift volume along the axis perpendicular to the cathode plane. We report here the implementation of the measure of the signal induced on the cathode by the motion of the primary electrons toward the anode in a MIMAC chamber. As a validation, we performed an independent measurement of the drift velocity of the electrons in the considered gas mixture, correlating in time the cathode signal with the measure of the arrival times of the electrons on the anode.
△ Less
Submitted 20 November, 2017;
originally announced November 2017.
-
Directional detection of Dark Matter with the MIcro-tpc MAtrix of Chambers
Authors:
C. Couturier,
O. Guillaudin,
F. Naraghi,
Q. Riffard,
D. Santos,
N. Sauzet,
P. Colas,
E. Ferrer Ribas,
I. Giomataris,
J. Busto,
D. Fouchez,
C. Tao,
N. Zhou
Abstract:
Particles weakly interacting with ordinary matter, with an associated mass of the order of an atomic nucleus (WIMPs), are plausible candidates for Dark Matter. The direct detection of an elastic collision of a target nuclei induced by one of these WIMPs has to be discriminated from the signal produced by the neutrons, which leaves the same signal in a detector. The MIMAC (MIcro-tpc MAtrix of Chamb…
▽ More
Particles weakly interacting with ordinary matter, with an associated mass of the order of an atomic nucleus (WIMPs), are plausible candidates for Dark Matter. The direct detection of an elastic collision of a target nuclei induced by one of these WIMPs has to be discriminated from the signal produced by the neutrons, which leaves the same signal in a detector. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed an original prototype detector which combines a large pixelated Micromegas coupled with a fast, self-triggering, electronics. Aspects of the two-chamber module in operation in the Modane Underground Laboratory are presented: calibration, characterization of the $^{222}$Rn progeny. A new test bench combining a MIMAC chamber with the COMIMAC portable quenching line has been set up to characterize the 3D tracks of low energy ions in the MIMAC gas mixture: the preliminary results thereof are presented. Future steps are briefly discussed.
△ Less
Submitted 29 July, 2016;
originally announced July 2016.
-
Dark Matter directional detection: comparison of the track direction determination
Authors:
C. Couturier,
J. P. Zopounidis,
N. Sauzet,
F. Naraghi,
D. Santos
Abstract:
Several directional techniques have been proposed for a directional detection of Dark matter, among others anisotropic crystal detectors, nuclear emulsion plates, and low-pressure gaseous TPCs. The key point is to get access to the initial direction of the nucleus recoiling due to the elastic scattering by a WIMP. In this article, we aim at estimating, for each method, how the information of the r…
▽ More
Several directional techniques have been proposed for a directional detection of Dark matter, among others anisotropic crystal detectors, nuclear emulsion plates, and low-pressure gaseous TPCs. The key point is to get access to the initial direction of the nucleus recoiling due to the elastic scattering by a WIMP. In this article, we aim at estimating, for each method, how the information of the recoil track initial direction is preserved in different detector materials. We use the SRIM simulation code to emulate the motion of the first recoiling nucleus in each material. We propose the use of a new observable, D, to quantify the preservation of the initial direction of the recoiling nucleus in the detector. We show that in an emulsion mix and an anisotropic crystal, the initial direction is lost very early, while in a typical TPC gas mix, the direction is well preserved.
△ Less
Submitted 16 January, 2017; v1 submitted 27 July, 2016;
originally announced July 2016.