Building the analytical response in frequency domain of AC biased bolometers Application to Planck/HFI
Authors:
Alexandre Sauvé,
Ludovic Montier
Abstract:
Context: Bolometers are high sensitivity detector commonly used in Infrared astronomy. The HFI instrument of the Planck satellite makes extensive use of them, but after the satellite launch two electronic related problems revealed critical. First an unexpected excess response of detectors at low optical excitation frequency for ν < 1 Hz, and secondly the Analog To digital Converter (ADC) component…
▽ More
Context: Bolometers are high sensitivity detector commonly used in Infrared astronomy. The HFI instrument of the Planck satellite makes extensive use of them, but after the satellite launch two electronic related problems revealed critical. First an unexpected excess response of detectors at low optical excitation frequency for ν < 1 Hz, and secondly the Analog To digital Converter (ADC) component had been insufficiently characterized on-ground. These two problems require an exquisite knowledge of detector response. However bolometers have highly nonlinear characteristics, coming from their electrical and thermal coupling making them very difficult to modelize.
Goal: We present a method to build the analytical transfer function in frequency domain which describe the voltage response of an Alternative Current (AC) biased bolometer to optical excitation, based on the standard bolometer model. This model is built using the setup of the Planck/HFI instrument and offers the major improvement of being based on a physical model rather than the currently in use had-hoc model based on Direct Current (DC) bolometer theory.
Method: The analytical transfer function expression will be presented in matrix form. For this purpose, we build linearized versions of the bolometer electro thermal equilibrium. And a custom description of signals in frequency is used to solve the problem with linear algebra. The model performances is validated using time domain simulations.
Results: The provided expression is suitable for calibration and data process- ing. It can also be used to provide constraints for fitting optical transfer function using real data from steady state electronic response and optical response. The accurate description of electronic response can also be used to improve the ADC nonlinearity correction for quickly varying optical signals.
△ Less
Submitted 3 May, 2016;
originally announced May 2016.
-
Planck 2015 results. XXII. A map of the thermal Sunyaev-Zeldovich effect
Authors:
Planck Collaboration,
N. Aghanim,
M. Arnaud,
M. Ashdown,
J. Aumont,
C. Baccigalupi,
A. J. Banday,
R. B. Barreiro,
J. G. Bartlett,
N. Bartolo,
E. Battaner,
R. Battye,
K. Benabed,
A. Benoît,
A. Benoit-Lévy,
J. -P. Bernard,
M. Bersanelli,
P. Bielewicz,
J. J. Bock,
A. Bonaldi,
L. Bonavera,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
C. Burigana
, et al. (177 additional authors not shown)
Abstract:
We have constructed all-sky y-maps of the thermal Sunyaev-Zeldovich (tSZ) effect by applying specifically tailored component separation algorithms to the 30 to 857 GHz frequency channel maps from the Planck satellite survey. These reconstructed y-maps are delivered as part of the Planck 2015 release. The y-maps are characterised in terms of noise properties and residual foreground contamination, m…
▽ More
We have constructed all-sky y-maps of the thermal Sunyaev-Zeldovich (tSZ) effect by applying specifically tailored component separation algorithms to the 30 to 857 GHz frequency channel maps from the Planck satellite survey. These reconstructed y-maps are delivered as part of the Planck 2015 release. The y-maps are characterised in terms of noise properties and residual foreground contamination, mainly thermal dust emission at large angular scales and CIB and extragalactic point sources at small angular scales. Specific masks are defined to minimize foreground residuals and systematics. Using these masks we compute the y-map angular power spectrum and higher order statistics. From these we conclude that the y-map is dominated by tSZ signal in the multipole range, 20-600. We compare the measured tSZ power spectrum and higher order statistics to various physically motivated models and discuss the implications of our results in terms of cluster physics and cosmology.
△ Less
Submitted 5 February, 2015;
originally announced February 2015.
-
Planck 2015 results. VIII. High Frequency Instrument data processing: Calibration and maps
Authors:
Planck Collaboration,
R. Adam,
P. A. R. Ade,
N. Aghanim,
M. Arnaud,
M. Ashdown,
J. Aumont,
C. Baccigalupi,
A. J. Banday,
R. B. Barreiro,
N. Bartolo,
E. Battaner,
K. Benabed,
A. Benoît,
A. Benoit-Lévy,
J. -P. Bernard,
M. Bersanelli,
B. Bertincourt,
P. Bielewicz,
J. J. Bock,
L. Bonavera,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
F. Boulanger
, et al. (201 additional authors not shown)
Abstract:
This paper describes the processing applied to the Planck High Frequency Instrument (HFI) cleaned, time-ordered information to produce photometrically calibrated maps in temperature and (for the first time) in polarization. The data from the entire 2.5 year HFI mission include almost five independent full-sky surveys. HFI observes the sky over a broad range of frequencies, from 100 to 857 GHz. To…
▽ More
This paper describes the processing applied to the Planck High Frequency Instrument (HFI) cleaned, time-ordered information to produce photometrically calibrated maps in temperature and (for the first time) in polarization. The data from the entire 2.5 year HFI mission include almost five independent full-sky surveys. HFI observes the sky over a broad range of frequencies, from 100 to 857 GHz. To obtain the best accuracy on the calibration over such a large range, two different photometric calibration schemes have been used. The 545 and 857 GHz data are calibrated using models of planetary atmospheric emission. The lower frequencies (from 100 to 353 GHz) are calibrated using the time-variable cosmological microwave background dipole, which we call the "orbital dipole". This source of calibration only depends on the satellite velocity with respect to the solar system. Using a CMB temperature of 2.7255 +/- 0.0006 K, it permits an independent measurement of the amplitude of the CMB solar dipole (3364.3 +/- 1.5 μK) which is approximatively 1σ higher than the WMAP measurement with a direction that is consistent between both experiments. We describe the pipeline used to produce the maps of intensity and linear polarization from the HFI timelines, and the scheme used to set the zero level of the maps a posteriori. We also summarize the noise characteristics of the HFI maps in the 2015 Planck data release and present some null tests to assess their quality. Finally, we discuss the major systematic effects and in particular the leakage induced by flux mismatch between the detectors that leads to spurious polarization signal.
△ Less
Submitted 17 July, 2015; v1 submitted 5 February, 2015;
originally announced February 2015.
-
Planck 2015 results. VII. HFI TOI and beam processing
Authors:
Planck Collaboration,
R. Adam,
P. A. R. Ade,
N. Aghanim,
M. Arnaud,
M. Ashdown,
J. Aumont,
C. Baccigalupi,
A. J. Banday,
R. B. Barreiro,
N. Bartolo,
E. Battaner,
K. Benabed,
A. Benoit,
A. Benoit-Levy,
J. -P. Bernard,
M. Bersanelli,
B. Bertincourt,
P. Bielewicz,
J. J. Bock,
L. Bonavera,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
F. Boulanger
, et al. (203 additional authors not shown)
Abstract:
The Planck High Frequency Instrument (HFI) has observed the full sky at six frequencies (100, 143, 217, 353, 545, and 857 GHz) in intensity and at four frequencies in linear polarization (100, 143, 217, and 353 GHz). In order to obtain sky maps, the time-ordered information (TOI) containing the detector and pointing samples must be processed and the angular response must be assessed. The full miss…
▽ More
The Planck High Frequency Instrument (HFI) has observed the full sky at six frequencies (100, 143, 217, 353, 545, and 857 GHz) in intensity and at four frequencies in linear polarization (100, 143, 217, and 353 GHz). In order to obtain sky maps, the time-ordered information (TOI) containing the detector and pointing samples must be processed and the angular response must be assessed. The full mission TOI is included in the Planck 2015 release. This paper describes the HFI TOI and beam processing for the 2015 release. HFI calibration and map-making are described in a companion paper. The main pipeline has been modified since the last release (2013 nominal mission in intensity only), by including a correction for the non-linearity of the warm readout and by improving the model of the bolometer time response. The beam processing is an essential tool that derives the angular response used in all the Planck science papers and we report an improvement in the effective beam window function uncertainty of more than a factor 10 relative to the 2013 release. Noise correlations introduced by pipeline filtering function are assessed using dedicated simulations. Angular cross-power spectra using datasets that are decorrelated in time are immune to the main systematic effects.
△ Less
Submitted 17 July, 2015; v1 submitted 5 February, 2015;
originally announced February 2015.
-
Planck 2015 results. I. Overview of products and scientific results
Authors:
Planck Collaboration,
R. Adam,
P. A. R. Ade,
N. Aghanim,
Y. Akrami,
M. I. R. Alves,
M. Arnaud,
F. Arroja,
J. Aumont,
C. Baccigalupi,
M. Ballardini,
A. J. Banday,
R. B. Barreiro,
J. G. Bartlett,
N. Bartolo,
S. Basak,
P. Battaglia,
E. Battaner,
R. Battye,
K. Benabed,
A. Benoît,
A. Benoit-Lévy,
J. -P. Bernard,
M. Bersanelli,
B. Bertincourt
, et al. (330 additional authors not shown)
Abstract:
The European Space Agency's Planck satellite, dedicated to studying the early Universe and its subsequent evolution, was launched 14~May 2009 and scanned the microwave and submillimetre sky continuously between 12~August 2009 and 23~October 2013. In February~2015, ESA and the Planck Collaboration released the second set of cosmology products based on data from the entire Planck mission, including…
▽ More
The European Space Agency's Planck satellite, dedicated to studying the early Universe and its subsequent evolution, was launched 14~May 2009 and scanned the microwave and submillimetre sky continuously between 12~August 2009 and 23~October 2013. In February~2015, ESA and the Planck Collaboration released the second set of cosmology products based on data from the entire Planck mission, including both temperature and polarization, along with a set of scientific and technical papers and a web-based explanatory supplement. This paper gives an overview of the main characteristics of the data and the data products in the release, as well as the associated cosmological and astrophysical science results and papers. The science products include maps of the cosmic microwave background (CMB), the thermal Sunyaev-Zeldovich effect, and diffuse foregrounds in temperature and polarization, catalogues of compact Galactic and extragalactic sources (including separate catalogues of Sunyaev-Zeldovich clusters and Galactic cold clumps), and extensive simulations of signals and noise used in assessing the performance of the analysis methods and assessment of uncertainties. The likelihood code used to assess cosmological models against the Planck data are described, as well as a CMB lensing likelihood. Scientific results include cosmological parameters deriving from CMB power spectra, gravitational lensing, and cluster counts, as well as constraints on inflation, non-Gaussianity, primordial magnetic fields, dark energy, and modified gravity.
△ Less
Submitted 9 August, 2015; v1 submitted 5 February, 2015;
originally announced February 2015.
-
Impact of particles on the Planck HFI detectors: Ground-based measurements and physical interpretation
Authors:
A. Catalano,
P. Ade,
Y. Atik,
A. Benoit,
E. Bréele,
J. J. Bock,
P. Camus,
M. Chabot,
M. Charra,
B. P. Crill,
N. Coron,
A. Coulais,
F. -X. Désert,
L. Fauvet,
Y. Giraud-Héraud,
O. Guillaudin,
W. Holmes,
W. C. Jones,
J. -M. Lamarre,
J. Macías-Pérez,
M. Martinez,
A. Miniussi,
A. Monfardini,
F. Pajot,
G. Patanchon
, et al. (9 additional authors not shown)
Abstract:
The Planck High Frequency Instrument (HFI) surveyed the sky continuously from August 2009 to January 2012. Its noise and sensitivity performance were excellent, but the rate of cosmic ray impacts on the HFI detectors was unexpectedly high. Furthermore, collisions of cosmic rays with the focal plane produced transient signals in the data (glitches) with a wide range of characteristics. A study of c…
▽ More
The Planck High Frequency Instrument (HFI) surveyed the sky continuously from August 2009 to January 2012. Its noise and sensitivity performance were excellent, but the rate of cosmic ray impacts on the HFI detectors was unexpectedly high. Furthermore, collisions of cosmic rays with the focal plane produced transient signals in the data (glitches) with a wide range of characteristics. A study of cosmic ray impacts on the HFI detector modules has been undertaken to categorize and characterize the glitches, to correct the HFI time-ordered data, and understand the residual effects on Planck maps and data products. This paper presents an evaluation of the physical origins of glitches observed by the HFI detectors. In order to better understand the glitches observed by HFI in flight, several ground-based experiments were conducted with flight-spare HFI bolometer modules. The experiments were conducted between 2010 and 2013 with HFI test bolometers in different configurations using varying particles and impact energies. The bolometer modules were exposed to 23 MeV protons from the Orsay IPN TANDEM accelerator, and to $^{241}$Am and $^{244}$Cm $α$-particle and $^{55}$Fe radioactive X-ray sources. The calibration data from the HFI ground-based preflight tests were used to further characterize the glitches and compare glitch rates with statistical expectations under laboratory conditions. Test results provide strong evidence that the dominant family of glitches observed in flight are due to cosmic ray absorption by the silicon die substrate on which the HFI detectors reside. Glitch energy is propagated to the thermistor by ballistic phonons, while there is also a thermal diffusion contribution. The implications of these results for future satellite missions, especially those in the far-infrared to sub-millimetre and millimetre regions of the electromagnetic spectrum, are discussed.
△ Less
Submitted 2 September, 2014; v1 submitted 26 March, 2014;
originally announced March 2014.
-
Characterization and Physical Explanation of Energetic Particles on Planck HFI Instrument
Authors:
A. Catalano,
P. Ade,
Y. Atik,
A. Benoit,
E. Bréele,
J. J. Bock,
P. Camus,
M. Charra,
B. P. Crill,
N. Coron,
A. Coulais,
F. -X. Désert,
L. Fauvet,
Y. Giraud-Héraud,
O. Guillaudin,
W. Holmes,
W. C. Jones,
J. -M. Lamarre,
J. Macías-Pérez,
M. Martinez,
A. Miniussi,
A. Monfardini,
F. Pajot,
G. Patanchon,
A. Pelissier
, et al. (8 additional authors not shown)
Abstract:
The Planck High Frequency Instrument (HFI) has been surveying the sky continuously from the second Lagrangian point (L2) between August 2009 and January 2012. It operates with 52 high impedance bolometers cooled at 100mK in a range of frequency between 100 GHz and 1THz with unprecedented sensivity, but strong coupling with cosmic radiation. At L2, the particle flux is about 5 $cm^{-2} s^{-1}$ and…
▽ More
The Planck High Frequency Instrument (HFI) has been surveying the sky continuously from the second Lagrangian point (L2) between August 2009 and January 2012. It operates with 52 high impedance bolometers cooled at 100mK in a range of frequency between 100 GHz and 1THz with unprecedented sensivity, but strong coupling with cosmic radiation. At L2, the particle flux is about 5 $cm^{-2} s^{-1}$ and is dominated by protons incident on the spacecraft. Protons with an energy above 40MeV can penetrate the focal plane unit box causing two different effects: glitches in the raw data from direct interaction of cosmic rays with detectors (producing a data loss of about 15% at the end of the mission) and thermal drifts in the bolometer plate at 100mK adding non-gaussian noise at frequencies below 0.1Hz. The HFI consortium has made strong efforts in order to correct for this effect on the time ordered data and final Planck maps. This work intends to give a view of the physical explanation of the glitches observed in the HFI instrument in-flight. To reach this goal, we performed several ground-based experiments using protons and $α$ particles to test the impact of particles on the HFI spare bolometers with a better control of the environmental conditions with respect to the in-flight data. We have shown that the dominant part of glitches observed in the data comes from the impact of cosmic rays in the silicon die frame supporting the micro-machinced bolometric detectors propagating energy mainly by ballistic phonons and by thermal diffusion. The implications of these results for future satellite missions will be discussed.
△ Less
Submitted 22 March, 2014;
originally announced March 2014.
-
Planck 2013 results X. Energetic particle effects: characterization, removal, and simulation
Authors:
Planck Collaboration,
P. A. R. Ade,
N. Aghanim,
C. Armitage-Caplan,
M. Arnaud,
M. Ashdown,
F. Atrio-Barandela,
J. Aumont,
C. Baccigalupi,
A. J. Banday,
R. B. Barreiro,
E. Battaner,
K. Benabed,
A. Benoît,
A. Benoit-Lévy,
J. -P. Bernard,
M. Bersanelli,
P. Bielewicz,
J. Bobin,
J. J. Bock,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
M. Bridges,
M. Bucher
, et al. (189 additional authors not shown)
Abstract:
We describe the detection, interpretation, and removal of the signal resulting from interactions of high energy particles with the \Planck\ High Frequency Instrument (HFI). There are two types of interactions: heating of the 0.1\,K bolometer plate; and glitches in each detector time stream. The transient responses to detector glitch shapes are not simple single-pole exponential decays and fall int…
▽ More
We describe the detection, interpretation, and removal of the signal resulting from interactions of high energy particles with the \Planck\ High Frequency Instrument (HFI). There are two types of interactions: heating of the 0.1\,K bolometer plate; and glitches in each detector time stream. The transient responses to detector glitch shapes are not simple single-pole exponential decays and fall into three families. The glitch shape for each family has been characterized empirically in flight data and these shapes have been used to remove glitches from the detector time streams. The spectrum of the count rate per unit energy is computed for each family and a correspondence is made to the location on the detector of the particle hit. Most of the detected glitches are from Galactic protons incident on the die frame supporting the micro-machined bolometric detectors. In the \Planck\ orbit at L2, the particle flux is around $5\,{\rm cm}^{-2}\,{\rm s}^{-1}$ and is dominated by protons incident on the spacecraft with energy $>$39\,MeV, at a rate of typically one event per second per detector. Different categories of glitches have different signatures in the time stream. Two of the glitch types have a low amplitude component that decays over nearly 1\,s. This component produces excess noise if not properly removed from the time-ordered data. We have used a glitch detection and subtraction method based on the joint fit of population templates. The application of this novel glitch subtraction method removes excess noise from the time streams. Using realistic simulations, we find that this method does not introduce signal bias into the \Planck\ data.
△ Less
Submitted 4 August, 2023; v1 submitted 20 March, 2013;
originally announced March 2013.
-
Planck 2013 results. VII. HFI time response and beams
Authors:
Planck Collaboration,
P. A. R. Ade,
N. Aghanim,
C. Armitage-Caplan,
M. Arnaud,
M. Ashdown,
F. Atrio-Barandela,
J. Aumont,
C. Baccigalupi,
A. J. Banday,
R. B. Barreiro,
E. Battaner,
K. Benabed,
A. Benoît,
A. Benoit-Lévy,
J. -P. Bernard,
M. Bersanelli,
P. Bielewicz,
J. Bobin,
J. J. Bock,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
J. W. Bowyer,
M. Bridges
, et al. (198 additional authors not shown)
Abstract:
This paper characterizes the effective beams,the effective beam window functions and the associated errors for the Planck HFI detectors. The effective beam is the angular response including the effect of the optics,detectors,data processing and the scan strategy. The window function is the representation of this beam in the harmonic domain which is required to recover an unbiased measurement of th…
▽ More
This paper characterizes the effective beams,the effective beam window functions and the associated errors for the Planck HFI detectors. The effective beam is the angular response including the effect of the optics,detectors,data processing and the scan strategy. The window function is the representation of this beam in the harmonic domain which is required to recover an unbiased measurement of the CMB angular power spectrum. The HFI is a scanning instrument and its effective beams are the convolution of: (a) the optical response of the telescope and feeds;(b)the processing of the time-ordered data and deconvolution of the bolometric and electronic time response; and (c) the merging of several surveys to produce maps. The time response functions are measured using observations of Jupiter and Saturn and by minimizing survey difference residuals. The scanning beam is the post-deconvolution angular response of the instrument, and is characterized with observations of Mars. The main beam solid angles are determined to better than 0.5% at each HFI frequency band. Observations of Jupiter and Saturn limit near sidelobes (within 5deg) to about 0.1% of the total solid angle. Time response residuals remain as long tails in the scanning beams, but contribute less than 0.1% of the total. The bias and uncertainty in the beam products are estimated using ensembles of simulated planet observations that include the impact of instrumental noise and known systematic effects.The correlation structure of these ensembles is well-described by five error eigenmodes that are sub-dominant to sample variance and instrumental noise in the harmonic domain. A suite of consistency tests provide confidence that the error model represents a sufficient description of the data. The total error in the effective beam window functions is below 1% at 100GHz up to ell~1500$,and below 0.5% at 143 and 217GHz up to ~2000.
△ Less
Submitted 15 December, 2013; v1 submitted 20 March, 2013;
originally announced March 2013.
-
Planck 2013 results. VI. High Frequency Instrument data processing
Authors:
Planck Collaboration,
P. A. R. Ade,
N. Aghanim,
C. Armitage-Caplan,
M. Arnaud,
M. Ashdown,
F. Atrio-Barandela,
J. Aumont,
C. Baccigalupi,
A. J. Banday,
R. B. Barreiro,
E. Battaner,
K. Benabed,
A. Benoît,
A. Benoit-Lévy,
J. -P. Bernard,
M. Bersanelli,
P. Bielewicz,
J. Bobin,
J. J. Bock,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
F. Boulanger,
J. W. Bowyer
, et al. (213 additional authors not shown)
Abstract:
We describe the processing of the 531 billion raw data samples from the High Frequency Instrument (hereafter HFI), which we performed to produce six temperature maps from the first 473 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545, and 857 GHz with an angular resolution ranging from 9.7 to 4.6 arcmin. The detector noise per…
▽ More
We describe the processing of the 531 billion raw data samples from the High Frequency Instrument (hereafter HFI), which we performed to produce six temperature maps from the first 473 days of Planck-HFI survey data. These maps provide an accurate rendition of the sky emission at 100, 143, 217, 353, 545, and 857 GHz with an angular resolution ranging from 9.7 to 4.6 arcmin. The detector noise per (effective) beam solid angle is respectively, 10, 6, 12 and 39 microKelvin in HFI four lowest frequency channel (100--353 GHz) and 13 and 14 kJy/sr for the 545 and 857 GHz channels. Using the 143 GHz channel as a reference, these two high frequency channels are intercalibrated within 5% and the 353 GHz relative calibration is at the percent level. The 100 and 217 GHz channels, which together with the 143 GHz channel determine the high-multipole part of the CMB power spectrum (50 < l <2500), are intercalibrated at better than 0.2 %.
△ Less
Submitted 23 July, 2014; v1 submitted 20 March, 2013;