The James Webb Space Telescope Mission
Authors:
Jonathan P. Gardner,
John C. Mather,
Randy Abbott,
James S. Abell,
Mark Abernathy,
Faith E. Abney,
John G. Abraham,
Roberto Abraham,
Yasin M. Abul-Huda,
Scott Acton,
Cynthia K. Adams,
Evan Adams,
David S. Adler,
Maarten Adriaensen,
Jonathan Albert Aguilar,
Mansoor Ahmed,
Nasif S. Ahmed,
Tanjira Ahmed,
Rüdeger Albat,
Loïc Albert,
Stacey Alberts,
David Aldridge,
Mary Marsha Allen,
Shaune S. Allen,
Martin Altenburg
, et al. (983 additional authors not shown)
Abstract:
Twenty-six years ago a small committee report, building on earlier studies, expounded a compelling and poetic vision for the future of astronomy, calling for an infrared-optimized space telescope with an aperture of at least $4m$. With the support of their governments in the US, Europe, and Canada, 20,000 people realized that vision as the $6.5m$ James Webb Space Telescope. A generation of astrono…
▽ More
Twenty-six years ago a small committee report, building on earlier studies, expounded a compelling and poetic vision for the future of astronomy, calling for an infrared-optimized space telescope with an aperture of at least $4m$. With the support of their governments in the US, Europe, and Canada, 20,000 people realized that vision as the $6.5m$ James Webb Space Telescope. A generation of astronomers will celebrate their accomplishments for the life of the mission, potentially as long as 20 years, and beyond. This report and the scientific discoveries that follow are extended thank-you notes to the 20,000 team members. The telescope is working perfectly, with much better image quality than expected. In this and accompanying papers, we give a brief history, describe the observatory, outline its objectives and current observing program, and discuss the inventions and people who made it possible. We cite detailed reports on the design and the measured performance on orbit.
△ Less
Submitted 10 April, 2023;
originally announced April 2023.
Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays
Authors:
M. A. Leutenegger,
M. E. Eckart,
S. J. Moseley,
S. O. Rohrbach,
J. K. Black,
M. P. Chiao,
R. L. Kelley,
C. A. Kilbourne,
F. S. Porter
Abstract:
X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening, and can add systematic uncertainty if the…
▽ More
X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening, and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals which are aligned in a dispersive configuration to select the \kaone line of the x-ray tube anode material. The entire device, including x-ray tube, can be easily hand carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100-200 $μ$m for the x-ray tubes used here), and is unfocused in the cross-dispersion direction, so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi Soft X-ray Spectrometer, which had 819 $μ$m square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs) which have effective theoretical FWHM energy resolution of 0.125, 0.197, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our \crkaone monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.
△ Less
Submitted 13 August, 2020;
originally announced August 2020.