-
GAPS contributions to the 38th International Cosmic Ray Conference (Nagoya 2023)
Authors:
T. Aramaki,
M. Boezio,
S. E. Boggs,
V. Bonvicini,
G. Bridges,
D. Campana,
W. W. Craig,
P. von Doetinchem,
E. Everson,
L. Fabris,
S. Feldman,
H. Fuke,
F. Gahbauer,
C. Gerrity,
L. Ghislotti,
C. J. Hailey,
T. Hayashi,
A. Kawachi,
M. Kozai,
P. Lazzaroni,
M. Law,
A. Lenni,
A. Lowell,
M. Manghisoni,
N. Marcelli
, et al. (33 additional authors not shown)
Abstract:
Compilation of papers presented by the GAPS Collaboration at the 38th International Cosmic Ray Conference (ICRC), held July 26 through August 3, 2023 in Nagoya, Japan.
Compilation of papers presented by the GAPS Collaboration at the 38th International Cosmic Ray Conference (ICRC), held July 26 through August 3, 2023 in Nagoya, Japan.
△ Less
Submitted 16 October, 2023;
originally announced October 2023.
-
Sensitivity of the GAPS Experiment to Low-energy Cosmic-ray Antiprotons
Authors:
Field Rogers,
Tsuguo Aramaki,
Mirko Boezio,
Steven Boggs,
Valter Bonvicini,
Gabriel Bridges,
Donatella Campana,
William W. Craig,
Philip von Doetinchem,
Eric Everson,
Lorenzo Fabris,
Sydney Feldman,
Hideyuki Fuke,
Florian Gahbauer,
Cory Gerrity,
Charles J. Hailey,
Takeru Hayashi,
Akiko Kawachi,
Masayoshi Kozai,
Alex Lenni,
Alexander Lowell,
Massimo Manghisoni,
Nadir Marcelli,
Brent Mochizuki,
Isaac Mognet
, et al. (28 additional authors not shown)
Abstract:
The General Antiparticle Spectrometer (GAPS) is an upcoming balloon mission to measure low-energy cosmic-ray antinuclei during at least three ~35-day Antarctic flights. With its large geometric acceptance and novel exotic atom-based particle identification, GAPS will detect ~500 cosmic antiprotons per flight and produce a precision cosmic antiproton spectrum in the kinetic energy range of ~0.07-0.…
▽ More
The General Antiparticle Spectrometer (GAPS) is an upcoming balloon mission to measure low-energy cosmic-ray antinuclei during at least three ~35-day Antarctic flights. With its large geometric acceptance and novel exotic atom-based particle identification, GAPS will detect ~500 cosmic antiprotons per flight and produce a precision cosmic antiproton spectrum in the kinetic energy range of ~0.07-0.21 GeV/n at the top of the atmosphere. With these high statistics extending to lower energies than any previous experiment, and with complementary sources of experimental uncertainty compared to traditional magnetic spectrometers, the GAPS antiproton measurement will be sensitive to dark matter, primordial black holes, and cosmic ray propagation. The antiproton measurement will also validate the GAPS antinucleus identification technique for the antideuteron and antihelium rare-event searches. This analysis demonstrates the GAPS sensitivity to cosmic-ray antiprotons using a full instrument simulation and event reconstruction, and including solar and atmospheric effects.
△ Less
Submitted 5 November, 2022; v1 submitted 26 June, 2022;
originally announced June 2022.
-
Cosmic antihelium-3 nuclei sensitivity of the GAPS experiment
Authors:
N. Saffold,
T. Aramaki,
R. Bird,
M. Boezio,
S. E. Boggs,
V. Bonvicini,
D. Campana,
W. W. Craig,
P. von Doetinchem,
E. Everson,
L. Fabris,
H. Fuke,
F. Gahbauer,
I. Garcia,
C. Gerrity,
C. J. Hailey,
T. Hayashi,
C. Kato,
A. Kawachi,
S. Kobayashi,
M. Kozai,
A. Lenni,
A. Lowell,
M. Manghisoni,
N. Marcelli
, et al. (30 additional authors not shown)
Abstract:
The General Antiparticle Spectrometer (GAPS) is an Antarctic balloon experiment designed for low-energy (0.1$-$0.3 GeV/$n$) cosmic antinuclei as signatures of dark matter annihilation or decay. GAPS is optimized to detect low-energy antideuterons, as well as to provide unprecedented sensitivity to low-energy antiprotons and antihelium nuclei. The novel GAPS antiparticle detection technique, based…
▽ More
The General Antiparticle Spectrometer (GAPS) is an Antarctic balloon experiment designed for low-energy (0.1$-$0.3 GeV/$n$) cosmic antinuclei as signatures of dark matter annihilation or decay. GAPS is optimized to detect low-energy antideuterons, as well as to provide unprecedented sensitivity to low-energy antiprotons and antihelium nuclei. The novel GAPS antiparticle detection technique, based on the formation, decay, and annihilation of exotic atoms, provides greater identification power for these low-energy antinuclei than previous magnetic spectrometer experiments. This work reports the sensitivity of GAPS to detect antihelium-3 nuclei, based on full instrument simulation, event reconstruction, and realistic atmospheric influence simulations. The report of antihelium nuclei candidate events by AMS-02 has generated considerable interest in antihelium nuclei as probes of dark matter and other beyond the Standard Model theories. GAPS is in a unique position to detect or set upper limits on the cosmic antihelium nuclei flux in an energy range that is essentially free of astrophysical background. In three 35-day long-duration balloon flights, GAPS will be sensitive to an antihelium flux on the level of $1.3^{+4.5}_{-1.2}\cdot 10^{-6}\mathrm{m^{-2}sr^{-1}s^{-1}}(\mathrm{GeV}/n)^{-1}$ (95% confidence level) in the energy range of 0.11$-$0.3 GeV/$n$, opening a new window on rare cosmic physics.
△ Less
Submitted 14 April, 2021; v1 submitted 10 December, 2020;
originally announced December 2020.
-
Large-area Si(Li) Detectors for X-ray Spectrometry and Particle Tracking for the GAPS Experiment
Authors:
Field Rogers,
Mengjiao Xiao,
Kerstin Perez,
Steven Boggs,
Tyler Erjavec,
Lorenzo Fabris,
Hideyuki Fuke,
Charles J. Hailey,
Masayoshi Kozai,
Alex Lowell,
Norman Madden,
Massimo Manghisoni,
Steve McBride,
Valerio Re,
Elisa Riceputi,
Nathan Saffold,
Yuki Shimizu,
Gianluigi Zampa
Abstract:
Large-area lithium-drifted silicon (Si(Li)) detectors, operable 150°C above liquid nitrogen temperature, have been developed for the General Antiparticle Spectrometer (GAPS) balloon mission and will form the first such system to operate in space. These 10 cm-diameter, 2.5 mm-thick multi-strip detectors have been verified in the lab to provide <4 keV FWHM energy resolution for X-rays as well as tra…
▽ More
Large-area lithium-drifted silicon (Si(Li)) detectors, operable 150°C above liquid nitrogen temperature, have been developed for the General Antiparticle Spectrometer (GAPS) balloon mission and will form the first such system to operate in space. These 10 cm-diameter, 2.5 mm-thick multi-strip detectors have been verified in the lab to provide <4 keV FWHM energy resolution for X-rays as well as tracking capability for charged particles, while operating in conditions (~-40°C and ~1 Pa) achievable on a long-duration balloon mission with a large detector payload. These characteristics enable the GAPS silicon tracker system to identify cosmic antinuclei via a novel technique based on exotic atom formation, de-excitation, and annihilation. Production and large-scale calibration of ~1000 detectors has begun for the first GAPS flight, scheduled for late 2021. The detectors developed for GAPS may also have other applications, for example in heavy nuclei identification.
△ Less
Submitted 13 December, 2019;
originally announced December 2019.
-
Front-end electronics for the GAPS tracker
Authors:
Valentina Scotti,
Alfonso Boiano,
Lorenzo Fabris,
Massimo Manghisoni,
Giuseppe Osteria,
Elisa Riceputi,
Francesco Perfetto,
Valerio Re,
Gianluigi Zampa
Abstract:
The General Antiparticle Spectrometer (GAPS) is an Antarctic balloon-borne mission to indirectly search for dark matter through sensitive observation of cosmic antiparticles. The first flight is planned for late 2021. GAPS is the first experiment optimized specifically for detection of low-energy (< 0.25 GeV/n) antideuterons, which are recognized as distinctive signals from dark matter annihilatio…
▽ More
The General Antiparticle Spectrometer (GAPS) is an Antarctic balloon-borne mission to indirectly search for dark matter through sensitive observation of cosmic antiparticles. The first flight is planned for late 2021. GAPS is the first experiment optimized specifically for detection of low-energy (< 0.25 GeV/n) antideuterons, which are recognized as distinctive signals from dark matter annihilation or decay in the Galactic halo. To achieve high sensitivity to cosmic antinuclei in this low-energy range, GAPS uses a novel particle identification method based on exotic atom capture and decay. The GAPS instrument consists of ten planes of 1440 10 cm-diameter, 2.5 mm-thick, 8-strip lithium drifted silicon (Si(Li)) detectors, which constitutes the tracker, surrounded by a plastic scintillator time-of-flight system. A new fabrication technique has been developed to satisfy the stringent requirements of the mission. In this contribution, we describe the front-end electronics of the tracker of GAPS. The system is composed of front-end ASICs and power supplies. The ASICs provide readout and digitization of the signal (with an 11-bit ADC) in a wide dynamic range (10 keV - 100 MeV). Every ASIC has 32 channels and performs the readout for 4 detectors, for a total amount of 11520 channels. The ASIC analog front-end is based on a dynamic compression technique to handle a large range of signal amplitudes and features a low noise performance, achieving the required 4 keV resolution at low energies. The power system supplies both bias voltages for the Si(Li) detectors and low voltages for the electronics. 36th
△ Less
Submitted 4 September, 2019;
originally announced September 2019.
-
GAPS: Searching for Dark Matter using Antinuclei in Cosmic Rays
Authors:
R. Bird,
T. Aramaki,
M. Boezio,
S. E. Boggs,
V. Bonvicini,
D. Campana,
W. W. Craig,
E. Everson,
L. Fabris,
H. Fuke,
F. Gahbauer,
I. Garcia,
C. Gerrity,
C. J. Hailey,
T. Hayashi,
C. Kato,
A. Kawachi,
M. Kondo,
M. Kozai,
A. Lowell,
M. Manghisoni,
N. Marcelli,
M. Martucci,
S. I. Mognet,
K. Munakata
, et al. (25 additional authors not shown)
Abstract:
The General Antiparticle Spectrometer (GAPS) will carry out a sensitive dark matter search by measuring low-energy ($\mathrm{E} < 0.25 \mathrm{GeV/nucleon}$) cosmic ray antinuclei. The primary targets are low-energy antideuterons produced in the annihilation or decay of dark matter. At these energies antideuterons from secondary/tertiary interactions are expected to have very low fluxes, significa…
▽ More
The General Antiparticle Spectrometer (GAPS) will carry out a sensitive dark matter search by measuring low-energy ($\mathrm{E} < 0.25 \mathrm{GeV/nucleon}$) cosmic ray antinuclei. The primary targets are low-energy antideuterons produced in the annihilation or decay of dark matter. At these energies antideuterons from secondary/tertiary interactions are expected to have very low fluxes, significantly below those predicted by well-motivated, beyond the standard model theories. GAPS will also conduct low-energy antiproton and antihelium searches. Combined, these observations will provide a powerful search for dark matter and provide the best observations to date on primordial black hole evaporation on Galactic length scales.
The GAPS instrument detects antinuclei using the novel exotic atom technique. It consists of a central tracker with a surrounding time-of-flight (TOF) system. The tracker is a one cubic meter volume containing 10 cm-diameter lithium-drifted silicon (Si(Li)) detectors. The TOF is a plastic scintillator system that will both trigger the Si(Li) tracker and enable better reconstruction of particle tracks. After coming to rest in the tracker, antinuclei will form an excited exotic atom. This will then de-excite via characteristic X-ray transitions before producing a pion/proton star when the antiparticle annihilates with the nucleus. This unique event topology will give GAPS the nearly background-free detection capability required for a rare-event search.
Here we present the scientific motivation for the GAPS experiment, its design and its current status as it prepares for flight in the austral summer of 2021-22.
△ Less
Submitted 8 August, 2019;
originally announced August 2019.
-
Large-area Si(Li) detectors for X-ray spectrometry and particle tracking in the GAPS experiment
Authors:
Field Rogers,
Mengjiao Xiao,
Kerstin M. Perez,
Steven Boggs,
Tyler Erjavec,
Lorenzo Fabris,
Hideyuki Fuke,
Charles J. Hailey,
Masayoshi Kozai,
Alex Lowell,
Norman Madden,
Massimo Manghisoni,
Steve McBride,
Valerio Re,
Elisa Riceputi,
Nathan Saffold,
Yuki Shimizu
Abstract:
The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique geometric, performance, and cost requirements of the General Antiparticle Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The GAPS Si(Li) detectors will form the first large-area, relatively high-temperature Si(Li) detector system with sensitivity to X-rays to operate at high altitude. These 10 cm…
▽ More
The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique geometric, performance, and cost requirements of the General Antiparticle Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The GAPS Si(Li) detectors will form the first large-area, relatively high-temperature Si(Li) detector system with sensitivity to X-rays to operate at high altitude. These 10 cm-diameter, 2.5 mm-thick, 4- or 8-strip detectors provide the active area, X-ray absorption efficiency, energy resolution, and particle tracking capability necessary for the GAPS exotic-atom particle identification technique. In this paper, the detector performance is validated on the bases of X-ray energy resolution and reconstruction of cosmic minimum ionizing particle (MIP) signals. We use the established noise model for semiconductor detectors to distinguish sources of noise due to the detector from those due to signal processing electronics. We demonstrate that detectors with either 4 strips or 8 strips can provide the required $\lesssim$4 keV (FWHM) X-ray energy resolution at flight temperatures of $-35$ to $-45^{\circ}$C, given the proper choice of signal processing electronics. Approximately 1000 8-strip detectors will be used for the first GAPS Antarctic balloon flight, scheduled for late 2021.
△ Less
Submitted 8 November, 2019; v1 submitted 31 May, 2019;
originally announced June 2019.