Development of MMC-based lithium molybdate cryogenic calorimeters for AMoRE-II
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
H. Bae,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
S. Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Y. M. Gavrilyuk,
A. M. Gezhaev
, et al. (84 additional authors not shown)
Abstract:
The AMoRE collaboration searches for neutrinoless double beta decay of $^{100}$Mo using molybdate scintillating crystals via low temperature thermal calorimetric detection. The early phases of the experiment, AMoRE-pilot and AMoRE-I, have demonstrated competitive discovery potential. Presently, the AMoRE-II experiment, featuring a large detector array with about 90 kg of $^{100}$Mo isotope, is und…
▽ More
The AMoRE collaboration searches for neutrinoless double beta decay of $^{100}$Mo using molybdate scintillating crystals via low temperature thermal calorimetric detection. The early phases of the experiment, AMoRE-pilot and AMoRE-I, have demonstrated competitive discovery potential. Presently, the AMoRE-II experiment, featuring a large detector array with about 90 kg of $^{100}$Mo isotope, is under construction. This paper discusses the baseline design and characterization of the lithium molybdate cryogenic calorimeters to be used in the AMoRE-II detector modules. The results from prototype setups that incorporate new housing structures and two different crystal masses (316 g and 517 - 521 g), operated at 10 mK temperature, show energy resolutions (FWHM) of 7.55 - 8.82 keV at the 2.615 MeV $^{208}$Tl $γ$ line, and effective light detection of 0.79 - 0.96 keV/MeV. The simultaneous heat and light detection enables clear separation of alpha particles with a discrimination power of 12.37 - 19.50 at the energy region around $^6$Li(n, $α$)$^3$H with Q-value = 4.785 MeV. Promising detector performances were demonstrated at temperatures as high as 30 mK, which relaxes the temperature constraints for operating the large AMoRE-II array.
△ Less
Submitted 3 March, 2025; v1 submitted 16 July, 2024;
originally announced July 2024.
Annual variations of the $^{214}$Po, $^{213}$Po and $^{212}$Po half-life values
Authors:
E. N. Alexeev,
A. M. Gangapshev,
Yu. M. Gavrilyuk,
A. M. Gezhaev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
O. D. Petrenko,
S. S. Ratkevich
Abstract:
Results of a comparative analysis of the $^{214}$Po ($T_{1/2}= 163.47\pm0.03$ $μ$s), $^{213}$Po ($T_{1/2}=3.705 \pm 0.001$ $μ$s) and $^{212}$Po ($T_{1/2}=294.09\pm0.07$ ns) half-life annular variation parameters are presented. It is shown that two independent sequential sets of the $^{214}$Po $τ$-values $(τ\equiv T_{1/2})$ obtained in the spaced laboratories can be described by sinusoidal function…
▽ More
Results of a comparative analysis of the $^{214}$Po ($T_{1/2}= 163.47\pm0.03$ $μ$s), $^{213}$Po ($T_{1/2}=3.705 \pm 0.001$ $μ$s) and $^{212}$Po ($T_{1/2}=294.09\pm0.07$ ns) half-life annular variation parameters are presented. It is shown that two independent sequential sets of the $^{214}$Po $τ$-values $(τ\equiv T_{1/2})$ obtained in the spaced laboratories can be described by sinusoidal functions. The sinusoid curve with amplitude $A=(5.0 \pm1.5) \cdot 10^{-4}$, period $ω=(365\pm 8)$ days, and phase $φ=(170 \pm 7)$ days approximates the set of $^{214}$Po $τ$ values obtained at BNO INR RAS during the $\sim$973 days starting on January 4, 2012. The function approximates a set of $τ$-values with a time duration of $\sim1460$ days obtained at the KhNU has an amplitude $A=(4.9\pm1.8)\cdot10^{-4}$, a period $ω= (377\pm13)$ days and a phase $φ=(77\pm10)$ days. The $^{213}$Po $τ$-value set with a time duration of $\sim1700$ days can be described by a sinusoidal function with an amplitude $A=(3.9\pm1.2)\cdot10^{-4}$, a period $ω= (370\pm13)$ days and a phase $φ=(130\pm9)$ days. The $^{212}$Po $τ$-value set with a time duration of $\sim670$ days can be described by a sinusoidal function with an amplitude $A=(7.5\pm1.6)\cdot10^{-4}$, a period $ω= (375\pm13)$ days and a phase $φ=(40\pm10)$ days.
△ Less
Submitted 16 October, 2020;
originally announced October 2020.
Results of a search for daily and annual variations of the Po-214 half-life at the two year observation period
Authors:
E. N. Alexeyev,
Yu. M. Gavrilyuk,
A. M. Gangapshev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
The brief description of installation TAU-2 intended for long-term monitoring of the half-life value $τ$ ($τ_{1/2}$) of the $^{214}$Po is presented. The methods of measurement and processing of collected data are reported. The results of analysis of time series values $τ$ with different time step are presented. Total of measurement time was equal to 590 days. Averaged value of the $^{214}$Po half-…
▽ More
The brief description of installation TAU-2 intended for long-term monitoring of the half-life value $τ$ ($τ_{1/2}$) of the $^{214}$Po is presented. The methods of measurement and processing of collected data are reported. The results of analysis of time series values $τ$ with different time step are presented. Total of measurement time was equal to 590 days. Averaged value of the $^{214}$Po half-life was obtained $τ=163.46\pm0.04$ $μ$s. The annual variation with an amplitude $A=(8.9\pm2.3)\cdot10^{-4}$, solar-daily variation with an amplitude $A_{So}=(7.5\pm1.2)\cdot10^{-4}$, lunar-daily variation with an amplitude $A_L=(6.9\pm2.0)\cdot10^{-4}$ and sidereal-daily variation with an amplitude $A_S=(7.2\pm1.2)\cdot10^{-4}$ were found in a series of $τ$ values. The maximal values of amplitude are observed at the moments when the projections of the installation Earth location velocity vectors toward the source of possible variation achieve its maximal magnitudes.
△ Less
Submitted 7 May, 2015;
originally announced May 2015.