-
A search for light dark matter in XENON10 data
Authors:
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey,
M. E. Monzani
, et al. (12 additional authors not shown)
Abstract:
We report results of a search for light (<10 GeV) particle dark matter with the XENON10 detector. The event trigger was sensitive to a single electron, with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear recoil energy. Considering spin-independent dark matter-nucleon scattering, we exclude cross sections σ_n>3.5x10^{-42} cm^2, for a dark matter particle mass m_χ=8 GeV. We f…
▽ More
We report results of a search for light (<10 GeV) particle dark matter with the XENON10 detector. The event trigger was sensitive to a single electron, with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear recoil energy. Considering spin-independent dark matter-nucleon scattering, we exclude cross sections σ_n>3.5x10^{-42} cm^2, for a dark matter particle mass m_χ=8 GeV. We find that our data strongly constrain recent elastic dark matter interpretations of excess low-energy events observed by CoGeNT and CRESST-II, as well as the DAMA annual modulation signal.
△ Less
Submitted 7 May, 2013; v1 submitted 15 April, 2011;
originally announced April 2011.
-
Lowering the low-energy threshold of xenon detectors
Authors:
P. Sorensen,
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey
, et al. (12 additional authors not shown)
Abstract:
We show that the energy threshold for nuclear recoils in the XENON10 dark matter search data can be lowered to ~1 keV, by using only the ionization signal. In other words, we make no requirement that a valid event contain a primary scintillation signal. We therefore relinquish incident particle type discrimination, which is based on the ratio of ionization to scintillation in liquid xenon. This me…
▽ More
We show that the energy threshold for nuclear recoils in the XENON10 dark matter search data can be lowered to ~1 keV, by using only the ionization signal. In other words, we make no requirement that a valid event contain a primary scintillation signal. We therefore relinquish incident particle type discrimination, which is based on the ratio of ionization to scintillation in liquid xenon. This method compromises the detector's ability to precisely determine the z coordinate of a particle interaction. However, we show for the first time that it is possible to discriminate bulk events from surface events based solely on the ionization signal.
△ Less
Submitted 29 November, 2010;
originally announced November 2010.
-
Design and Performance of the XENON10 Dark Matter Experiment
Authors:
E. Aprile,
J. Angle,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey,
M. E. Monzani
, et al. (14 additional authors not shown)
Abstract:
XENON10 is the first two-phase xenon time projection chamber (TPC) developed within the XENON dark matter search program. The TPC, with an active liquid xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground laboratory (LNGS) in Italy, and operated for more than one year, with excellent stability and performance. Results from a dark matter search with XENON10 have been publ…
▽ More
XENON10 is the first two-phase xenon time projection chamber (TPC) developed within the XENON dark matter search program. The TPC, with an active liquid xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground laboratory (LNGS) in Italy, and operated for more than one year, with excellent stability and performance. Results from a dark matter search with XENON10 have been published elsewhere. In this paper, we summarize the design and performance of the detector and its subsystems, based on calibration data using sources of gamma-rays and neutrons as well as background and Monte Carlo simulations data. The results on the detector's energy threshold, energy and position resolution, and overall efficiency show a performance that exceeds design specifications, in view of the very low energy threshold achieved (<10 keVr) and the excellent energy resolution achieved by combining the ionization and scintillation signals, detected simultaneously.
△ Less
Submitted 16 January, 2010;
originally announced January 2010.
-
Constraints on inelastic dark matter from XENON10
Authors:
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey,
M. E. Monzani
, et al. (12 additional authors not shown)
Abstract:
It has been suggested that dark matter particles which scatter inelastically from detector target nuclei could explain the apparent incompatibility of the DAMA modulation signal (interpreted as evidence for particle dark matter) with the null results from CDMS-II and XENON10. Among the predictions of inelastically interacting dark matter are a suppression of low-energy events, and a population of…
▽ More
It has been suggested that dark matter particles which scatter inelastically from detector target nuclei could explain the apparent incompatibility of the DAMA modulation signal (interpreted as evidence for particle dark matter) with the null results from CDMS-II and XENON10. Among the predictions of inelastically interacting dark matter are a suppression of low-energy events, and a population of nuclear recoil events at higher nuclear recoil equivalent energies. This is in stark contrast to the well-known expectation of a falling exponential spectrum for the case of elastic interactions. We present a new analysis of XENON10 dark matter search data extending to E$_{nr}=75$ keV nuclear recoil equivalent energy. Our results exclude a significant region of previously allowed parameter space in the model of inelastically interacting dark matter. In particular, it is found that dark matter particle masses $m_χ\gtrsim150$ GeV are disfavored.
△ Less
Submitted 30 November, 2010; v1 submitted 19 October, 2009;
originally announced October 2009.
-
The scintillation and ionization yield of liquid xenon for nuclear recoils
Authors:
P. Sorensen,
A. Manzur,
C. E. Dahl,
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
D. N. McKinsey
, et al. (12 additional authors not shown)
Abstract:
XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and ionization signal (S2), which are both functions of the deposited recoil energy and the incident particle type. We present a new precision measurement of the relati…
▽ More
XENON10 is an experiment designed to directly detect particle dark matter. It is a dual phase (liquid/gas) xenon time-projection chamber with 3D position imaging. Particle interactions generate a primary scintillation signal (S1) and ionization signal (S2), which are both functions of the deposited recoil energy and the incident particle type. We present a new precision measurement of the relative scintillation yield \leff and the absolute ionization yield Q_y, for nuclear recoils in xenon. A dark matter particle is expected to deposit energy by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for establishing the energy threshold of the experiment; this in turn determines the sensitivity to particle dark matter. Our \leff measurement is in agreement with recent theoretical predictions above 15 keV nuclear recoil energy, and the energy threshold of the measurement is 4 keV. A knowledge of the ionization yield \Qy is necessary to establish the trigger threshold of the experiment. The ionization yield \Qy is measured in two ways, both in agreement with previous measurements and with a factor of 10 lower energy threshold.
△ Less
Submitted 30 December, 2008; v1 submitted 3 July, 2008;
originally announced July 2008.
-
Limits on spin-dependent WIMP-nucleon cross-sections from the XENON10 experiment
Authors:
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey,
M. E. Monzani
, et al. (12 additional authors not shown)
Abstract:
XENON10 is an experiment to directly detect weakly interacting massive particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter in our Universe. We report new results for spin-dependent WIMP-nucleon interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a WIMP signal in 5.4 kg of…
▽ More
XENON10 is an experiment to directly detect weakly interacting massive particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter in our Universe. We report new results for spin-dependent WIMP-nucleon interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously unexplored regions in the theoretically allowed parameter space for neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range of 10 GeV -2 TeV as a dark matter candidate under standard assumptions for its density and distribution in the galactic halo.
△ Less
Submitted 10 September, 2008; v1 submitted 19 May, 2008;
originally announced May 2008.
-
First Results from the XENON10 Dark Matter Experiment at the Gran Sasso National Laboratory
Authors:
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
P. Brusov,
L. C. C. Coelho,
C. E. Dahl,
L. DeViveiros,
A. D. Ferella,
L. M. P. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. L. Giboni,
R. Gomez,
R. Hasty,
L. Kastens,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. N. McKinsey,
M. E. Monzani
, et al. (12 additional authors not shown)
Abstract:
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg xenon dual phase time projection chamber (XeTPC) to search for dark matter weakly interacting massive particles (WIMPs). The detector measures simultaneously the scintillation and the ionization produced by radiation in pure liquid xenon, to discriminate signal from background down to 4.5 keV nuclear recoil energy. A blind…
▽ More
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg xenon dual phase time projection chamber (XeTPC) to search for dark matter weakly interacting massive particles (WIMPs). The detector measures simultaneously the scintillation and the ionization produced by radiation in pure liquid xenon, to discriminate signal from background down to 4.5 keV nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4 kg, excludes previously unexplored parameter space, setting a new 90% C.L. upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x 10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a WIMP mass of 30 GeV/c^2. This result further constrains predictions of supersymmetric models.
△ Less
Submitted 3 December, 2007; v1 submitted 31 May, 2007;
originally announced June 2007.
-
3D Position Sensitive XeTPC for Dark Matter Search
Authors:
J. Angle,
E. Aprile,
F. Arneodo,
L. Baudis,
A. Bernstein,
A. Bolozdynya,
L. Coelho,
E. Dahl,
L. DeViveiros,
A. Ferella,
L. Fernandes,
S. Fiorucci,
R. J. Gaitskell,
K. -L. Giboni,
R. Gomez,
R. Hasty,
J. Kwong,
J. A. M. Lopes,
N. Madden,
A. Manalaysay,
A. Manzur,
D. McKinsey,
M. E. Monzani,
K. Ni,
U. Oberlack
, et al. (8 additional authors not shown)
Abstract:
The technique to realize 3D position sensitivity in a two-phase xenon time projection chamber (XeTPC) for dark matter search is described. Results from a prototype detector (XENON3) are presented.
The technique to realize 3D position sensitivity in a two-phase xenon time projection chamber (XeTPC) for dark matter search is described. Results from a prototype detector (XENON3) are presented.
△ Less
Submitted 26 September, 2006;
originally announced September 2006.
-
Performance of the AMS-02 Transition Radiation Detector
Authors:
P. v. Doetinchem,
S. Fopp,
W. Karpinski,
T. Kirn,
K. Luebelsmeyer,
J. Orboeck,
S. Schael,
A. Schultz von Dratzig,
G. Schwering,
T. Siedenburg,
R. Siedling,
W. Wallraff,
U. Becker,
J. Burger,
R. Henning,
A. Kounine,
V. Koutsenko,
J. Wyatt
Abstract:
For cosmic particle spectroscopy on the International Space Station the AMS experiment will be equipped with a Transition Radiation Detector (TRD) to improve particle identification. The TRD has 20 layers of fleece radiator with Xe/CO2 proportional mode straw tube chambers. They are supported in a conically shaped octagon structure made of CFC-Al-honeycomb. For low power consumption VA analog mu…
▽ More
For cosmic particle spectroscopy on the International Space Station the AMS experiment will be equipped with a Transition Radiation Detector (TRD) to improve particle identification. The TRD has 20 layers of fleece radiator with Xe/CO2 proportional mode straw tube chambers. They are supported in a conically shaped octagon structure made of CFC-Al-honeycomb. For low power consumption VA analog multiplexers are used as front-end readout. A 20 layer prototype built from final design components has achieved proton rejections from 100 to 2000 at 90% electron efficiency for proton beam energies up to 250 GeV with cluster counting, likelihood and neural net selection algorithms.
△ Less
Submitted 29 August, 2006;
originally announced August 2006.