Calibration of the Surface Array of the Pierre Auger Observatory
Authors:
X. Bertou,
P. S. Allison,
C. Bonifazi,
P. Bauleo,
C. M. Grunfeld,
M. Aglietta,
F. Arneodo,
D. Barnhill,
J. J. Beatty,
N. G. Busca,
A. Creusot,
D. Dornic,
A. Etchegoyen. A. Filevitch,
P. L. Ghia,
I. Lhenry-Yvon,
M. C. Medina,
E. Moreno,
D. Nitz,
T. Ohnuki,
S. Ranchon,
H. Salazar,
T. Suomijärvi,
D. Supanitsky,
A. Tripathi,
M. Urban
, et al. (1 additional authors not shown)
Abstract:
The Pierre Auger Observatory is designed to study cosmic rays of the highest energies ($>10^{19}$ eV). The ground array of the Observatory will consist of 1600 water Cherenkov detectors deployed over 3000 km^2. The remoteness and large number of detectors require a robust, automatic self-calibration procedure. It relies on the measurement of the average charge collected by a photomultiplier tube f…
▽ More
The Pierre Auger Observatory is designed to study cosmic rays of the highest energies ($>10^{19}$ eV). The ground array of the Observatory will consist of 1600 water Cherenkov detectors deployed over 3000 km^2. The remoteness and large number of detectors require a robust, automatic self-calibration procedure. It relies on the measurement of the average charge collected by a photomultiplier tube from the Cherenkov light produced by a vertical and central through-going muon determined to 5 - 10% at the detector via a novel rate-based technique and to 3% precision through analysis of histograms of the charge distribution. The parameters needed for the calibration are measured every minute, allowing for an accurate determination of the signals recorded from extensive air showers produced by primary cosmic rays. The method also enables stable and uniform triggering conditions to be achieved.
△ Less
Submitted 13 March, 2021; v1 submitted 2 February, 2021;
originally announced February 2021.
The DRIFT Project: Searching for WIMPS with a Directional Detector
Authors:
M. J. Lehner,
K. Griest,
C. J. Martoff,
G. E. Masek,
T. Ohnuki,
D. Snowden-Ifft,
N. J. C. Spooner
Abstract:
A low pressure time projection chamber for the detection of WIMPs is discussed. Discrimination against Compton electron background in such a device should be very good, and directional information about the recoil atoms would be obtainable. If a full 3-D reconstruction of the recoil tracks can be achieved, Monte Carlo studies indicate that a WIMP signal could be identified with high confidence f…
▽ More
A low pressure time projection chamber for the detection of WIMPs is discussed. Discrimination against Compton electron background in such a device should be very good, and directional information about the recoil atoms would be obtainable. If a full 3-D reconstruction of the recoil tracks can be achieved, Monte Carlo studies indicate that a WIMP signal could be identified with high confidence from as few as 30 detected WIMP-nucleus scattering events.
△ Less
Submitted 6 May, 1999;
originally announced May 1999.