-
QUBIC - The Q&U Bolometric Interferometer for Cosmology - A novel way to look at the polarized Cosmic Microwave Background
Authors:
A. Mennella,
P. A. R. Ade,
J. Aumont,
S. Banfi,
P. Battaglia,
E. S. Battistelli,
A. Baù,
B. Bélier,
D. Bennett,
L. Bergé,
J. Ph. Bernard,
M. Bersanelli,
M. A. Bigot-Sazy,
N. Bleurvacq,
G. Bordier,
J. Brossard,
E. F. Bunn,
D. P. Burke,
D. Buzi,
A. Buzzelli,
D. Cammilleri,
F. Cavaliere,
P. Chanial,
C. Chapron,
F. Columbro
, et al. (83 additional authors not shown)
Abstract:
In this paper we describe QUBIC, an experiment that takes up the challenge posed by the detection of primordial gravitational waves with a novel approach, that combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. The so-called "self-calibration" is a technique deeply rooted in the interferometric nature of the instrument…
▽ More
In this paper we describe QUBIC, an experiment that takes up the challenge posed by the detection of primordial gravitational waves with a novel approach, that combines the sensitivity of state-of-the art bolometric detectors with the systematic effects control typical of interferometers. The so-called "self-calibration" is a technique deeply rooted in the interferometric nature of the instrument and allows us to clean the measured data from instrumental effects. The first module of QUBIC is a dual band instrument (150 GHz and 220 GHz) that will be deployed in Argentina during the Fall 2018.
△ Less
Submitted 11 January, 2018;
originally announced January 2018.
-
Multi-Octave Metamaterial Reflective Half-Wave Plate for Millimetre and Sub-Millimetre wave Applications
Authors:
Giampaolo Pisano,
Bruno Maffei,
Peter A. R. Ade,
Paolo de Bernardis,
Peter De Maagt,
Brian Ellison,
Manju Henry,
Ming Wah Ng,
Brian Schortt,
Carole Tucker
Abstract:
The quasi-optical modulation of linear polarization at millimeter and sub-millimeter wavelengths can be achieved by using rotating half wave plates (HWPs) in front of polarization sensitive detectors. Large operational bandwidths are required when the same device is meant to work simultaneously across different frequency bands. Previous realizations of half wave plates, ranging from birefringent m…
▽ More
The quasi-optical modulation of linear polarization at millimeter and sub-millimeter wavelengths can be achieved by using rotating half wave plates (HWPs) in front of polarization sensitive detectors. Large operational bandwidths are required when the same device is meant to work simultaneously across different frequency bands. Previous realizations of half wave plates, ranging from birefringent multi-plate to mesh-based devices, have achieved bandwidths of the order of 100%. Here we present the design and the experimental characterization of a reflective HWP able to work across bandwidths of the order of 150%. The working principle of the novel device is completely different from any previous realization and it is based on the different phase-shift experienced by two orthogonal polarizations respectively reflecting off an electric conductor and off an artificial magnetic conductor.
△ Less
Submitted 3 October, 2016;
originally announced October 2016.
-
QUBIC Technical Design Report
Authors:
J. Aumont,
S. Banfi,
P. Battaglia,
E. S. Battistelli,
A. Baù,
B. Bélier,
D. Bennett,
L. Bergé,
J. Ph. Bernard,
M. Bersanelli,
M. A. Bigot-Sazy,
N. Bleurvacq,
G. Bordier,
J. Brossard,
E. F. Bunn,
D. Buzi,
A. Buzzelli,
D. Cammilleri,
F. Cavaliere,
P. Chanial,
C. Chapron,
G. Coppi,
A. Coppolecchia,
F. Couchot,
R. D'Agostino
, et al. (74 additional authors not shown)
Abstract:
QUBIC is an instrument aiming at measuring the B mode polarisation anisotropies at medium scales angular scales (30-200 multipoles). The search for the primordial CMB B-mode polarization signal is challenging, because of many difficulties: smallness of the expected signal, instrumental systematics that could possibly induce polarization leakage from the large E signal into B, brighter than anticip…
▽ More
QUBIC is an instrument aiming at measuring the B mode polarisation anisotropies at medium scales angular scales (30-200 multipoles). The search for the primordial CMB B-mode polarization signal is challenging, because of many difficulties: smallness of the expected signal, instrumental systematics that could possibly induce polarization leakage from the large E signal into B, brighter than anticipated polarized foregrounds (dust) reducing to zero the initial hope of finding sky regions clean enough to have a direct primordial B-modes observation. The QUBIC instrument is designed to address all aspects of this challenge with a novel kind of instrument, a Bolometric Interferometer, combining the background-limited sensitivity of Transition-Edge-Sensors and the control of systematics allowed by the observation of interference fringe patterns, while operating at two frequencies to disentangle polarized foregrounds from primordial B mode polarization. Its characteristics are described in details in this Technological Design Report.
△ Less
Submitted 11 May, 2017; v1 submitted 14 September, 2016;
originally announced September 2016.
-
Development of large radii half-wave plates for CMB satellite missions
Authors:
G. Pisano,
B. Maffei,
M. W. Ng,
V. Haynes,
M. Brown,
F. Noviello,
P. de Bernardis,
S. Masi,
F. Piacentini,
L. Pagano,
M. Salatino,
B. Ellison,
M. Henry,
P. de Maagt,
B. Shortt
Abstract:
The successful European Space Agency (ESA) Planck mission has mapped the Cosmic Microwave Background (CMB) temperature anisotropy with unprecedented accuracy. However, Planck was not designed to detect the polarised components of the CMB with comparable precision. The BICEP2 collaboration has recently reported the first detection of the B-mode polarisation. ESA is funding the development of critic…
▽ More
The successful European Space Agency (ESA) Planck mission has mapped the Cosmic Microwave Background (CMB) temperature anisotropy with unprecedented accuracy. However, Planck was not designed to detect the polarised components of the CMB with comparable precision. The BICEP2 collaboration has recently reported the first detection of the B-mode polarisation. ESA is funding the development of critical enabling technologies associated with B-mode polarisation detection, one of these being large diameter half-wave plates. We compare different polarisation modulators and discuss their respective trade-offs in terms of manufacturing, RF performance and thermo-mechanical properties. We then select the most appropriate solution for future satellite missions, optimized for the detection of B-modes.
△ Less
Submitted 30 September, 2014;
originally announced September 2014.
-
W-Band Pancharatnam Half Wave Plate Based on Negative Refractive Index Metamaterials
Authors:
Imran Mohamed,
Giampaolo Pisano,
Ming Wah Ng
Abstract:
Electromagnetic metamaterials, made from arrangements of subwavelength sized structures, can be used to manipulate radiation. Designing metamaterials that have a positive refractive index along one axis and a negative refractive index along the orthogonal axis can result in birefringences, $Δn>1$. The effect can be used to create wave plates with subwavelength thicknesses. Previous attempts at mak…
▽ More
Electromagnetic metamaterials, made from arrangements of subwavelength sized structures, can be used to manipulate radiation. Designing metamaterials that have a positive refractive index along one axis and a negative refractive index along the orthogonal axis can result in birefringences, $Δn>1$. The effect can be used to create wave plates with subwavelength thicknesses. Previous attempts at making wave plates in this way have resulted in very narrow usable bandwidths. In this paper, we use the Pancharatnam method to increase the usable bandwidth. A combination of Finite Element Method and Transmission Line models were used to optimise the final design. Experimental results are compared to the modelled data.
△ Less
Submitted 21 February, 2014;
originally announced February 2014.
-
Dog Bone Triplet Metamaterial Wave Plate
Authors:
Imran Mohamed,
Giampaolo Pisano,
Ming Wah Ng,
Vic Haynes,
Bruno Maffei
Abstract:
Metamaterials are artificially made sub-wavelength structures arranged in periodic arrays. They can be designed to interact with electromagnetic radiation in many different and interesting ways such as allowing radiation to experience a negative refractive index (NRI). We have used this technique to design and build a quasi-optical Half Wave Plate (HWP) that exhibits a large birefringence by virtu…
▽ More
Metamaterials are artificially made sub-wavelength structures arranged in periodic arrays. They can be designed to interact with electromagnetic radiation in many different and interesting ways such as allowing radiation to experience a negative refractive index (NRI). We have used this technique to design and build a quasi-optical Half Wave Plate (HWP) that exhibits a large birefringence by virtue of having a positive refractive index in one axis and a NRI in the other. Previous implementations of such NRI-HWP have been narrow band ($\sim$1-3%) due to the inherent reliance on needing a resonance to create the NRI region. We manufacture a W-band prototype of a novel HWP that uses the Pancharatnam method to extend the bandwidth (up to more than twice) of a usual NRI-HWP. Our simulated and experimentally obtained results despite their differences show that a broadening of a flat region of the phase difference is possible even with the initially steep gradient for a single plate.
△ Less
Submitted 15 January, 2014;
originally announced January 2014.
-
Latest Progress on the QUBIC Instrument
Authors:
A. Ghribi,
J. Aumont,
E. S. Battistelli,
A. Bau,
L. Bergé,
J-Ph. Bernard,
M. Bersanelli,
M-A. Bigot-Sazy,
G. Bordier,
E. T. Bunn,
F. Cavaliere,
P. Chanial,
A. Coppolecchia,
T. Decourcelle,
P. De Bernardis,
M. De Petris,
A-A. Drilien,
L. Dumoulin,
M. C. Falvella,
A. Gault,
M. Gervasi,
M. Giard,
M. Gradziel,
L. Grandsire,
D. Gayer
, et al. (38 additional authors not shown)
Abstract:
QUBIC is a unique instrument that crosses the barriers between classical imaging architectures and interferometry taking advantage from both for high sensitivity and systematics mitigation. The scientific target is the detection of the primordial gravitational waves imprint on the Cosmic Microwave Background which are the proof of inflation, holy grail of modern cosmology. In this paper, we show t…
▽ More
QUBIC is a unique instrument that crosses the barriers between classical imaging architectures and interferometry taking advantage from both for high sensitivity and systematics mitigation. The scientific target is the detection of the primordial gravitational waves imprint on the Cosmic Microwave Background which are the proof of inflation, holy grail of modern cosmology. In this paper, we show the latest advances in the development of the architecture and the sub-systems of the first module of this instrument to be deployed in Dome Charlie Concordia base - Antarctica in 2015.
△ Less
Submitted 12 November, 2013; v1 submitted 22 July, 2013;
originally announced July 2013.
-
SWIPE: a bolometric polarimeter for the Large-Scale Polarization Explorer
Authors:
P. de Bernardis,
S. Aiola,
G. Amico,
E. Battistelli,
A. Coppolecchia,
A. Cruciani,
A. D' Addabbo,
G. D' Alessandro,
S. De Gregori,
M. De Petris,
D. Goldie,
R. Gualtieri,
V. Haynes,
L. Lamagna,
B. Maffei,
S. Masi,
F. Nati,
M. Wah Ng,
L. Pagano,
F. Piacentini,
L. Piccirillo,
G. Pisano,
G. Romeo,
M. Salatino,
A. Schillaci
, et al. (2 additional authors not shown)
Abstract:
The balloon-borne LSPE mission is optimized to measure the linear polarization of the Cosmic Microwave Background at large angular scales. The Short Wavelength Instrument for the Polarization Explorer (SWIPE) is composed of 3 arrays of multi-mode bolometers cooled at 0.3K, with optical components and filters cryogenically cooled below 4K to reduce the background on the detectors. Polarimetry is ac…
▽ More
The balloon-borne LSPE mission is optimized to measure the linear polarization of the Cosmic Microwave Background at large angular scales. The Short Wavelength Instrument for the Polarization Explorer (SWIPE) is composed of 3 arrays of multi-mode bolometers cooled at 0.3K, with optical components and filters cryogenically cooled below 4K to reduce the background on the detectors. Polarimetry is achieved by means of large rotating half-wave plates and wire-grid polarizers in front of the arrays. The polarization modulator is the first component of the optical chain, reducing significantly the effect of instrumental polarization. In SWIPE we trade angular resolution for sensitivity. The diameter of the entrance pupil of the refractive telescope is 45 cm, while the field optics is optimized to collect tens of modes for each detector, thus boosting the absorbed power. This approach results in a FWHM resolution of 1.8, 1.5, 1.2 degrees at 95, 145, 245 GHz respectively. The expected performance of the three channels is limited by photon noise, resulting in a final sensitivity around 0.1-0.2 uK per beam, for a 13 days survey covering 25% of the sky.
△ Less
Submitted 1 August, 2012;
originally announced August 2012.
-
A Translational Polarization Rotator
Authors:
David T. Chuss,
Edward J. Wollack,
Giampaolo Pisano,
Sheridan Ackiss,
Kongpop U-Yen,
Ming wah Ng
Abstract:
We explore a free-space polarization modulator in which a variable phase introduction between right- and left-handed circular polarization components is used to rotate the linear polarization of the outgoing beam relative to that of the incoming beam. In this device, the polarization states are separated by a circular polarizer that consists of a quarter-wave plate in combination with a wire grid.…
▽ More
We explore a free-space polarization modulator in which a variable phase introduction between right- and left-handed circular polarization components is used to rotate the linear polarization of the outgoing beam relative to that of the incoming beam. In this device, the polarization states are separated by a circular polarizer that consists of a quarter-wave plate in combination with a wire grid. A movable mirror is positioned behind and parallel to the circular polarizer. As the polarizer-mirror distance is separated, an incident linear polarization will be rotated through an angle that is proportional to the introduced phase delay. We demonstrate a prototype device that modulates Stokes Q and U over a 20% bandwidth, from 77 to 94 GHz.
△ Less
Submitted 10 August, 2012; v1 submitted 11 June, 2012;
originally announced June 2012.