A High Spectral Resolution Study of the Soft X-ray Background with the X-ray Quantum Calorimeter
Authors:
Dallas Wulf,
Megan E Eckart,
Massimiliano Galeazzi,
Felix Jaeckel,
Richard L Kelley,
Caroline A Kilbourne,
Kelsey M Morgan,
Dan McCammon,
F Scott Porter,
Andrew E Szymkowiak
Abstract:
We present here a combined analysis of four high spectral resolution observations of the Diffuse X-ray Background (DXRB), made using the University of Wisconsin-Madison/Goddard Space Flight Center X-ray Quantum Calorimeter (XQC) sounding rocket payload. The observed spectra support the existence of a $\sim0.1~$keV Local Hot Bubble and a $\sim0.2~$keV Hot Halo, with discrepancies between repeated o…
▽ More
We present here a combined analysis of four high spectral resolution observations of the Diffuse X-ray Background (DXRB), made using the University of Wisconsin-Madison/Goddard Space Flight Center X-ray Quantum Calorimeter (XQC) sounding rocket payload. The observed spectra support the existence of a $\sim0.1~$keV Local Hot Bubble and a $\sim0.2~$keV Hot Halo, with discrepancies between repeated observations compatible with expected contributions of time-variable emission from Solar Wind Charge Exchange (SWCX). An additional component of $\sim0.9~$keV emission observed only at low galactic latitudes can be consistently explained by unresolved dM stars.
△ Less
Submitted 16 September, 2019;
originally announced September 2019.
When "Optimal Filtering" Isn't
Authors:
J. W. Fowler,
B. K. Alpert,
W. B. Doriese,
J. Hays-Wehle,
Y. -I. Joe,
K. M. Morgan,
G. C. O'Neil,
C. D. Reintsema,
D. R. Schmidt,
J. N. Ullom,
D. S. Swetz
Abstract:
The so-called "optimal filter" analysis of a microcalorimeter's x-ray pulses is statistically optimal only if all pulses have the same shape, regardless of energy. The shapes of pulses from a nonlinear detector can and do depend on the pulse energy, however. A pulse-fitting procedure that we call "tangent filtering" accounts for the energy dependence of the shape and should therefore achieve super…
▽ More
The so-called "optimal filter" analysis of a microcalorimeter's x-ray pulses is statistically optimal only if all pulses have the same shape, regardless of energy. The shapes of pulses from a nonlinear detector can and do depend on the pulse energy, however. A pulse-fitting procedure that we call "tangent filtering" accounts for the energy dependence of the shape and should therefore achieve superior energy resolution. We take a geometric view of the pulse-fitting problem and give expressions to predict how much the energy resolution stands to benefit from such a procedure. We also demonstrate the method with a case study of K-line fluorescence from several 3d transition metals. The method improves the resolution from 4.9 eV to 4.2 eV at the Cu K$α$ line (8.0keV).
△ Less
Submitted 23 November, 2016;
originally announced November 2016.