-
WIMP Dark Matter Search using a 3.1 tonne $\times$ year Exposure of the XENONnT Experiment
Authors:
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
D. Antón Martin,
S. R. Armbruster,
F. Arneodo,
L. Baudis,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
K. Boese,
A. Brown,
G. Bruno,
R. Budnik,
C. Cai,
C. Capelli,
J. M. R. Cardoso,
A. P. Cimental Chávez,
A. P. Colijn,
J. Conrad
, et al. (153 additional authors not shown)
Abstract:
We report on a search for weakly interacting massive particle (WIMP) dark matter (DM) via elastic DM-xenon-nucleus interactions in the XENONnT experiment. We combine datasets from the first and second science campaigns resulting in a total exposure of $3.1\;\text{tonne}\times\text{year}$. In a blind analysis of nuclear recoil events with energies above $3.8\,\mathrm{keV_{NR}}$, we find no signific…
▽ More
We report on a search for weakly interacting massive particle (WIMP) dark matter (DM) via elastic DM-xenon-nucleus interactions in the XENONnT experiment. We combine datasets from the first and second science campaigns resulting in a total exposure of $3.1\;\text{tonne}\times\text{year}$. In a blind analysis of nuclear recoil events with energies above $3.8\,\mathrm{keV_{NR}}$, we find no significant excess above background. We set new upper limits on the spin-independent WIMP-nucleon scattering cross-section for WIMP masses above $10\,\mathrm{GeV}/c^2$ with a minimum of $1.7\,\times\,10^{-47}\,\mathrm{cm^2}$ at $90\,\%$ confidence level for a WIMP mass of $30\,\mathrm{GeV}/c^2$. We achieve a best median sensitivity of $1.4\,\times\,10^{-47}\,\mathrm{cm^2}$ for a $41\,\mathrm{GeV}/c^2$ WIMP. Compared to the result from the first XENONnT science dataset, we improve our sensitivity by a factor of up to 1.8.
△ Less
Submitted 25 February, 2025;
originally announced February 2025.
-
The neutron veto of the XENONnT experiment: Results with demineralized water
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
D. Antón Martin,
F. Arneodo,
L. Baudis,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
K. Boese,
A. Brown,
G. Bruno,
R. Budnik,
C. Cai,
C. Capelli,
J. M. R. Cardoso,
A. P. Cimental Chávez,
A. P. Colijn,
J. Conrad
, et al. (145 additional authors not shown)
Abstract:
Radiogenic neutrons emitted by detector materials are one of the most challenging backgrounds for the direct search of dark matter in the form of weakly interacting massive particles (WIMPs). To mitigate this background, the XENONnT experiment is equipped with a novel gadolinium-doped water Cherenkov detector, which encloses the xenon dual-phase time projection chamber (TPC). The neutron veto (NV)…
▽ More
Radiogenic neutrons emitted by detector materials are one of the most challenging backgrounds for the direct search of dark matter in the form of weakly interacting massive particles (WIMPs). To mitigate this background, the XENONnT experiment is equipped with a novel gadolinium-doped water Cherenkov detector, which encloses the xenon dual-phase time projection chamber (TPC). The neutron veto (NV) tags neutrons via their capture on gadolinium or hydrogen, which release $γ$-rays that are subsequently detected as Cherenkov light. In this work, we present the key features and the first results of the XENONnT NV when operated with demineralized water in the initial phase of the experiment. Its efficiency for detecting neutrons is $(82\pm 1)\,\%$, the highest neutron detection efficiency achieved in a water Cherenkov detector. This enables a high efficiency of $(53\pm 3)\,\%$ for the tagging of WIMP-like neutron signals, inside a tagging time window of $250\,\mathrm{μs}$ between TPC and NV, leading to a livetime loss of $1.6\,\%$ during the first science run of XENONnT.
△ Less
Submitted 18 December, 2024; v1 submitted 6 December, 2024;
originally announced December 2024.
-
First Indication of Solar $^8$B Neutrinos via Coherent Elastic Neutrino-Nucleus Scattering with XENONnT
Authors:
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
D. Antón Martin,
F. Arneodo,
L. Baudis,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
K. Boese,
A. Brown,
G. Bruno,
R. Budnik,
C. Cai,
C. Capelli,
J. M. R. Cardoso,
A. P. Cimental Chávez,
A. P. Colijn,
J. Conrad,
J. J. Cuenca-García
, et al. (142 additional authors not shown)
Abstract:
We present the first measurement of nuclear recoils from solar $^8$B neutrinos via coherent elastic neutrino-nucleus scattering with the XENONnT dark matter experiment. The central detector of XENONnT is a low-background, two-phase time projection chamber with a 5.9 t sensitive liquid xenon target. A blind analysis with an exposure of 3.51 t$\times$yr resulted in 37 observed events above 0.5 keV,…
▽ More
We present the first measurement of nuclear recoils from solar $^8$B neutrinos via coherent elastic neutrino-nucleus scattering with the XENONnT dark matter experiment. The central detector of XENONnT is a low-background, two-phase time projection chamber with a 5.9 t sensitive liquid xenon target. A blind analysis with an exposure of 3.51 t$\times$yr resulted in 37 observed events above 0.5 keV, with ($26.4^{+1.4}_{-1.3}$) events expected from backgrounds. The background-only hypothesis is rejected with a statistical significance of 2.73 $σ$. The measured $^8$B solar neutrino flux of $(4.7_{-2.3}^{+3.6})\times 10^6 \mathrm{cm}^{-2}\mathrm{s}^{-1}$ is consistent with results from the Sudbury Neutrino Observatory. The measured neutrino flux-weighted CE$ν$NS cross section on Xe of $(1.1^{+0.8}_{-0.5})\times10^{-39} \mathrm{cm}^2$ is consistent with the Standard Model prediction. This is the first direct measurement of nuclear recoils from solar neutrinos with a dark matter detector.
△ Less
Submitted 23 November, 2024; v1 submitted 5 August, 2024;
originally announced August 2024.
-
XENONnT WIMP Search: Signal & Background Modeling and Statistical Inference
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
D. Antón Martin,
F. Arneodo,
L. Baudis,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
K. Boese,
A. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
A. P. Cimental Chávez,
A. P. Colijn,
J. Conrad,
J. J. Cuenca-García,
V. D'Andrea
, et al. (139 additional authors not shown)
Abstract:
The XENONnT experiment searches for weakly-interacting massive particle (WIMP) dark matter scattering off a xenon nucleus. In particular, XENONnT uses a dual-phase time projection chamber with a 5.9-tonne liquid xenon target, detecting both scintillation and ionization signals to reconstruct the energy, position, and type of recoil. A blind search for nuclear recoil WIMPs with an exposure of 1.1 t…
▽ More
The XENONnT experiment searches for weakly-interacting massive particle (WIMP) dark matter scattering off a xenon nucleus. In particular, XENONnT uses a dual-phase time projection chamber with a 5.9-tonne liquid xenon target, detecting both scintillation and ionization signals to reconstruct the energy, position, and type of recoil. A blind search for nuclear recoil WIMPs with an exposure of 1.1 tonne-years (4.18 t fiducial mass) yielded no signal excess over background expectations, from which competitive exclusion limits were derived on WIMP-nucleon elastic scatter cross sections, for WIMP masses ranging from 6 GeV/$c^2$ up to the TeV/$c^2$ scale. This work details the modeling and statistical methods employed in this search. By means of calibration data, we model the detector response, which is then used to derive background and signal models. The construction and validation of these models is discussed, alongside additional purely data-driven backgrounds. We also describe the statistical inference framework, including the definition of the likelihood function and the construction of confidence intervals.
△ Less
Submitted 3 June, 2025; v1 submitted 19 June, 2024;
originally announced June 2024.
-
High-energy extension of the gamma-ray band observable with an electron-tracking Compton camera
Authors:
Tomohiko Oka,
Shingo Ogio,
Mitsuru Abe,
Kenji Hamaguchi,
Tomonori Ikeda,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Kentaro Miuchi,
Yoshitaka Mizumura,
Yuta Nakamura,
Tatsuya Sawano,
Atsushi Takada,
Taito Takemura,
Toru Tanimori,
Kei Yoshikawa
Abstract:
Although the MeV gamma-ray band is a promising energy-band window in astrophysics, the current situation of MeV gamma-ray astronomy significantly lags behind those of the other energy bands in angular resolution and sensitivity. An electron-tracking Compton camera (ETCC), a next-generation MeV detector, is expected to revolutionize the situation. An ETCC tracks each Compton-recoil electron with a…
▽ More
Although the MeV gamma-ray band is a promising energy-band window in astrophysics, the current situation of MeV gamma-ray astronomy significantly lags behind those of the other energy bands in angular resolution and sensitivity. An electron-tracking Compton camera (ETCC), a next-generation MeV detector, is expected to revolutionize the situation. An ETCC tracks each Compton-recoil electron with a gaseous electron tracker and determines the incoming direction of each gamma-ray photon; thus, it has a strong background rejection power and yields a better angular resolution than classical Compton cameras. Here, we study ETCC events in which the Compton-recoil electrons do not deposit all energies to the electron tracker but escape and hit the surrounding pixel scintillator array (PSA). We developed an analysis method for this untapped class of events and applied it to laboratory and simulation data. We found that the energy spectrum obtained from the simulation agreed with that of the actual data within a factor of 1.2. We then evaluated the detector performance using the simulation data. The angular resolution for the new-class events was found to be twice as good as in the previous study at the energy range 1.0--2.0~MeV, where both analyses overlap. We also found that the total effective area is dominated by the contribution of the double-hit events above an energy of 1.5~MeV. Notably, applying this new method extends the sensitive energy range with the ETCC from 0.2--2.1 MeV in the previous studies to up to 3.5~MeV. Adjusting the PSA dynamic range should improve the sensitivity in even higher energy gamma-rays. The development of this new analysis method would pave the way for future observations by ETCC to fill the MeV-band sensitivity gap in astronomy.
△ Less
Submitted 8 March, 2024;
originally announced March 2024.
-
The XENONnT Dark Matter Experiment
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
K. Abe,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
M. Balata,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui
, et al. (170 additional authors not shown)
Abstract:
The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in…
▽ More
The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in cryostat). The experiment is expected to extend the sensitivity to WIMP dark matter by more than an order of magnitude compared to XENON1T, thanks to the larger active mass and the significantly reduced background, improved by novel systems such as a radon removal plant and a neutron veto. This article describes the XENONnT experiment and its sub-systems in detail and reports on the detector performance during the first science run.
△ Less
Submitted 13 August, 2025; v1 submitted 15 February, 2024;
originally announced February 2024.
-
Challenges for the directional dark matter direct detection
Authors:
Kentaro Miuchi
Abstract:
Directional methods have been considered to provide a solid proof for the direct detection of the dark matter. Gaseous time-projection-chambers (TPCs) are the most mature devices for directional dark matter searches although there still exist several challenges to overcome. This paper reviews the history, current challenges and future prospects of the gaseous TPCs for directional dark matter searc…
▽ More
Directional methods have been considered to provide a solid proof for the direct detection of the dark matter. Gaseous time-projection-chambers (TPCs) are the most mature devices for directional dark matter searches although there still exist several challenges to overcome. This paper reviews the history, current challenges and future prospects of the gaseous TPCs for directional dark matter searches.
△ Less
Submitted 6 March, 2024; v1 submitted 25 September, 2023;
originally announced September 2023.
-
First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment
Authors:
XENON Collaboration,
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
L. Althueser,
B. Andrieu,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
M. Bazyk,
L. Bellagamba,
R. Biondi,
A. Bismark,
E. J. Brookes,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
T. K. Bui,
C. Cai
, et al. (141 additional authors not shown)
Abstract:
We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of $5.9$ t. During the approximately 1.1 tonne-year exposure used for this search, the intrinsic $^{85}$Kr and $^{222}$Rn concentrations in the liquid targe…
▽ More
We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of $5.9$ t. During the approximately 1.1 tonne-year exposure used for this search, the intrinsic $^{85}$Kr and $^{222}$Rn concentrations in the liquid target were reduced to unprecedentedly low levels, giving an electronic recoil background rate of $(15.8\pm1.3)~\mathrm{events}/(\mathrm{t\cdot y \cdot keV})$ in the region of interest. A blind analysis of nuclear recoil events with energies between $3.3$ keV and $60.5$ keV finds no significant excess. This leads to a minimum upper limit on the spin-independent WIMP-nucleon cross section of $2.58\times 10^{-47}~\mathrm{cm}^2$ for a WIMP mass of $28~\mathrm{GeV}/c^2$ at $90\%$ confidence level. Limits for spin-dependent interactions are also provided. Both the limit and the sensitivity for the full range of WIMP masses analyzed here improve on previous results obtained with the XENON1T experiment for the same exposure.
△ Less
Submitted 5 August, 2023; v1 submitted 26 March, 2023;
originally announced March 2023.
-
ISAI: Investigating Solar Axion by Iron-57
Authors:
Tomonori Ikeda,
Toshihiro Fujii,
Takeshi Go Tsuru,
Yuki Amano,
Kazuho Kayama,
Masamune Matsuda,
Hiromu Iwasaki,
Mizuki Uenomachi,
Kentaro Miuchi,
Yoshiyuki Onuki,
Yoshizumi Inoue,
Akimichi Taketa
Abstract:
The existence of the axion is a unique solution for the strong CP problem, and the axion is one of the most promising candidates of the dark matter. Investigating Solar Axion by Iron-57 (ISAI) is being prepared as a complemented table-top experiment to confirm the solar axion scenario. Probing an X-ray emission from the nuclear transitions associated with the axion-nucleon coupling is a leading ap…
▽ More
The existence of the axion is a unique solution for the strong CP problem, and the axion is one of the most promising candidates of the dark matter. Investigating Solar Axion by Iron-57 (ISAI) is being prepared as a complemented table-top experiment to confirm the solar axion scenario. Probing an X-ray emission from the nuclear transitions associated with the axion-nucleon coupling is a leading approach. ISAI searches for the monochromatic 14.4 keV X-ray from the first excited state of 57Fe using a state-of-the-art pixelized silicon detector, dubbed XRPIX, under an extremely low-background environment. We highlight scientific objectives, experimental design and the latest status of ISAI.
△ Less
Submitted 28 December, 2022;
originally announced December 2022.
-
Directional direct detection of light dark matter up-scattered by cosmic rays from direction of the Galactic center
Authors:
Keiko I. Nagao,
Satoshi Higashino,
Tatsuhiro Naka,
Kentaro Miuchi
Abstract:
Dark matter with MeV scale mass is difficult to detect with standard direct search detectors. However, they can be searched for by considering the up-scattering of kinetic energies by cosmic rays. Because the dark matter density is higher in the central region of the Galaxy, the up-scattered dark matter will arrive at Earth from the direction of the Galactic center. Once the dark matter is detecte…
▽ More
Dark matter with MeV scale mass is difficult to detect with standard direct search detectors. However, they can be searched for by considering the up-scattering of kinetic energies by cosmic rays. Because the dark matter density is higher in the central region of the Galaxy, the up-scattered dark matter will arrive at Earth from the direction of the Galactic center. Once the dark matter is detected, we can expect to recognize this feature by directional direct detection experiments. In this study, we simulate the nuclear recoils of the up-scattered dark matter and quantitatively reveal that a large amount of this type of dark matter is arriving from the direction of the Galactic center. Also, we have shown that the characteristic signatures of the up-scattered dark matter can be verified with more than 5$σ$ confidence levels for the assumed target atoms and future upgrades to directional detectors.
△ Less
Submitted 30 July, 2023; v1 submitted 23 November, 2022;
originally announced November 2022.
-
Direct dark matter searches with the full data set of XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
N. Kato,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
Y. Suzuki,
A. Takeda,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
Y. Itow,
K. Martens,
A. Mason,
M. Yamashita,
K. Miuchi,
Y. Takeuchi,
K. B. Lee,
M. K. Lee,
Y. Fukuda,
H. Ogawa
, et al. (7 additional authors not shown)
Abstract:
Various WIMP dark matter searches using the full data set of XMASS-I, a single-phase liquid xenon detector, are reported in this paper. Stable XMASS-I data taking accumulated a total live time of 1590.9 days between November 20, 2013 and February 1, 2019 with an analysis threshold of ${\rm 1.0\,keV_{ee}}$. In the latter half of data taking a lower analysis threshold of ${\rm 0.5\,keV_{ee}}$ was al…
▽ More
Various WIMP dark matter searches using the full data set of XMASS-I, a single-phase liquid xenon detector, are reported in this paper. Stable XMASS-I data taking accumulated a total live time of 1590.9 days between November 20, 2013 and February 1, 2019 with an analysis threshold of ${\rm 1.0\,keV_{ee}}$. In the latter half of data taking a lower analysis threshold of ${\rm 0.5\,keV_{ee}}$ was also available through a new low threshold trigger. Searching for a WIMP signal in the detector's 97~kg fiducial volume yielded a limit on the WIMP-nucleon scattering cross section of ${\rm 1.4\times 10^{-44}\, cm^{2}}$ for a ${\rm 60\,GeV/c^{2}}$ WIMP at the 90$\%$ confidence level. We also searched for WIMP induced annual modulation signatures in the detector's whole target volume, containing 832~kg of liquid xenon. For nuclear recoils of a ${\rm 8\,GeV/c^{2}}$ WIMP this analysis yielded a 90\% CL cross section limit of ${\rm 2.3\times 10^{-42}\, cm^{2}}$. At a WIMP mass of ${\rm 0.5\, GeV/c^{2}}$ the Migdal effect and Bremsstrahlung signatures were evaluated and lead to 90\% CL cross section limits of ${\rm 1.4\times 10^{-35}\, cm^{2}}$ and ${\rm 1.1\times 10^{-33}\, cm^{2}}$ respectively.
△ Less
Submitted 1 September, 2023; v1 submitted 11 November, 2022;
originally announced November 2022.
-
Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model
Authors:
C. A. J. O'Hare,
D. Loomba,
K. Altenmüller,
H. Álvarez-Pol,
F. D. Amaro,
H. M. Araújo,
D. Aristizabal Sierra,
J. Asaadi,
D. Attié,
S. Aune,
C. Awe,
Y. Ayyad,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
N. F. Bell,
B. Biasuzzi,
L. J. Bignell,
C. Boehm,
I. Bolognino,
F. M. Brunbauer,
M. Caamaño,
C. Cabo,
D. Caratelli,
J. M. Carmona
, et al. (142 additional authors not shown)
Abstract:
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detect…
▽ More
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.
△ Less
Submitted 17 July, 2022; v1 submitted 11 March, 2022;
originally announced March 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Material radiopurity control in the XENONnT experiment
Authors:
E. Aprile,
K. Abe,
F. Agostini,
S. Ahmed Maouloud,
M. Alfonsi,
L. Althueser,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
D. Antón Martin,
F. Arneodo,
L. Baudis,
A. L. Baxter,
L. Bellagamba,
R. Biondi,
A. Bismark,
A. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino,
M. Clark
, et al. (128 additional authors not shown)
Abstract:
The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and $^{222}$Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove…
▽ More
The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and $^{222}$Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background ($\sim$17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected $^{222}$Rn activity concentration in XENONnT is determined to be 4.2$\,(^{+0.5}_{-0.7})\,μ$Bq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.
△ Less
Submitted 26 January, 2023; v1 submitted 10 December, 2021;
originally announced December 2021.
-
First observation of MeV gamma-ray universe with bijective imaging spectroscopy using the Electron-Tracking Compton Telescope aboard SMILE-2+
Authors:
Atsushi Takada,
Taito Takemura,
Kei Yoshikawa,
Yoshitaka Mizumura,
Tomonori Ikeda,
Yuta Nakamura,
Ken Onozaka,
Mitsuru Abe,
Kenji Hamaguchi,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Kentaro Miuchi,
Kaname Saito,
Tatsuya Sawano,
Toru Tanimori
Abstract:
MeV gamma-rays provide a unique window for the direct measurement of line emissions from radioisotopes, but observations have made little significant progress after COMPTEL/{\it CGRO}. To observe celestial objects in this band, we are developing an electron-tracking Compton camera (ETCC), which realizes both bijective imaging spectroscopy and efficient background reduction gleaned from the recoil…
▽ More
MeV gamma-rays provide a unique window for the direct measurement of line emissions from radioisotopes, but observations have made little significant progress after COMPTEL/{\it CGRO}. To observe celestial objects in this band, we are developing an electron-tracking Compton camera (ETCC), which realizes both bijective imaging spectroscopy and efficient background reduction gleaned from the recoil electron track information. The energy spectrum of the observation target can then be obtained by a simple ON-OFF method using a correctly defined point spread function on the celestial sphere. The performance of celestial object observations was validated on the second balloon SMILE-2+ installed with an ETCC having a gaseous electron tracker with a volume of 30$\times$30$\times$30 cm$^3$. Gamma-rays from the Crab nebula were detected with a significance of 4.0$σ$ in the energy range 0.15--2.1 MeV with a live time of 5.1 h, as expected before launching. Additionally, the light curve clarified an enhancement of gamma-ray events generated in the Galactic center region, indicating that a significant proportion of the final remaining events are cosmic gamma rays. Independently, the observed intensity and time variation were consistent with the pre-launch estimates except in the Galactic center region. The estimates were based on the total background of extragalactic diffuse, atmospheric, and instrumental gamma-rays after accounting for the variations in the atmospheric depth and rigidity during the level flight. The Crab results and light curve strongly support our understanding of both the detection sensitivity and the background in real observations. This work promises significant advances in MeV gamma-ray astronomy.
△ Less
Submitted 24 March, 2022; v1 submitted 30 June, 2021;
originally announced July 2021.
-
Axion search with quantum nondemolition detection of magnons
Authors:
Tomonori Ikeda,
Asuka Ito,
Kentaro Miuchi,
Jiro Soda,
Hisaya Kurashige,
Yutaka Shikano
Abstract:
The axion provides a solution for the strong CP problem and is one of the leading candidates for dark matter. This paper proposes an axion detection scheme based on quantum nondemolition detection of magnon, i.e., quanta of collective spin excitations in solid, which is expected to be excited by the axion-electron interaction predicted by the Dine-Fischer-Srednicki-Zhitnitsky (DFSZ) model. The pro…
▽ More
The axion provides a solution for the strong CP problem and is one of the leading candidates for dark matter. This paper proposes an axion detection scheme based on quantum nondemolition detection of magnon, i.e., quanta of collective spin excitations in solid, which is expected to be excited by the axion-electron interaction predicted by the Dine-Fischer-Srednicki-Zhitnitsky (DFSZ) model. The prototype detector is composed of a ferrimagnetic sphere as an electronic spin target and a superconducting qubit. Both of these are embedded inside a microwave cavity, which leads to a coherent effective interaction between the uniform magnetostatic mode in the ferrimagnetic crystal and the qubit. An upper limit for the coupling constant between an axion and an electron is obtained as $g_{aee}<2.6\times10^{-6}$ at the 95% confidence level for the axion mass of $33.117$$μ$eV $<m_{a}<33.130$$μ$eV.
△ Less
Submitted 23 May, 2022; v1 submitted 17 February, 2021;
originally announced February 2021.
-
Search for inelastic scattering of WIMP dark matter in XENON1T
Authors:
XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
S. Andaloro,
E. Angelino,
J. R. Angevaare,
V. C. Antochi,
F. Arneodo,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (116 additional authors not shown)
Abstract:
We report the results of a search for the inelastic scattering of weakly interacting massive particles (WIMPs) in the XENON1T dark matter experiment. Scattering off $^{129}$Xe is the most sensitive probe of inelastic WIMP interactions, with a signature of a 39.6 keV de-excitation photon detected simultaneously with the nuclear recoil. Using an exposure of 0.89 tonne-years, we find no evidence of i…
▽ More
We report the results of a search for the inelastic scattering of weakly interacting massive particles (WIMPs) in the XENON1T dark matter experiment. Scattering off $^{129}$Xe is the most sensitive probe of inelastic WIMP interactions, with a signature of a 39.6 keV de-excitation photon detected simultaneously with the nuclear recoil. Using an exposure of 0.89 tonne-years, we find no evidence of inelastic WIMP scattering with a significance of more than 2$σ$. A profile-likelihood ratio analysis is used to set upper limits on the cross-section of WIMP-nucleus interactions. We exclude new parameter space for WIMPs heavier than 100 GeV/c${}^2$, with the strongest upper limit of $3.3 \times 10^{-39}$ cm${}^2$ for 130 GeV/c${}^2$ WIMPs at 90\% confidence level.
△ Less
Submitted 26 February, 2021; v1 submitted 20 November, 2020;
originally announced November 2020.
-
CYGNUS: Feasibility of a nuclear recoil observatory with directional sensitivity to dark matter and neutrinos
Authors:
S. E. Vahsen,
C. A. J. O'Hare,
W. A. Lynch,
N. J. C. Spooner,
E. Baracchini,
P. Barbeau,
J. B. R. Battat,
B. Crow,
C. Deaconu,
C. Eldridge,
A. C. Ezeribe,
M. Ghrear,
D. Loomba,
K. J. Mack,
K. Miuchi,
F. M. Mouton,
N. S. Phan,
K. Scholberg,
T. N. Thorpe
Abstract:
Now that conventional weakly interacting massive particle (WIMP) dark matter searches are approaching the neutrino floor, there has been a resurgence of interest in detectors with sensitivity to nuclear recoil directions. A large-scale directional detector is attractive in that it would have sensitivity below the neutrino floor, be capable of unambiguously establishing the galactic origin of a pur…
▽ More
Now that conventional weakly interacting massive particle (WIMP) dark matter searches are approaching the neutrino floor, there has been a resurgence of interest in detectors with sensitivity to nuclear recoil directions. A large-scale directional detector is attractive in that it would have sensitivity below the neutrino floor, be capable of unambiguously establishing the galactic origin of a purported dark matter signal, and could serve a dual purpose as a neutrino observatory. We present the first detailed analysis of a 1000 m$^3$-scale detector capable of measuring a directional nuclear recoil signal at low energies. We propose a modular and multi-site observatory consisting of time projection chambers (TPCs) filled with helium and SF$_6$ at atmospheric pressure. Depending on the TPC readout technology, 10-20 helium recoils above 6 keVr or only 3-4 recoils above 20 keVr would suffice to distinguish a 10 GeV WIMP signal from the solar neutrino background. High-resolution charge readout also enables powerful electron background rejection capabilities well below 10 keV. We detail background and site requirements at the 1000 m$^3$-scale, and identify materials that require improved radiopurity. The final experiment, which we name CYGNUS-1000, will be able to observe 10-40 neutrinos from the Sun, depending on the final energy threshold. With the same exposure, the sensitivity to spin independent cross sections will extend into presently unexplored sub-10 GeV parameter space. For spin dependent interactions, already a 10 m$^3$-scale experiment could compete with upcoming generation-two detectors, but CYGNUS-1000 would improve upon this considerably. Larger volumes would bring sensitivity to neutrinos from an even wider range of sources, including galactic supernovae, nuclear reactors, and geological processes.
△ Less
Submitted 22 December, 2020; v1 submitted 28 August, 2020;
originally announced August 2020.
-
LTARS: Analog Readout Front-end ASIC for Versatile TPC-applications
Authors:
Tetsuichi Kishishita,
S. Sumomozawa,
T. Kosaka,
T. Igarashi,
K. Sakashita,
M. Shoji,
M. M. Tanaka,
T. Hasegawa,
K. Negishi,
S. Narita,
T. Nakamura,
K. Miuchi
Abstract:
We designed a versatile analog front-end chip, called LTARS, for TPC-applications, primarily targeted at dual-phase liquid Ar-TPCs for neutrino experiments and negative-ion $μ$-TPCs for directional dark matter searches. Low-noise performance and wide dynamic range are two requirements for reading out the signals induced on the TPC readout channels. One of the development objectives is to establish…
▽ More
We designed a versatile analog front-end chip, called LTARS, for TPC-applications, primarily targeted at dual-phase liquid Ar-TPCs for neutrino experiments and negative-ion $μ$-TPCs for directional dark matter searches. Low-noise performance and wide dynamic range are two requirements for reading out the signals induced on the TPC readout channels. One of the development objectives is to establish the analog processing circuits under low temperature operation, which are designed on function block basis as reusable IPs (Intellectual Properties). The newly developed ASIC was implemented in the Silterra 180~nm CMOS technology and has 16 readout channels. We carried out the performance test at room temperature and the results showed an equivalent noise charge of 2695$\pm$71~e$^-$ (rms) with a detector capacitance of 300~pF. The dynamic range was measured to be 20--100~fC in the low-gain mode and 200--1600~fC in the high-gain mode within 10\% integral nonlinearity at room temperature. We also tested the performance at the liquid-Ar temperature and found a deterioration of the noise level with a longer shaper time. Based on these results, we also discuss a unique simulation methodology for future cold-electronics development. This method can be applicable to design the electronics used at low temperature.
△ Less
Submitted 17 August, 2020;
originally announced August 2020.
-
Search for event bursts in XMASS-I associated with gravitational-wave events
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu
, et al. (12 additional authors not shown)
Abstract:
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any pa…
▽ More
We performed a search for event bursts in the XMASS-I detector associated with 11 gravitational-wave events detected during LIGO/Virgo's O1 and O2 periods. Simple and loose cuts were applied to the data collected in the full 832 kg xenon volume around the detection time of each gravitational-wave event. The data were divided into four energy regions ranging from keV to MeV. Without assuming any particular burst models, we looked for event bursts in sliding windows with various time width from 0.02 to 10 s. The search was conducted in a time window between $-$400 and $+$10,000 s from each gravitational-wave event. For the binary neutron star merger GW170817, no significant event burst was observed in the XMASS-I detector and we set 90% confidence level upper limits on neutrino fluence for the sum of all the neutrino flavors via coherent elastic neutrino-nucleus scattering. The obtained upper limit was (1.3-2.1)$\times 10^{11}$ cm$^{-2}$ under the assumption of a Fermi-Dirac spectrum with average neutrino energy of 20 MeV. The neutrino fluence limits for mono-energetic neutrinos in the energy range between 14 and 100 MeV were also calculated. Among the other 10 gravitational wave events detected as the binary black hole mergers, a burst candidate with a 3.0$σ$ significance was found at 1801.95-1803.95 s in the analysis for GW151012. However, no significant deviation from the background in the reconstructed energy and position distributions was found. Considering the additional look-elsewhere effect of analyzing the 11 GW events, the significance of finding such a burst candidate associated with any of them is 2.1$σ$.
△ Less
Submitted 30 December, 2020; v1 submitted 29 July, 2020;
originally announced July 2020.
-
Projected WIMP Sensitivity of the XENONnT Dark Matter Experiment
Authors:
The XENON collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. R. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (115 additional authors not shown)
Abstract:
XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, c…
▽ More
XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, corresponding to (1, 13) keV and (4, 50) keV for electronic and nuclear recoils, amounts to $12.3 \pm 0.6$ (keV t y)$^{-1}$ and $(2.2\pm 0.5)\times 10^{-3}$ (keV t y)$^{-1}$, respectively, in a 4 t fiducial mass. We compute unified confidence intervals using the profile construction method, in order to ensure proper coverage. With the exposure goal of 20 t$\,$y, the expected sensitivity to spin-independent WIMP-nucleon interactions reaches a cross-section of $1.4\times10^{-48}$ cm$^2$ for a 50 GeV/c$^2$ mass WIMP at 90% confidence level, more than one order of magnitude beyond the current best limit, set by XENON1T. In addition, we show that for a 50 GeV/c$^2$ WIMP with cross-sections above $2.6\times10^{-48}$ cm$^2$ ($5.0\times10^{-48}$ cm$^2$) the median XENONnT discovery significance exceeds 3$σ$ (5$σ$). The expected sensitivity to the spin-dependent WIMP coupling to neutrons (protons) reaches $2.2\times10^{-43}$ cm$^2$ ($6.0\times10^{-42}$ cm$^2$).
△ Less
Submitted 17 November, 2020; v1 submitted 17 July, 2020;
originally announced July 2020.
-
Excess Electronic Recoil Events in XENON1T
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. R. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
B. Cimmino
, et al. (114 additional authors not shown)
Abstract:
We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 t-y and an unprecedentedly low background rate of $76\pm2$ events/(t y keV) between 1 and 30 keV, the data enables sensitive searches for solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter. An excess over known backgrounds is o…
▽ More
We report results from searches for new physics with low-energy electronic recoil data recorded with the XENON1T detector. With an exposure of 0.65 t-y and an unprecedentedly low background rate of $76\pm2$ events/(t y keV) between 1 and 30 keV, the data enables sensitive searches for solar axions, an enhanced neutrino magnetic moment, and bosonic dark matter. An excess over known backgrounds is observed at low energies and most prominent between 2 and 3 keV. The solar axion model has a 3.4$σ$ significance, and a 3D 90% confidence surface is reported for axion couplings to electrons, photons, and nucleons. This surface is inscribed in the cuboid defined by $g_{ae}<3.8 \times 10^{-12}$, $g_{ae}g_{an}^{eff}<4.8\times 10^{-18}$, and $g_{ae}g_{aγ}<7.7\times10^{-22} GeV^{-1}$, and excludes either $g_{ae}=0$ or $g_{ae}g_{aγ}=g_{ae}g_{an}^{eff}=0$. The neutrino magnetic moment signal is similarly favored over background at 3.2$σ$ and a confidence interval of $μ_ν \in (1.4,2.9)\times10^{-11}μ_B$ (90% C.L.) is reported. Both results are in strong tension with stellar constraints. The excess can also be explained by $β$ decays of tritium at 3.2$σ$ with a trace amount that can neither be confirmed nor excluded with current knowledge of its production and reduction mechanisms. The significances of the solar axion and neutrino magnetic moment hypotheses are reduced to 2.0$σ$ and 0.9$σ$, respectively, if an unconstrained tritium component is included in the fitting. With respect to bosonic dark matter, the excess favors a monoenergetic peak at ($2.3\pm0.2$) keV (68% C.L.) with a 3.0$σ$ global (4.0$σ$ local) significance. We also consider the possibility that $^{37}$Ar may be present in the detector and yield a 2.82 keV peak. Contrary to tritium, the $^{37}$Ar concentration can be tightly constrained and is found to be negligible.
△ Less
Submitted 16 October, 2020; v1 submitted 17 June, 2020;
originally announced June 2020.
-
Search for exotic neutrino-electron interactions using solar neutrinos in XMASS-I
Authors:
XMASS collaboration,
K. Abe,
Y. Chen,
K. Hiraide,
K. Ichimura,
S. Imaizumi,
N. Kato,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. H. Kim,
R. Ishii,
Y. Itow,
K. Kanzawa,
K. Martens
, et al. (13 additional authors not shown)
Abstract:
We have searched for exotic neutrino-electron interactions that could be produced by a neutrino millicharge, by a neutrino magnetic moment, or by dark photons using solar neutrinos in the XMASS-I liquid xenon detector. We observed no significant signals in 711 days of data. We obtain an upper limit for neutrino millicharge of 5.4$\times$10$^{-12} e$ at 90\% confidence level assuming all three spec…
▽ More
We have searched for exotic neutrino-electron interactions that could be produced by a neutrino millicharge, by a neutrino magnetic moment, or by dark photons using solar neutrinos in the XMASS-I liquid xenon detector. We observed no significant signals in 711 days of data. We obtain an upper limit for neutrino millicharge of 5.4$\times$10$^{-12} e$ at 90\% confidence level assuming all three species of neutrino have common millicharge. We also set flavor dependent limits assuming the respective neutrino flavor is the only one carrying a millicharge, $7.3 \times 10^{-12} e$ for $ν_e$, $1.1 \times 10^{-11} e$ for $ν_μ$, and $1.1 \times 10^{-11} e$ for $ν_τ$. These limits are the most stringent yet obtained from direct measurements. We also obtain an upper limit for the neutrino magnetic moment of 1.8$\times$10$^{-10}$ Bohr magnetons. In addition, we obtain upper limits for the coupling constant of dark photons in the $U(1)_{B-L}$ model of 1.3$\times$10$^{-6}$ if the dark photon mass is 1$\times 10^{-3}$ MeV$/c^{2}$, and 8.8$\times$10$^{-5}$ if it is 10 MeV$/c^{2}$.
△ Less
Submitted 14 August, 2020; v1 submitted 24 May, 2020;
originally announced May 2020.
-
Development of a Negative Ion Micro TPC Detector with SF$_{6}$ Gas for the Directional Dark Matter Search
Authors:
T. Ikeda,
T. Shimada,
H. Ishiura,
K. D. Nakamura,
T. Nakamura,
K. Miuchi
Abstract:
A negative ion micro time projection chamber (NI$μ$TPC) was developed and its performance studied. An NI$μ$TPC is a novel technology that enables the measurement of absolute $z$ coordinates for self-triggering TPCs. This technology provides full-fiducialization analysis, which is not possible with conventional gaseous TPCs, and is useful for directional dark matter searches in terms of background…
▽ More
A negative ion micro time projection chamber (NI$μ$TPC) was developed and its performance studied. An NI$μ$TPC is a novel technology that enables the measurement of absolute $z$ coordinates for self-triggering TPCs. This technology provides full-fiducialization analysis, which is not possible with conventional gaseous TPCs, and is useful for directional dark matter searches in terms of background rejection and the improvement of the angular resolution. The developed NI$μ$TPC prototype had a detection volume of 12.8 $\times$ 25.6 $\times$ 144 mm$^{3}$. The absolute $z$ coordinate was determined with a location accuracy of 16 mm using minority carrieres of SF$_{5}^{-}$. Simultaneously, there was a successful reconstruction of the three-dimensional (3D) tracks with a spatial resolution of 130 $μ\rm{m}$. This is the first demonstration of 3D tracking with the detection of absolute $z$ coordinates, and it is an important step in improving the sensitivity of directional dark matter searches.
△ Less
Submitted 20 April, 2020;
originally announced April 2020.
-
Energy resolution and linearity of XENON1T in the MeV energy range
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (113 additional authors not shown)
Abstract:
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XEN…
▽ More
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at 1 $σ/μ$ is as low as (0.80$\pm$0.02) % in its one-ton fiducial mass, and for single-site interactions at $Q_{ββ}$. We also present a new signal correction method to rectify the saturation effects of the signal readout system, resulting in more accurate position reconstruction and indirectly improving the energy resolution. The very good result achieved in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.
△ Less
Submitted 9 September, 2020; v1 submitted 8 March, 2020;
originally announced March 2020.
-
MPGD simulation in negative-ion gas for direction-sensitive dark matter searches
Authors:
Hirohisa Ishiura,
Rob Veenhof,
Kentaro Miuchi,
Ikeda Tomonori
Abstract:
Negative-ion time projection chambers (NITPCs) provide the absolute z-position from the arrival-times' difference of several species of negative-ions. This is a strong background reduction method for rare event searches, such as direct dark mater searches. The characteristics of micro pattern gaseous detectors (MPGDs) in negative-ion gas were studied by both experiments and simulations to develop…
▽ More
Negative-ion time projection chambers (NITPCs) provide the absolute z-position from the arrival-times' difference of several species of negative-ions. This is a strong background reduction method for rare event searches, such as direct dark mater searches. The characteristics of micro pattern gaseous detectors (MPGDs) in negative-ion gas were studied by both experiments and simulations to develop an NITPC for dark matter search experiments. An MPGD simulation method for the negative-ion gas with Garfield++, which has not yet been established, was developed. We present herein the MPGD simulation results in negative-ion gas, $\mathrm{SF_{6}}$ gas, together with the experimental results, such as gain, energy resolution, and signal creation from the MPGD for future NITPC optimization.
△ Less
Submitted 30 July, 2019;
originally announced July 2019.
-
Probing GHz Gravitational Waves with Graviton-magnon Resonance
Authors:
Asuka Ito,
Tomonori Ikeda,
Kentaro Miuchi,
Jiro Soda
Abstract:
A novel method for extending frequency frontier in gravitational wave observations is proposed. It is shown that gravitational waves can excite a magnon. Thus, gravitational waves can be probed by a graviton-magnon detector which measures resonance fluorescence of magnons. Searching for gravitational waves with a wave length $λ$ by using a ferromagnetic sample with a dimension $l$, the sensitivity…
▽ More
A novel method for extending frequency frontier in gravitational wave observations is proposed. It is shown that gravitational waves can excite a magnon. Thus, gravitational waves can be probed by a graviton-magnon detector which measures resonance fluorescence of magnons. Searching for gravitational waves with a wave length $λ$ by using a ferromagnetic sample with a dimension $l$, the sensitivity of the graviton-magnon detector reaches spectral densities, around $5.4 \times 10^{-22} \times (\frac{l}{λ/2π})^{-2} \ [{\rm Hz}^{-1/2}]$ at 14 GHz and $8.6 \times 10^{-21} \times (\frac{l}{λ/2π})^{-2} \ [{\rm Hz}^{-1/2}]$ at 8.2 GHz, respectively.
△ Less
Submitted 2 March, 2020; v1 submitted 12 March, 2019;
originally announced March 2019.
-
Development of an alpha-particle imaging detector based on a low radioactivity micro-time-projection chamber
Authors:
H. Ito,
T. Hashimoto,
K. Miuchi,
K. Kobayashi,
Y. Takeuchi,
K. D. Nakamura,
T. Ikeda,
H. Ishiura
Abstract:
An important issue for rare-event-search experiments, such as the search for dark matter or neutrinoless double beta decay, is to reduce radioactivity of the detector materials and the experimental environment. The selection of materials with low radioactive impurities, such as isotopes of the uranium and thorium chains, requires a precise measurement of surface and bulk radioactivity. Focused on…
▽ More
An important issue for rare-event-search experiments, such as the search for dark matter or neutrinoless double beta decay, is to reduce radioactivity of the detector materials and the experimental environment. The selection of materials with low radioactive impurities, such as isotopes of the uranium and thorium chains, requires a precise measurement of surface and bulk radioactivity. Focused on the first one, an alpha-particle detector has been developed based on a gaseous micro-time-projection chamber. A low-alpha mu-PIC with reduced alpha-emission background was installed in the detector. The detector offers the advantage of position sensitivity, which allows the alpha-particle contamination of the sample to be imaged and the background to be measured at the same time. The detector performance was measured by using an alpha-particle source. The measurement with a sample was also demonstrated and the sensitivity is discussed.
△ Less
Submitted 30 October, 2019; v1 submitted 4 March, 2019;
originally announced March 2019.
-
Search for WIMP-$^{129}$Xe inelastic scattering with particle identification in XMASS-I
Authors:
XMASS Collaboration,
T. Suzuki,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu
, et al. (12 additional authors not shown)
Abstract:
A search for Weakly Interacting Massive Particles (WIMPs) was conducted with the single-phase liquid-xenon detector XMASS through inelastic scattering in which $^{129}$Xe nuclei were excited, using an exposure ($\rm 327\; kg \times 800.0 \; days$) 48 times larger than that of our previous study. The inelastic excitation sensitivity was improved by detailed evaluation of background, event classific…
▽ More
A search for Weakly Interacting Massive Particles (WIMPs) was conducted with the single-phase liquid-xenon detector XMASS through inelastic scattering in which $^{129}$Xe nuclei were excited, using an exposure ($\rm 327\; kg \times 800.0 \; days$) 48 times larger than that of our previous study. The inelastic excitation sensitivity was improved by detailed evaluation of background, event classification based on scintillation timing that distinguished $γ$-rays and $β$-rays, and simultaneous fitting of the energy spectra of $γ$-like and $β$-like samples. No evidence of a WIMP signal was found. Thus, we set the upper limits of the inelastic channel cross section at 90\% confidence level, for example, $4.1\times 10^{-39} \;{\rm cm^2}$ for a $200\; {\rm GeV}/c^2$ WIMP. This result provides the most stringent limits on the SD WIMP-neutron interaction and is better by a factor of 7.7 at $200\;{\rm GeV}/c^2$ than the existing experimental limit.
△ Less
Submitted 19 March, 2019; v1 submitted 14 September, 2018;
originally announced September 2018.
-
Search for sub-GeV dark matter by annual modulation using XMASS-I detector
Authors:
M. Kobayashi,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki,
B. D. Xu,
K. Miuchi
, et al. (11 additional authors not shown)
Abstract:
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in…
▽ More
A search for dark matter (DM) with mass in the sub-GeV region (0.32-1 GeV) was conducted by looking for an annual modulation signal in XMASS, a single-phase liquid xenon detector. Inelastic nuclear scattering accompanied by bremsstrahlung emission was used to search down to an electron equivalent energy of 1 keV. The data used had a live time of 2.8 years (3.5 years in calendar time), resulting in a total exposure of 2.38 ton-years. No significant modulation signal was observed and 90% confidence level upper limits of $1.6 \times 10^{-33}$ cm$^2$ at 0.5 GeV was set for the DM-nucleon cross section. This is the first experimental result of a search for DM mediated by the bremsstrahlung effect. In addition, a search for DM with mass in the multi-GeV region (4-20 GeV) was conducted with a lower energy threshold than previous analysis of XMASS. Elastic nuclear scattering was used to search down to a nuclear recoil equivalent energy of 2.3 keV, and upper limits of 2.9 $\times$10$^{-42}$ cm$^2$ at 8 GeV was obtained.
△ Less
Submitted 22 December, 2018; v1 submitted 19 August, 2018;
originally announced August 2018.
-
Development of low radioactivity photomultiplier tubes for the XMASS-I detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During dev…
▽ More
XMASS-I is a single-phase liquid xenon detector whose purpose is direct detection of dark matter. To achieve the low background requirements necessary in the detector, a new model of photomultiplier tubes (PMTs), R10789, with a hexagonal window was developed based on the R8778 PMT used in the XMASS prototype detector. We screened the numerous component materials for their radioactivity. During development, the largest contributions to the reduction of radioactivity came from the stem and the dynode support. The glass stem was exchanged to the Kovar alloy one and the ceramic support were changed to the quartz one. R10789 is the first model of Hamamatsu Photonics K. K. that adopted these materials for low background purposes and provided a groundbreaking step for further reductions of radioactivity in PMTs. Measurements with germanium detectors showed 1.2$\pm$0.3 mBq/PMT of $^{226}$Ra, less than 0.78 mBq/PMT of $^{228}$Ra, 9.1$\pm$2.2 mBq/PMT of $^{40}$K, and 2.8$\pm$0.2 mBq/PMT of $^{60}$Co. In this paper, the radioactive details of the developed R10789 are described together with our screening methods and the components of the PMT.
△ Less
Submitted 29 January, 2019; v1 submitted 10 August, 2018;
originally announced August 2018.
-
Search for dark matter in the form of hidden photons and axion-like particles in the XMASS detector
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
H. Ogawa,
K. Sato,
H. Sekiya,
T. Suzuki,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
K. Masuda,
K. Martens,
Y. Suzuki
, et al. (13 additional authors not shown)
Abstract:
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $α' / α$ parameter related to kinetic mixin…
▽ More
Hidden photons and axion-like particles are candidates for cold dark matter if they were produced non-thermally in the early universe. We conducted a search for both of these bosons using 800 live-days of data from the XMASS detector with 327 kg of liquid xenon in the fiducial volume. No significant signal was observed, and thus we set constraints on the $α' / α$ parameter related to kinetic mixing of hidden photons and the coupling constant $g_{Ae}$ of axion-like particles in the mass range from 40 to 120 keV/$c^2$, resulting in $α' / α< 6 \times 10^{-26}$ and $g_{Ae} < 4 \times 10^{-13}$. These limits are the most stringent derived from both direct and indirect searches to date.
△ Less
Submitted 18 November, 2018; v1 submitted 23 July, 2018;
originally announced July 2018.
-
A direct dark matter search in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was…
▽ More
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volume containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was ${\rm (4.2 \pm 0.2) \times 10^{-3} \, day^{-1}kg^{-1} keV_{ee}^{-1}}$ at ${\rm 5 \, keV_{ee}}$, with a signal efficiency of ${\rm 20\%}$. All the remaining events are consistent with our background evaluation, mostly of the "mis-reconstructed events" originated from $^{210}$Pb in the copper plates lining the detector's inner surface. The obtained upper limit on a spin-independent WIMP-nucleon cross section was ${\rm 2.2 \times 10^{-44} \, cm^{2}}$ for a WIMP mass of ${\rm 60 \, GeV/c^{2}}$ at the $90\%$ confidence level, which was the most stringent limit among results from single-phase liquid xenon detectors.
△ Less
Submitted 25 December, 2018; v1 submitted 6 April, 2018;
originally announced April 2018.
-
Angular dependence of columnar recombination in high pressure xenon gas using time profile of scintillation emission
Authors:
K. D. Nakamura,
S. Ban,
M. Hirose,
A. K. Ichikawa,
Y. Ishiyama,
A. Minamino,
K. Miuchi,
T. Nakaya,
H. Sekiya,
S. Tanaka,
K. Ueshima
Abstract:
The angular dependence of the columnar recombination in xenon gas, if observed for low energy nuclear tracks, can be used for a direction-sensitive dark matter search. We measured both scintillation and ionization to study columnar recombination for 5.4 MeV alpha particles in a high pressure gas detector filled with 8 atm xenon. Since the recombination photons are emitted several~$μ$s after de-exc…
▽ More
The angular dependence of the columnar recombination in xenon gas, if observed for low energy nuclear tracks, can be used for a direction-sensitive dark matter search. We measured both scintillation and ionization to study columnar recombination for 5.4 MeV alpha particles in a high pressure gas detector filled with 8 atm xenon. Since the recombination photons are emitted several~$μ$s after de-excitation emission, scintillation photons are separated to the fast and slow components. The fast component does not show dependence on the track angle relative to the drift electric field, on the other hand, the slow component increases when the track is aligned with the electric field. The result indicates that the track angle relative to the electric field can be reconstructed from the scintillation time profile.
△ Less
Submitted 4 June, 2018; v1 submitted 2 March, 2018;
originally announced March 2018.
-
Direct dark matter search by annual modulation with 2.7 years of XMASS-I data
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda,
H. Takiya
, et al. (17 additional authors not shown)
Abstract:
An annual modulation signal due to the Earth orbiting around the Sun would be one of the strongest indications of the direct detection of dark matter. In 2016, we reported a search for dark matter by looking for this annual modulation with our single-phase liquid xenon XMASS-I detector. That analysis resulted in a slightly negative modulation amplitude at low energy. In this work, we included more…
▽ More
An annual modulation signal due to the Earth orbiting around the Sun would be one of the strongest indications of the direct detection of dark matter. In 2016, we reported a search for dark matter by looking for this annual modulation with our single-phase liquid xenon XMASS-I detector. That analysis resulted in a slightly negative modulation amplitude at low energy. In this work, we included more than one year of additional data, which more than doubles the exposure to 800 live days with the same 832 kg target mass. When we assume weakly interacting massive particle (WIMP) dark matter elastically scattering on the xenon target, the exclusion upper limit for the WIMP-nucleon cross section was improved by a factor of 2 to 1.9$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ at 90\% confidence level with our newly implemented data selection through a likelihood method. For the model-independent case, without assuming any specific dark matter model, we obtained more consistency with the null hypothesis than before with a $p$-value of 0.11 in the 1$-$20 keV energy region. This search probed this region with an exposure that was larger than that of DAMA/LIBRA. We also did not find any significant amplitude in the data for periodicity with periods between 50 and 600 days in the energy region between 1 to 6 keV.
△ Less
Submitted 25 May, 2018; v1 submitted 30 January, 2018;
originally announced January 2018.
-
Study of Negative-Ion TPC Using μ-PIC for Directional Dark Matter Search
Authors:
Tomonori Ikeda,
Kentaro Miuchi,
Atsuhiko Ochi,
Ryota Yakabe,
Takashi Hashimoto,
Ryosuke Taishaku,
Daniel P. Snowden-Ifft,
Jean-Luc Gauvreau,
Toru Tanimori,
Atsushi Takada,
Kiseki Nakamura
Abstract:
Negative-ion time projection chambers(TPCs) have been studied for low-rate and high-resolution applications such as dark matter search experiments. Recently, a full volume fiducialization in a self-triggering TPC was realized. This innovative technology demonstrated a significant reduction in the background with MWPC-TPCs. We studied negative-ion TPC using the μ-PIC+GEM system and obtained suffici…
▽ More
Negative-ion time projection chambers(TPCs) have been studied for low-rate and high-resolution applications such as dark matter search experiments. Recently, a full volume fiducialization in a self-triggering TPC was realized. This innovative technology demonstrated a significant reduction in the background with MWPC-TPCs. We studied negative-ion TPC using the μ-PIC+GEM system and obtained sufficient gas gain with CS$_{2}$gas and SF$_{6}$ gas at low pressures. We expect an improvement in detector sensitivity and angular resolution with better electronics.
△ Less
Submitted 18 September, 2017;
originally announced September 2017.
-
Search for solar Kaluza-Klein axion by annual modulation with the XMASS-I detector
Authors:
XMASS Collaboration,
N. Oka,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
K. Sato,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
K. Kanzawa,
R. Kegasa,
K. Masuda
, et al. (17 additional authors not shown)
Abstract:
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits arou…
▽ More
In theories with the large extra dimensions beyond the standard 4-dimensional spacetime, axions could propagate in such extra dimensions, and acquire Kaluza-Klein (KK) excitations. These KK axions are produced in the Sun and could solve unexplained heating of the solar corona. While most of the solar KK axions escape from the solar system, a small fraction is gravitationally trapped in orbits around the Sun. They would decay into two photons inside a terrestrial detector. The event rate is expected to modulate annually depending on the distance from the Sun. We have searched for the annual modulation signature using $832\times 359$ kg$\cdot$days of XMASS-I data. No significant event rate modulation is found, and hence we set the first experimental constraint on the KK axion-photon coupling of $4.8 \times 10^{-12}\, \mathrm{GeV}^{-1}$ at 90% confidence level for a KK axion number density of $\bar{n}_\mathrm{a} = 4.07 \times 10^{13}\, \mathrm{m}^{-3}$, the total number of extra dimensions $n = 2$, and the number of extra dimensions $δ= 2$ that axions can propagate in.
△ Less
Submitted 15 November, 2017; v1 submitted 19 July, 2017;
originally announced July 2017.
-
Discrimination of anisotropy in dark matter velocity distribution with directional detectors
Authors:
Keiko I. Nagao,
Tomonori Ikeda,
Ryota Yakabe,
Tatsuhiro Naka,
Kentaro Miuchi
Abstract:
Directional detection of dark matter has sensitivity for both recoil energy and direction of nuclear recoil. It opens the way to measure local velocity distribution of dark matter. In this paper, we study possibility to discriminate isotropic distribution and anisotropic one suggested by a N-body simulation with directional detector. Numerical simulation is performed for two cases according to the…
▽ More
Directional detection of dark matter has sensitivity for both recoil energy and direction of nuclear recoil. It opens the way to measure local velocity distribution of dark matter. In this paper, we study possibility to discriminate isotropic distribution and anisotropic one suggested by a N-body simulation with directional detector. Numerical simulation is performed for two cases according to the detectors, one corresponds to angular histogram and the other is energy-angular distribution of the signals. We reveal that the anisotropy of velocity distribution can be discriminated at 90% C.L. with chi-squared test if O($10^4$) signals are obtained.
△ Less
Submitted 1 April, 2020; v1 submitted 18 July, 2017;
originally announced July 2017.
-
US Cosmic Visions: New Ideas in Dark Matter 2017: Community Report
Authors:
Marco Battaglieri,
Alberto Belloni,
Aaron Chou,
Priscilla Cushman,
Bertrand Echenard,
Rouven Essig,
Juan Estrada,
Jonathan L. Feng,
Brenna Flaugher,
Patrick J. Fox,
Peter Graham,
Carter Hall,
Roni Harnik,
JoAnne Hewett,
Joseph Incandela,
Eder Izaguirre,
Daniel McKinsey,
Matthew Pyle,
Natalie Roe,
Gray Rybka,
Pierre Sikivie,
Tim M. P. Tait,
Natalia Toro,
Richard Van De Water,
Neal Weiner
, et al. (226 additional authors not shown)
Abstract:
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
△ Less
Submitted 14 July, 2017;
originally announced July 2017.
-
Imaging Polarimeter for a Sub-MeV Gamma-Ray All-Sky Survey using an Electron-Tracking Compton Camera
Authors:
Shotaro Komura,
Atsushi Takada,
Yoshitaka Mizumura,
Shohei Miyamoto,
Taito Takemura,
Tetsuro Kishimoto,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Yuma Nakamasu,
Kiseki Nakamura,
Makoto Oda,
Joseph D. Parker,
Tatsuya Sawano,
Shinya Sonoda,
Toru Tanimori,
Dai Tomono,
Kei Yoshikawa
Abstract:
X-ray and gamma-ray polarimetry is a promising tool to study the geometry and the magnetic configuration of various celestial objects, such as binary black holes or gamma-ray bursts (GRBs). However, statistically significant polarizations have been detected in few of the brightest objects. Even though future polarimeters using X-ray telescopes are expected to observe weak persistent sources, there…
▽ More
X-ray and gamma-ray polarimetry is a promising tool to study the geometry and the magnetic configuration of various celestial objects, such as binary black holes or gamma-ray bursts (GRBs). However, statistically significant polarizations have been detected in few of the brightest objects. Even though future polarimeters using X-ray telescopes are expected to observe weak persistent sources, there are no effective approaches to survey transient and serendipitous sources with a wide field of view (FoV). Here we present an electron-tracking Compton camera (ETCC) as a highly-sensitive gamma-ray imaging polarimeter. The ETCC provides powerful background rejection and a high modulation factor over a FoV of up to 2$π$ sr thanks to its excellent imaging based on a well-defined point spread function. Importantly, we demonstrated for the first time the stability of the modulation factor under realistic conditions of off-axis incidence and huge backgrounds using the SPring-8 polarized X-ray beam. The measured modulation factor of the ETCC was 0.65 $\pm$ 0.01 at 150 keV for an off-axis incidence with an oblique angle of 30$^\circ$ and was not degraded compared to the 0.58 $\pm$ 0.02 at 130 keV for on-axis incidence. These measured results are consistent with the simulation results. Consequently, we found that the satellite-ETCC proposed in Tanimori et al. (2015) would provide all-sky surveys of weak persistent sources of 13 mCrab with 10% polarization for a 10$^{7}$ s exposure and over 20 GRBs down to a $6\times10^{-6}$ erg cm$^{-2}$ fluence and 10% polarization during a one-year observation.
△ Less
Submitted 22 March, 2017;
originally announced March 2017.
-
Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on Geometrical Optics
Authors:
Toru Tanimori,
Yoshitaka Mizumura,
Atsushi Takada,
Shohei Miyamoto,
Taito Takemura,
Tetsuro Kishimoto,
Shotaro Komura,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Yuma Nakamasu,
Kiseki Nakamura,
Joseph D. Parker,
Tatsuya Sawano,
Shinya Sonoda,
Dai Tomono,
Kei Yoshikawa
Abstract:
Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, whic…
▽ More
Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, which would be, for nuclear MeV gammas, only possible via complete reconstruction of the Compton process. Recently we have revealed that "Electron Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function (PSF). The information of an incoming gamma is kept along a ray with the PSF and that is equivalent to geometrical optics. Here we present an imaging-spectroscopic measurement with the ETCC. Our results highlight the intrinsic difficulty with CCs in performing accurate imaging, and show that the ETCC surmounts this problem. The imaging capability also helps the ETCC suppress the noise level dramatically by ~3 orders of magnitude without a shielding structure. Furthermore, full reconstruction of Compton process with the ETCC provides spectra free of Compton edges. These results mark the first proper imaging of nuclear gammas based on the genuine geometrical optics.
△ Less
Submitted 5 February, 2017;
originally announced February 2017.
-
Readout technologies for directional WIMP Dark Matter detection
Authors:
J. B. R. Battat,
I. G. Irastorza,
A. Aleksandrov,
M. Ali Guler,
T. Asada,
E. Baracchini,
J. Billard,
G. Bosson,
O. Bourrion,
J. Bouvier,
A. Buonaura,
K. Burdge,
S. Cebrian,
P. Colas,
L. Consiglio,
T. Dafni,
N. D'Ambrosio,
C. Deaconu,
G. De Lellis,
T. Descombes,
A. Di Crescenzo,
N. Di Marco,
G. Druitt,
R. Eggleston,
E. Ferrer-Ribas
, et al. (68 additional authors not shown)
Abstract:
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial…
▽ More
The measurement of the direction of WIMP-induced nuclear recoils is a compelling but technologically challenging strategy to provide an unambiguous signature of the detection of Galactic dark matter. Most directional detectors aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas or solid targets. The main challenge with directional detection is the need for high spatial resolution over large volumes, which puts strong requirements on the readout technologies. In this paper we review the various detector readout technologies used by directional detectors. In particular, we summarize the challenges, advantages and drawbacks of each approach, and discuss future prospects for these technologies.
△ Less
Submitted 6 October, 2016;
originally announced October 2016.
-
A measurement of the time profile of scintillation induced by low energy gamma-rays in liquid xenon with the XMASS-I detector
Authors:
XMASS Collaboration,
H. Takiya,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
S. Tasaka,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
Y. Itow,
R. Kegasa,
K. Kobayashi,
K. Masuda,
K. Fushimi
, et al. (15 additional authors not shown)
Abstract:
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xeno…
▽ More
We report the measurement of the emission time profile of scintillation from gamma-ray induced events in the XMASS-I 832 kg liquid xenon scintillation detector. Decay time constant was derived from a comparison of scintillation photon timing distributions between the observed data and simulated samples in order to take into account optical processes such as absorption and scattering in liquid xenon. Calibration data of radioactive sources, $^{55}$Fe, $^{241}$Am, and $^{57}$Co were used to obtain the decay time constant. Assuming two decay components, $τ_1$ and $τ_2$, the decay time constant $τ_2$ increased from 27.9 ns to 37.0 ns as the gamma-ray energy increased from 5.9 keV to 122 keV. The accuracy of the measurement was better than 1.5 ns at all energy levels. A fast decay component with $τ_1 \sim 2$ ns was necessary to reproduce data. Energy dependencies of $τ_2$ and the fraction of the fast decay component were studied as a function of the kinetic energy of electrons induced by gamma-rays. The obtained data almost reproduced previously reported results and extended them to the lower energy region relevant to direct dark matter searches.
△ Less
Submitted 18 August, 2016; v1 submitted 6 April, 2016;
originally announced April 2016.
-
Direct dark matter search by annual modulation in XMASS-I
Authors:
XMASS Collaboration,
K. Abe,
K. Hiraide,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
M. Kobayashi,
S. Moriyama,
M. Nakahata,
T. Norita,
H. Ogawa,
H. Sekiya,
O. Takachio,
A. Takeda,
M. Yamashita,
B. S. Yang,
N. Y. Kim,
Y. D. Kim,
S. Tasaka,
K. Fushimi,
J. Liu,
K. Martens,
Y. Suzuki,
B. D. Xu,
R. Fujita
, et al. (17 additional authors not shown)
Abstract:
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on t…
▽ More
A search for dark matter was conducted by looking for an annual modulation signal due to the Earth's rotation around the Sun using XMASS, a single phase liquid xenon detector. The data used for this analysis was 359.2 live days times 832 kg of exposure accumulated between November 2013 and March 2015. When we assume Weakly Interacting Massive Particle (WIMP) dark matter elastically scattering on the target nuclei, the exclusion upper limit of the WIMP-nucleon cross section 4.3$\times$10$^{-41}$cm$^2$ at 8 GeV/c$^2$ was obtained and we exclude almost all the DAMA/LIBRA allowed region in the 6 to 16 GeV/c$^2$ range at $\sim$10$^{-40}$cm$^2$. The result of a simple modulation analysis, without assuming any specific dark matter model but including electron/$γ$ events, showed a slight negative amplitude. The $p$-values obtained with two independent analyses are 0.014 and 0.068 for null hypothesis, respectively. we obtained 90\% C.L. upper bounds that can be used to test various models. This is the first extensive annual modulation search probing this region with an exposure comparable to DAMA/LIBRA.
△ Less
Submitted 25 May, 2016; v1 submitted 15 November, 2015;
originally announced November 2015.
-
New readout and data-acquisition system in an electron-tracking Compton camera for MeV gamma-ray astronomy (SMILE-II)
Authors:
Tetsuya Mizumoto,
Yoshihiro Matsuoka,
Yoshitaka Mizumura,
Toru Tanimori,
Hidetoshi Kubo,
Atsushi Takada,
Satoru Iwaki,
Tatsuya Sawano,
Kiseki Nakamura,
Shotaro Komura,
Shogo Nakamura,
Tetsuro Kishimoto,
Makoto Oda,
Shohei Miyamoto,
Taito Takemura,
Joseph D. Parker,
Dai Tomono,
Shinya Sonoda,
Kentaro Miuchi,
Shunsuke Kurosawa
Abstract:
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas detector for tracking recoil electrons and a position-sensitive scintillation camera for d…
▽ More
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas detector for tracking recoil electrons and a position-sensitive scintillation camera for detecting scattered gamma rays. After the success of a first balloon experiment in 2006 with a small ETCC (using a 10$\times$10$\times$15 cm$^3$ TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm)$^{3}$ medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II). To achieve this goal, a 100-times-larger detection area compared with that of SMILE-I is required without changing the weight or power consumption of the detector system. In addition, the event rate is also expected to dramatically increase during observation. Here, we describe both the concept and the performance of the new data-acquisition system with this (30 cm)$^{3}$ ETCC to manage 100 times more data while satisfying the severe restrictions regarding the weight and power consumption imposed by a balloon-borne observation. In particular, to improve the detection efficiency of the fine tracks in the TPC from $\sim$10\% to $\sim$100\%, we introduce a new data-handling algorithm in the TPC. Therefore, for efficient management of such large amounts of data, we developed a data-acquisition system with parallel data flow.
△ Less
Submitted 29 August, 2015; v1 submitted 5 August, 2015;
originally announced August 2015.
-
Light Dark Matter Search with SOIPIX
Authors:
Naoya Oka,
Kentaro Miuchi,
Takeshi G. Tsuru,
Ayaki Takeda,
Hideaki Matsumura
Abstract:
We propose a light dark matter search experiment using an SOI pixel detector (SOIPIX). The event-driven SOIPIX can be a powerful tool for detecting light WIMPs because of its low energy threshold (< 1 keV) and high timing resolution (few μs). In this study, we evaluate the performance of an SOIPIX prototype detector and we examine the required specifications of SOIPIX for our target sensitivity.
We propose a light dark matter search experiment using an SOI pixel detector (SOIPIX). The event-driven SOIPIX can be a powerful tool for detecting light WIMPs because of its low energy threshold (< 1 keV) and high timing resolution (few μs). In this study, we evaluate the performance of an SOIPIX prototype detector and we examine the required specifications of SOIPIX for our target sensitivity.
△ Less
Submitted 24 July, 2015;
originally announced July 2015.
-
An Electron-Tracking Compton Telescope for a Survey of the Deep Universe by MeV gamma-rays
Authors:
T. Tanimori,
H. Kubo,
A. Takada,
S. Iwaki,
S. Komura,
S. Kurosawa,
Y. Matsuoka,
K. Miuchi,
S. Miyamoto,
T. Mizumoto,
Y. Mizumura,
K. Nakamura,
S. Nakamura,
M. Oda,
J. D. Parker,
T. Sawano,
S. Sonoda,
T. Takemura,
D. Tomono,
K. Ueno
Abstract:
Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which are originated from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the directional information of the recoil electrons. The recent major mission/instrument in the MeV band, Compton Gamma Ray Observatory/COMPTEL, which was Compton C…
▽ More
Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which are originated from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the directional information of the recoil electrons. The recent major mission/instrument in the MeV band, Compton Gamma Ray Observatory/COMPTEL, which was Compton Camera (CC), detected mere $\sim30$ persistent sources. It is in stark contrast with $\sim$2000 sources in the GeV band. Here we report the performance of an Electron-Tracking Compton Camera (ETCC), and prove that it has a good potential to break through this stagnation in MeV gamma-ray astronomy. The ETCC provides all the parameters of Compton-scattering by measuring 3-D recoil electron tracks; then the Scatter Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx), which CCs cannot measure, is also obtained, and is found to be indeed helpful to reduce the background under conditions similar to space. Accordingly the significance in gamma detection is improved severalfold. On the other hand, SPD is essential to determine the point-spread function (PSF) quantitatively. The SPD resolution is improved close to the theoretical limit for multiple scattering of recoil electrons. With such a well-determined PSF, we demonstrate for the first time that it is possible to provide reliable sensitivity in Compton imaging without utilizing an optimization algorithm. As such, this study highlights the fundamental weak-points of CCs. In contrast we demonstrate the possibility of ETCC reaching the sensitivity below $1\times10^{-12}$ erg cm$^{-2}$ s$^{-1}$ at 1 MeV.
△ Less
Submitted 4 August, 2015; v1 submitted 14 July, 2015;
originally announced July 2015.
-
Performance of a new electron-tracking Compton camera under intense radiations from a water target irradiated with a proton beam
Authors:
Yoshihiro Matsuoka,
T. Tanimori,
H. Kubo,
A. Takada,
J. D. Parker,
T. Mizumoto,
Y. Mizumura,
S. Iwaki,
T. Sawano,
S. Komura,
T. Kishimoto,
M. Oda,
T. Takemura,
S. Miyamoto,
S. Sonoda,
D. Tomono,
K. Miuchi,
S. Kabuki,
S. Kurosawa
Abstract:
We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient back…
▽ More
We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient background rejection power in Compton-kinematics tests, identifies particle from the energy deposit rate (dE/dX) registered in the TPC, and provides high quality imaging by completely reconstructing the Compton scattering process. We are planning the "Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for observing the Crab nebula, are ongoing. However, observations at balloon altitudes or satellite orbits are obstructed by radiation background from the atmosphere and the detector itself. The background rejection power was checked using proton accelerator experiments conducted at the Research Center for Nuclear Physics, Osaka University. To create the intense radiation fields encountered in space, which comprise gamma rays, neutrons, protons, and other energetic entities, we irradiated a water target with a 140 MeV proton beam and placed a SMILE-II ETCC near the target. In this situation, the counting rate was five times than that expected at the balloon altitude. Nonetheless, the ETCC stably operated and identified particles sufficiently to obtain a clear gamma ray image of the checking source. Here, we report the performance of our detector and demonstrate its effective background rejection based in electron tracking experiments.
△ Less
Submitted 22 January, 2015; v1 submitted 12 December, 2014;
originally announced December 2014.
-
Search for bosonic superweakly interacting massive dark matter particles with the XMASS-I detector
Authors:
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
Y. Kishimoto,
K. Ichimura,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
O. Takachio,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa,
K. Miuchi
, et al. (20 additional authors not shown)
Abstract:
Bosonic superweakly interacting massive particles (super-WIMPs) are a candidate for warm dark matter. With the absorption of such a boson by a xenon atom these dark matter candidates would deposit an energy equivalent to their rest mass in the detector. This is the first direct detection experiment exploring the vector super-WIMPs in the mass range between 40 and 120 keV. Using 165.9 days of data…
▽ More
Bosonic superweakly interacting massive particles (super-WIMPs) are a candidate for warm dark matter. With the absorption of such a boson by a xenon atom these dark matter candidates would deposit an energy equivalent to their rest mass in the detector. This is the first direct detection experiment exploring the vector super-WIMPs in the mass range between 40 and 120 keV. Using 165.9 days of data no significant excess above background was observed in the fiducial mass of 41 kg. The present limit for the vector super-WIMPs excludes the possibility that such particles constitute all of dark matter. The absence of a signal also provides the most stringent direct constraint on the coupling constant of pseudoscalar super-WIMPs to electrons. The unprecedented sensitivity was achieved exploiting the low background at a level $10^{-4}$ kg$^{-1}$keV$_{ee}^{-1}$day$^{-1}$ in the detector.
△ Less
Submitted 21 August, 2014; v1 submitted 2 June, 2014;
originally announced June 2014.
-
Search for inelastic WIMP nucleus scattering on $^{129}$Xe in data from the XMASS-I experiment
Authors:
H. Uchida,
K. Abe,
K. Hieda,
K. Hiraide,
S. Hirano,
K. Ichimura,
Y. Kishimoto,
K. Kobayashi,
S. Moriyama,
K. Nakagawa,
M. Nakahata,
H. Ogawa,
N. Oka,
H. Sekiya,
A. Shinozaki,
Y. Suzuki,
A. Takeda,
O. Takachio,
D. Umemoto,
M. Yamashita,
B. S. Yang,
S. Tasaka,
J. Liu,
K. Martens,
K. Hosokawa
, et al. (21 additional authors not shown)
Abstract:
A search for inelastic scattering of Weakly Interacting Massive Particles (WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted volume containing 41 kg of LXe at the very center of our detector we observed no significant excess of events in 165.9 days of data. Our background reduction allowed us to…
▽ More
A search for inelastic scattering of Weakly Interacting Massive Particles (WIMPs) on the isotope $^{129}$Xe was done in data taken with the single phase liquid xenon detector XMASS at the Kamioka Observatory. Using a restricted volume containing 41 kg of LXe at the very center of our detector we observed no significant excess of events in 165.9 days of data. Our background reduction allowed us to derive our limits without explicitly subtracting the remaining events which are compatible with background expectations and derive for e.g. a 50 GeV WIMP an upper limit for its inelastic cross section on $^{129}$Xe nuclei of 3.2 pb at the 90% confidence level.
△ Less
Submitted 29 April, 2014; v1 submitted 19 January, 2014;
originally announced January 2014.