-
SIRI-2 Detection of the Gamma-ray Burst 221009A
Authors:
Lee J. Mitchell,
Justin D. Finke,
Bernard Phlips,
W. Neil Johnson,
Emily Kong
Abstract:
SIRI-2 is a collection of Strontium Iodide gamma-ray detectors sensitive at approximately 400 keV to 10 MeV, launched on the Department of Defense's STPSat-6 to geosynchronous orbit. SIRI-2 detected the gamma-ray burst (GRB) 221009A and, unlike most GRB detectors, was not saturated and did not require any pulse pile-up corrections. The energetics of this burst as measured by SIRI-2 are consistent…
▽ More
SIRI-2 is a collection of Strontium Iodide gamma-ray detectors sensitive at approximately 400 keV to 10 MeV, launched on the Department of Defense's STPSat-6 to geosynchronous orbit. SIRI-2 detected the gamma-ray burst (GRB) 221009A and, unlike most GRB detectors, was not saturated and did not require any pulse pile-up corrections. The energetics of this burst as measured by SIRI-2 are consistent with those found by other instruments, and the Band function fits to the spectra are consistent with that from the unsaturated Insight and GECAM instruments, and similar to corrected spectra from the Fermi Gamma-ray Burst Monitor, but softer than those found by Konus-Wind when that instrument was saturated. The total fluence measured with SIRI-2 was measured to be 0.140 +/- 0.002 erg cm-2, lower than other instruments, likely due to the increasing background of SIRI-2 forcing the calculation to use a smaller time interval. An extrapolation of the distributions of fluences from GRBs to the fluence of 221009A measured with SIRI-2 indicates bursts brighter than this one should occur about once every 4,000 years.
△ Less
Submitted 12 December, 2024;
originally announced December 2024.
-
Glowbug, a Low-Cost, High-Sensitivity Gamma-Ray Burst Telescope
Authors:
J. E. Grove,
C. C. Cheung,
M. Kerr,
L. J. Mitchell,
B. F. Phlips,
R. S. Woolf,
E. A. Wulf,
M. S. Briggs,
C. A. Wilson-Hodge,
D. Kocevski,
J. Perkins
Abstract:
We describe Glowbug, a gamma-ray telescope for bursts and other transients in the 30 keV to 2 MeV band. It was recently selected for funding by the NASA Astrophysics Research and Analysis program, with an expected launch in the early 2020s. Similar in concept to the Fermi Gamma Burst Monitor (GBM) and with similar sensitivity, Glowbug will join and enhance future networks of burst telescopes to in…
▽ More
We describe Glowbug, a gamma-ray telescope for bursts and other transients in the 30 keV to 2 MeV band. It was recently selected for funding by the NASA Astrophysics Research and Analysis program, with an expected launch in the early 2020s. Similar in concept to the Fermi Gamma Burst Monitor (GBM) and with similar sensitivity, Glowbug will join and enhance future networks of burst telescopes to increase sky coverage to short Gamma-Ray Bursts (SGRBs) from binary neutron star (BNS) mergers, including possible SGRBs from NS-black hole mergers. With the recent discovery of the SGRB coincident with the gravitational wave transient GW170817, we know such events occur with reasonable frequency. Expanded sky coverage in gamma rays is essential, as more detections of gravitational waves are expected with the improved sensitivity of the upgraded ground-based interferometers in the coming years.
△ Less
Submitted 24 September, 2020;
originally announced September 2020.
-
Radiation damage assessment of SensL SiPMs
Authors:
Lee J. Mitchell,
Bernard Phlips,
W. Neil Johnson,
Mary Johnson-Rambert,
Anika N. Kansky,
Richard Woolf
Abstract:
Silicon Photomultipliers (SiPMs) are quickly replacing traditional photomultiplier tubes (PMTs) as the readout of choice for gamma-ray scintillation detectors in space. While they offer substantial size, weight and power saving, they have shown to be susceptible to radiation damage. SensL SiPMs with different cell sizes were irradiated with 64 MeV protons and 8 MeV electrons. In general, results s…
▽ More
Silicon Photomultipliers (SiPMs) are quickly replacing traditional photomultiplier tubes (PMTs) as the readout of choice for gamma-ray scintillation detectors in space. While they offer substantial size, weight and power saving, they have shown to be susceptible to radiation damage. SensL SiPMs with different cell sizes were irradiated with 64 MeV protons and 8 MeV electrons. In general, results show larger cell sizes are more susceptible to radiation damage with the largest 50 um SiPMs showing the greatest increase in current as a function of dose. Current increases were observed for doses as low at ~2 rad(Si) for protons and ~20 rad(Si) for electrons. The U.S. Naval Research Laboratory's (NRL) Strontium Iodide Radiation Instrument (SIRI-1) experienced a 528 uA increase in the bias current of the on-board 2x2 SensL J-series 60035 SiPM over its one-year mission in sun-synchronous orbit. The work here focuses on the increase in bulk current observed with increasing radiation damage and was performed to better quantify this effect as a function of dose for future mission. These include the future NRL mission SIRI-2, the follow on to SIRI-1, Glowbug and the GAGG Radiation Instrument (GARI).
△ Less
Submitted 17 March, 2020;
originally announced March 2020.
-
Strontium Iodide Radiation Instrument (SIRI) -- Early On-Orbit Results
Authors:
Lee J. Mitchell,
Bernard F. Phlips,
J. Eric Grove,
Theodore Finne,
Mary Johnson-Rambert,
W. Neil Johnson
Abstract:
The Strontium Iodide Radiation Instrument (SIRI) is a single detector, gamma-ray spectrometer designed to space-qualify the new scintillation detector material europium-doped strontium iodide (SrI2:Eu) and new silicon photomultiplier (SiPM) technology. SIRI covers the energy range from 0.04-8 MeV and was launched into 600 km sun-synchronous orbit on Dec 3, 2018 onboard STPSat5 with a one-year miss…
▽ More
The Strontium Iodide Radiation Instrument (SIRI) is a single detector, gamma-ray spectrometer designed to space-qualify the new scintillation detector material europium-doped strontium iodide (SrI2:Eu) and new silicon photomultiplier (SiPM) technology. SIRI covers the energy range from 0.04-8 MeV and was launched into 600 km sun-synchronous orbit on Dec 3, 2018 onboard STPSat5 with a one-year mission to investigate the detector's response to on-orbit background radiation. The detector has an active volume of 11.6 cm3 and a photo fraction efficiency of 50% at 662 keV for gamma-rays parallel to the long axis of the crystal. Its spectroscopic resolution of 4.3% was measured by the FWHM of the characteristic Cs-137 gamma-ray line at 662 keV. Measured background rates external to the trapped particle regions are 40-50 counts per second for energies greater than 40 keV and are largely the result of short- and long-term activation products generated by transits of the SAA and the continual cosmic-ray bombardment. Rate maps determined from energy cuts of the collected spectral data show the expected contributions from the various trapped particle regions. Early spectra acquired by the instrument show the presence of at least 10 characteristic gamma-ray lines and a beta continuum generated by activation products within the detector and surrounding materials. As of April 2019, the instrument has acquired over 1000 hours of data and is expected to continue operations until the space vehicle is decommissioned in Dec. 2019. Results indicate SrI2:Eu provides a feasible alternative to traditional sodium iodide and cesium iodide scintillators, especially for missions where a factor-of-two improvement in energy resolution would represent a significant difference in scientific return. To the best of our knowledge, SIRI is the first on-orbit use of SrI2:Eu scintillator with SiPM readouts.
△ Less
Submitted 25 July, 2019;
originally announced July 2019.
-
The MERger-event Gamma-Ray (MERGR) Telescope
Authors:
L. J. Mitchell,
J. E. Grove,
B. F. Phlips,
C. C. Cheung,
M. Kerr,
R. S. Woolf,
M. S. Briggs,
J. S. Perkins
Abstract:
We describe the MERger-event Gamma-Ray (MERGR) Telescope intended for deployment by ~2021. MERGR will cover from 20 keV to 2 MeV with a wide field of view (6 sr) using nineteen gamma-ray detectors arranged on a section of a sphere. The telescope will work as a standalone system or as part of a network of sensors, to increase by ~50% the current sky coverage to detect short Gamma-Ray Burst (SGRB) c…
▽ More
We describe the MERger-event Gamma-Ray (MERGR) Telescope intended for deployment by ~2021. MERGR will cover from 20 keV to 2 MeV with a wide field of view (6 sr) using nineteen gamma-ray detectors arranged on a section of a sphere. The telescope will work as a standalone system or as part of a network of sensors, to increase by ~50% the current sky coverage to detect short Gamma-Ray Burst (SGRB) counterparts to neutron-star binary mergers within the ~200 Mpc range of gravitational wave detectors in the early 2020's. Inflight software will provide realtime burst detections with mean localization uncertainties of 6 deg for a photon fluence of 5 ph cm^-2 (the mean fluence of Fermi-GBM SGRBs) and <3 deg for the brightest ~5% of SGRBs to enable rapid multi-wavelength follow-up to identify a host galaxy and its redshift. To minimize cost and time to first light, MERGR is directly derived from demonstrators designed and built at NRL for the DoD Space Test Program (STP). We argue that the deployment of a network that provides all-sky coverage for SGRB detection is of immediate urgency to the multi-messenger astrophysics community.
△ Less
Submitted 9 November, 2017;
originally announced November 2017.