-
Ge-based Quantum Sensors for Low-Energy Physics
Authors:
D. -M. Mei,
N. Budhathoki,
S. A. Panamaldeniya,
K. -M. Dong,
S. Bhattarai,
A. Warren,
A. Prem,
S. Chhetri
Abstract:
We present \textbf{GeQuLEP} (Germanium-based Quantum Sensors for Low-Energy Physics), a conceptual design for an advanced quantum sensing platform integrating high-purity germanium (Ge) crystals with engineered phononic crystal cavities. At cryogenic temperatures, these cavities naturally host dipole-bound states, effectively forming quantum dots coupled to radio-frequency quantum point contact (R…
▽ More
We present \textbf{GeQuLEP} (Germanium-based Quantum Sensors for Low-Energy Physics), a conceptual design for an advanced quantum sensing platform integrating high-purity germanium (Ge) crystals with engineered phononic crystal cavities. At cryogenic temperatures, these cavities naturally host dipole-bound states, effectively forming quantum dots coupled to radio-frequency quantum point contact (RF-QPC) readout systems. This innovative coupling approach promises ultra-sensitive phonon-mediated charge detection through phonon-induced charge displacement. GeQuLEP is specifically designed to achieve exceptionally low detection thresholds, theoretically enabling single primary phonon sensitivity with anticipated energy depositions as low as \textbf{0.00745~eV}. This unprecedented sensitivity, if realized experimentally, would provide unique access to searches for low-mass dark matter down to the keV/$c^2$ mass range via nuclear and electronic recoils. Additionally, GeQuLEP aims to facilitate the real-time detection of solar \textit{pp} neutrinos through coherent elastic neutrino--nucleus scattering (CE$ν$NS). By combining phonon-based quantum transduction with quantum-classical hybrid readout schemes, the GeQuLEP architecture represents a scalable, contact-free phonon spectroscopy design that could significantly advance the capabilities of ultra-low-energy rare-event detection at the quantum limit.
△ Less
Submitted 2 July, 2025;
originally announced July 2025.
-
Development of Low-Threshold Detectors for Low-Mass Dark Matter Searches Using an N-Type Germanium Detector at 5.2 K
Authors:
Sanjay Bhattarai,
Dongming Mei,
Rajendra Panth,
Mathbar Raut,
Kyler Kooi,
Hao Mei,
Guojian Wang
Abstract:
We investigated charge transport in an n-type germanium detector at 5.2 K to explore new technology for enhancing low-mass dark matter detection sensitivity. Calculations of dipole and cluster dipole state binding energies and electric field-dependent trapping cross-sections are critical to developing low-threshold detectors. The detector operates in two modes: depleting at 77K before cooling, or…
▽ More
We investigated charge transport in an n-type germanium detector at 5.2 K to explore new technology for enhancing low-mass dark matter detection sensitivity. Calculations of dipole and cluster dipole state binding energies and electric field-dependent trapping cross-sections are critical to developing low-threshold detectors. The detector operates in two modes: depleting at 77K before cooling, or directly cooling to 5.2 K and applying different bias voltages. Results indicated lower binding energy of charge states in the second mode, at zero field and under an electric field, suggesting different charge states formed under different operating modes. Measured cluster dipole and dipole state binding energies at zero field were 7.884$\pm$0.644 meV and 8.369$\pm$0.748 meV, respectively, signifying high low-threshold potential for low-mass dark matter searches in the future.
△ Less
Submitted 16 February, 2023;
originally announced February 2023.
-
Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
J. Bang,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag
, et al. (72 additional authors not shown)
Abstract:
Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the light and charge responses of liquid xenon (LXe) to sub-keV nuclear recoils. Using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator, an…
▽ More
Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the light and charge responses of liquid xenon (LXe) to sub-keV nuclear recoils. Using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator, an in situ calibration was conducted on the LUX detector. We demonstrate direct measurements of light and charge yields down to 0.45 keV and 0.27 keV, respectively, both approaching single quanta production, the physical limit of LXe detectors. These results hold significant implications for the future of dual-phase xenon TPCs in detecting low-mass dark matter via nuclear recoils.
△ Less
Submitted 17 February, 2025; v1 submitted 11 October, 2022;
originally announced October 2022.
-
Fast and Flexible Analysis of Direct Dark Matter Search Data with Machine Learning
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
J. Bang,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
N. Carrara,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
J. Ernst,
A. Fan,
S. Fiorucci
, et al. (75 additional authors not shown)
Abstract:
We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture non-linear correlations betwe…
▽ More
We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture non-linear correlations between variables (such as smearing in light and charge signals due to position variation) by achieving equal performance using pulse areas with and without position-corrections applied. Its efficiency and scalability furthermore enables searching for dark matter using additional variables without significant computational burden. We demonstrate this by including a light signal pulse shape variable alongside more traditional inputs such as light and charge signal strengths. This technique can be exploited by future dark matter experiments to make use of additional information, reduce computational resources needed for signal searches and simulations, and make inclusion of physical nuisance parameters in fits tractable.
△ Less
Submitted 17 October, 2022; v1 submitted 14 January, 2022;
originally announced January 2022.
-
Constraints on Effective Field Theory Couplings Using 311.2 days of LUX Data
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
J. Bang,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag,
M. G. D. Gilchriese
, et al. (72 additional authors not shown)
Abstract:
We report here the results of an Effective Field Theory (EFT) WIMP search analysis using LUX data. We build upon previous LUX analyses by extending the search window to include nuclear recoil energies up to $\sim$180 keV$_{nr}$, requiring a reassessment of data quality cuts and background models. In order to use a binned Profile Likelihood statistical framework, the development of new analysis tec…
▽ More
We report here the results of an Effective Field Theory (EFT) WIMP search analysis using LUX data. We build upon previous LUX analyses by extending the search window to include nuclear recoil energies up to $\sim$180 keV$_{nr}$, requiring a reassessment of data quality cuts and background models. In order to use a binned Profile Likelihood statistical framework, the development of new analysis techniques to account for higher-energy backgrounds was required. With a 3.14$\times10^4$ kg$\cdot$day exposure using data collected between 2014 and 2016, we set 90\% C.L. exclusion limits on non-relativistic EFT WIMP couplings to neutrons and protons, providing the most stringent constraints on a significant fraction of the possible EFT WIMP interactions. Additionally, we report world-leading exclusion limits on inelastic EFT WIMP-nucleon recoils.
△ Less
Submitted 15 September, 2021; v1 submitted 13 February, 2021;
originally announced February 2021.
-
Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
J. Bang,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag
, et al. (73 additional authors not shown)
Abstract:
This paper presents a novel technique for mitigating electrode backgrounds that limit the sensitivity of searches for low-mass dark matter (DM) using xenon time projection chambers. In the LUX detector, signatures of low-mass DM interactions would be very low energy ($\sim$keV) scatters in the active target that ionize only a few xenon atoms and seldom produce detectable scintillation signals. In…
▽ More
This paper presents a novel technique for mitigating electrode backgrounds that limit the sensitivity of searches for low-mass dark matter (DM) using xenon time projection chambers. In the LUX detector, signatures of low-mass DM interactions would be very low energy ($\sim$keV) scatters in the active target that ionize only a few xenon atoms and seldom produce detectable scintillation signals. In this regime, extra precaution is required to reject a complex set of low-energy electron backgrounds that have long been observed in this class of detector. Noticing backgrounds from the wire grid electrodes near the top and bottom of the active target are particularly pernicious, we develop a machine learning technique based on ionization pulse shape to identify and reject these events. We demonstrate the technique can improve Poisson limits on low-mass DM interactions by a factor of $2$-$7$ with improvement depending heavily on the size of ionization signals. We use the technique on events in an effective $5$ tonne$\cdot$day exposure from LUX's 2013 science operation to place strong limits on low-mass DM particles with masses in the range $m_χ\in0.15$-$10$ GeV. This machine learning technique is expected to be useful for near-future experiments, such as LZ and XENONnT, which hope to perform low-mass DM searches with the stringent background control necessary to make a discovery.
△ Less
Submitted 18 November, 2020;
originally announced November 2020.
-
An Effective Field Theory Analysis of the First LUX Dark Matter Search
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag,
M. G. D. Gilchriese,
C. Gwilliam
, et al. (72 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6e-46 cm^2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4e4 kg*day exposure in its first sc…
▽ More
The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6e-46 cm^2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4e4 kg*day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass.
△ Less
Submitted 24 March, 2020;
originally announced March 2020.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
Extending light WIMP searches to single scintillation photons in LUX
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
L. de Viveiros,
A. Dobi
, et al. (100 additional authors not shown)
Abstract:
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its…
▽ More
We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.
△ Less
Submitted 27 December, 2019; v1 submitted 14 July, 2019;
originally announced July 2019.
-
Improved Measurements of the \b{eta}-Decay Response of Liquid Xenon with the LUX Detector
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
S. R. Fallon,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
J. Genovesi
, et al. (76 additional authors not shown)
Abstract:
We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.
We report results from an extensive set of measurements of the \b{eta}-decay response in liquid xenon.These measurements are derived from high-statistics calibration data from injected sources of both $^{3}$H and $^{14}$C in the LUX detector. The mean light-to-charge ratio is reported for 13 electric field values ranging from 43 to 491 V/cm, and for energies ranging from 1.5 to 145 keV.
△ Less
Submitted 7 June, 2019; v1 submitted 29 March, 2019;
originally announced March 2019.
-
Results of a Search for Sub-GeV Dark Matter Using 2013 LUX Data
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
T. J. R. Davison,
E. Druszkiewicz,
S. R. Fallon,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
J. Genovesi,
C. Ghag
, et al. (73 additional authors not shown)
Abstract:
The scattering of dark matter (DM) particles with sub-GeV masses off nuclei is difficult to detect using liquid xenon-based DM search instruments because the energy transfer during nuclear recoils is smaller than the typical detector threshold. However, the tree-level DM-nucleus scattering diagram can be accompanied by simultaneous emission of a Bremsstrahlung photon or a so-called "Migdal" electr…
▽ More
The scattering of dark matter (DM) particles with sub-GeV masses off nuclei is difficult to detect using liquid xenon-based DM search instruments because the energy transfer during nuclear recoils is smaller than the typical detector threshold. However, the tree-level DM-nucleus scattering diagram can be accompanied by simultaneous emission of a Bremsstrahlung photon or a so-called "Migdal" electron. These provide an electron recoil component to the experimental signature at higher energies than the corresponding nuclear recoil. The presence of this signature allows liquid xenon detectors to use both the scintillation and the ionization signals in the analysis where the nuclear recoil signal would not be otherwise visible. We report constraints on spin-independent DM-nucleon scattering for DM particles with masses of 0.4-5 GeV/c$^2$ using 1.4$\times10^4$ kg$\cdot$day of search exposure from the 2013 data from the Large Underground Xenon (LUX) experiment for four different classes of mediators. This analysis extends the reach of liquid xenon-based DM search instruments to lower DM masses than has been achieved previously.
△ Less
Submitted 16 October, 2019; v1 submitted 27 November, 2018;
originally announced November 2018.
-
Search for annual and diurnal rate modulations in the LUX experiment
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
T. J. R. Davison,
E. Druszkiewicz,
S. R. Fallon,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
J. Genovesi,
C. Ghag
, et al. (71 additional authors not shown)
Abstract:
Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calen…
▽ More
Various dark matter models predict annual and diurnal modulations of dark matter interaction rates in Earth-based experiments as a result of the Earth's motion in the halo. Observation of such features can provide generic evidence for detection of dark matter interactions. This paper reports a search for both annual and diurnal rate modulations in the LUX dark matter experiment using over 20 calendar months of data acquired between 2013 and 2016. This search focuses on electron recoil events at low energies, where leptophilic dark matter interactions are expected to occur and where the DAMA experiment has observed a strong rate modulation for over two decades. By using the innermost volume of the LUX detector and developing robust cuts and corrections, we obtained a stable event rate of 2.3$\pm$0.2~cpd/keV$_{\text{ee}}$/tonne, which is among the lowest in all dark matter experiments. No statistically significant annual modulation was observed in energy windows up to 26~keV$_{\text{ee}}$. Between 2 and 6~keV$_{\text{ee}}$, this analysis demonstrates the most sensitive annual modulation search up to date, with 9.2$σ$ tension with the DAMA/LIBRA result. We also report no observation of diurnal modulations above 0.2~cpd/keV$_{\text{ee}}$/tonne amplitude between 2 and 6~keV$_{\text{ee}}$.
△ Less
Submitted 27 September, 2018; v1 submitted 18 July, 2018;
originally announced July 2018.
-
Ultra-Low Energy Calibration of LUX Detector using $^{127}$Xe Electron Capture
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
E. Druszkiewicz,
B. N. Edwards,
S. R. Fallon,
A. Fan
, et al. (69 additional authors not shown)
Abstract:
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in sea…
▽ More
We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The sequence of gamma-ray and X-ray cascades associated with $^{127}$I de-excitations produces clearly identified 2-vertex events in the LUX detector. We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and N- (186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. The N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil $\textit{in situ}$ measurements that have been explored in liquid xenon.
△ Less
Submitted 3 September, 2017;
originally announced September 2017.
-
US Cosmic Visions: New Ideas in Dark Matter 2017: Community Report
Authors:
Marco Battaglieri,
Alberto Belloni,
Aaron Chou,
Priscilla Cushman,
Bertrand Echenard,
Rouven Essig,
Juan Estrada,
Jonathan L. Feng,
Brenna Flaugher,
Patrick J. Fox,
Peter Graham,
Carter Hall,
Roni Harnik,
JoAnne Hewett,
Joseph Incandela,
Eder Izaguirre,
Daniel McKinsey,
Matthew Pyle,
Natalie Roe,
Gray Rybka,
Pierre Sikivie,
Tim M. P. Tait,
Natalia Toro,
Richard Van De Water,
Neal Weiner
, et al. (226 additional authors not shown)
Abstract:
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
This white paper summarizes the workshop "U.S. Cosmic Visions: New Ideas in Dark Matter" held at University of Maryland on March 23-25, 2017.
△ Less
Submitted 14 July, 2017;
originally announced July 2017.
-
Limits on spin-dependent WIMP-nucleon cross section obtained from the complete LUX exposure
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
J. E. Y. Dobson,
E. Druszkiewicz
, et al. (75 additional authors not shown)
Abstract:
We present experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from the total 129.5 kg-year exposure acquired by the Large Underground Xenon experiment (LUX), operating at the Sanford Underground Research Facility in Lead, South Dakota (USA). A profile likelihood ratio analysis allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of…
▽ More
We present experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from the total 129.5 kg-year exposure acquired by the Large Underground Xenon experiment (LUX), operating at the Sanford Underground Research Facility in Lead, South Dakota (USA). A profile likelihood ratio analysis allows 90% CL upper limits to be set on the WIMP-neutron (WIMP-proton) cross section of $σ_n$ = 1.6$\times 10^{-41}$ cm$^{2}$ ($σ_p$ = 5$\times 10^{-40}$ cm$^{2}$) at 35 GeV$c^{-2}$, almost a sixfold improvement over the previous LUX spin-dependent results. The spin-dependent WIMP-neutron limit is the most sensitive constraint to date.
△ Less
Submitted 23 June, 2017; v1 submitted 9 May, 2017;
originally announced May 2017.
-
First Searches for Axions and Axion-Like Particles with the LUX Experiment
Authors:
D. S. Akerib,
S. Alsum,
C. Aquino,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
J. E. Y. Dobson,
E. Druszkiewicz
, et al. (76 additional authors not shown)
Abstract:
The first searches for axions and axion-like particles with the Large Underground Xenon (LUX) experiment are presented. Under the assumption of an axio-electric interaction in xenon, the coupling constant between axions and electrons, gAe is tested, using data collected in 2013 with an exposure totalling 95 live-days $\times$ 118 kg. A double-sided, profile likelihood ratio statistic test excludes…
▽ More
The first searches for axions and axion-like particles with the Large Underground Xenon (LUX) experiment are presented. Under the assumption of an axio-electric interaction in xenon, the coupling constant between axions and electrons, gAe is tested, using data collected in 2013 with an exposure totalling 95 live-days $\times$ 118 kg. A double-sided, profile likelihood ratio statistic test excludes gAe larger than 3.5 $\times$ 10$^{-12}$ (90% C.L.) for solar axions. Assuming the DFSZ theoretical description, the upper limit in coupling corresponds to an upper limit on axion mass of 0.12 eV/c$^{2}$, while for the KSVZ description masses above 36.6 eV/c$^{2}$ are excluded. For galactic axion-like particles, values of gAe larger than 4.2 $\times$ 10$^{-13}$ are excluded for particle masses in the range 1-16 keV/c$^{2}$. These are the most stringent constraints to date for these interactions.
△ Less
Submitted 30 June, 2017; v1 submitted 7 April, 2017;
originally announced April 2017.
-
LUX-ZEPLIN (LZ) Technical Design Report
Authors:
B. J. Mount,
S. Hans,
R. Rosero,
M. Yeh,
C. Chan,
R. J. Gaitskell,
D. Q. Huang,
J. Makkinje,
D. C. Malling,
M. Pangilinan,
C. A. Rhyne,
W. C. Taylor,
J. R. Verbus,
Y. D. Kim,
H. S. Lee,
J. Lee,
D. S. Leonard,
J. Li,
J. Belle,
A. Cottle,
W. H. Lippincott,
D. J. Markley,
T. J. Martin,
M. Sarychev,
T. E. Tope
, et al. (237 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
△ Less
Submitted 27 March, 2017;
originally announced March 2017.
-
Results from a search for dark matter in the complete LUX exposure
Authors:
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
R. Bramante,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
A. Dobi,
J. E. Y. Dobson,
E. Druszkiewicz
, et al. (76 additional authors not shown)
Abstract:
We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high…
▽ More
We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35e4 kg-day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 kg of active mass is operated at the Sanford Underground Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high WIMP masses relative to our previous results, this search yields no evidence of WIMP nuclear recoils. At a WIMP mass of 50 GeV/c^2, WIMP-nucleon spin-independent cross sections above 2.2e-46 cm^2 are excluded at the 90% confidence level. When combined with the previously reported LUX exposure, this exclusion strengthens to 1.1e-46 cm^2 at 50 GeV/c^2.
△ Less
Submitted 13 January, 2017; v1 submitted 26 August, 2016;
originally announced August 2016.
-
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
P. Brás,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison
, et al. (82 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. T…
▽ More
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota. A calibration of nuclear recoils in liquid xenon was performed $\textit{in situ}$ in the LUX detector using a collimated beam of mono-energetic 2.45 MeV neutrons produced by a deuterium-deuterium (D-D) fusion source. The nuclear recoil energy from the first neutron scatter in the TPC was reconstructed using the measured scattering angle defined by double-scatter neutron events within the active xenon volume. We measured the absolute charge ($Q_{y}$) and light ($L_{y}$) yields at an average electric field of 180 V/cm for nuclear recoil energies spanning 0.7 to 74 keV and 1.1 to 74 keV, respectively. This calibration of the nuclear recoil signal yields will permit the further refinement of liquid xenon nuclear recoil signal models and, importantly for dark matter searches, clearly demonstrates measured ionization and scintillation signals in this medium at recoil energies down to $\mathcal{O}$(1 keV).
△ Less
Submitted 26 October, 2016; v1 submitted 18 August, 2016;
originally announced August 2016.
-
Improved Limits on Scattering of Weakly Interacting Massive Particles from Reanalysis of 2013 LUX data
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
L. de Viveiros,
A. Dobi,
J. E. Y. Dobson
, et al. (77 additional authors not shown)
Abstract:
We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background…
▽ More
We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of the Large Underground Xenon dark matter experiment, including $1.4\times10^{4}\;\mathrm{kg\; day}$ of search exposure. This new analysis incorporates several advances: single-photon calibration at the scintillation wavelength, improved event-reconstruction algorithms, a revised background model including events originating on the detector walls in an enlarged fiducial volume, and new calibrations from decays of an injected tritium $β$ source and from kinematically constrained nuclear recoils down to 1.1 keV. Sensitivity, especially to low-mass WIMPs, is enhanced compared to our previous results which modeled the signal only above a 3 keV minimum energy. Under standard dark matter halo assumptions and in the mass range above 4 $\mathrm{GeV}\,c^{-2}$, these new results give the most stringent direct limits on the spin-independent WIMP-nucleon cross section. The 90% C.L. upper limit has a minimum of 0.6 zb at 33 $\mathrm{GeV}\,c^{-2}$ WIMP mass.
△ Less
Submitted 16 May, 2016; v1 submitted 10 December, 2015;
originally announced December 2015.
-
Tritium calibration of the LUX dark matter experiment
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
A. Bradley,
R. Bramante,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
A. Currie,
J. E. Cutter,
T. J. R. Davison,
L. de Viveiros,
A. Dobi,
J. E. Y. Dobson
, et al. (76 additional authors not shown)
Abstract:
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and compare the resu…
▽ More
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 V/cm and 105 V/cm and compare the results to the NEST model. We also measure the mean charge recombination fraction and its fluctuations, and we investigate the location and width of the LUX ER band. These results provide input to a re-analysis of the LUX Run3 WIMP search.
△ Less
Submitted 5 May, 2016; v1 submitted 9 December, 2015;
originally announced December 2015.
-
LUX-ZEPLIN (LZ) Conceptual Design Report
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
P. Bauer,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. I. Bolozdynya,
E. M. Boulton,
R. Bramante,
J. H. Buckley,
V. V. Bugaev,
R. Bunker,
S. Burdin,
J. K. Busenitz
, et al. (170 additional authors not shown)
Abstract:
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp…
▽ More
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.
△ Less
Submitted 23 September, 2015; v1 submitted 9 September, 2015;
originally announced September 2015.
-
Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques
Authors:
M. Akashi-Ronquest,
P. -A. Amaudruz,
M. Batygov,
B. Beltran,
M. Bodmer,
M. G. Boulay,
B. Broerman,
B. Buck,
A. Butcher,
B. Cai,
T. Caldwell,
M. Chen,
Y. Chen,
B. Cleveland,
K. Coakley,
K. Dering,
F. A. Duncan,
J. A. Formaggio,
R. Gagnon,
D. Gastler,
F. Giuliani,
M. Gold,
V. V. Golovko,
P. Gorel,
K. Graham
, et al. (57 additional authors not shown)
Abstract:
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We…
▽ More
Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.
△ Less
Submitted 12 December, 2014; v1 submitted 8 August, 2014;
originally announced August 2014.
-
Update on the MiniCLEAN Dark Matter Experiment
Authors:
K. Rielage,
M. Akashi-Ronquest,
M. Bodmer,
R. Bourque,
B. Buck,
A. Butcher,
T. Caldwell,
Y. Chen,
K. Coakley,
E. Flores,
J. A. Formaggio,
D. Gastler,
F. Giuliani,
M. Gold,
E. Grace,
J. Griego,
N. Guerrero,
V. Guiseppe,
R. Henning,
A. Hime,
S. Jaditz,
C. Kachulis,
E. Kearns,
J. Kelsey,
J. R. Klein
, et al. (21 additional authors not shown)
Abstract:
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of o…
▽ More
The direct search for dark matter is entering a period of increased sensitivity to the hypothetical Weakly Interacting Massive Particle (WIMP). One such technology that is being examined is a scintillation only noble liquid experiment, MiniCLEAN. MiniCLEAN utilizes over 500 kg of liquid cryogen to detect nuclear recoils from WIMP dark matter and serves as a demonstration for a future detector of order 50 to 100 tonnes. The liquid cryogen is interchangeable between argon and neon to study the A$^{2}$ dependence of the potential signal and examine backgrounds. MiniCLEAN utilizes a unique modular design with spherical geometry to maximize the light yield using cold photomultiplier tubes in a single-phase detector. Pulse shape discrimination techniques are used to separate nuclear recoil signals from electron recoil backgrounds. MiniCLEAN will be spiked with additional $^{39}$Ar to demonstrate the effective reach of the pulse shape discrimination capability. Assembly of the experiment is underway at SNOLAB and an update on the project is given.
△ Less
Submitted 19 March, 2014;
originally announced March 2014.
-
Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector
Authors:
D. S. Akerib,
H. M. Araujo,
X. Bai,
A. J. Bailey,
J. Balajthy,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
T. Coffey,
A. Currie,
L. de Viveiros,
A. Dobi,
J. Dobson,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci,
C. Flores
, et al. (55 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The ex…
▽ More
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is $(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$ in a 118~kg fiducial volume. The observed background rate is $(3.6\pm0.4_{\textrm{stat}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$, consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented.
△ Less
Submitted 5 March, 2014;
originally announced March 2014.
-
A Detailed Look at the First Results from the Large Underground Xenon (LUX) Dark Matter Experiment
Authors:
M. Szydagis,
D. S. Akerib,
H. M. Araujo,
X. Bai,
A. J. Bailey,
J. Balajthy,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
T. Coffey,
A. Currie,
L. de Viveiros,
A. Dobi,
J. Dobson,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci
, et al. (55 additional authors not shown)
Abstract:
LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive direct dark matter search experiment. The initial null-result limit on the spin-independent WIMP-nucleon scattering cross-section was released in October 2013, with a primary scintillation threshold of 2 phe, roughly 3 keV…
▽ More
LUX, the world's largest dual-phase xenon time-projection chamber, with a fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is currently the most sensitive direct dark matter search experiment. The initial null-result limit on the spin-independent WIMP-nucleon scattering cross-section was released in October 2013, with a primary scintillation threshold of 2 phe, roughly 3 keVnr for LUX. The detector has been deployed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, and is the first experiment to achieve a limit on the WIMP cross-section lower than $10^{-45}$ cm$^{2}$. Here we present a more in-depth discussion of the novel energy scale employed to better understand the nuclear recoil light and charge yields, and of the calibration sources, including the new internal tritium source. We found the LUX data to be in conflict with low-mass WIMP signal interpretations of other results.
△ Less
Submitted 25 February, 2014; v1 submitted 15 February, 2014;
originally announced February 2014.
-
First results from the LUX dark matter experiment at the Sanford Underground Research Facility
Authors:
LUX Collaboration,
D. S. Akerib,
H. M. Araujo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bolozdynya,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
C. Chan,
J. J. Chapman,
A. A. Chiller,
C. Chiller,
K. Clark,
T. Coffey,
A. Currie,
A. Curioni,
S. Dazeley,
L. de Viveiros,
A. Dobi
, et al. (78 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-li…
▽ More
The Large Underground Xenon (LUX) experiment, a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota), was cooled and filled in February 2013. We report results of the first WIMP search dataset, taken during the period April to August 2013, presenting the analysis of 85.3 live-days of data with a fiducial volume of 118 kg. A profile-likelihood analysis technique shows our data to be consistent with the background-only hypothesis, allowing 90% confidence limits to be set on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33 GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass WIMP signal interpretations of the results from several recent direct detection experiments.
△ Less
Submitted 5 February, 2014; v1 submitted 30 October, 2013;
originally announced October 2013.
-
Technical Results from the Surface Run of the LUX Dark Matter Experiment
Authors:
LUX Collaboration,
D. S. Akerib,
X. Bai,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
J. J. Chapman,
T. Coffey,
A. Dobi,
E. Dragowsky,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
M. Gilchriese,
C. Hall,
M. Hanhardt,
M. Ihm,
R. G. Jacobsen,
L. Kastens
, et al. (42 additional authors not shown)
Abstract:
We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed i…
▽ More
We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed in a water tank, validated the integration of the various sub-systems in preparation of the underground deployment. Using the data collected, we report excellent light collection properties, achieving 8.4 photoelectrons per keV for 662 keV electron recoils without an applied electric field, measured in the center of the WIMP target. We also find good energy and position resolution in relatively high-energy interactions from a variety of internal and external sources. Finally, we have used the commissioning data to tune the optical properties of our simulation and report updated sensitivity projections for spin-independent WIMP-nucleon scattering.
△ Less
Submitted 22 February, 2013; v1 submitted 16 October, 2012;
originally announced October 2012.
-
The LUX Prototype Detector: Heat Exchanger Development
Authors:
D. S. Akerib,
X. Bai,
S. Bedikian,
A. Bernstein,
A. Bolozdynya,
A. Bradley,
S. Cahn,
D. Carr,
J. J. Chapman,
K. Clark,
T. Classen,
A. Curioni,
C. E. Dahl,
S. Dazeley,
L. deViveiros,
M. Dragowsky,
E. Druszkiewicz,
S. Fiorucci,
R. J. Gaitskell,
C. Hall,
C. Faham,
B. Holbrook,
L. Kastens,
K. Kazkaz,
J. Kwong
, et al. (25 additional authors not shown)
Abstract:
The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large ($>$1ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for ac…
▽ More
The LUX (Large Underground Xenon) detector is a two-phase xenon Time Projection Chamber (TPC) designed to search for WIMP-nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large ($>$1ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for achieving robust discrimination of signal from background events. In this paper we describe the development of a novel purification system deployed in a prototype detector. The results from the operation of this prototype indicated heat exchange with an efficiency above 94% up to a flow rate of 42 slpm, allowing for an electron drift length greater than 1 meter to be achieved in approximately two days and sustained for the duration of the testing period.
△ Less
Submitted 20 January, 2013; v1 submitted 16 July, 2012;
originally announced July 2012.
-
An Ultra-Low Background PMT for Liquid Xenon Detectors
Authors:
D. S. Akerib,
X. Bai,
E. Bernard,
A. Bernstein,
A. Bradley,
D. Byram,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
Y-D. Chan,
K. Clark,
T. Coffey,
L. deViveiros,
M. Dragowsky,
E. Druszkiewicz,
B. Edwards,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
C. Hall,
M. Hanhardt,
B. Holbrook,
M. Ihm
, et al. (42 additional authors not shown)
Abstract:
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other det…
▽ More
Results are presented from radioactivity screening of two models of photomultiplier tubes designed for use in current and future liquid xenon experiments. The Hamamatsu 5.6 cm diameter R8778 PMT, used in the LUX dark matter experiment, has yielded a positive detection of four common radioactive isotopes: 238U, 232Th, 40K, and 60Co. Screening of LUX materials has rendered backgrounds from other detector materials subdominant to the R8778 contribution. A prototype Hamamatsu 7.6 cm diameter R11410 MOD PMT has also been screened, with benchmark isotope counts measured at <0.4 238U / <0.3 232Th / <8.3 40K / 2.0+-0.2 60Co mBq/PMT. This represents a large reduction, equal to a change of \times 1/24 238U / \times 1/9 232Th / \times 1/8 40K per PMT, between R8778 and R11410 MOD, concurrent with a doubling of the photocathode surface area (4.5 cm to 6.4 cm diameter). 60Co measurements are comparable between the PMTs, but can be significantly reduced in future R11410 MOD units through further material selection. Assuming PMT activity equal to the measured 90% upper limits, Monte Carlo estimates indicate that replacement of R8778 PMTs with R11410 MOD PMTs will change LUX PMT electron recoil background contributions by a factor of \times1/25 after further material selection for 60Co reduction, and nuclear recoil backgrounds by a factor of \times 1/36. The strong reduction in backgrounds below the measured R8778 levels makes the R11410 MOD a very competitive technology for use in large-scale liquid xenon detectors.
△ Less
Submitted 24 June, 2013; v1 submitted 10 May, 2012;
originally announced May 2012.
-
Germanium Detector Response to Nuclear Recoils in Searching for Dark Matter
Authors:
D. Barker,
D. -M. Mei
Abstract:
The discrepancies in claims of experimental evidence in the search for weakly interacting massive particle (WIMP) dark matter necessitate a model for ionization efficiency (the quenching factor) at energies below 10 keV. We have carefully studied the physics processes that contribute to the ionization efficiency through stopping power. The focus of this work is the construction of a model for the…
▽ More
The discrepancies in claims of experimental evidence in the search for weakly interacting massive particle (WIMP) dark matter necessitate a model for ionization efficiency (the quenching factor) at energies below 10 keV. We have carefully studied the physics processes that contribute to the ionization efficiency through stopping power. The focus of this work is the construction of a model for the ionization efficiency in germanium by analyzing the components of stopping power, specifically that of the nuclear stopping power, at low energies. We find a fraction of the ZBL nuclear stopping power can contribute to ionization efficiency. We propose a model that corrects the missing contribution to ionization efficiency from the ZBL nuclear stopping power. The proposed model is compared to previous measurements of ionization efficiency in germanium as well as that of other theoretical models. Using this new model, the thresholds of both CDMS II and CoGeNT are analyzed and compared in terms of the nuclear recoil energy.
△ Less
Submitted 22 August, 2012; v1 submitted 20 March, 2012;
originally announced March 2012.
-
After LUX: The LZ Program
Authors:
D. C. Malling,
D. S. Akerib,
H. M. Araujo,
X. Bai,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bradley,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
K. Clark,
T. Classen,
T. Coffey,
A. Curioni,
A. Currie,
S. Dazeley,
L. de Viveiros,
M. Dragowsky,
E. Druszkiewicz,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson
, et al. (49 additional authors not shown)
Abstract:
The LZ program consists of two stages of direct dark matter searches using liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the last stage will be a 20 tonne detector. Both devices will benefit tremendously from research and development performed for the LUX experiment, a 350 kg liquid Xe dark matter detector currently operating at the Sanford Underground Laboratory. In p…
▽ More
The LZ program consists of two stages of direct dark matter searches using liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the last stage will be a 20 tonne detector. Both devices will benefit tremendously from research and development performed for the LUX experiment, a 350 kg liquid Xe dark matter detector currently operating at the Sanford Underground Laboratory. In particular, the technology used for cryogenics and electrical feedthroughs, circulation and purification, low-background materials and shielding techniques, electronics, calibrations, and automated control and recovery systems are all directly scalable from LUX to the LZ detectors. Extensive searches for potential background sources have been performed, with an emphasis on previously undiscovered background sources that may have a significant impact on tonne-scale detectors. The LZ detectors will probe spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV WIMPs, which represents the ultimate limit for dark matter detection with liquid xenon technology.
△ Less
Submitted 13 October, 2011; v1 submitted 1 October, 2011;
originally announced October 2011.
-
Data Acquisition and Readout System for the LUX Dark Matter Experiment
Authors:
D. S. Akerib,
X. Bai,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bradley,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
K. Clark,
T. Classen,
T. Coffey,
A. Curioni,
S. Dazeley,
L. deViveiros,
M. Dragowsky,
E. Druszkiewicz,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
C. Hall,
M. Hanhardt,
B. Holbrook
, et al. (38 additional authors not shown)
Abstract:
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX exper…
▽ More
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX experiment. Data acquisition systems in rare-event searches must accommodate high rate and large dynamic range during precision calibrations involving radioactive sources, while also delivering low threshold for maximum sensitivity. The LUX DAQ meets these challenges using real-time baseline sup- pression that allows for a maximum event acquisition rate in excess of 1.5 kHz with virtually no deadtime. This paper describes the LUX DAQ and the novel acquisition techniques employed in the LUX experiment.
△ Less
Submitted 9 August, 2011; v1 submitted 8 August, 2011;
originally announced August 2011.
-
Fluorescence Efficiency and Visible Re-emission Spectrum of Tetraphenyl Butadiene Films at Extreme Ultraviolet Wavelengths
Authors:
V. M. Gehman,
S. R. Seibert,
K. Rielage,
A. Hime,
Y. Sun,
D. -M. Mei,
J. Maassen,
D. Moore
Abstract:
A large number of current and future experiments in neutrino and dark matter detection use the scintillation light from noble elements as a mechanism for measuring energy deposition. The scintillation light from these elements is produced in the extreme ultraviolet (EUV) range, from 60 - 200 nm. Currently, the most practical technique for observing light at these wavelengths is to surround the sci…
▽ More
A large number of current and future experiments in neutrino and dark matter detection use the scintillation light from noble elements as a mechanism for measuring energy deposition. The scintillation light from these elements is produced in the extreme ultraviolet (EUV) range, from 60 - 200 nm. Currently, the most practical technique for observing light at these wavelengths is to surround the scintillation volume with a thin film of Tetraphenyl Butadiene (TPB) to act as a fluor. The TPB film absorbs EUV photons and reemits visible photons, detectable with a variety of commercial photosensors. Here we present a measurement of the re-emission spectrum of TPB films when illuminated with 128, 160, 175, and 250 nm light. We also measure the fluorescence efficiency as a function of incident wavelength from 120 to 250 nm.
△ Less
Submitted 21 September, 2011; v1 submitted 16 April, 2011;
originally announced April 2011.
-
Status of the LUX Dark Matter Search
Authors:
S. Fiorucci,
D. S. Akerib,
S. Bedikian,
A. Bernstein,
A. Bolozdynya,
A. Bradley,
D. Carr,
J. Chapman,
K. Clark,
T. Classen,
A. Curioni,
E. Dahl,
S. Dazeley,
L. de Viveiros,
E. Druszkiewicz,
R. Gaitskell,
C. Hall,
C. Hernandez Faham,
B. Holbrook,
L. Kastens,
K. Kazkaz,
R. Lander,
K. Lesko,
D. Malling,
R. Mannino
, et al. (22 additional authors not shown)
Abstract:
The Large Underground Xenon (LUX) dark matter search experiment is currently being deployed at the Homestake Laboratory in South Dakota. We will highlight the main elements of design which make the experiment a very strong competitor in the field of direct detection, as well as an easily scalable concept. We will also present its potential reach for supersymmetric dark matter detection, within v…
▽ More
The Large Underground Xenon (LUX) dark matter search experiment is currently being deployed at the Homestake Laboratory in South Dakota. We will highlight the main elements of design which make the experiment a very strong competitor in the field of direct detection, as well as an easily scalable concept. We will also present its potential reach for supersymmetric dark matter detection, within various timeframes ranging from 1 year to 5 years or more.
△ Less
Submitted 2 December, 2009;
originally announced December 2009.
-
Cosmogenic Production as a Background in Searching for Rare Physics Processes
Authors:
D. -M. Mei,
Z. -B. Yin,
S. R. Elliott
Abstract:
We revisit calculations of the cosmogenic production rates for several long-lived isotopes that are potential sources of background in searching for rare physics processes such as the detection of dark matter and neutrinoless double-beta decay. Using updated cosmic-ray neutron flux measurements, we use TALYS 1.0 to investigate the cosmogenic activation of stable isotopes of several detector targ…
▽ More
We revisit calculations of the cosmogenic production rates for several long-lived isotopes that are potential sources of background in searching for rare physics processes such as the detection of dark matter and neutrinoless double-beta decay. Using updated cosmic-ray neutron flux measurements, we use TALYS 1.0 to investigate the cosmogenic activation of stable isotopes of several detector targets and find that the cosmogenic isotopes produced inside the target materials and cryostat can result in large backgrounds for dark matter searches and neutrinoless double-beta decay. We use previously published low-background HPGe data to constrain the production of $^{3}H$ on the surface and the upper limit is consistent with our calculation. We note that cosmogenic production of several isotopes in various targets can generate potential backgrounds for dark matter detection and neutrinoless double-beta decay with a massive detector, thus great care should be taken to limit and/or deal with the cosmogenic activation of the targets.
△ Less
Submitted 12 March, 2009;
originally announced March 2009.
-
Evaluation of (alpha,n) Induced Neutrons as a Background for Dark Matter Experiments
Authors:
D. -M. Mei,
C. Zhang,
A. Hime
Abstract:
Neutrons from ($α$,n) reactions through thorium and uranium decays are important sources of background for direct dark matter detection. The neutron yields and energy spectra from a range of materials that are used to build dark matter detectors are calculated and tabulated. In addition to thorium and uranium decays, we found that $α$ particles from samarium, often the dopant of the window mater…
▽ More
Neutrons from ($α$,n) reactions through thorium and uranium decays are important sources of background for direct dark matter detection. The neutron yields and energy spectra from a range of materials that are used to build dark matter detectors are calculated and tabulated. In addition to thorium and uranium decays, we found that $α$ particles from samarium, often the dopant of the window materials of photomultiplier tubes (PMT), are also an important source of neutron yield. The results in this paper can be used as the input to Monte Carlo simulations for many materials that will be used for next generation experiments.
△ Less
Submitted 10 March, 2009; v1 submitted 22 December, 2008;
originally announced December 2008.
-
A Model of Nuclear Recoil Scintillation Efficiency in Noble Liquids
Authors:
D. -M. Mei,
Z. -B. Yin,
L. C. Stonehill,
A. Hime
Abstract:
Scintillation efficiency of low-energy nuclear recoils in noble liquids plays a crucial role in interpreting results from some direct searches for Weakly Interacting Massive Particle (WIMP) dark matter. However, the cause of a reduced scintillation efficiency relative to electronic recoils in noble liquids remains unclear at the moment. We attribute such a reduction of scintillation efficiency t…
▽ More
Scintillation efficiency of low-energy nuclear recoils in noble liquids plays a crucial role in interpreting results from some direct searches for Weakly Interacting Massive Particle (WIMP) dark matter. However, the cause of a reduced scintillation efficiency relative to electronic recoils in noble liquids remains unclear at the moment. We attribute such a reduction of scintillation efficiency to two major mechanisms: 1) energy loss and 2) scintillation quenching. The former is commonly described by Lindhard's theory and the latter by Birk's saturation law. We propose to combine these two to explain the observed reduction of scintillation yield for nuclear recoils in noble liquids. Birk's constants $kB$ for argon, neon and xenon determined from existing data are used to predict noble liquid scintillator's response to low-energy nuclear recoils and low-energy electrons. We find that energy loss due to nuclear stopping power that contributes little to ionization and excitation is the dominant reduction mechanism in scintillation efficiency for nuclear recoils, but that significant additional quenching results from the nonlinear response of scintillation to the ionization density.
△ Less
Submitted 11 March, 2008; v1 submitted 14 December, 2007;
originally announced December 2007.
-
Deep Underground Science and Engineering Lab: S1 Dark Matter Working Group
Authors:
D. S. Akerib,
E. Aprile,
E. A. Baltz,
M. R. Dragowsky,
R. J. Gaitskell,
P. Gondolo,
A. Hime,
C. J. Martoff,
D. -M. Mei,
H. Nelson,
B. Sadoulet,
R. W. Schnee,
A. H. Sonnenschein,
L. E. Strigari
Abstract:
A study of the current status of WIMP dark matter searches has been made in the context of scientific and technical planning for a Deep Underground Science and Engineering Laboratory (DUSEL) in the U.S. The table of contents follows:
1. Overview
2. WIMP Dark Matter: Cosmology, Astrophysics, and Particle Physics
3. Direct Detection of WIMPs
4. Indirect Detection of WIMPs
5. Dark Matter…
▽ More
A study of the current status of WIMP dark matter searches has been made in the context of scientific and technical planning for a Deep Underground Science and Engineering Laboratory (DUSEL) in the U.S. The table of contents follows:
1. Overview
2. WIMP Dark Matter: Cosmology, Astrophysics, and Particle Physics
3. Direct Detection of WIMPs
4. Indirect Detection of WIMPs
5. Dark Matter Candidates and New Physics in the Laboratory
6. Synergies with Other Sub-Fields
7. Direct Detection Experiments: Status and Future Prospects
8. Infrastructure
9. International Context
10. Summary and Outlook
11. Acknowledgments
△ Less
Submitted 23 April, 2007; v1 submitted 30 May, 2006;
originally announced May 2006.
-
Muon-Induced Background Study for Underground Laboratories
Authors:
D. -M. Mei,
A. Hime
Abstract:
We provide a comprehensive study of the cosmic-ray muon flux and induced activity as a function of overburden along with a convenient parameterization of the salient fluxes and differential distributions for a suite of underground laboratories ranging in depth from $\sim$1 to 8 km.w.e.. Particular attention is given to the muon-induced fast neutron activity for the underground sites and we devel…
▽ More
We provide a comprehensive study of the cosmic-ray muon flux and induced activity as a function of overburden along with a convenient parameterization of the salient fluxes and differential distributions for a suite of underground laboratories ranging in depth from $\sim$1 to 8 km.w.e.. Particular attention is given to the muon-induced fast neutron activity for the underground sites and we develop a Depth-Sensitivity-Relation to characterize the effect of such background in experiments searching for WIMP dark matter and neutrinoless double beta decay.
△ Less
Submitted 6 December, 2005; v1 submitted 5 December, 2005;
originally announced December 2005.
-
The Supermassive Black Hole in the Gamma-ray Loud Blazar PKS 1510-089
Authors:
B. Z. Dai,
G. Z. Xie,
Z. J. Jiang,
D. C. Mei
Abstract:
We present the optical light curve for the gamma-ray blazar PKS 1510-089 with a significant variability of 2.0 mag within about 41 minutes in the R band which is the most violently rapid variability detected in our optical monitoring campaign operating since 1982. In the framework of the relativistic beaming model, the central supermassive black hole mass of PKS 1510-089 is of…
▽ More
We present the optical light curve for the gamma-ray blazar PKS 1510-089 with a significant variability of 2.0 mag within about 41 minutes in the R band which is the most violently rapid variability detected in our optical monitoring campaign operating since 1982. In the framework of the relativistic beaming model, the central supermassive black hole mass of PKS 1510-089 is of $(1.16-1.98)\times10^8M_\odot$. This is larger than some previous estimates for the central mass in blazars that have been based on models for nonthermal emission, but is consistent with the estimated result of the $M_\bullet-σ_\star$ correlation. Some other physical parameters, including the emission region size, Doppler factor $δ$, the efficiency $η$ for conversion of accreted matter into energy and luminosity are calculated. The value of $η$ = 62.2 strongly implies that the relativistic beaming is responsible for the rapid variability of the gamma-ray loud blazar PKS 1510-089.
△ Less
Submitted 22 June, 2002; v1 submitted 28 May, 2002;
originally announced May 2002.
-
Radio Luminosities and Classificatory Criteria of BL Lacertae Objects
Authors:
D. C. Mei,
L. Zhang,
Z. J. Jiang,
B. Z. Dai
Abstract:
Using the sample of radio selected BL Lacertae objects (RBLs) and X-ray selected BL Lacertae objects (XBLs) presented by Sambruna et al. (1996), we calculated the luminosities of radio, optical and X-ray of each source and made the statistical analysis among the luminosities at different wave-bands, broad-band spectral indices from radio to X-ray ($α_{\rm rx}$) and peak frequencies ($ν_p$). Our…
▽ More
Using the sample of radio selected BL Lacertae objects (RBLs) and X-ray selected BL Lacertae objects (XBLs) presented by Sambruna et al. (1996), we calculated the luminosities of radio, optical and X-ray of each source and made the statistical analysis among the luminosities at different wave-bands, broad-band spectral indices from radio to X-ray ($α_{\rm rx}$) and peak frequencies ($ν_p$). Our results are as follows: (i) there is a positive correlation between radio luminosity $L_{\rm r}$ and $α_{\rm rx}$ and a negative correlation between $L_{\rm r}$ and $ν_p$. High-energy peak BL Lacs (HBLs) and low-energy peak BL Lacs (LBLs) can be distinguished very well, the dividing lines are probably those of $\log {L_{\rm r}}=43.25$ (erg/sec) and $α_{\rm rx}>$(or $\leq $)0.75 for $L_{\rm r}$ - $α_{\rm rx}$ plot and those of $\log {L_{\rm r}}\leq 43.25$ (erg/sec) and $\log {ν_p}>14.7$ for the $L_{\rm r}$ - $ν_p$ plot; (ii) there is a weak positive correlation between optical luminosity $L_o$ and $α_{\rm rx}$ and a negatively weak correlation between $L_{\rm o}$ and $ν_p$; (iii) there is no correlation between X-ray luminosity $L_X$ and $α_{\rm rx}$ or between $L_X$ and $ν_p$. From our analysis, we find that synchrotron radiation is the main X-ray radiation mechanism for HBLs while inverse Compton scattering for LBLs.
△ Less
Submitted 25 May, 2002;
originally announced May 2002.
-
The hardness-duration correlation in the two classes of gamma-ray bursts
Authors:
Yi-Ping Qin,
Guang-Zhong Xie,
Sui-Jian Xue,
Xue-Tang Zheng,
Dong-Cheng Mei
Abstract:
The well-known hardness-duration correlation of gamma-ray bursts (GRBs) is investigated with the data of the 4B catalog. We find that, while the hardness ratio and the duration are obviously correlated for the entire set of the 4B catalog, they are not at all correlated for the two subsets divided at the duration of 2 seconds. However, for other subsets with comparable sizes, the two quantities…
▽ More
The well-known hardness-duration correlation of gamma-ray bursts (GRBs) is investigated with the data of the 4B catalog. We find that, while the hardness ratio and the duration are obviously correlated for the entire set of the 4B catalog, they are not at all correlated for the two subsets divided at the duration of 2 seconds. However, for other subsets with comparable sizes, the two quantities are significantly correlated. The following conclusions are then reached: (1) the existence of two classes of GRBs is confirmed; (2) the hardness ratio and the duration are not at all correlated for any of the two classes; (3) different classes of GRBs have different distributions of the hardness ratio and the duration and it is this difference that causes the correlation between the two quantities for the entire set of the bursts.
△ Less
Submitted 29 May, 2000; v1 submitted 28 April, 2000;
originally announced May 2000.